UPDATE 15 JULY 2025 - This notice has been updated with additional information, please reread in its entirety and note the new attachments. Joint Base San Antonio has a brand name requirement to procure Daikin Smart Source Compact Vertical Water Source Heat Pumps, Model GCV-Vertical .75 ton, from a singular manufacturer for all current and future renovations of dorms in buildings 1469,1475,1479, 3312, and 3314, consisting of 600 dorm rooms per building, on Ft. Sam Houston.
Water source heat pumps were originally designed and installed for each METC Dorm during the construction period from 2009-2012. The METC dorms utilize a closed-loop system and only these Daikin heat pumps can operate within the buildings existing HVAC system and controls. This specific water source heat pump model is required to maintain the buildings unique climate control system. Without it, the comfort and safety of the Airmen, Soldiers, and Sailors housed in these dorms is at risk.
The system is not compatible with other models. While other water source heat pumps are available, they do not meet the precise specifications of this system, and no other alternative can provide the same functionality. This will also reduce the total cost of ownership by eliminating inefficiencies and duplication in cost by reducing the need to train the METC Dorm maintainers on multiple different systems, and eliminates the need to install a different control system entirely.
Standardization will allow maintenance and repair to be done in house as the primary option versus contracting out these services. This specific heat pump was selected by the 502d HVAC shop, and the stock for repairs already exists, eliminating the need to purchase stock parts from multiple manufacturers.
Any interested responsible party that believes they could manufacture a heat pump that is equally or otherwise uniquely capable of meeting the requirements and functions similarlly within the exsiting system should submit a capability statement. The system you propose MUST utilize R32 refridgerant, R454b is not a valid alternative.
You must also submit supporting evidence in sufficient detail to not only demonstrate the ability to fulfill the requirement but also demonstrate that competition would be more advantageous to the Government.
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
July 15, 2025
Sources sought
Due July 22, 2025 at 2:00 PM EDT. SAM.gov, notice e903b647491a4c86871ae1cd0bad7ad0
Points of contact
- Tyler Adamichtyler.adamich.1@us.af.mil
- SrA Aniram Lopezaniram.lopez@us.af.mil
Also open from this buyer
- Portable Solar GeneratorsCombined synopsis and solicitationSmall businessNAICS 335312San Antonio, TXFA301626Q0277Closes todaySep 17
- MACC - Attachment_8_Q_and_A_Consolidated - GOV Response - Repair Lackland Youth Center PlaygroundSolicitationNAICS 237990FA301626R6034Closes todaySep 17
- Request for Quotes - Remove and Replace CRAC Units and ChillersCombined synopsis and solicitationSDVOSBNAICS 238220TexasFA301626Q0235Closes tomorrowSep 18
- 4-Ton HVAC UnitsCombined synopsis and solicitationSmall businessNAICS 238220TexasFA301626Q0270Closes tomorrowSep 18
- METC Christie Projector InstallationCombined synopsis and solicitationSmall businessNAICS 238210TexasFA301626Q7126Closes tomorrowSep 18