Description

As published on SAM.gov.

Qty 1- GXT Stress Test Machine - Must have SCIMAGE/PICOM connection capabilities. - At least a Windows 10 Operating System or newer. - Set-up, delivery, installation, and user interface training for technician. - ELI LINK connectivity for SCIMAGE/PICOM connection integration. - BP monitoring capabilities with SunTech Tango and SpO2 - Full features include:

• Automatic ST segment analysis and trending on all 12 leads. • Superimposition comparison of current and reference complexes on both a 4x QRS, and updated 12-lead median complexes. • Context View during the exam allowing full disclosure review and addition of past ECG events. • Automatic ventricular ectopic beat detection. • Up to 100 different exercise protocols. • Automatic 12-lead ECGs with prompts for manual or automated (optional) blood pressure acquisition. • Multiple final report formats with custom report sequence capabilities and automated narrative summary. • Networked export of XML, PDF, HL7, or DICOM® results. • Networked receipt of XML, HL7, or DICOM orders. • Archive directories with full disclosure exam data. • User-defined ST measurement points. • Analog and TTL output for interface with external devices. • Programmable and fixed protocols, procedures, and final reports. • Pre-test electrode impedance check. • Demonstration mode. • Automated NIBP and SpO2 readings (with optional device). • Various text and graphical formats. • Medications, notes, diagnoses, indications, and procedural comment entries. • Rate of Perceived Exertion (RPE) entry during test. • Source Consistency Filter (SCF). • Beat Consistency Filter (BCF) on ECG printouts. • METs, maximum predicted heart rate, and target heart rate formula selection. • Various exercise controls with compatible treadmills, ergometers, and pharmacological studies. • Ability to select final report segments including Patient Information, Exam Summary, Rate/BP/Workload Trends, ST Level Trends, ST Slope Trends, Worst Case Average, Periodic Averages, Peak Averages, and ECG Prints. • ST level and slope data for lead and worst-case average beat, updated continually during test.

INTRODUCTION27 • Editing of final report in Review phase. • Paperless workflow capability. • Ability to store exams and final reports in a centralized database. • Pre-registration and scheduling of patients. • Health risk assessment based on Duke and Functional Aerobic Impairment (FAI) algorithms.

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. September 10, 2025

    Sources sought

    Due September 12, 2025 at 4:00 PM EDT. SAM.gov, notice 32ad94f9aa8c4548ba47bc78873fc0e1

Points of contact