Skip to content
Abierto

Sources sought

Dental Washer/Sterilizer

FA483024Q0075

Department of the Air Force, FA4830 23 Cons CC. Dental Equipment and Supplies Manufacturing.

Response deadline

September 21, 2024 at 10:00 AM EDT

Closed 727 days ago. Posted September 19, 2024. Scheduled to archive October 19, 2024.

Description

As published on SAM.gov.

23 Medical Group Laboratory is seeking sources for the purchase of 1 Washer Disinfectors electric washer.

If able to provide this item please contact Ryan Trevino at Ryan.Trevino.2@us.af.mil Required unit is touch screen microprocessor control system, audible warning system, space saving power vertical sliding doors, 8 minimum factory loaded cycles(can be customized) to meet specific operating requirements, chamber illumination by LED lights, USB cycle tape download, drain discharge coll down, chemical dosing system and 180 degree reverse install with printer and comes with a condenser.

Exterior dimensions are 42X80X31" (1067 x 2032 x 787mm) exact dimensions required so no building modification is needed, Interior Chamber Dimensions are 26-1/2 x 26-1/4 x 26" (673 x 667 x 660mm), Load Height 31" (787mm) above finished floor, exact dimensions required so no modification is needed. An Electrical 480V, 60HZ.

Must be able to provide and install: Installation kit, wall trim (if required), Protocol printer, transfer cart, de-install and disposal of old unit, Install new unit, 1 year preventive care, 2 year total care connect, 4 level manifold racks, customer request lift gate. The chemicals utilized for the dental washer need to include only the following:

Prolystica Enzymatic Cleaner, Prolystica neutral detergent & Prolystica non-silicone lubricant. Each of these chemicals are specific to what is needed to wash and clean our instruments that are being used in any type of patient care environment. Additionally, washers need to have the capability to have access from 2 different sides as a pass through washer. The process of this includes the dirty side where instruments are initially placed and then washed prior to taking them out on the clean side.

The dental washer must have a safety measure to where if one side is open, the other side will not open which is a requirement as this reduces the likelihood of cross-contamination between the dirty side and the clean side of this department. Additionally manufacturer needs to fund biomedical training/repair training/service class for proper maintenance on equipment.

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. September 19, 2024

    Sources sought

    Due September 21, 2024 at 10:00 AM EDT. SAM.gov, notice 9b54b60e4c96493697b3d07ace58a991

Points of contact

  • 820 COS Drones
    Sources soughtSmall businessNAICS 336411Moody AFB, GASSFA483026Q0075
    Closes todaySep 18
  • Vinyl Printer and Cutter
    SolicitationSmall businessNAICS 334118Moody AFB, GAFA483026Q0074
    Closes todaySep 18