Combined synopsis and solicitation
Acquisition of Two Triple Multitron Standard Incubation Shakers with Top Cooling
75N98026Q00394
National Institutes of Health, National Institutes of Health Olao. Analytical Laboratory Instrument Manufacturing.
Response deadline
June 1, 2026 at 9:00 AM EDT
Closed 109 days ago. Posted May 19, 2026. Scheduled to archive June 1, 2026.
Description
As published on SAM.gov.
NIDDK owns two Triple Multitron Standard Incubation Shakers with Top Cooling. Each Triple Multitron consists of three stacked incubation shakers within a small footprint. Each of the three incubation shakers within a Triple Multitron is capable of independent temperature and speed control. These features maximize the total amount of cultures that can be grown at the same time, as well as, maximizing the possible growth conditions.
Currently, none of the incubation shakers within the two Multitrons cool properly; and they do not reliably maintain a constant temperature. This procurement is to buy two new Triple Multitron Standard Incubation Shakers with Top Cooling.
The following product features/characteristics are required for this requirement: Each triple incubation shaker unit must consist of three stacked incubation shakers in a small footprint to fit within the available space in the laboratory (not wider than 43 inches and not deeper than 35 inches) Each incubation shaker per triple stacked unit must be capable of independently reaching a temperature that is 15 degrees C below ambient temperature to 65 degrees C to accommodate a large range of temperatures to grow cultures.
Each incubation shaker per triple stacked unit must have a capacity of 6 x 5L Erlenmeyer flasks (total of 18 flasks per triple-stacked unit) to maximize the volume of cultures grown within the small footprint. The temperature and speed of each incubation shaker per triple stacked unit must be able to be set independently of the others to maximize the variety of growth conditions within the small footprint.
Each incubation shaker must have a single bearing eccentric drive to move the main shaft for quiet operation and very little vibration. Each incubation shaker must have the entire shaking mechanism enclosed to ensure temperature uniformity. Each incubation shaker must have four blowers to eliminate dead spots within the cabinet to maintain temperature uniformity. The height of the triple stacked unit must allow it to fit through standard laboratory doors.
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
May 19, 2026
Combined synopsis and solicitation
Due June 1, 2026 at 9:00 AM EDT. SAM.gov, notice 9a0f474e08b44638ade3a36d8ed2138f
Points of contact
- John Burtonburtonjo@mail.nih.gov
Also open from this buyer
- Octet® R4 to Octet® R8 UpgradePresolicitationNAICS 334516Bethesda, MD75N98026Q01175Closes todaySep 18
- Transscleral Flood Illumination (TFI) add-on module for the rtx1 Adaptive Optics Retinal CameraCombined synopsis and solicitationNAICS 423490Bethesda, MD75N98026Q01182IMAGINEOPTICCloses todaySep 18
- Leica M320 Diagnostic ENT Microscope with 4K CameraCombined synopsis and solicitationSmall businessNAICS 334516Bethesda, MD75N98026Q01179LEICAM320Closes todaySep 18
- EVOS™ M5000 Imaging SystemPresolicitationNAICS 334516Bethesda, MD75N98026Q01178Closes todaySep 18
- Deep Ultraviolet (DUV) 320 nm Laser for High-Dimensional Flow Cytometry.PresolicitationNAICS 334516Bethesda, MD75N98026Q01174Closes todaySep 18