Combined synopsis and solicitation
Litron Multiflow and Microflow Kits
75F40125Q130500
Food and Drug Administration, FDA Office of Acq Grant SVCS. Biological Product (except Diagnostic) Manufacturing.
Response deadline
July 16, 2025 at 2:00 AM EDT
Closed 429 days ago. Posted July 10, 2025. Scheduled to archive July 31, 2025.
Description
As published on SAM.gov.
Single Source Acquisition Notification 75F40125Q130500 The Food and Drug Administration (FDA)/National Center for Toxicological Research (NCTR intends to award a Purchase Order on a Single Source basis to Litron Laboratories LTD, 3500 Winton Pl, Rochester, NY 14623, under the authority of FAR 13.106-1(b)(1), Only one Responsible Source and No Other Supplies or Services Will Satisfy Agency Requirements.
The FDA/NCTR requires four (4) MicroFlow In-vitro-1,000/200 kits and six (6) MultiFlow DNA Damage – p53, yH2AX, and Phospho-Histone H3 kits, which will be used for assessing potential genotoxicity of FDA-regulated products (ICH guideline approved).
The associated North American Industry Classification System (NAICS) Code 325414 - Biological Product (except Diagnostic) Manufacturing; with a Small Business Size Standard of 1,250 employees This notice is being published in accordance with Federal Acquisition Regulation (FAR) Part 5.101(a)(1) requiring the dissemination of information on proposed contract actions. This is a notice of intent to award a sole source contract and is not a request for competitive proposals.
The statutory authority for this sole-source procurement is FAR 13.106-1(b)(1). Any firm that believes they can provide the required item(s) as stated herein may submit their capability statement referencing Solicitation 75F40125Q130500 to document their ability on or before July 16, 2025 by 1:00 PM Central Time - Local Prevailing Time in Jefferson, Arkansas by e-Mail to howard.nesmith@fda.hhs.gov. A determination to compete this procurement based on a response to this notice is solely within the discretion of the government.
Minimum Technical Requirements: • In-vitro Micronucleus Kit shall be capable of being used to analyze in vitro samples via flow cytometer using a Becton Dickinson FACSCanto II with a High Throughput auto Sampler (HTS). o Each kit shall contain sufficient quality assured reagents and supplies to analyze 1,000 samples in 96-well plate format or 200 samples in larger microtube format. o Each kit shall allow automated scoring by flow cytometry. o Each kit shall be compatible with 96 well plates, as well as autosamplers and robotics. o Each kit shall be compatible with many different cell lines (more than one type). o Each kit shall be compatible with cells which grow in attachment or suspension. o Supplier shall provide unlimited technical support. o Each kit shall be compatible for use with a variety of attachment and suspension cell lines including L5178Y, CHO-K1, TK6, V79, WIL-2, and HepG2, among others. o Each kit shall be capable of detecting multiple Modes-of-Action. • Each MultiFlow DNA Damage Kit shall contain all of the quality assured supplies and reagents to study multiple endpoints associated with DNA damage response pathways. o Endpoints shall include p53 as an indicator of nuclear p53, ?H2AX as a measure of DNA double strand breaks, and phospho-histone H3 to label mitotic cells. • Kits shall arrive in multiple boxes due to the various temperature requirements (some on dry ice, some on wet ice, and some at room temperature). • Kits shall be delivered in a single delivery to NCTR within 90 days of contract award using the required shipping method to ensure safe and proper arrival of item.
Single Source Determination Based Upon: • The required kits have been used for more than 10years to assess the genotoxicity of various chemicals or chemical mixtures in several protocols. • Litron Laboratories is the owner and manufacturer of the assay kits and is the only known seller of the kits. • No additional sources have been identified as being capable of providing the required kits. • Data generated from associated projects have been used to support other FDA Centers for regulatory decision-making and published in peer-reviewed journals. • Competing this requirement would result in significant detrimental delays in fulfilling Agency’s requirement. • Acquisition of these kits are essential for the continuity of the data collection; past, present, and future. • A change in provider would compromise the integrity of future study and impact the entire research program. • In an effort to maintain continuity and consistency, FDA/NCTR intends to purchase the required kits from Litron Laboratories.
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
July 10, 2025
Combined synopsis and solicitation
Due July 16, 2025 at 2:00 AM EDT. SAM.gov, notice 11e8d07185a74031891aee59ad5d42d5
Points of contact
- Howard Nesmithhoward.nesmith@fda.hhs.gov8705437459
Also open from this buyer
- Animal BloodCombined synopsis and solicitationSmall businessNAICS 325414Silver Spring, MDCDRH2026134634Closes todaySep 18
- Rapid Nicotine Pouch Data Analysis ServicesCombined synopsis and solicitationNAICS 541618Silver Spring, MD75F40126Q00407Closes todaySep 18
- Vanquish Neo System and Ion Chromatography systemSolicitationNAICS 33451675F40126Q000430Closes in 3 daysSep 21
- Fourier Transform Infrared Spectrophotometer (FTIR)Combined synopsis and solicitationNAICS 334516San Juan, PR75F40126Q00406Closes in 4 daysSep 22
- 2D High-Density Multi-Electrode Array Electrophysiology PlatformCombined synopsis and solicitationNAICS 334516RFQ_CBER-2026-135968Closes in 5 daysSep 23