Sources sought
DUCTLESS-SPLIT HEATING AND AIR CONDITIONING SYSTEMS
70Z0G1_SS2024_Ductless_HVAC
US Coast Guard, Ceu Providence. Plumbing, Heating, and Air-Conditioning Contractors.
Response deadline
August 6, 2024 at 4:00 PM EDT
Closed 773 days ago. Posted July 22, 2024. Scheduled to archive August 21, 2024.
Description
As published on SAM.gov.
SOURCES SOUGHT: THIS IS ONLY A MARKET SURVEY FOR WRITTEN INFORMATION ONLY. THIS IS NOT A SOLICITATION FOR PROPOSALS AND NO CONTRACT WILL BE AWARDED FROM THIS ANNOUCEMENT. No reimbursement will be made for any costs associated with providing information in response to this announcement or any follow-up information requests.
In order to protect the procurement integrity of any future procurement that may arise from this announcement, information regarding the technical point of contact will not be given and no appointments for presentations will be made. The U.S. Coast Guard is conducting market research to determine domestic availability of Ductless-Split Heating and Air Conditioning (A/C) Systems.
Specifically, Ductless-Split Heating and A/C Systems that are manufactured in the United States in sufficient and reasonably available commercial quantities of satisfactory quality. The applicable North American Industry Classification System (NAICS) code is 238220 Plumbing, Heating, and Air-Conditioning Contractors. Ductless-Split Heating and A/C Systems are subdivided into three categories: Mini-Split, Multi-Split, and VRF/VRV.
Mini-Split A/C and Heat-Pumps The lowest cost and most common system has one outside unit and one indoor unit. This type of system is generally used for single-zone cooling and/or heating and is common in residential and small commercial settings. Multi-Split A/C and Heat-Pumps This system adds complexity by allowing a single outside condensing unit to supply refrigerant to multiple indoor units for independent temperature controlled zones.
The refrigerant flow is constant and the entire system must be in the same mode (heating/cooling). This means that certain zones cannot be cooling while others are heating. This type of system is generally used to condition a suite of offices or a small group of rooms. VRF/VRV This system works like the multi-split units, but provides the added benefit of being able to heat some zones while cooling others.
The refrigerant compressor is capable of adjusting the flow based on the heating and cooling demands, which makes the system more efficient. Additional devices and controls inherent to VRF/VRV systems also contribute to higher efficiency, but also increases cost and complexity.
In order for the Ductless-Split Heating and A/C Systems to be considered manufactured in the United States, all manufacturing processes must take place in the United States and the cost of components mined, produced, or manufactured in the United States must exceed 55 percent of the cost of all the components. Components of foreign origin of the same class or kind for which nonavailability determinations have been made are treated as domestic.
If your firm is interested or can provide information, please respond by email to Sean.E.Waldron@uscg.mil with subject “Sources Sought Notice Ductless-Split Heating and Air Conditioning Systems 2024”. Your response MUST include the following:
(1) evidence of prior work in providing domestically manufactured Ductless-Split Heating and A/C Systems to include contract numbers, project titles, dollar amounts, points of contact and telephone numbers and (2) detailed information on the domestically manufactured Ductless-Split Heating and A/C Systems. Your response is required no later than August 6, 2024.
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
July 22, 2024
Sources sought
Due August 6, 2024 at 4:00 PM EDT. SAM.gov, notice a7fc418b042b4cefa627d826729f7cb6
Points of contact
- Sean Waldronsean.e.waldron@uscg.mil4017361721
Also open from this buyer
- Repair Aids to Navigation (ATON) - Southern Area of USCG District NortheastPresolicitationSmall businessNAICS 237990New Haven, CT70Z0G126BSSNE1057Closes in 25 daysOct 13
- USCG Cutter Eagle New Dredging for Berthing at New London City PierSolicitationSmall businessNAICS 23799New London, CT70Z0G126BSLISSW02Closes in 27 daysOct 15