Combined synopsis and solicitation, first published as special notice
68HERW26Q0077 - Brand Name Cryo Mill
68HERW26Q0077
Environmental Protection Agency, Water, Tribal & Science Division. Analytical Laboratory Instrument Manufacturing.
Response deadline
September 11, 2026 at 4:30 PM EDT
Closed 5 days ago. Posted September 8, 2026, first published August 4, 2026. Scheduled to archive September 26, 2026.
Description
As published on SAM.gov.
This brand name acquisition is for a Verder Scientific Inc. “Cryo Mill” cryogenic grinder with accessories. This request for quote is limited to authorized distributors of this product, which also includes the manufacturer.
The EPA requires specialized instrumentation to study both microplastics (small plastic particles measuring less than 5 millimeters (mm) in size) and nanoplastics (small plastic particles that measure less than 1000 nanometers (nm) in size). Commercial grinding/milling devices are able to grind material into fine particles. However, the friction from that process generates substantial heat, especially as the material is ground into smaller material. The ability to maintain a consistent cold temperature during this process is needed to prevent the material from melting, which is particularly important for plastic, which can melt from the generated heat to grind small microplastics and nanoplastics under ambient conditions. The Cryo Mill is the only cryogenic grinder that the EPA has determined can meet the government’s specifications. These specifications include:
1. Closed-vial system to reduce polymer contamination during use.
2. Stainless steel grinding chamber/ vial and accessories to reduce sample contamination.
3. Liquid nitrogen autofill accessories to provide continuous cooling of system during grinding and liquid nitrogen sensors for safety precautions.
4. Capacity to grind at least 50 mL of material.
5. Ability to use various sizes of grinding slugs or balls to optimize grinding procedures to make reproducible protocols.
6. Benchtop model to fit in current lab space configuration (under 2 ft2 size).
7. Availability of multiple grinding chambers to avoid cross contamination between different polymers, reduce downtime, and increase sample processing.
8. Demonstrated ability to create nanoplastic particles (<1000 nm).
9. Programmable ability to store multiple protocols for accurate replication of procedures.
The instrumentation for this requirement must include the items listed in Attachment 1 - the Statement of Work.
The EPA’s confidence in the Cryo Mill is based on consistent results achieved in micro and nanoplastic research, as demonstrated in published studies and at institutions like the National Institute of Standards and Technology (NIST), which provided documented information on the Cryo Mill’s unique milling procedures and nitrogen cooling process for grinding plastics to the necessary size. These outcomes have only been realized with the Cryo Mill due to its distinctive configuration, including nitrogen autofill and customizable milling protocols, which are not available in competing products. No evidence was found that other cryogenic grinders can consistently achieve the necessary fineness or deliver results beyond the unique technical specifications of the Cryo Mill—specifically, grinding plastics to sizes below 1000 nm.
Attachments
Files listed on SAM.gov. The ones we hold a copy of download from here; the rest open SAM's download, which needs no account.
- b7bc4260df7f4edd8487d5ed7e7882ef0 B, September 8, 2026
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
August 4, 2026
Special notice
Notice of Intent to Sole Source
Due August 20, 2026 at 4:30 PM EDT. SAM.gov, notice 08b51593f5ad43ce97bdef721f0c7bb3
September 8, 2026
Combined synopsis and solicitation, originally special notice
Due September 11, 2026 at 4:30 PM EDT. SAM.gov, notice 5083c20f2d4a44468e0dc5b378237cfd
2 revisions on SAM
- September 8, 2026: publish, combined synopsis and solicitation
- August 4, 2026: publish, special notice
Points of contact
- Fischer, Charles K.fischer.charles@epa.gov513-569-7064
Also open from this buyer
- Comprehensive two dimensional-gas chromatography tCombined synopsis and solicitationSmall businessNAICS 33451668HERW26Q0067Closes in 2 daysSep 18
- One Supercritical Fluid Extraction SystemSolicitationNAICS 33451668HERW26Q0093Closes in 5 daysSep 21