Presolicitation, total small business set-aside
Portland VAMC IRM 3860+ INFUSION PUMP MRIDIUM MR W/SP02
36C260-24-AP-0461
Department of Veterans Affairs, 260-Network Contract Office 20. Surgical and Medical Instrument Manufacturing.
Response deadline
March 6, 2024 at 3:00 PM EST
Closed 925 days ago. Posted February 27, 2024, first published February 27, 2024. Scheduled to archive March 21, 2024.
Description
As published on SAM.gov.
Portland VAMC requies two IRM 3860+ INFUSION PUMP MRIDIUM MR W/SP02 and accessories. See attached solicitation for details and quanties. The Department of Veterans Affairs (VA), Network Contracting Office (NCO) 20, is soliciting to identify potential sources which can provide the following item: SALIENT CHARACTERISTICS. Must operate on 115-120V AC (US) and battery. Entire pump and components must be non-magnetic and able to be used in a 3T MRI.
Must have: Smart IV Pump Technology & Real Time SpO2 Monitoring 10 digit Keypad Entry Conventional IV pump design Nonmagnetic design allowing it to be placed up to the 10,000 Gauss Line Delivery Range of 0.1 to 1400 mL per hour with 0.1 ml./hr increments from 0.1 to 99.9 mL/hr and 1 ml increments from 100 to 1400 mL/hr.
Easily expandable to a second channel with add-on SideCar™ module Have a long life Lithium Polymer battery Must use a vented 1057 Syringe Set with low priming volume for anesthetic and other syringe-based Drug Delivery Battery Capacity > 12 Hours at ?125 mL/hr Rate Range of Volume to be infused from 0.1 to 999 ml. Range of Total Volume infused 0.1 – 9,999 ml in 0.1ml increments. Keep Vein Open Range adjustable from 1-5 ml/hr.
Air in line detector must be >100 microliters Must be compliant with IEC 60601-1-1, IEC 60601-1-2, IEC 60601-2-24, ISO 9919, AAMI ID 26, UL2601. Must have a small form factor, and fit into the existing space available in the MRI gantry rooms without crowding or causing risk of patient or staff injury.
Locations: PORTLAND VA MEDICAL CENTER 3710 SW US VETERANS HOSPITAL RD PORTLAND, OR 97239 A DRAFT statement of requirement is attached. The Government is accepting industry comment on the specifications. Comments may or may not be incorporated, at the discretion of the Government. Potential candidates having the capabilities necessary to provide the above stated equipment are invited to respond to this RFQ via e-mail to Alan Perez at Alan.Perez@va.gov no later than Tuesday, 05 March 2024 at 3PM EST. No telephone inquiries will be accepted.
RESPONSES SHOULD INCLUDE THE FOLLOWING INFORMATION: Company name Address Business size Unique Entity ID Number Point of contact name Phone number E-mail address Capability statement to include ability to provide the supplies in the list. If the services are available on a current GSA Federal Supply Schedule contract. NAICS Code 339112 with a size standard of 1000 Employees is applicable to this requirement. Any questions or concerns may also be directed to Alan Perez via e-mail.
Disclaimer and Important Notes: This solicitation does not obligate the Government to award a contract or otherwise pay for the information provided in response. The Government reserves the right to use information provided by respondents for any purpose deemed necessary and legally appropriate. The Government will treat any information received as proprietary and will not share such information with other companies.
Any organization responding to this solicitation should ensure that its response is complete and sufficiently detailed to allow the Government to determine the organization's qualifications to perform the work. Respondents are advised that the Government is under no obligation to acknowledge receipt of the information received or provide feedback to respondents with respect to any information submitted. The Government may or may not issue an award as a result of this announcement.
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
Points of contact
- Alan PerezAlan.Perez@va.gov
Also open from this buyer
- VISN 5 Optical Fabrication Laboratory Lens Production MachinesCombined synopsis and solicitationNAICS 339115Boise City, ID36C26026Q1006Closes todaySep 17
- DOT Commercial Drivers Physicals & Controlled Substance Test Puget Sound VAHCSSources soughtNAICS 621999Washington36C26027Q0035Closes todaySep 17
- Betterbuilt R640 Series Cart and Utensil Washer, Name Brand or EquaCombined synopsis and solicitationNAICS 333310Portland, OR36C26026Q0346Closes todaySep 17
- Environmental Liabilities SurveySources soughtNAICS 541620Spokane, WA36C26026Q1020Closes todaySep 17
- SANE Services Portland VA Medical CenterCombined synopsis and solicitationNAICS 813920Portland, OR36C26026A1014Closes tomorrowSep 18