Sources sought
36C259-26-AP-3574 | Research Labs 30 cu ft Freezers One time buy
36C25926Q0679
Department of Veterans Affairs, Network Contract Office 19. Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing.
Response deadline
July 29, 2026 at 10:00 AM EDT
Closed 49 days ago. Posted July 23, 2026. Scheduled to archive August 28, 2026.
Description
As published on SAM.gov.
REQUEST FOR INFORMATION / SOURCES SOUGHT SYNOPSIS The Department of Veterans Affairs Network Contracting Office (NCO) 19, Rocky Mountain Acquisition Center (RMAC) is issuing this source sought notice as a means of conducting market research to identify parties having an interest in the providing for the purchase of Freezers for Research Service, located at Rocky Mountain Regional VA Medical Center (RMRVAMC), 1700 N. Wheeling St, Aurora, CO 80045. The result of this market research will contribute to determining the method of procurement to support this purchase.
The purpose of this RFI is to gather information that will assist in determining the appropriate acquisition strategy for this requirement. This notice does not constitute a solicitation and does not commit the Government to contract for any supply or service.
Required Equipment Description: 30 cubic foot upright manual defrost laboratory freezers with 20°C capability. Salient Characteristics (Mandatory Minimum Requirements) General Design Purpose Freezers must be upright, general laboratory units with manual defrost capability. Units must provide audible and visual alarms. Temperature display and alarms must be located on the front or top front of the unit, no alarms or displays at the back or bottom. Adjustable operating temperature range: 15°C to 25°C.
Capacity & Dimensions Minimum internal storage capacity: 30 cubic feet. Must include four evaporator shelves. Maximum external dimensions: 40 in (W) × 36 in (D) × 78 in (H). Door swing must not exceed 32 inches. Temperature Control Digital temperature display required. Temperature controls and alarm acknowledgements must be located on front or top front panel. Units must be manual defrost only; automatic defrost systems are not acceptable. Alarms & Monitoring High/low programmable alarms required.
Door ajar alarm must be audible and visual. Alarm placement must be front or top front only. Doors & Access One solid right hinge door. Stainless steel handle and magnetic door gasket. Electrical Requirements Must operate on 110 120 V AC power supply. Minimum 6 foot power cord. Maximum full load current: 15 amps. Maximum fuse or circuit breaker rating: 15 amps.
Warrant Provide warranty: The applicable North American Industry Classification System (NAICS) code assigned to this procurement is 333415 (Air Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing). THIS IS A REQUEST FOR INFORMATION AND SOURCES ONLY, WHICH MAY OR MAY NOT LEAD TO A FUTURE SOLICITATION! THIS IS NOT A SOLICITATION.
This request for capability information does not constitute a request for proposals; submission of any information in response to this market survey is purely voluntary; the government assumes no financial responsibility for any costs incurred. IN RESPONSE TO THIS ANNOUNCEMENT, PLEASE PROVIDE THE INFORMATION BELOW. IF THIS INFORMATION IS NOT PROVIDED, THEN IT WILL BE ASSUMED THE ENTIRE REQUIREMENT CANNOT BE MET AND YOUR RESPONSE WILL NOT BE INCLUDED AS A POTENTIAL SOURCE.
NAICS Code:
333415 Company Name:
Address: UEI (Unique Entity ID)
Number:
Contact Name:
Phone No.:
Email: Business Size Information - Select all that applies: Small Business Emerging Small Business Small Disadvantaged Business Certified under Section 8(a) of the Small Business Act HUBZone Woman Owned Certified Service-Disabled Veteran Owned Small Veteran Owned Small Business Large Business FSS/GSA Contract Holder:
Yes No FSS/GSA Contract Number:
Effective Date/ Expiration Date: Proposed solution is listed and available on the above FSS/GSA Contract: Yes No Available pricing structure of proposed solution (select all that are applicable below):
Pricing Model Please Indicate Availability Below:
(Yes / No / NA) Equipment on FSS Open Market only Comments Equipment Purchase Federal Acquisition Regulation (FAR)
Market Rearch Questions: Limitations on Subcontracting (FAR 52.219-14) What percentage of the work would be subcontracted to another company?
If > 0, what is company s business size:
If subcontracting, what added value do you offer (FAR 52.215-23):
Buy American Act (FAR 52.225) What percentage of the proposed product (including leases) is a: Domestic end product?
(%) Foreign end product?
(%)
Nonmanufacturer Rule (FAR 52.219-33): Does your company manufacturer these proposed items? [Â ] yes [Â ] no Does your company exceed 500 employees? [Â ] yes [Â ] no If yes, list # of employees: BASED ON THE RESPONSES TO THIS SOURCES SOUGHT NOTICE, THIS REQUIREMENT MAY BE SET-ASIDE FOR SMALL BUSINESSES OR PROCURED THROUGH FULL AND OPEN COMPETITION OR FEDERAL SUPPLY SCHEDULE (FSS). Telephone inquiries will not be accepted or acknowledged, and no feedback will be provided to companies regarding their submissions.
SUBMISSION INSTRUCTIONS: If your organization has the capability to provide the Equipment, please respond to Alejandra Sierra, Contracting Officer, via e-mail at Alejandra.Sierra@va.gov and NCO19Lab@va.gov with a statement describing your capabilities and the completed table above. The deadline for responses is Wednesday, July 29, 2026 at 08:00 AM Mountain time.
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
July 23, 2026
Sources sought
Due July 29, 2026 at 10:00 AM EDT. SAM.gov, notice 1be803e8584a44408d076070088db960
Points of contact
- Alejandra Sierra, Contracting OfficerAlejandra.Sierra@va.gov303-712-5715
Also open from this buyer
- OR Tables w/ integrated patient warmerCombined synopsis and solicitationSmall businessNAICS 339112Wyoming36C25926Q0782Closes todaySep 16
- EksoNR Exoskeleton – Gait Training DeviceCombined synopsis and solicitationSmall businessNAICS 334510Oklahoma36C25926Q0851Closes tomorrowSep 17
- Bulk Oxygen and Tank Rental for Oklahoma City VA Health Care System Base Plus 4 Option YearsCombined synopsis and solicitationSDVOSBNAICS 325120Oklahoma36C25926Q0814Closes tomorrowSep 17
- 635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)SolicitationSDVOSBNAICS 236220Oklahoma36C25926R0082_1Closes tomorrowSep 17