Sources sought
ENGINEERING SEMPS RADIO SYSTEM MUSVAMC
36C25925Q0763
Department of Veterans Affairs, Network Contract Office 19. Radio and Television Broadcasting and Wireless Communications Equipment Manufacturing.
Response deadline
September 4, 2025 at 12:00 PM EDT
Closed 379 days ago. Posted August 25, 2025. Scheduled to archive October 4, 2025.
Description
As published on SAM.gov.
36C25925Q0763 Sources Sought / Request for Information Motorola Mototrbo R2 OR BRAND NAME EQUIVALENT UHF Radio System. Eastern Oklahoma VA Health Care System Jack C. Montgomery VA Medical Center Muskogee, OK. 74401 BRIEF SCOPE OF WORK (This is for information only) Motorola Mototrbo R2 OR BRAND NAME EQUIVALENT UHF Radio System. in accordance with the terms and conditions stated within this abbreviated Performance Work Statement (PWS). The subsequent solicitation is planned to be a Base with Four possible Option Year(s) Contract. This is a Request for Information (RFI) Only for Market Research purposes, no Award will be made from this RFI.
1. GENERAL: This is a non-personnel services requirement. The contractor shall provide all management, supervision, labor, transportation, tools, materials, parts, and other items necessary to perform work, execute services, and to successfully complete all deliverables as contained within this Scope of Work.
The Government shall not exercise any supervision and/or control over contractor personnel (which includes contractor service providers, contractor representatives, and subcontractors employed with and/or being utilized by the prime contractor) during all active performance periods of the contract. All contractor personnel shall be accountable solely to the Contractor, who in turn is responsible to the Government.
2. BACKGROUND: An emergency radio communication system for the facility is required for personnel to communicate to internal personal. The current system is a VHF system and is very outdated and hard to get parts for or service. A new UHF system is needed to provide the proper signal to communicate site wide. To meet these needs, a UHF system must be procured with all components necessary for the system to send and receive signals site wide.
3. SCOPE OF SERVICES: Services needed under this effort (to include required Deliverables) are described below:
A site survey will be required before award to determine what will be needed to install a system that will include all parts and accessories needed to provide coverage throughout the entire Jack C Montgomery VA Medical Center, approximately 650,000 sq ft. Requirement will include all parts and labor needed to completely install the system. System will need to be tested throughout the facility to ensure proper coverage in all areas that the Engineering Service deems necessary.
Contractor will provide System Documentation to include, but not limited to, troubleshooting guides, technical specs, parts list, manuals, libs, Compact Discs, etc.. Contractor to provide 65 radios with antenna, battery, and charging stations. Contractor to provide and install a repeater with appropriate hardware for said radios to work in the UHF frequency range.
Contractor will provide 60 month maintenance contract to include Testing, Preventative Maintenance, and Corrective Maintenance/Troubleshooting and Repair, Warranty Repairs, on installed system IAW (in accordance with) System Documentation.
The Contractor shall provide non-personnel services including all management, supervision, personnel, transportation, tools, materials and other items and services necessary to install, support, and maintain the Bi-Directional Amplifier System in JCM VAMC in accordance with this Statement of Work (SOW).
Radios shall meet the following requirements: Frequency 400-480 MHz UHF Channel spacing 12.5 / 25.01 kH Channel capacity 64 Battery life 17 Hours (one potential work shift without recharging) Operating temperature* -22 °F to 140 °F Dust and water intrusion IP55 Salt fog Per MIL-STD 810C/D/E/F/G/H Humidity Per MIL-STD 810C, D, E, F, G, H Thermal shock Per MIL-STD 810C, D, E, F, G, H Electrostatic discharge IEC 61000-4-2 Level 4 The radio delivers a clear signal.
Transmit Interrupt The radio uses the same accessories as other units in that particular brand and does not require unique adapters for regular use or adding accessories. Minimum of 5 year local service agreement for technical support, updates and repair service, (local within an hour drive) b. Full operational testing of system upon completion of installation with in-service provided to Facility Personnel. c. 5-year warranty on all components Bases of design/Products:
IMPORTANT NOTE: This RFI (Request for Information) is for information only. No award will be made from this RFI. Please communicate via e-mail to orrellius.williams@va.gov by COB September 4, 2025 as to your company s ability to provide commodities/ provide service per this Brief Scope of Work. If interested, please provide the following:
Please state your company s business size Please provide DUNS number If you have a FSS/GSA contract that includes this service Provide FSS/GSA contract number if applicable If not Motorola are Name Brand Equivalent products made in the USA?
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
August 25, 2025
Sources sought
Due September 4, 2025 at 12:00 PM EDT. SAM.gov, notice 738a8684218f46d8b165dcf5e31c3072
Points of contact
- Orrellius Williams, Contract Specialistorrellius.williams@va.gov918-252-8812
Also open from this buyer
- Patient Ceiling Lift ServiceCombined synopsis and solicitationSmall businessNAICS 811210Sheridan, CO36C25926Q0843Closes todaySep 18
- MiPACS Licenses and Support OKC, Yukon & Norman DentalCombined synopsis and solicitationNAICS 541519Oklahoma City, OK36C25926Q0853Closes todaySep 18
- Fire Alarm-Fire Suppression Services for the VA Salt Lake City, Utah Medical CenterCombined synopsis and solicitationNAICS 561621Salt Lake City, UT36C25925Q0740Closes todaySep 18
- Public Address Mass Notification System (PAMNS) and Code Blue Help Point System Maintenance Support Services for the VA Salt Lake City UTCombined synopsis and solicitationNAICS 811210Salt Lake City, UT36C25926Q0715Closes todaySep 18
- Patient Observation Rounding SystemCombined synopsis and solicitationNAICS 513210Salt Lake City, UT36C25926Q0825Closes todaySep 18