The purpose of this amendment is to respond/answer questions regarding solicitation 36C25925Q0634. The solicitation has Line item 2 as SKF05 and Line item 3 as SKF02 but we believe they should be BSKF05 and BSKF02 respectively. Yes, these should be BSKF02 and BSKF05, baskets. I wanted to confirm the postal code for the place of performance (ship to address) and whether it is 81507 or 81501. 81507 is the ship to address zip code.
May I kindly request if you could provide: Manufacturer names and part numbers (if available); Or any technical data sheets, catalog references, or brand-specific equivalents? The line-item codes provided in the RFQ (e.g., SC08FG, SKF05, MAT042) appear to be internal references, and we are unable to cross-reference them without further specification. These line items are not internal inventory numbers; they are Case brand numbers. We are not requiring any specific brand, this is an OR EQUAL solicitation.
The brands shown in this solicitation are examples. Since the RFQ references both Aesculap and CASE Medical but only references the CASE Medical part # s in the RFQ, would it be feasible to also add-in the corresponding Aesculap part # s (attached). We ve found that specific part # s provide an inherent advantage. Therefore, requesting that the Aesculap part # s also be referenced within the RFQ.
Please refer to the sample product information below. https://www.bing.com/search?q=what+is+the+equivalent+aesculap+to+sc08fg+container+case+size&qs=GS&pq=what+is+the+equivalent+aesculap+to+sc08fg+container+case&sc=12-56&cvid=AF642BFCA4C3499CAD04FF1628ED1EBC&FORM=QBRE&sp=1&lq=0 https://casemed.com/index.php/products/containers Is the QR code required on every container - immediately provides instructions for use as well as data specifications such as size, weight, and product codes and can be accessed from a tracking scanner or any smart phone or tablet.
See the updated list of Salient Characteristics below. Item 5. Please identify how these are provided. Does the Grand Junction VAMC prefer a sterilization container which is also validated as a bio-hazard transport bin for soiled sets/instruments? Per the SPS department this feature is not required.
Salient Characteristics: Must be compatible with sterilization cycles including Prevac, IUSS, Gravity, Steam, and low temp sterilization for STERRAD 100NX machines. Must have ergonomic handles. Must have a filter retention plate with audible click or valve to replace filter. Must have containers that are validated to be stacked during sterilization and storage. Must have accompanied manufacturer s instructions for use. Must be compatible with automated washer disinfectors with ability to withstand temperatures of 190 degrees.
The contract, on USAspending
Federal procurement data the awarding office reported to FPDS, matched to this solicitation by its number.
- Recipient
- Case Medical Inc.
- UEI
- TPMXL7L6AS98
- CAGE
- 1C0D9
- Vendor location
- Bloomfield, NJ
- Contract
- 36C25925P1024, purchase order
- Obligated
- $68,582.08
- Actions
- 1 between August 26, 2025 and August 26, 2025
- Competition
- Competed Under SAP, 5 offers received
- Set-aside reported
- Small Business Set Aside - Total
- Described as
- SPS Sterilization Containers
- Match
- solicitation number 36C25925Q0634 equals the FPDS solicitation identifier; same awarding office 36C259 (high confidence)
- Record
- USAspending award page
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
Points of contact
- Tamanica Danford-Leaf, Contracting Officertamanica.danford-leaf@va.gov303-712-5830
Also open from this buyer
- EksoNR Exoskeleton – Gait Training DeviceCombined synopsis and solicitationSmall businessNAICS 334510Oklahoma City, OK36C25926Q0851Closes todaySep 17
- Bulk Oxygen and Tank Rental for Oklahoma City VA Health Care System Base Plus 4 Option YearsCombined synopsis and solicitationSDVOSBNAICS 325120Oklahoma City, OK36C25926Q0814Closes todaySep 17
- 635-21-139 | Repair Parking Garage 1 Deficiencies | CON (VA-26-00041470) (NRM - SCIP# VHA19-635-2023-52398)SolicitationSDVOSBNAICS 236220Oklahoma City, OK36C25926R0082_1Closes todaySep 17
- CCTV MOBILE CAMERA TRAILERS - SHERIDAN VAMCCombined synopsis and solicitationSmall businessNAICS 561621Greenwood Village, CO36C25926Q0812Closes todaySep 17
- Surgery Lumber Retractor Instruments – Domestic End ProductsCombined synopsis and solicitationSmall businessNAICS 339112Muskogee, OK36C25926Q0861Closes todaySep 17