Sources sought
Fort Harrison VA Medical Center (North) 436 AB Scanner (VA-25-00075498)
36C25925Q0495
Department of Veterans Affairs, Network Contract Office 19. Surgical and Medical Instrument Manufacturing.
Response deadline
June 10, 2025 at 2:00 PM EDT
Closed 464 days ago. Posted June 3, 2025. Scheduled to archive August 9, 2025.
Description
As published on SAM.gov.
Sources Sought Notice A/B SCAN SYSTEM DISCLAIMER This RFI is issued solely for information and planning purposes only and does not constitute a solicitation. All information received in response to this RFI that is marked as proprietary will be handled accordingly. In accordance with FAR 15.201(e), responses to this notice are not offers and cannot be accepted by the Government to form a binding contract. Responders are solely responsible for all expenses associated with responding to this RFI.
Response Instructions: Do not provide more than 8 pages, including cover letter page. Submit your response via email to:
barron.long@va.gov Submit your response NLT 12:00 (MST) on Tuesday June 10th Mark your response as Proprietary Information if the information is considered business sensitive. VA has identified the appropriate North American Industry Classification System (NAICS) Code 339112 Surgical and Medical Instrument Manufacturing with a Small Business size of 1000 employees. Please identify and explain any NAICS codes your company believes would better represent the predominated work included in the attached Statement of Work draft / Salient Characteristics List;
Information Requested from Industry: In response to the Sources Sought, interested Contractors shall submit the following information and any Capabilities/Qualifications Statement to include but not limited to an overview of proposed solution(s) and a description of the product your company possesses accordance with the Statement of Work draft / Salient Characteristics List.
Vendor Name:
SAM UEI #:
Name of Manufacturer:
Manufacturer Address:
Estimated Delivery Time: SAC FSS contract number Vendor Point of Contract (POC)
Name POC Phone Number:
POC Email Address: Statement of Work A/B scan instrument MUST be on the approved list of equipment for Forum compatibility must have an ERA and be Vista Approved Must have DICOM compliance capability. A/B scan probes must be detachable so it can be processed by SPS in accordance with our disinfecting policy. Must have A-scan and B-scan options for measuring eye length and retinal thickness or lesion thickness.
Due to space constraints of room equipment will be utilized in, need a single unit with interchangeable probes no larger than 15 x15 footprint. Due to limited space constraints and sensitive electrical equipment, must be direct contact A-scan NOT immersion for obtaining readings. Needs foot pedal to obtain readings so do not have to resituate while taking readings. Must plug into standard US outlet.
Must be MADE IN THE USA Manufacturer must set up equipment and provide instructional training to provider and technicians. Task 1 - Enterprise Management Controls. Subtask 1 A/B Scan equipment and software must be compatible with Forum which is in place across VA Montana. Instrument will be used to take axial length, anterior chamber depth, white to white, and lesion thickness measurements, then transmit those measurements to the VA internal platform Forum where they can be assessed by the doctor.
There is a specific list of approved devices that have been validated through the VistA database for compatibility with Forum. Any equipment that is not on the list is not guaranteed to work with Forum which is established and utilized throughout VA Montana, and the rigorous testing process to see if a piece of equipment is compatible take almost 12 months. Security Requirements Interfaces with Forum an internal storage platform that is already in use across VA Montana. 7. Place of Performance.
Will be in the Billings VA Ophthalmology Clinic to be used by the ophthalmologist or ophthalmology technician on staff for measurements unable to be obtained by IOL master or OCT or to get an idea of retinal layers when view into eye is obstructed. 8. Delivery Schedule. Contracted vendor will deliver to Billings VA (Benjamin Steele) and coordinate with Biomed for installation in the exam room on a date when the doctor in not seeing patients.
Once the instrument has been set up Biomed with work with Ophthalmology department to schedule a training with the manufacturer to provide education on functionality and performance.
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
June 3, 2025
Sources sought
Due June 10, 2025 at 2:00 PM EDT. SAM.gov, notice de5c3f6946fd4a82893f57c20140e342
Points of contact
- BARRON LONG, CONTRACT OFFICERBARRON.LONG@VA.GOV303-712-5741
Also open from this buyer
- EksoNR Exoskeleton – Gait Training DeviceCombined synopsis and solicitationSmall businessNAICS 334510Oklahoma City, OK36C25926Q0851Closes todaySep 17
- Bulk Oxygen and Tank Rental for Oklahoma City VA Health Care System Base Plus 4 Option YearsCombined synopsis and solicitationSDVOSBNAICS 325120Oklahoma City, OK36C25926Q0814Closes todaySep 17
- Surgery Lumber Retractor Instruments – Domestic End ProductsCombined synopsis and solicitationSmall businessNAICS 339112Muskogee, OK36C25926Q0861Closes todaySep 17
- Patient Ceiling Lift ServiceCombined synopsis and solicitationSmall businessNAICS 811210Sheridan, CO36C25926Q0843Closes tomorrowSep 18
- MiPACS Licenses and Support OKC, Yukon & Norman DentalCombined synopsis and solicitationNAICS 541519Oklahoma City, OK36C25926Q0853Closes tomorrowSep 18