As published on SAM.gov.
STATEMENT OF WORK (SOW)
Rotarex for Radiology GENERAL INFORMATION Title of Project: Procurement of the Rotarex Atherectomy System for KC VAMC.
Scope of Work: The vendor shall provide all resources necessary to accomplish the deliverables described in the statement of work (SOW), except as may otherwise be specified.
Background: The Kansas City VA Medical Center Radiology Department provides services to veterans in which the Rotarex Atherectomy System which is used as an atherectomy device and to break up and remove thrombus from native peripheral arteries or peripheral arteries fitted with stents, stent grafts or native or artificial bypasses.
GENERAL REQUIREMENTS:
New and Unused: Equipment shall be new, unused, produced from current production components, and shall be delivered ready for use.
EQUIPMENT: The Rotarex™ Atherectomy System is made up of a single use Rotarex™ Atherectomy Catheter Set and the Drive System, consisting of the Control Unit, Motor and Footswitch. The Rotarex™ Atherectomy Catheter Set is composed of multiple components, including the Rotarex™ Atherectomy Catheter, supplied guidewire, collecting bag, and sterile drape.
Rotarex™ Atherectomy Catheters are over-the-wire, single use, percutaneous devices for the removal of atheromatic plaque and thrombi from native peripheral arteries or peripheral arteries fitted with stents, stent grafts or native or artificial bypasses. The catheters are latex and phthalate free, and consist of a flexible outer covering, a rotating head, and a rotating helix which runs the length of the catheters.
A lumen for the passage of the supplied guidewire runs the entire length of the helix and through the head of the catheter. The catheter head is made up of two overlying metal cylinders, with two side openings. The outer cylinder is connected to the rotating helix, and the inner cylinder to the catheter shaft.
The helix and the catheter head rotate at approximately 40,000-60,000 rpm depending on the model, by means of a gear box in the catheter housing and a motor contained within the catheter handle driven by the Drive System. The rotating outer cylinder is fitted with abrading facets at its foremost tip. The Rotarex™ Atherectomy System Guidewires are 0.018" and are included with each Rotarex™ Atherectomy Catheter Set. These supplied guidewires consist of a Nitinol core and a PTFE coating with a 9.5 cm hydrophilic distal coating and a 4 cm angled flex tip.
WARRANTY: The manufacturing warranty is for 1 year and that one-year manufacturing warranty starts when the device is first shipped to the customer. If any issues occur during that first year after they’ve purchased the device, they will coordinate getting the device return for service and would not be billed for any shipping, parts, or labor to repair the device.
If the failure occurs after that 1st year, the device would not be under warranty, and they would have to pay for shipping and that came due outside of warranty. Vendor will provide loaners if needed at no cost to the customer while their device is still under a manufacturing warranty. If not under warranty, the loaner cost is $200 a month. The drive system does not require yearly maintenance.
DELIVERY & LOCATION INFORMATION:
Kansas City VA Medical Center Attention: X-Ray M2-417 4801 East Linwood Boulevard Kansas City, MO 64128-2226
The contract, on USAspending
Federal procurement data the awarding office reported to FPDS, matched to this solicitation by its number.
- UEI
- TLTXKMLQEYU9
- CAGE
- 65HC5
- Vendor location
- Jacksonville, FL
- Contract
- 36C25524P0170, purchase order
- Obligated
- $25,000.00
- Actions
- 1 between January 16, 2024 and January 16, 2024
- Competition
- Competed Under SAP, 1 offer received
- Set-aside reported
- Service Disabled Veteran Owned Small Business SET-ASIDE
- Described as
- Rotarex Atherectomy System
- Match
- solicitation number 36C25524Q0115 equals the FPDS solicitation identifier; same awarding office 36C255 (high confidence)
- Record
- USAspending award page
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
January 5, 2024
Solicitation
Due January 11, 2024 at 3:00 PM EST. SAM.gov, notice cc56cb3af8b3410e838fcca80a0769e8
Points of contact
- Jon LutmerJonathan.lutmer@va.gov410-446-3862
Also open from this buyer
- 589A7-21-132 Construct Centralized Emergency Power SystemSolicitationSDVOSBNAICS 236220Wichita, KS36C25526R01250002Closes todaySep 18
- 36C25526Q0650 657-27-101, FCA-Conduct Hazardous Material Abatement, 2027 AE Design -FY27 NRMSources sought36C25526Q0650Closes todaySep 18
- Uninterruptible Power Supply St. Louis VA Medical CenterSources soughtNAICS 81121036C25526Q0678Closes todaySep 18
- Induction Charger for food warmerSources soughtSDVOSBNAICS 335999Kansas City, MO36C25526Q0657Closes todaySep 18
- BACKFLOW ANNUAL INSPECTION, TESTING & MAINTENANCE MARION, IL VA MEDICAL CENTERSources soughtSDVOSBNAICS 238220Illinois36C25527Q0005Closes todaySep 18