Description

As published on SAM.gov.

ELLEX ABSOLU S ULTRASOUND CONSOLE WITH A-STD PROBE (P/N PCBX0037S1S) QTY:1 ELLEX BIOMETRY A-SCAN PROBE FOR ABSOLU Ground plate w/o filter QTY:2 ELLEX 15 MHz B PROBE FOR ABSOLU/ABSOLU S QTY:2 50 MHz LINEAR HIGH-RESOLUTION PROBE FOR ABSOLU/ABSOLU S SYSTEMS ONLY QTY:1 STANDARDIZED A PROBE (PROBE ONLY) FOR ABSOLU S MODULES ONLY QTY:5 ELLEX BOX OF CLEARSCANS QTY:1 ELLEX DICOM SOFTWARE FOR ABSOLU ULTRASOUND QTY:1 ELLEX WIRELESS 9 FUNCTION FOOTSWITCH FOR ABSOLU/ABSOLU S QTY:1 ELLEX ULTRASOUND CART FOR ABSOLU & COMPACT TOUCH 2 QTY:1 ELLEX ULTRASOUND CLINICAL APPLICATIONS TRAINING QTY:1 Salient Characteristics Brand Name or Equal:

A-scan Biometry: to verify measurements of the length of the eye (axial length) -Immersion A-scan -Direct contact A-scan -QTY Two (2) Biometry A-scan transducers -Auto Axial length average and standard deviation calculations -IOL Formulas -Lens Database -measurement tools B-scan 15 MHz B-scan probe -Qty Two (2) Biometry B-scan transducers UBM -QTY One (1) UBM Transducer -QTY Ten (10) single-use sterile UBM-probe cover devices -QTY Six (6) 8-MHz A-scan diagnostic transducers allows for: diagnosis of tumor lesions, diagnosis of retinal vitreous membrane detachment and diagnosis of Graves disease -probe positioning feedback/visualization -Static and dynamic image capture and storage -Image Annotation -pachymetry probe self-check/auto calibration -DICOM networking, compatibility to send to Ziess Forum -Footswitch -height-adjustable cart with keyboard tray -1-day on-site Clinical Applications training to identify sight threatening retinal lesions, such as ocular tumors measurements critical in determining what power lens implant to place in the eye after cataract surgery -Sulcus-to-Sulcus measurements -corneal thickness measurements -IOP correction formulas VA Networked Medical Device risk assessment documents: VA Directive 6550 Ports, Protocols, and Security spreadsheet Inventory List MDS2 Network Topology Diagram Software Bill of Materials A Letter of support is required if there is any vendor proprietary firmware, customized OS, or COTS Devices (i.e. NAS, Firewall, switch, HW load balancer, etc.)

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. July 7, 2026

    Solicitation

    Due July 21, 2026 at 11:00 AM EDT. SAM.gov, notice 406eb5b940af4a8fac36cebf03901f4f

Points of contact