Sources sought, total small business set-aside
Patient Transfer Chairs FSS Pre-Solicitation Sources Saught Brand Name or Equal
36C24826Q0930
Department of Veterans Affairs, 248-Network Contract Office 8. Electromedical and Electrotherapeutic Apparatus Manufacturing.
Response deadline
July 16, 2026 at 2:00 PM EDT
Closed 62 days ago. Posted July 15, 2026, first published July 8, 2026. Scheduled to archive July 31, 2026.
Description
As published on SAM.gov.
Good day, SDVOSB s, VOSB s & SB's FSS Pre-Solicitation Sources Sought This Sources Sought is issued solely for informational and planning purposes only. It does not constitute the issuance of a solicitation or a promise to issue solicitation in the future. The purpose of this notice is to conduct market research and obtain information from qualified SB and large businesses. This is not a request for bids, quotes, offers, or proposals.
The responses to this announcement will assist in determining the socio-economic status such as a SDVOSB set-aside if feasible. If insufficient SDVOSB responses are received to establish the basis for setting this requirement aside for SDVOSB s, the requirement may be solicited as a VOSB or a SB set aside, if no or not enough small business responses are received, this may be solicited as unrestricted, all interested parties responding shall be eligible to compete.
Please direct reply in the affirmative via email if you are interested and can provide the required product/service for this requirement. Please provide your capability statement, and letter of authorized supply and distribution and any other supportive documentation. I will accept responses for this Sources Sought until the 16th of August 2026 14:00, thanks.
GENERAL: C.W. Bill Young VA Medical Center Veterans Hospital, 10,000 Bay Pines Blvd Bay Pines, FL Â 33744, has a requirement for a new Raizer II Battery Mobile Lifting Chair Name Brand or Equal, and slings for patient lifts.
BACKGROUND: Outpatient clinics frequently experience patient falls involving individuals who cannot independently stand but are otherwise medically stable. Staff rely on manual lifting techniques that place them at high risk for injury and violate SPHM principles. This provides a controlled, mechanical method to raise a fallen patient from the floor to a seated position without manual lifting.
Fall recovery in CBOCS involves nursing assisting the veteran to a standing position or calling 911. Some patients just want nurses to assist them into a standing position after they have been cleared to get up. When staff allow a veteran to pull them on, we cannot control how much weight they are putting on staff. Fall recovery is mandated by Directive 1611 to have equipment. CBOCs do not have fall recovery equipment because they do not have the space. They need a recovery chair that is low profile.
The raiser chair was chosen after market research was completed.
The Raizer Lifting Chair will allow staff to get veterans up in a timely fashion, reduce potential for injury to veterans and staff and is small and compact and easy to store in the CBOC locations including Lee County PHYSICAL CHARACTERISTICS: Equipment must have the physical characteristics to enable the government to perform the capabilities: Raizer II Battery Mobile Lifting Chair Name Brand or Equal Lithium Ion Battery Requires only 1 caregiver Lifts in 20-30 seconds Includes a transport bag 300lb minimum lift capacity Rechargeable Charger: 12 V Battery indicator on panel Sound and light indicator for assembly Safe Working Load (SWL) (Maximum total load 150KG) Seat Width 25.7 cm- 27 inches No foam seats Number of lifts on a single charge- Minimum 75 Aluminum frame .FUNCTIONAL AND PERFORMANCE CHARACTERISTICS: Fall recovery devices that help lift a fallen person off the floor safely. Equipment must provide the functional and performance capability as listed above in section in above.
TRAINING: Contractor is to provide required training at installation of equipment (if applicable) and support for additional training as needed to VA staff. Government will not require additional training. Safe Patient Handling and Mobility Program Manager will then train staff at each CBOC location.
WARRANTY OF EQUIPMENT: 1-5-year maintenance warranty
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
Points of contact
- Michael A Shook, Contract SpecialistMichael.Shook@va.gov813-927-7566
Also open from this buyer
- FY26: MBC Sternudrive LiteTM; Model MBC 709-ModularSolicitationNAICS 339112Puerto Rico36C24926Q0926Closes todaySep 16
- Commercial Street VacuumCombined synopsis and solicitationSmall businessNAICS 333112Florida36C24826Q1249Closes tomorrowSep 17
- Street Debris BlowersCombined synopsis and solicitationSmall businessNAICS 333112Florida36C24826Q1251Closes in 2 daysSep 18
- PHARMACY IV PREP SYSTEMSources soughtNAICS 541519Puerto Rico36C24826Q1191_1Closes in 2 daysSep 18
- FY26: Artificial Intelligence Endoscopy ModuleSources soughtNAICS 334510Puerto Rico36C24826Q1222Closes in 2 daysSep 18