Skip to content
Abierto

Award notice, first published as special notice

FY26 Fluent Pro System

36C24826Q0117

Department of Veterans Affairs, 248-Network Contract Office 8. Electromedical and Electrotherapeutic Apparatus Manufacturing.

Awarded

Hologic Sales and Service, LLC

$22,500.00 obligated so far on USAspending

Description

As published on SAM.gov with the special notice of November 19, 2025.

INTENT TO SOLE SOURCE Please direct reply in the affirmative via email if you are interested and can provide the required product/service and proof of authorized servicing capabilities on the specific equipment listed for this requirement. Please provide your capability statement, I will accept responses for this Sources Sought until the 24th of November 2025 14:00 EDT, thanks.

1.Scope of Work: C.W. Bill Young Veterans Medical Center located at 10000 Bay Pines Blvd. Bay Pines; FL. 33744, is seeking procurement of one Fluent Pro System from Hologic Name Brand or Equal. This requirement needs to provide one Fluent Pro System (P/N: FLT-200).

2.Background: This unit is designed to optimize fluid control during hysteroscopic procedures. The current inventory EE#153579 has reached end of life and no longer meets the operational needs of staff.

3.Place of Performance: The product is requested to be delivered to Surgery Service, building 100, MOR. 10,000 Bay Pines Blvd, Bay Pines, Florida 33744, via the Warehouse Building 110 for Equipment.

4.Period of Performance: The product is requested to be delivered no later than December 2nd.

5.Type of Contract:

Supply: Firm, Fixed Price.

6.Requirement Overview: The Contractor shall provide the full requested quantity of products listed below. 6.1 Salient Characteristics NAME BRAND or EQUAL - Equipment Requirement:

Fluent Pro System (P/N: FLT-200). QTY.

1 - (P/N: FLT-200)

Fluent Pro System Equipment Requirement: Minimum Required Features and Specifications System Design and Operation Must be an automated fluid management system with both inflow and outflow (suction) regulation for hysteroscopic procedures. Must use SmartFlo or equivalent adaptive fluid control technology that automatically adjusts flow to maintain target intrauterine pressure. Must include touchscreen interface for real-time visualization of pressure, inflow/outflow volumes, and fluid deficit.

Must display real-time deficit values with visual and audible alerts when approaching safety thresholds. Must provide three selectable suction levels (Low, Medium, High) with the capability for rapid suction performance (up to 4× faster than standard Fluent system). Must allow for automatic balancing between inflow and outflow to maintain consistent cavity distention and visualization. Pressure and Flow Monitoring Must measure and display intrauterine pressure in mmHg with accuracy within ±5 mmHg.

Must regulate fluid inflow to maintain the surgeon-set pressure throughout resection and evacuation phases. Must allow user-defined safety limits for fluid deficit based on patient condition and procedure type. Integration and Compatibility Must be fully compatible with Hologic MyoSure® tissue-removal devices and accessories currently used at the C.W. Bill Young VAMC. Must support connection to standard wall suction or vacuum source without modification to facility plumbing.

Must operate with single-use, disposable tubing sets and FloPak fluid cartridges to ensure sterility and eliminate cross-contamination risk. Must not require custom hardware or external controller interfaces beyond standard operating room power and suction. Safety and Compliance Must provide visual and audible alarms for over-pressure, high deficit, occlusion, and flow interruptions. Must include a built-in safety shut-off to halt inflow if deficit exceeds the pre-set threshold.

Must comply with applicable FDA, IEC, and ISO medical electrical equipment standards. Must support use with sterile saline or electrolyte-based distension media. Physical and Utility Requirements Portable tabletop or cart-mounted configuration suitable for OR use. Electrical requirements: standard 120 V AC, 60 Hz hospital outlet.

Weight: 40 lb (for easy transport and setup). Must include holder or mount for inflow/outflow fluid bags and waste canister system. Must include integrated display with intuitive user interface for pressure, flow rate, and deficit monitoring. Accessories and Consumables Must include all manufacturer-recommended accessories necessary for installation, calibration, and operation. Must be compatible with existing facility sterilization and waste-handling protocols.

The contract, on USAspending

Federal procurement data the awarding office reported to FPDS, matched to this solicitation by its number.

UEI
Q1NBY5GKN9Z3
CAGE
5JP89
Vendor location
Marlborough, MA
Contract
36C24826P0222, purchase order
Obligated
$22,500.00
Actions
1 between December 2, 2025 and December 2, 2025
Competition
Not Competed, 1 offer received
Set-aside reported
No Set Aside Used.
Described as
Hologic-Fluent Pro System
Match
award number 36C24826P0222 equals the contract number; same awarding office 36C248 (high confidence)

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. November 19, 2025

    Special notice

    FY26 Fluent Pro System INTENT TO SOLE SOURCE

    Due November 24, 2025 at 2:00 PM EST. SAM.gov, notice f473f9e021bb43ff95179cdf1af62d34

  2. December 2, 2025

    Award notice, originally special notice

    Awarded to Hologic Sales and Service, LLC Marlborough 01752 for $22,500. SAM.gov, notice 12821efadfd5463aabcb93577090fa0a

Points of contact