Sources sought
Air Cooled Chiller Rental - Wilkes-Barre VAMC
36C24425Q0367
Department of Veterans Affairs, 244-Network Contract Office 4. Other Commercial and Industrial Machinery and Equipment Rental and Leasing.
Response deadline
February 26, 2025 at 12:00 PM EST
Closed 569 days ago. Posted February 18, 2025. Scheduled to archive April 27, 2025.
Description
As published on SAM.gov.
The following is a Sources Sought/Request for Information notice. This posted notice is not a Pre- Solicitation or Solicitation document. The government is not currently soliciting bids, quotes or proposals at this time; however, reserves the right to do so at a later date. The Wilkes-Barre VAMC in Wilkes-Barre, PA 18711 is seeking potential sources for the following services for Chiller Rental.
ALL WORK TO BE COMPLETED AT THE FOLLOWING LOCATION: Wilkes-Barre VAMC 1111 East End Blvd Wilkes-Barre, PA 18711 ALL INTERESTED PARTIES MUST ALSO HAVE AN ACTIVE REGISTRATION IN THE SYSTEM FOR AWARD MANAGEMENT (SAM) DATABASE. TO REGISTER, PLEASE VISIT WWW.SAM.GOV. Responses to this notice shall include:
Company Name Address Point of Contact Phone Number Email Address UEI Number CAGE Code Tax ID Number ** Note: In accordance with the U.S. Supreme Court decision regarding Kingdomware, service disabled veteran owned (SDVOSB) and veteran owned (VOSB), who are interested in this procurement and consider themselves to have the resources and capabilities necessary to provide these services shall be verified in Veteran Small Business Certification (VetCert) as follows to be considered: https://veterans.certify.sba.gov/ Process in 38 U.S.C.
8127(d) whereby a contracting officer of the Department shall award contracts on the basis of competition restricted to small business concerns owned and controlled by veterans, if the contracting officer has a reasonable expectation that two or more small business concerns owned and controlled by veterans will submit offers, and that the award can be made at a fair and reasonable price that offers the best value to the United States.
For purposes of this VA specific rule, a service-disabled veteran-owned small business (SDVOSB) or a veteran-owned small business (VOSB), must meet the eligibility requirements in 38 U.S.C. 8127(e), (f) and VAAR subpart 819.7003 and be listed as verified in the Vendor Information Pages (VIP) database. Please provide answers to all questions below regarding your firm s Socio-Economic status pursuant to North American Industrial Classification Code (NAICS)
532490:
1. Is your business a small business under NAICS 532490? YES
NO
2. Is your firm a Veteran-Owned Small Business? YES
NO
3. Is your firm a Service-Disabled Veteran-Owned Small Business? YES
NO
4. Is you firm a certified HUB Zone firm? YES
NO
5. Is your firm a Woman Owned business? YES
NO
6. Is your firm a Large Business? YES
NO
7. Do you have a GSA/FSS schedule for these items? YES
NO
Schedule Number:
Expiration Date:
Please provide a capability statement as well as any relevant literature addressing your organizations ability to supply the required items. Also, please include a point of contact name, phone number and email address.
Note: Questions regarding this notice should be addressed to Jennifer Beiswenger via email only. NO PHONE CALLS WILL BE ACCEPTED REGARDING THIS REQUIREMENT. Please submit all responses to this notice via e-mail to:
Jennifer Beiswenger Contract Specialist Jennifer.Beiswenger@va.gov Responses to this Sources Sought Notice are required by no later than Wednesday, February 26, 2025, at 12:00 pm EST. Introduction 1.0 The Wilkes Barre VAMC is a mission critical facility and is located at 1111 East End Boulevard, Wilkes Barre PA. This facility has a requirement for supplementing the existing main chiller system during the upcoming cooling season.
This will be accomplished by connecting air-cooled stand-alone chillers to the existing taps. The requirement will be for a period of seven (7) months beginning, April 1, 2024, and ending October 31, 2024. Scope 2.0 2.1 This requirement is for supplying two (2) 500-ton air cooled chillers to support the main chiller plant and one (1) 250-ton air-cooled chiller that will support the North building at this facility. The chillers at the main plant will need to be supported electrically by a standby generator.
The chiller for the North building will need to be electrically connected to the twist lock electrical panel that is connected to this facility s 1200 AMP electrical utility. Equipment Requirements 3.0 3.1 The air-cooled chillers for the main plant shall have a capacity of 500 tons each. 3.2 The air-cooled chiller for the North building shall have a capacity of 250 tons. 3.3 Each chiller shall be programable and automated to maintain a chilled water setpoint. 3.4 Each chiller shall have an onboard pumping system.
3.3 Each chiller and generator shall be trailer mounted. 3.4 Diesel powered generator with manual start capable of providing power to run two 500-ton air-cooled chiller. Contractor Requirements 4.0 4.1 Contractor shall include delivery and pick-up of equipment. 4.2 The contractor is responsible for setting the equipment in the areas designated by the Wilkes Barre VAMC. 4.3 The contractor is responsible for supplying the interconnecting chilled water lines between the equipment and the existing system taps.
Note: The existing system taps are six inch (6 ) grooved type connections and are within two hundred fifty feet (250 ) of equipment location site. 4.4 The contractor shall install and fill all interconnecting chilled water lines. 4.5 The contractor shall supply and terminate interconnecting electrical cabling between the generator and the two 500-ton chillers.
4.6 The contractor shall supply and terminate interconnecting electrical cabling between the building 1200 AMP utility (Twist lock connections) and the 250-ton chiller. 4.7 The contractor shall provide start-up and operational training to the VAMC maintenance personnel. 4.8 The contractor shall assume 24/7 equipment runtime. 4.9 The contractor shall provide required periodic maintenance on all equipment. 4.10 The contractor shall provide 24/7 emergency service on the equipment provided.
5.0 Deliverables 5.1 The contractor shall place all equipment onsite to minimize interconnecting piping and cabling length requirements. 5.2 All equipment and deliveries and pickups must be scheduled with the Maintenance and Operations Supervisor two weeks in advance. 5.3 All equipment deliveries and pickups must be conducted before 7:00AM. 5.4 All work shall be performed Monday through Friday during Operation Hours Only (6:00 AM- 5:00 PM). No work shall be conducted on Federal Holidays and/or Weekends.
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
February 18, 2025
Sources sought
Due February 26, 2025 at 12:00 PM EST. SAM.gov, notice 4325d184c10d40fb81e434be810f18b0
Points of contact
- Jennifer Beiswenger, Contract Specialistjennifer.beiswenger@va.gov814-932-6914
Also open from this buyer
- Butler GP-9 NO x TestingCombined synopsis and solicitationNAICS 541380Butler, PA36C24426Q0872Closes todaySep 18
- RFQ - GI Video Integration SystemSolicitationNAICS 339112Philadelphia, PA36C24426Q0951Closes todaySep 18
- Medical Gas Preventative Maintenance and Inspection Services for Erie VA Medical CenterPresolicitationSDVOSBNAICS 81121036C24426Q0958Closes in 3 daysSep 21
- Hood Inspection and Certification for Laboratory ServicePresolicitationNAICS 541380Philadelphia, PA36C24426Q0840Closes in 3 daysSep 21
- Philadelphia VA Medical Center RadiopharmacueticalsSolicitationNAICS 325412Philadelphia, PA36C24426Q0961Closes in 3 daysSep 21