Sources sought
AngioDynamics Pro Laser This is Not a Request for Quote
36C24424Q0643
Department of Veterans Affairs, 244-Network Contract Office 4. Surgical Appliance and Supplies Manufacturing.
Response deadline
May 3, 2024 at 12:00 PM EDT
Closed 867 days ago. Posted April 23, 2024. Scheduled to archive May 6, 2024.
Description
As published on SAM.gov.
STATEMENT OF NEED ANGIODYNAMICS PRO LASER Description of Use: The Corporal Michael J. Crescenz VA Medical Center is in need of (1) endovenous laser treatment system and (1) infiltration pump, which is critical for use in the Interventional Radiology section. Objective The Corporal Michael Crescenz VA Medical Center (CMCVAMC) intends to procure an endovenous laser treatment system and (1) infiltration pump for the facility s Interventional Radiology department.
This document highlights the technical specifications and services being requested by the facility for consideration towards purchase of an endovenous laser. Vendors under this proposal shall provide all equipment and accessories, installation services, and project management support.
Minimum Technical Specifications: The endovenous laser treatment and infiltration pump system shall meet the following minimum specifications: Achieves optimal vein ablation 1470nm wavelength laser Water-specific, diode laser Targeted energy of 30-50 joules/cm Maximum power of 15 watts Easy-to-use controls Ability to track pull-back through audible alarms/sounds Ability to program the laser for specific fiber types Internal sensors to monitor settings (eg. wattage, energy output) Aiming beam has multiple modes Real-time on-screen display of settings Foot pedal Pump that provides high-speed infiltration into vessels Infiltrates up to 1,100 ml per minute, or better Vibration free unit Tubing can be easily mounted.
Emergency shut off. 110v Class 4 laser Safety glasses Keys Warning signs Spare fuse(s) Test fiber(s) Remote interlock connectors Power cord 3 year warranty Optional/Value Added Features: Loaner program Multi-media card Required Interfaces: The infiltration pump must be compatible with the endovenous laser treatment unit.
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
April 23, 2024
Sources sought
Due May 3, 2024 at 12:00 PM EDT. SAM.gov, notice 107c9be92bd5423b8d5d3db4d43a4d07
Points of contact
- Sherrie Thompson, Contact Specialistsherrie.thompson2@va.gov215-823-5800 ext. 205831
Also open from this buyer
- FDG RadiopharmaceuticalCombined synopsis and solicitationNAICS 32541236C24426Q0900Closes todaySep 17
- Butler GP-9 NO x TestingCombined synopsis and solicitationNAICS 541380Butler, PA36C24426Q0872Closes tomorrowSep 18
- RFQ - GI Video Integration SystemSolicitationNAICS 339112Philadelphia, PA36C24426Q0951Closes tomorrowSep 18
- Medical Gas Preventative Maintenance and Inspection Services for Erie VA Medical CenterPresolicitationSDVOSBNAICS 81121036C24426Q0958Closes in 4 daysSep 21
- Hood Inspection and Certification for Laboratory ServicePresolicitationNAICS 541380Philadelphia, PA36C24426Q0840Closes in 4 daysSep 21