Sources sought, total small business set-aside
561-24-3-2238-0173 | 36C242-24-AP-3435 AHBPCE - Hypair (VA-24-00089836)
36C24224Q0905
Department of Veterans Affairs, 242-Network Contract Office 02. Electromedical and Electrotherapeutic Apparatus Manufacturing.
Response deadline
August 19, 2024 at 3:00 PM EDT
Closed 759 days ago. Posted August 12, 2024. Scheduled to archive October 18, 2024.
Description
As published on SAM.gov.
VHA Regional Procurement Office-East NETWORK CONTRACTING OFFICE 2 Albany-Stratton/Bath/Bronx/Canandaigua/Northport/Syracuse Medical Centers Hudson Valley/New Jersey/New York Harbor Healthcare Systems WNY Upstate New York Healthcare System Page 2 of 2 Department of Veterans Affairs, Network Contracting Office 2, is issuing this Notice of Intent to Sole Source to identify any potential sources that have the resources and capabilities to provide a comprehensive vehicle for.
SERVICES REQUIRED This MGC Hypair is replacing equipment which was previously purchased in 2017. This will provide an additional pulmonary function evaluation suite to be used for research testing at the Airborne Hazards and Burn Pits Center of Excellence (AHBPCE) at the New Jersey War Related Illness and Injury Study Center (WRIISC). The Hypair System will provide a unique DLCO-NO dual diffusion method for assessing gas exchange in veterans.
This device will allow the AHBPCE to quantify diffusion capacity for deployed veterans. Specifications Hardware Hardware Full MGC Pulmonary Function Expair II Software Physical Dimensions Module (H x W x D)
Weight: cm 13,7 x 40 x 34 inches 5,4 x 15,7 x 13,3 12 Kg 26,5 lbs. Physical Dimensions Trolley (H x W x D)
Weight: Power supply: cm 140 x 73 x 55 (standing) inches 55 x 28,7 x 21,7 35 Kg 77 lbs. 230 VAC 50 Hz or 115 VAC 60 Hz Power consumption: 100 VA (module) Warmup time: 20 min. Meets all electrical safety requirements:
EN60601-1 Classification:
IIa CE MARK:
MDD: CE 1434 93/42/EC and harmonized standards Computer interfacing: Windows 10 Pro Serial interface RS232 USB 2.0 / 3.0 Ambient conditions for use Temperature: 10 - 35°C Relative humidity: 25 to 85 % (non-condensed) Barometric pressure: No restriction Features Double Gas (CO-NO) testing Expair II software preVent flow sensor. Patient report capability Standard and use defined protocols. Place of Performance Vendor to deliver and install equipment to VANJHCS East Orange Campus (11-190).
385 Tremont Ave Bldg 1, rm 11-190 East Orange, NJ 07018 INTERESTED & CAPABLE RESPONSES: NCO 2 is seeking responses from businesses that are interested in this procurement and consider themselves to have the resources, rights, and capabilities necessary to provide these services.
Please respond with your: Business name, business type, socio-economic status (e.g., Veteran-Owned, Woman-Owned, Disadvantaged Small Business, 8(a), etc.), person of contact (including telephone number & email address), GSA Contract number if applicable, and DUNS number. Capability statement must provide detailed and specific information that would demonstrate a capability to perform the tasks as stated in the attached Statement of Work.
Failure to tailor capability statement to this specific requirement may result in your company being determined non-responsive. Responses must be submitted by 3:00 PM EST August 19, 2024. Responses to the information requested above may be submitted via email to William.Brewington@va.gov. This Special Notice of Intent to sole source is for planning purposes ONLY.
The results of this notice will assist in the development of (1) the requirement, and (2) the acquisition strategy (e.g., small business set-aside, full and open competition, etc.). VA assumes no responsibility for any costs incurred associated with the preparation of responses submitted as a result of this notice.
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
August 12, 2024
Sources sought
Due August 19, 2024 at 3:00 PM EDT. SAM.gov, notice d38a8e016c694b5f8ececa7546964c76
Points of contact
- William S Brewington (Contractor), Contractor SupportWilliam.Brewington@va.gov651-293-3017
Also open from this buyer
- Castle Point PT Flooring ReplacementSolicitationSDVOSBNAICS 238160Montrose, NY36C24226Q0920Closes tomorrowSep 18
- Urgent Chiller Plant PRV Valve 2 Repair Samuel S. Stratton (Albany) VAMCPresolicitationNAICS 238220Albany, NY36C24226Q0942Closes tomorrowSep 18
- SomnoFlo Electronic Vaporizer Systems Brand Name or EqualCombined synopsis and solicitationNAICS 334516East Orange, NJ36C24226Q0971Closes tomorrowSep 18
- Boiler Rental - VA Hudson Valley HCS Montrose CampusSources soughtNAICS 238220Montrose, NY36C24227Q0018Closes tomorrowSep 18
- 561A4-25-500 Elevator Upgrade & Modernization Repairs at VA NJ HCS Lyons Buildings 6 & 53Combined synopsis and solicitationSDVOSBNAICS 238290Lyons, NJ36C24226R0097Closes tomorrowSep 18