FY24 Service - BUF/BAT Kitchen Hood Cleaning & Fire Suppression System Inspections (Base + 4)

36C24224Q0775

Department of Veterans Affairs, 242-Network Contract Office 02. Other Services to Buildings and Dwellings.

Awarded

Davis-Ulmer Sprinkler Company, Inc.

$122,824.31 obligated so far on USAspending

Description

As published on SAM.gov.

The purpose of this amendment is to extend the closing date and answer Contractor questions pertaining to Solicitation 36C24224Q0775. Quote submissions shall now be submitted on or before Wednesday, July 31st, 2024, 12:00pm EST. Buffalo VA Medical Center: How many access panels are located throughout the ductwork (canteen)? There is roughly 18, one every 8 feet. Are grease pads to be used during the cleaning in the canteen and kitchen exhaust hood room? Yes Are the floors to be cleaned after service?

Yes, if the contractor makes a mess on the floor they shall clean it up. Will water supply disposal sink be provided in kitchen and canteen exhaust room? Yes, a hose will be hooked up from the designated canteen spicket from outside, located on the west corner of the building. The hose bib designated for the main kitchen is located on the other side of the building (at the back of the kitchen, near the stairwell). Who do we meet with upon arrival at site?

The contractor will meet with the designated VA HVAC employee when arriving on site. Where should before and after photos be sent? Before and after photos of service will be sent to the COR, Jerome Okonzak s email, jerome.okonzak@va.gov. How does the main kitchen ductwork run throughout the hood? The ductwork runs completely through the main kitchen hood into the offices located in the main kitchen. Do not have to go in through the hood. What is the confined space permit for?

The confined space permit is required for the Ansul systems in the main kitchen. They are located inside of the hood that requires the person to get into and therefore are a permit required confined space. Are there any access panels in the offices located in the main kitchen? No, there are no access panels in the offices located in the main kitchen. Is there anything being cooked with grease in the main kitchen? No, only steam. What are the measurements for the hood located at the VA Day Treatment Center?

Roughly 6X10 ft. Are the filters disposable? The only filters that are disposable are located on floor 9A of the Buffalo VA and at the VA Day Treatment Center. Are filters provided? No. Which filter needs to be changed (in reference to hood on 9A)? The paper pleated disposable filter need to be changed every time a cleaning occurs. The Buffalo VA is responsible for the metal filter that is located inside the hood. Is the Hazmat Shed a clean agent system?

Is there cleaning involved with the Hazmat Shed or only inspection? The Hazmat Shed is Kidde System, one for fire suppression (left) and one for chemical storage (right). (See SOW for specs)

Batavia VA Medical Center: Where is the access panel for the main kitchen hood located? Above the main kitchen hood which can be accessed via designated stairwell along the back wall. Are there any water drains? There are floor drains surrounding the main kitchen hoods. Do the hoods located in the Spruce and Maple Lodges have disposable filters? No. Are the hood systems in the canteen and building five (5) decommissioned? Yes. Is there a loading dock that can be used to access the main kitchen? Yes, a back loading dock with two (2) elevators at the rear of buildings one (1) and two (2).

The contract, on USAspending

Federal procurement data the awarding office reported to FPDS, matched to this solicitation by its number.

UEI
NHLABGL1UVJ3
CAGE
31UU8
Vendor location
Amherst, NY
Contract
36C24224P1657, purchase order
Obligated
$122,824.31, potential $210,668
Actions
7 between August 20, 2024 and June 15, 2026
Competition
Competed Under SAP, 1 offer received
Set-aside reported
No Set Aside Used.
Described as
Semi-Annual Cleaning and Inspection of Kitchen Hoods and Fire Suppression Systems
Match
solicitation number 36C24224Q0775 equals the FPDS solicitation identifier; same awarding office 36C242 (high confidence)

Publications

Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.

  1. June 28, 2024

    Presolicitation

    Due July 4, 2024 at 12:00 PM EDT. SAM.gov, notice 88dc7a6bb2d54b12acd21df300d61768

  2. July 8, 2024

    Solicitation, originally presolicitation

    Due July 19, 2024 at 12:00 PM EDT. SAM.gov, notice 49cc0c89c2a247c8ac016b489b290776

  3. July 26, 2024

    Solicitation

    Due July 31, 2024 at 12:00 PM EDT. SAM.gov, notice a326e0559b2e4aaa9707d9771187d597

Points of contact