Special notice
Intent to Sole Source Lucas 3, v3.1 Chest Compression System
36C24224Q0135
Department of Veterans Affairs, 242-Network Contract Office 02. Surgical and Medical Instrument Manufacturing.
Response deadline
December 18, 2023 at 3:00 PM EST
Closed 1004 days ago. Posted January 19, 2024. Scheduled to archive February 16, 2024.
Description
As published on SAM.gov.
This is a notice of intent to award a sole source contract and is not a request for quotes. The Department of Veterans Affairs, VISN 2, Finger Lakes Health Care System, Bath Campus intends to award a Firm Fixed Price (FFP), brand name only, sole source action.
Name of Contractor:
Stryker Medical Street Address:
PO Box 93308 City, State, Zip:
Chicago, IL 60673-3308 GENERAL INFORMATION Title of Project: Lucas 3, v3.1 Chest Compression System with Accessories Type of Contract Contemplated: Firm Fixed Price SCOPE One (1) each brand name only Lucas 3, v3.1 Chest Compression System with Accessories for the VA Finger Lakes Health Care System Fire Department Paramedics.
REQUIREMENT/SALIENT CHARACTERISTICS/SPECIFICATIONS Common Nomenclature: Lucas 3, v3.1 Chest Compression System Intended use: One (1) each brand name only Lucas 3, v3.1 Chest Compression System for the VA Finger Lakes Health Care System Fire Department Paramedics. Other pertinent information that describes the item, material or service required: One (1) Each LUCAS 3, v3.1 Chest Compression System, Part #:
99576-000063 System Includes:
- Hard Shell Case - Slim Back Plate - (2) Patient Straps - (1) Stabilization Strap - (2) Suction Cups - (1) Rechargeable Battery and instruction for use.
Accessories: One (1) LUCAS External Power Supply, Part #: 11576-000071 One (1) LUCAS 3 Battery Dark Grey Rechargeable LiPo, Part #: 11576-000080 One (1) LUCAS Disposable Suction Cup (3-Pack), Part #: 11576-000046 One (1) LUCAS Grip Tape for Slim Back Plate, Part #: 11576-000089OTHER UNIQUE ADDITIONAL CHARACTERISTICS REQUIREMENTS The device must be capable of operating off battery or A/C power supply in the even of extended transport or battery failure.
The device must be a 2-piece design with the smaller piece being rigid and being able to be slid under the patient without having to log roll the patient. The device must be capable of fitting horizontally into a storage cabinet no more than 26 wide. The device assembled dimensions must be no more then 22 x 20.5 x 9.4 inches, and in the carrying case 22.8 x 13 x 10.2 inches. The device must be compact and portable, suitable for various settings, including pre-hospital and in-hospital use.
The device must have an ease of application and quick set up, facilitating rapid deployment during emergencies. The device must be a motorized piston, so all the load is directed at the heart. The device must limit the ability of having to log roll a patient during application. Should be able to lift the patient s torso and slide the back plate under from the head. Log rolling a patient on to a chest compression system can waste valuable time.
The device must have less than 10 second interruptions when transitioning from manual to mechanical CPR. The device must adhere to established guidelines and protocols, ensuring compatibility with standard resuscitation practices. The device to have real time feedback features to assist users in optimizing compression quality. The device must have a rate of compression of 102 +/- two compressions per minute. The device must not have a patient weight limit.
The chest height can be between 6.7 to 11.9 inches with a maximum chest width of 17.7 inches. DELIVERY Items will be delivered to the Department of Veterans Affairs, VISN 2, Finger Lakes Health Care System, Bath Campus. Government-Furnished Property, Material, Equipment, or Information (GFP, GFM, GFE, or GFI): None SECURITY No special security needed SPECIAL MATERIAL REQUIREMENT No special material needed.
PLACE OF PERFORMANCE The Department of Veterans Affairs, VISN 2, Finger Lakes Health Care System, Bath Campus PERIOD OF PERFORMANCE 180 days ARO BILLING/INVOICING: Billed upon receipt of product.
CUSTOMER INFORMATION: None This notice of intent to sole source is not a request for quotes; however, all responsible sources may submit a capability statement which shall be considered by the Government. All capability statements must be received by no later than 3:00 PM Eastern Standard Time on January 22, 2024. Responses to be submitted to Chad M. Johnson, Contracting Officer at chad.johnson4@va.gov. A determination by the Government not to compete this proposed contract based on responses to this notice is solely within the discretion of the Government.
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
January 19, 2024
Special notice
Due December 18, 2023 at 3:00 PM EST. SAM.gov, notice 84b2c23be9a94668bf1c6bc8351d1eba
Points of contact
- Chad M. Johnson, Contracting Officerchad.johnson4@va.gov(718) 836-6600 ext 6766
Also open from this buyer
- Castle Point PT Flooring ReplacementSolicitationSDVOSBNAICS 238160Montrose, NY36C24226Q0920Closes tomorrowSep 18
- Urgent Chiller Plant PRV Valve 2 Repair Samuel S. Stratton (Albany) VAMCPresolicitationNAICS 238220Albany, NY36C24226Q0942Closes tomorrowSep 18
- SomnoFlo Electronic Vaporizer Systems Brand Name or EqualCombined synopsis and solicitationNAICS 334516East Orange, NJ36C24226Q0971Closes tomorrowSep 18
- Boiler Rental - VA Hudson Valley HCS Montrose CampusSources soughtNAICS 238220Montrose, NY36C24227Q0018Closes tomorrowSep 18
- 561A4-25-500 Elevator Upgrade & Modernization Repairs at VA NJ HCS Lyons Buildings 6 & 53Combined synopsis and solicitationSDVOSBNAICS 238290Lyons, NJ36C24226R0097Closes tomorrowSep 18