Combined synopsis and solicitation, total small business set-aside
Preventative Maintenance and Calibration Service for Horizontal Tensile Tester
2031ZA24Q00227
Bureau of Engraving and Printing, Office of the Chief Procurement Officer. Electronic and Precision Equipment Repair and Maintenance.
Response deadline
August 23, 2024 at 3:00 PM EDT
Closed 756 days ago. Posted August 14, 2024, first published June 5, 2024. Scheduled to archive September 7, 2024.
Description
As published on SAM.gov.
The Bureau of Engraving and Printing (BEP) located in Washington, DC has Preventative Maintenance and Calibration Service requirement for the Horizontal Tensile Tester. The Horizontal Tensile Tester is required to perform the tensile test suitable for testing tensile strength of film, sheet, paper, paperboard, etc. The BEP requires the equipment to perform tensile strength testing for papers that are frequently handled such as currency (bank note) paper, non-distinctive banknote paper and miscellaneous materials.
The Tensile Strength Test is performed according to TAPPI method T 494. Tensile Strength is the maximum load that a material can support without fracture when being stretched, divided by the original cross-sectional area of the material.
The equipment will be used to test the paper under certain conditions and/or to test the physical properties of Distinctive Currency Paper, non-distinctive paper, and various other materials to determine if they meet specification requirements necessary to perform successfully on printing presses, to manufacturer currency notes acceptable to our customers, and for various other uses in the daily operation of manufacturing the currency notes and other products.
This is being done to manufacturer products that are acceptable to our customers. The test equipment is used at the Bureau of Engraving DCF Facility in Washington DC. The new equipment and the Preventative Maintenance and Calibration Services will ensure that the equipment can be operated in optimum condition on any business day to deliver a product or analysis data supporting multiple projects.
The Preventative Maintenance and Calibration Service is to be conducted annually to ensure the reliability and reproducibility of results when performing the Horizontal Tensile Test. See Attachment A – Performance Work Statement (PWS).
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
June 5, 2024
Combined synopsis and solicitation
Due June 28, 2024 at 3:00 PM EDT. SAM.gov, notice 43e226ce35ca4754a91cecca8b5ae204
June 18, 2024
Combined synopsis and solicitation
Due June 28, 2024 at 3:00 PM EDT. SAM.gov, notice dee6a3be109c42ce815c4e2797b56eec
June 30, 2024
Combined synopsis and solicitation
Due July 5, 2024 at 3:00 PM EDT. SAM.gov, notice 35ce5301c6fe4853b52d8134103a4560
August 14, 2024
Combined synopsis and solicitation
Due August 23, 2024 at 3:00 PM EDT. SAM.gov, notice ef853cbf6a454e8186cd8189c0105890
Points of contact
- Genevieve ColvinGenevieve.Colvin@bep.gov
- Sonia BarnhillSonia.Barnhill@bep.gov
Also open from this buyer
- SPARE PARTSCombined synopsis and solicitationSmall businessNAICS 332913Washington, DC2031ZA26Q00158Closes in 3 daysSep 21
- Asbestos Abatement ServicesSources soughtNAICS 562910Washington, DC2031ZA26N00066Closes in 7 daysSep 25
- Sources Sought Notice – DCF Mail and Packages Screening EquipmentSources soughtNAICS 334517Washington, DC2031ZA26N00061Closes in 12 daysSep 30
- DCF NS-LEPE Site PreparationSources soughtSmall businessNAICS 238910Washington, DCNS-LEPE_Sources_SoughtCloses in 14 daysOct 2
- Cooling Tower, Roofing, and Structural ConstructionSolicitationSmall businessNAICS 236220District of Columbia2031ZA26R00027Closes in 21 daysOct 9