Sources sought
LI-COR LI-7820 N2O/H2O Trace Gas Analyzer, Analyzer T-split Tubing, and 3-year all inclusive service agreement
12405B25Q0007
Agricultural Research Service, USDA ARS Sea Aao Acq/Per Prop. Analytical Laboratory Instrument Manufacturing.
Response deadline
October 28, 2024 at 5:00 PM EDT
Closed 689 days ago. Posted October 21, 2024, first published October 21, 2024. Scheduled to archive November 12, 2024.
Description
As published on SAM.gov.
1. Type of Notice: This is a SOURCES SOUGHT NOTICE ONLY. This is NOT a solicitation for proposals or quotes and does not obligate the Government to award a contract. This notice is for informational and planning purposes only and shall not be construed as a solicitation or an obligation or commitment by the Government, nor is it a Request for Proposal (RFQ) at this time. Responses to this Notice must be in writing.
2. Purpose: The purpose of this Sources Sought Notice is to conduct market research to determine, in particular; the capability of sam.gov registered Small Business entities to provide the commercial supply described below. ARS will accept responses from ALL socioeconomic categories in order to gain a more complete understanding of the market for these supplies.
3. Requirement Description: 3.1.
Requirement Location: See Place of Performance above. 3.2. The USDA-ARS has a need for a Trace Gas Analyzer.
1.0 Specifications Description:
Measurement Technique: OF-CEAS (Optical Feedback – Cavity Enhanced Absorption Spectroscopy)
Measurement Rate: 1 sample per second (1 Hz)
Optical Cavity Volume: 6.41 cm3 Flow Rate: 250 sccm nominally in Standard Configuration 150 sccm nominally in High Altitude Configuration 70 sccm nominally in Reduced Flow Rate Configuration with installed kit Total Weight: 10.5 kg (including batteries)
Case Dimensions: 51 cm × 33 cm × 18 cm (L × W × H)
Operating Temperature Range: -25 °C to 45 °C (without solar load, under normal operating conditions)
Operating Humidity Range: 0 to 85% RH (non-condensing, without solar load, under normal operating conditions)
Sample Line Humidity Range: 0 to 99.9% non-condensing Operating Pressure Range: 70 to 110 kPa in Standard and Reduced Flow Rate Configurations 50 to 110 kPa in High Altitude Configuration Connectivity: Ethernet and Wi-Fi (not available in some countries)
Wi-Fi Compatibility: 2.4 GHz, 802.11 a/b/g/n/ac Power Consumption:
Steady State Operation: 22 Watts at 25 °C without batteries charging Warmup: Up to 65 W without batteries charging; up to 100 W with batteries charging Off: Up to 2.3 W when powered from pins 3 and 4 without batteries charging; up to 0.2 W when powered from pins 1 and 5 without batteries charging Power Supply Requirements:
Pins 1 and 5 (24 VDC Input): Minimum 6 A at 24 V Pins 3 and 4 (10.5 to 33 VDC Input): Minimum 14 A at 10.5 VDC;
6 A at 24 VDC Power Supply:
Universal Power Adapter (Input: 100 to 240 VAC, 50-60 Hz;
Output: 24 VDC)
Battery Life: 8 hours typical with 2 batteries LI-COR 7820 Quantity:
1 Unit
Type:
Each Minimum Requirements: High-precision N2O analyzer that is portable for use in soil flux measurements and atmospheric monitoring. Analyzer T-Split Tubing 9982-073 Quantity:
1 Unit
Type:
Each Minimum Requirements: Use LI-7820 with both the LI-780 and Smart Chamber at the same time Incidental Services: 3-year Service agreement to include:
free replacement or extensive damage, water damage coverage, impact damage coverage, voltage damage coverage, defective parts coverage, priority service, free shipping from Li-Cor to customer, free calibration, free cavity replacements for trace gas analyzers Additional Requirements Warranty against manufacturing defects.
Publications
Every notice SAM.gov issued under this solicitation number, oldest first. Each is a separate record on SAM.
Points of contact
- Cecilia McNameececilia.mcnamee@usda.gov9852328289