{"canonical":"https://abierto.us/opportunities/w912pl24b0008","key":"W912PL24B0008","url":"https://abierto.us/opportunities/w912pl24b0008","title":"VA GLA WATERLINES REPLACEMENT PROJECT","solicitation_number":"W912PL24B0008","notice_type":"o","open":false,"response_deadline":"2024-08-06T20:00:00Z","first_posted":"2024-05-31","last_posted":"2024-08-22","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE ARMY","office":"W075 ENDIST LOS ANGELES","naics":"237110","psc":"C221","set_aside":"SDVOSBC","place_state":"CA","place_county":"06037","place_county_name":"Los Angeles County","place_city":"0644000","place_city_name":"Los Angeles","winner":"BORJA ENGINEERING & CONSTRUCTION, INC","award_amount":null,"publications":[{"notice_id":"19d340c652504cc69fbecafba6230ef9","title":"VA GLA WATERLINES REPLACEMENT PROJECT","solicitation_number":"W912PL24B0008","notice_type":"p","base_type":"p","posted":"2024-05-31","posted_at":null,"due_at":"2024-07-18T20:00:00Z","due_date":"2024-07-18","cancelled":null,"archived":null,"archive_date":"2024-06-13","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/19d340c652504cc69fbecafba6230ef9/view","enriched":false,"history":[]},{"notice_id":"cb479591a6eb43a0a9d30c172a1c01de","title":"VA GLA WATERLINES REPLACEMENT PROJECT","solicitation_number":"W912PL24B0008","notice_type":"p","base_type":"p","posted":"2024-05-31","posted_at":null,"due_at":"2024-07-18T20:00:00Z","due_date":"2024-07-18","cancelled":null,"archived":null,"archive_date":"2024-08-02","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/cb479591a6eb43a0a9d30c172a1c01de/view","enriched":false,"history":[]},{"notice_id":"0f606826912748fc94125344cebf5853","title":"VA GLA WATERLINES REPLACEMENT PROJECT","solicitation_number":"W912PL24B0008","notice_type":"o","base_type":"o","posted":"2024-06-13","posted_at":null,"due_at":"2024-07-18T20:00:00Z","due_date":"2024-07-18","cancelled":null,"archived":null,"archive_date":"2025-06-13","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/0f606826912748fc94125344cebf5853/view","enriched":false,"history":[]},{"notice_id":"20d504813430415c8e660a91e8cb998c","title":"VA GLA WATERLINES REPLACEMENT PROJECT","solicitation_number":"W912PL24B0008","notice_type":"o","base_type":"o","posted":"2024-06-26","posted_at":null,"due_at":"2024-07-18T20:00:00Z","due_date":"2024-07-18","cancelled":null,"archived":null,"archive_date":"2025-06-27","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/20d504813430415c8e660a91e8cb998c/view","enriched":false,"history":[]},{"notice_id":"9c23b855d3ff4421aff95e8e4eff0f13","title":"VA GLA WATERLINES REPLACEMENT PROJECT","solicitation_number":"W912PL24B0008","notice_type":"o","base_type":"o","posted":"2024-07-17","posted_at":null,"due_at":"2024-07-23T20:00:00Z","due_date":"2024-07-23","cancelled":null,"archived":null,"archive_date":"2025-07-17","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/9c23b855d3ff4421aff95e8e4eff0f13/view","enriched":false,"history":[]},{"notice_id":"912567c802a940a9b1788b1d8ad0a943","title":"VA GLA WATERLINES REPLACEMENT PROJECT","solicitation_number":"W912PL24B0008","notice_type":"o","base_type":"o","posted":"2024-07-22","posted_at":null,"due_at":"2024-07-30T20:00:00Z","due_date":"2024-07-30","cancelled":null,"archived":null,"archive_date":"2025-07-22","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/912567c802a940a9b1788b1d8ad0a943/view","enriched":false,"history":[]},{"notice_id":"aac42e9430764609afeab789866f17cf","title":"VA GLA WATERLINES REPLACEMENT PROJECT","solicitation_number":"W912PL24B0008","notice_type":"o","base_type":"o","posted":"2024-07-22","posted_at":null,"due_at":"2024-07-30T20:00:00Z","due_date":"2024-07-30","cancelled":null,"archived":null,"archive_date":"2025-07-23","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/aac42e9430764609afeab789866f17cf/view","enriched":false,"history":[]},{"notice_id":"59a5ac32bd8e40dc9bf52937da178950","title":"VA GLA WATERLINES REPLACEMENT PROJECT","solicitation_number":"W912PL24B0008","notice_type":"o","base_type":"o","posted":"2024-07-23","posted_at":null,"due_at":"2024-07-30T20:00:00Z","due_date":"2024-07-30","cancelled":null,"archived":null,"archive_date":"2025-07-24","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/59a5ac32bd8e40dc9bf52937da178950/view","enriched":false,"history":[]},{"notice_id":"3b9ca67660a44869966ad132c6571c12","title":"VA GLA WATERLINES REPLACEMENT PROJECT","solicitation_number":"W912PL24B0008","notice_type":"o","base_type":"o","posted":"2024-07-29","posted_at":null,"due_at":"2024-08-06T20:00:00Z","due_date":"2024-08-06","cancelled":null,"archived":null,"archive_date":"2025-07-29","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/3b9ca67660a44869966ad132c6571c12/view","enriched":false,"history":[]},{"notice_id":"90d44ffe77be4d67abce78d26409741b","title":"VA GLA WATERLINES REPLACEMENT PROJECT","solicitation_number":"W912PL24B0008","notice_type":"o","base_type":"o","posted":"2024-08-01","posted_at":null,"due_at":"2024-08-06T20:00:00Z","due_date":"2024-08-06","cancelled":null,"archived":null,"archive_date":"2025-08-01","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/90d44ffe77be4d67abce78d26409741b/view","enriched":false,"history":[]},{"notice_id":"62b6ddef1a67479c8bde48f0fa16ff26","title":"VA GLA WATERLINES REPLACEMENT PROJECT","solicitation_number":"W912PL24B0008","notice_type":"o","base_type":"o","posted":"2024-08-06","posted_at":null,"due_at":"2024-08-06T20:00:00Z","due_date":"2024-08-06","cancelled":null,"archived":null,"archive_date":"2025-08-01","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/62b6ddef1a67479c8bde48f0fa16ff26/view","enriched":false,"history":[]},{"notice_id":"a6314e4a78534d5d8cb02604ae526304","title":"VA GLA WATERLINES REPLACEMENT PROJECT","solicitation_number":"W912PL24B0008","notice_type":"o","base_type":"o","posted":"2024-08-22","posted_at":null,"due_at":"2024-08-06T20:00:00Z","due_date":"2024-08-06","cancelled":null,"archived":null,"archive_date":"2025-08-01","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/a6314e4a78534d5d8cb02604ae526304/view","enriched":false,"history":[]}],"latest_notice_id":"a6314e4a78534d5d8cb02604ae526304","first_type":"p","notices":[{"dates":{"posted":"2024-05-31","response_deadline":{"raw":"2024-07-18T13:00:00-07:00","utc":"2024-07-18T20:00:00Z","date":"2024-07-18","time":"13:00:00","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/19d340c652504cc69fbecafba6230ef9/view"},"naics":{"codes":["237110"],"primary":"237110"},"title":"VA GLA WATERLINES REPLACEMENT PROJECT","agency":{"office":{"code":"W912PL","name":"W075 ENDIST LOS ANGELES"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"90017-3409","city":"LOS ANGELES","state":"CA","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-06-13","archive_type":"manual"},"contacts":[{"name":"Raj Cooper","role":"primary","email":"raj.cooper@usace.army.mil","phone":"2134523168"},{"name":"EDWIN RACKLEY","role":"secondary","email":"edwin.r.rackley@usace.army.mil","phone":"2134523309"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"19d340c652504cc69fbecafba6230ef9","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"8a3e9d3d1cc4cff7ab965fb6726e79c23692fcc1a7442281b9a395f2aa39e643","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Existing Conditions: Existing 5 main water lines (6” Domestic Hot Water, 8” Cold Water Pressurized, 8” Cold Water Supply, 12” Fire Water, and 6” Condensate) from Building 501 (Chiller Building) to Building 500 (Hospital) including Building 501 basement, Building 500 basement, and the tunnel from 501 to 500. Because these existing water lines are in bad condition/end of their useful life, they need to be replaced to prevent catastrophic failure/see examples below. Objective: Construct 5 bypass lines, approx. 450’ and divert water to these pipes. Then replace approx. 400’ of the 5 lines. Then remove the bypass lines. Notes: -Current tunnel includes a pipe rack with multiple pipes, and an adjacent walkway. The space is tight. To allow for proper replacement of the 5 pipes, a bypass route has been defined to bypass the lines and allow the hospital to fully function during replacement of pipes. -Contractor to provide all parts, equipment, labor and materials required to make a harmonized removal, for connections of existing wet supply lines and reinstallation of diverse water lines parallel to existing system and consistent with any new piping, fittings, valves, regulators, strainers for regulators, gages, manifold, isolation valves and redundant bypass -Contractor will provide and maintain temporary water service for main hospital during alterations -Contractor must have knowledge of/past performance with methodology of construction procedures/phasing schedules at VA facilities -Not a DB or DBB project -Design being completed at USACE Los Angeles District by USACE Engineers.","origin":"extract"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"W912PL24B0008","place_of_performance":{"zip":"90037","city":{"name":"Los Angeles"},"state":{"code":"CA"},"country":{"code":"USA"}},"product_service_code":"C221"},{"dates":{"posted":"2024-05-31","response_deadline":{"raw":"2024-07-18T13:00:00-07:00","utc":"2024-07-18T20:00:00Z","date":"2024-07-18","time":"13:00:00","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/cb479591a6eb43a0a9d30c172a1c01de/view"},"naics":{"codes":["237110"],"primary":"237110"},"title":"VA GLA WATERLINES REPLACEMENT PROJECT","agency":{"office":{"code":"W912PL","name":"W075 ENDIST LOS ANGELES"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"90017-3409","city":"LOS ANGELES","state":"CA","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-08-02","archive_type":"auto15"},"contacts":[{"name":"Raj Cooper","role":"primary","email":"raj.cooper@usace.army.mil","phone":"2134523168"},{"name":"EDWIN RACKLEY","role":"secondary","email":"edwin.r.rackley@usace.army.mil","phone":"2134523309"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"cb479591a6eb43a0a9d30c172a1c01de","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"70b8529e9f09a776e384aa6caf30108458db4b58fe97d4238f4154cad519a9d6","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Existing Conditions: Existing 5 main water lines (6” Domestic Hot Water, 8” Cold Water Pressurized, 8” Cold Water Supply, 12” Fire Water, and 6” Condensate) from Building 501 (Chiller Building) to Building 500 (Hospital) including Building 501 basement, Building 500 basement, and the tunnel from 501 to 500. Because these existing water lines are in bad condition/end of their useful life, they need to be replaced to prevent catastrophic failure/see examples below. Objective: Construct 5 bypass lines, approx. 450’ and divert water to these pipes. Then replace approx. 400’ of the 5 lines. Then remove the bypass lines. Notes: -Current tunnel includes a pipe rack with multiple pipes, and an adjacent walkway. The space is tight. To allow for proper replacement of the 5 pipes, a bypass route has been defined to bypass the lines and allow the hospital to fully function during replacement of pipes. -Contractor to provide all parts, equipment, labor and materials required to make a harmonized removal, for connections of existing wet supply lines and reinstallation of diverse water lines parallel to existing system and consistent with any new piping, fittings, valves, regulators, strainers for regulators, gages, manifold, isolation valves and redundant bypass -Contractor will provide and maintain temporary water service for main hospital during alterations -Contractor must have knowledge of/past performance with methodology of construction procedures/phasing schedules at VA facilities -Not a DB or DBB project -Design being completed at USACE Los Angeles District by USACE Engineers.","origin":"extract"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"W912PL24B0008","place_of_performance":{"zip":"90037","city":{"name":"Los Angeles"},"state":{"code":"CA"},"country":{"code":"USA"}},"product_service_code":"C221"},{"dates":{"posted":"2024-06-13","response_deadline":{"raw":"2024-07-18T13:00:00-07:00","utc":"2024-07-18T20:00:00Z","date":"2024-07-18","time":"13:00:00","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/0f606826912748fc94125344cebf5853/view"},"naics":{"codes":["237110"],"primary":"237110"},"title":"VA GLA WATERLINES REPLACEMENT PROJECT","agency":{"office":{"code":"W912PL","name":"W075 ENDIST LOS ANGELES"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"90017-3409","city":"LOS ANGELES","state":"CA","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2025-06-13","archive_type":"auto_custom"},"contacts":[{"name":"EDWIN RACKLEY","role":"primary","email":"edwin.r.rackley@usace.army.mil","phone":"2134523309"},{"name":"Raj Cooper","role":"secondary","email":"raj.cooper@usace.army.mil","phone":"2134523168"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"0f606826912748fc94125344cebf5853","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"cb5fbefd28b1033fc38987a8d70d47f729e66c6ca66f221196416870d280208d","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Existing Conditions: Existing 5 main water lines (6? Domestic Hot Water, 8? Cold Water Pressurized, 8? Cold Water Supply, 12? Fire Water, and 6? Condensate) from Building 501 (Chiller Building) to Building 500 (Hospital) including Building 501 basement, Building 500 basement, and the tunnel from 501 to 500. Because these existing water lines are in bad condition/end of their useful life, they need to be replaced to prevent catastrophic failure/see examples below. Objective: Construct 5 bypass lines, approx. 450? and divert water to these pipes. Then replace approx. 400? of the 5 lines. Then remove the bypass lines. Notes:-Current tunnel includes a pipe rack with multiple pipes, and an adjacent walkway. The space is tight. To allow for proper replacement of the 5 pipes, a bypass route has been defined to bypass the lines and allow the hospital to fully function during replacement of pipes.-Contractor to provide all parts, equipment, labor and materials required to make a harmonized removal, for connections of existing wet supply lines and reinstallation of diverse water lines parallel to existing system and consistent with any new piping, fittings, valves, regulators, strainers for regulators, gages, manifold, isolation valves and redundant bypass-Contractor will provide and maintain temporary water service for main hospital during alterations-Contractor must have knowledge of/past performance with methodology of construction procedures/phasing schedules at VA facilities-Not a DB or DBB project-Design being completed at USACE Los Angeles District by USACE Engineers.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"W912PL24B0008","product_service_code":"C221"},{"dates":{"posted":"2024-06-26","response_deadline":{"raw":"2024-07-18T13:00:00-07:00","utc":"2024-07-18T20:00:00Z","date":"2024-07-18","time":"13:00:00","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/20d504813430415c8e660a91e8cb998c/view"},"naics":{"codes":["237110"],"primary":"237110"},"title":"VA GLA WATERLINES REPLACEMENT PROJECT","agency":{"office":{"code":"W912PL","name":"W075 ENDIST LOS ANGELES"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"90017-3409","city":"LOS ANGELES","state":"CA","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2025-06-27","archive_type":"auto_custom"},"contacts":[{"name":"EDWIN RACKLEY","role":"primary","email":"edwin.r.rackley@usace.army.mil","phone":"2134523309"},{"name":"Raj Cooper","role":"secondary","email":"raj.cooper@usace.army.mil","phone":"2134523168"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"20d504813430415c8e660a91e8cb998c","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"4e86f0d07f043a444490aedb736b48120b688feeb7de88bb0f23477d9dd1c9d4","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Existing Conditions: Existing 5 main water lines (6? Domestic Hot Water, 8? Cold Water Pressurized, 8? Cold Water Supply, 12? Fire Water, and 6? Condensate) from Building 501 (Chiller Building) to Building 500 (Hospital) including Building 501 basement, Building 500 basement, and the tunnel from 501 to 500. Because these existing water lines are in bad condition/end of their useful life, they need to be replaced to prevent catastrophic failure/see examples below. Objective: Construct 5 bypass lines, approx. 450? and divert water to these pipes. Then replace approx. 400? of the 5 lines. Then remove the bypass lines. Notes:-Current tunnel includes a pipe rack with multiple pipes, and an adjacent walkway. The space is tight. To allow for proper replacement of the 5 pipes, a bypass route has been defined to bypass the lines and allow the hospital to fully function during replacement of pipes.-Contractor to provide all parts, equipment, labor and materials required to make a harmonized removal, for connections of existing wet supply lines and reinstallation of diverse water lines parallel to existing system and consistent with any new piping, fittings, valves, regulators, strainers for regulators, gages, manifold, isolation valves and redundant bypass-Contractor will provide and maintain temporary water service for main hospital during alterations-Contractor must have knowledge of/past performance with methodology of construction procedures/phasing schedules at VA facilities-Not a DB or DBB project-Design being completed at USACE Los Angeles District by USACE Engineers.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"W912PL24B0008","product_service_code":"C221"},{"dates":{"posted":"2024-07-17","response_deadline":{"raw":"2024-07-23T13:00:00-07:00","utc":"2024-07-23T20:00:00Z","date":"2024-07-23","time":"13:00:00","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/9c23b855d3ff4421aff95e8e4eff0f13/view"},"naics":{"codes":["237110"],"primary":"237110"},"title":"VA GLA WATERLINES REPLACEMENT PROJECT","agency":{"office":{"code":"W912PL","name":"W075 ENDIST LOS ANGELES"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"90017-3409","city":"LOS ANGELES","state":"CA","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2025-07-17","archive_type":"auto_custom"},"contacts":[{"name":"EDWIN RACKLEY","role":"primary","email":"edwin.r.rackley@usace.army.mil","phone":"2134523309"},{"name":"Raj Cooper","role":"secondary","email":"raj.cooper@usace.army.mil","phone":"2134523168"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"9c23b855d3ff4421aff95e8e4eff0f13","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"61cfb873819b82e446de6ae1397934c9aa3aba5b40133effaef95478833a36fa","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Existing Conditions: Existing 5 main water lines (6? Domestic Hot Water, 8? Cold Water Pressurized, 8? Cold Water Supply, 12? Fire Water, and 6? Condensate) from Building 501 (Chiller Building) to Building 500 (Hospital) including Building 501 basement, Building 500 basement, and the tunnel from 501 to 500. Because these existing water lines are in bad condition/end of their useful life, they need to be replaced to prevent catastrophic failure/see examples below. Objective: Construct 5 bypass lines, approx. 450? and divert water to these pipes. Then replace approx. 400? of the 5 lines. Then remove the bypass lines. Notes:-Current tunnel includes a pipe rack with multiple pipes, and an adjacent walkway. The space is tight. To allow for proper replacement of the 5 pipes, a bypass route has been defined to bypass the lines and allow the hospital to fully function during replacement of pipes.-Contractor to provide all parts, equipment, labor and materials required to make a harmonized removal, for connections of existing wet supply lines and reinstallation of diverse water lines parallel to existing system and consistent with any new piping, fittings, valves, regulators, strainers for regulators, gages, manifold, isolation valves and redundant bypass-Contractor will provide and maintain temporary water service for main hospital during alterations-Contractor must have knowledge of/past performance with methodology of construction procedures/phasing schedules at VA facilities-Not a DB or DBB project-Design being completed at USACE Los Angeles District by USACE Engineers.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"W912PL24B0008","product_service_code":"C221"},{"dates":{"posted":"2024-07-22","response_deadline":{"raw":"2024-07-30T13:00:00-07:00","utc":"2024-07-30T20:00:00Z","date":"2024-07-30","time":"13:00:00","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/912567c802a940a9b1788b1d8ad0a943/view"},"naics":{"codes":["237110"],"primary":"237110"},"title":"VA GLA WATERLINES REPLACEMENT PROJECT","agency":{"office":{"code":"W912PL","name":"W075 ENDIST LOS ANGELES"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"90017-3409","city":"LOS ANGELES","state":"CA","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2025-07-22","archive_type":"auto_custom"},"contacts":[{"name":"EDWIN RACKLEY","role":"primary","email":"edwin.r.rackley@usace.army.mil","phone":"2134523309"},{"name":"Raj Cooper","role":"secondary","email":"raj.cooper@usace.army.mil","phone":"2134523168"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"912567c802a940a9b1788b1d8ad0a943","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"46b0af8860fef9a858d7b6a99041fba2dba323caa01d50581a1793ceed6ed639","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Existing Conditions: Existing 5 main water lines (6? Domestic Hot Water, 8? Cold Water Pressurized, 8? Cold Water Supply, 12? Fire Water, and 6? Condensate) from Building 501 (Chiller Building) to Building 500 (Hospital) including Building 501 basement, Building 500 basement, and the tunnel from 501 to 500. Because these existing water lines are in bad condition/end of their useful life, they need to be replaced to prevent catastrophic failure/see examples below. Objective: Construct 5 bypass lines, approx. 450? and divert water to these pipes. Then replace approx. 400? of the 5 lines. Then remove the bypass lines. Notes:-Current tunnel includes a pipe rack with multiple pipes, and an adjacent walkway. The space is tight. To allow for proper replacement of the 5 pipes, a bypass route has been defined to bypass the lines and allow the hospital to fully function during replacement of pipes.-Contractor to provide all parts, equipment, labor and materials required to make a harmonized removal, for connections of existing wet supply lines and reinstallation of diverse water lines parallel to existing system and consistent with any new piping, fittings, valves, regulators, strainers for regulators, gages, manifold, isolation valves and redundant bypass-Contractor will provide and maintain temporary water service for main hospital during alterations-Contractor must have knowledge of/past performance with methodology of construction procedures/phasing schedules at VA facilities-Not a DB or DBB project-Design being completed at USACE Los Angeles District by USACE Engineers.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"W912PL24B0008","product_service_code":"C221"},{"dates":{"posted":"2024-07-22","response_deadline":{"raw":"2024-07-30T13:00:00-07:00","utc":"2024-07-30T20:00:00Z","date":"2024-07-30","time":"13:00:00","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/aac42e9430764609afeab789866f17cf/view"},"naics":{"codes":["237110"],"primary":"237110"},"title":"VA GLA WATERLINES REPLACEMENT PROJECT","agency":{"office":{"code":"W912PL","name":"W075 ENDIST LOS ANGELES"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"90017-3409","city":"LOS ANGELES","state":"CA","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2025-07-23","archive_type":"auto_custom"},"contacts":[{"name":"EDWIN RACKLEY","role":"primary","email":"edwin.r.rackley@usace.army.mil","phone":"2134523309"},{"name":"Raj Cooper","role":"secondary","email":"raj.cooper@usace.army.mil","phone":"2134523168"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"aac42e9430764609afeab789866f17cf","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"88b90259b66bf87c71c68805cb1fde12e3f04e47e1073270260283822c111dd1","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Existing Conditions: Existing 5 main water lines (6? Domestic Hot Water, 8? Cold Water Pressurized, 8? Cold Water Supply, 12? Fire Water, and 6? Condensate) from Building 501 (Chiller Building) to Building 500 (Hospital) including Building 501 basement, Building 500 basement, and the tunnel from 501 to 500. Because these existing water lines are in bad condition/end of their useful life, they need to be replaced to prevent catastrophic failure/see examples below. Objective: Construct 5 bypass lines, approx. 450? and divert water to these pipes. Then replace approx. 400? of the 5 lines. Then remove the bypass lines. Notes:-Current tunnel includes a pipe rack with multiple pipes, and an adjacent walkway. The space is tight. To allow for proper replacement of the 5 pipes, a bypass route has been defined to bypass the lines and allow the hospital to fully function during replacement of pipes.-Contractor to provide all parts, equipment, labor and materials required to make a harmonized removal, for connections of existing wet supply lines and reinstallation of diverse water lines parallel to existing system and consistent with any new piping, fittings, valves, regulators, strainers for regulators, gages, manifold, isolation valves and redundant bypass-Contractor will provide and maintain temporary water service for main hospital during alterations-Contractor must have knowledge of/past performance with methodology of construction procedures/phasing schedules at VA facilities-Not a DB or DBB project-Design being completed at USACE Los Angeles District by USACE Engineers.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"W912PL24B0008","product_service_code":"C221"},{"dates":{"posted":"2024-07-23","response_deadline":{"raw":"2024-07-30T13:00:00-07:00","utc":"2024-07-30T20:00:00Z","date":"2024-07-30","time":"13:00:00","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/59a5ac32bd8e40dc9bf52937da178950/view"},"naics":{"codes":["237110"],"primary":"237110"},"title":"VA GLA WATERLINES REPLACEMENT PROJECT","agency":{"office":{"code":"W912PL","name":"W075 ENDIST LOS ANGELES"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"90017-3409","city":"LOS ANGELES","state":"CA","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2025-07-24","archive_type":"auto_custom"},"contacts":[{"name":"EDWIN RACKLEY","role":"primary","email":"edwin.r.rackley@usace.army.mil","phone":"2134523309"},{"name":"Raj Cooper","role":"secondary","email":"raj.cooper@usace.army.mil","phone":"2134523168"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"59a5ac32bd8e40dc9bf52937da178950","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"037a86850f48834907af30a9f5a8ac5a146d94e15520e7bbefdfdcd8bf3560c0","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Existing Conditions: Existing 5 main water lines (6? Domestic Hot Water, 8? Cold Water Pressurized, 8? Cold Water Supply, 12? Fire Water, and 6? Condensate) from Building 501 (Chiller Building) to Building 500 (Hospital) including Building 501 basement, Building 500 basement, and the tunnel from 501 to 500. Because these existing water lines are in bad condition/end of their useful life, they need to be replaced to prevent catastrophic failure/see examples below. Objective: Construct 5 bypass lines, approx. 450? and divert water to these pipes. Then replace approx. 400? of the 5 lines. Then remove the bypass lines. Notes:-Current tunnel includes a pipe rack with multiple pipes, and an adjacent walkway. The space is tight. To allow for proper replacement of the 5 pipes, a bypass route has been defined to bypass the lines and allow the hospital to fully function during replacement of pipes.-Contractor to provide all parts, equipment, labor and materials required to make a harmonized removal, for connections of existing wet supply lines and reinstallation of diverse water lines parallel to existing system and consistent with any new piping, fittings, valves, regulators, strainers for regulators, gages, manifold, isolation valves and redundant bypass-Contractor will provide and maintain temporary water service for main hospital during alterations-Contractor must have knowledge of/past performance with methodology of construction procedures/phasing schedules at VA facilities-Not a DB or DBB project-Design being completed at USACE Los Angeles District by USACE Engineers.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"W912PL24B0008","product_service_code":"C221"},{"dates":{"posted":"2024-07-29","response_deadline":{"raw":"2024-08-06T13:00:00-07:00","utc":"2024-08-06T20:00:00Z","date":"2024-08-06","time":"13:00:00","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/3b9ca67660a44869966ad132c6571c12/view"},"naics":{"codes":["237110"],"primary":"237110"},"title":"VA GLA WATERLINES REPLACEMENT PROJECT","agency":{"office":{"code":"W912PL","name":"W075 ENDIST LOS ANGELES"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"90017-3409","city":"LOS ANGELES","state":"CA","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2025-07-29","archive_type":"auto_custom"},"contacts":[{"name":"EDWIN RACKLEY","role":"primary","email":"edwin.r.rackley@usace.army.mil","phone":"2134523309"},{"name":"Raj Cooper","role":"secondary","email":"raj.cooper@usace.army.mil","phone":"2134523168"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"3b9ca67660a44869966ad132c6571c12","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"40ce68399cc9efd1ee926afe8e830a9320972c9f9b2f40ac492e3a90c1d5dfc4","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Existing Conditions: Existing 5 main water lines (6? Domestic Hot Water, 8? Cold Water Pressurized, 8? Cold Water Supply, 12? Fire Water, and 6? Condensate) from Building 501 (Chiller Building) to Building 500 (Hospital) including Building 501 basement, Building 500 basement, and the tunnel from 501 to 500. Because these existing water lines are in bad condition/end of their useful life, they need to be replaced to prevent catastrophic failure/see examples below. Objective: Construct 5 bypass lines, approx. 450? and divert water to these pipes. Then replace approx. 400? of the 5 lines. Then remove the bypass lines. Notes:-Current tunnel includes a pipe rack with multiple pipes, and an adjacent walkway. The space is tight. To allow for proper replacement of the 5 pipes, a bypass route has been defined to bypass the lines and allow the hospital to fully function during replacement of pipes.-Contractor to provide all parts, equipment, labor and materials required to make a harmonized removal, for connections of existing wet supply lines and reinstallation of diverse water lines parallel to existing system and consistent with any new piping, fittings, valves, regulators, strainers for regulators, gages, manifold, isolation valves and redundant bypass-Contractor will provide and maintain temporary water service for main hospital during alterations-Contractor must have knowledge of/past performance with methodology of construction procedures/phasing schedules at VA facilities-Not a DB or DBB project-Design being completed at USACE Los Angeles District by USACE Engineers.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"W912PL24B0008","product_service_code":"C221"},{"dates":{"posted":"2024-08-01","response_deadline":{"raw":"2024-08-06T13:00:00-07:00","utc":"2024-08-06T20:00:00Z","date":"2024-08-06","time":"13:00:00","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/90d44ffe77be4d67abce78d26409741b/view"},"naics":{"codes":["237110"],"primary":"237110"},"title":"VA GLA WATERLINES REPLACEMENT PROJECT","agency":{"office":{"code":"W912PL","name":"W075 ENDIST LOS ANGELES"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"90017-3409","city":"LOS ANGELES","state":"CA","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2025-08-01","archive_type":"auto_custom"},"contacts":[{"name":"EDWIN RACKLEY","role":"primary","email":"edwin.r.rackley@usace.army.mil","phone":"2134523309"},{"name":"Raj Cooper","role":"secondary","email":"raj.cooper@usace.army.mil","phone":"2134523168"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"90d44ffe77be4d67abce78d26409741b","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"29fc0ed3605560089a312f72355df1ed648f1be5fe8dd748f01fb477f8c48a28","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Existing Conditions: Existing 5 main water lines (6? Domestic Hot Water, 8? Cold Water Pressurized, 8? Cold Water Supply, 12? Fire Water, and 6? Condensate) from Building 501 (Chiller Building) to Building 500 (Hospital) including Building 501 basement, Building 500 basement, and the tunnel from 501 to 500. Because these existing water lines are in bad condition/end of their useful life, they need to be replaced to prevent catastrophic failure/see examples below. Objective: Construct 5 bypass lines, approx. 450? and divert water to these pipes. Then replace approx. 400? of the 5 lines. Then remove the bypass lines. Notes:-Current tunnel includes a pipe rack with multiple pipes, and an adjacent walkway. The space is tight. To allow for proper replacement of the 5 pipes, a bypass route has been defined to bypass the lines and allow the hospital to fully function during replacement of pipes.-Contractor to provide all parts, equipment, labor and materials required to make a harmonized removal, for connections of existing wet supply lines and reinstallation of diverse water lines parallel to existing system and consistent with any new piping, fittings, valves, regulators, strainers for regulators, gages, manifold, isolation valves and redundant bypass-Contractor will provide and maintain temporary water service for main hospital during alterations-Contractor must have knowledge of/past performance with methodology of construction procedures/phasing schedules at VA facilities-Not a DB or DBB project-Design being completed at USACE Los Angeles District by USACE Engineers.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"W912PL24B0008","product_service_code":"C221"},{"dates":{"posted":"2024-08-06","response_deadline":{"raw":"2024-08-06T13:00:00-07:00","utc":"2024-08-06T20:00:00Z","date":"2024-08-06","time":"13:00:00","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/62b6ddef1a67479c8bde48f0fa16ff26/view"},"naics":{"codes":["237110"],"primary":"237110"},"title":"VA GLA WATERLINES REPLACEMENT PROJECT","agency":{"office":{"code":"W912PL","name":"W075 ENDIST LOS ANGELES"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"90017-3409","city":"LOS ANGELES","state":"CA","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2025-08-01","archive_type":"auto_custom"},"contacts":[{"name":"EDWIN RACKLEY","role":"primary","email":"edwin.r.rackley@usace.army.mil","phone":"2134523309"},{"name":"Raj Cooper","role":"secondary","email":"raj.cooper@usace.army.mil","phone":"2134523168"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"62b6ddef1a67479c8bde48f0fa16ff26","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"ce0336d2d92c5136862c3fc7e5026e68c82766ac01c072934dfb3698e354a241","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Existing Conditions: Existing 5 main water lines (6? Domestic Hot Water, 8? Cold Water Pressurized, 8? Cold Water Supply, 12? Fire Water, and 6? Condensate) from Building 501 (Chiller Building) to Building 500 (Hospital) including Building 501 basement, Building 500 basement, and the tunnel from 501 to 500. Because these existing water lines are in bad condition/end of their useful life, they need to be replaced to prevent catastrophic failure/see examples below. Objective: Construct 5 bypass lines, approx. 450? and divert water to these pipes. Then replace approx. 400? of the 5 lines. Then remove the bypass lines. Notes:-Current tunnel includes a pipe rack with multiple pipes, and an adjacent walkway. The space is tight. To allow for proper replacement of the 5 pipes, a bypass route has been defined to bypass the lines and allow the hospital to fully function during replacement of pipes.-Contractor to provide all parts, equipment, labor and materials required to make a harmonized removal, for connections of existing wet supply lines and reinstallation of diverse water lines parallel to existing system and consistent with any new piping, fittings, valves, regulators, strainers for regulators, gages, manifold, isolation valves and redundant bypass-Contractor will provide and maintain temporary water service for main hospital during alterations-Contractor must have knowledge of/past performance with methodology of construction procedures/phasing schedules at VA facilities-Not a DB or DBB project-Design being completed at USACE Los Angeles District by USACE Engineers.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"W912PL24B0008","product_service_code":"C221"},{"dates":{"posted":"2024-08-22","response_deadline":{"raw":"2024-08-06T13:00:00-07:00","utc":"2024-08-06T20:00:00Z","date":"2024-08-06","time":"13:00:00","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/a6314e4a78534d5d8cb02604ae526304/view"},"naics":{"codes":["237110"],"primary":"237110"},"title":"VA GLA WATERLINES REPLACEMENT PROJECT","agency":{"office":{"code":"W912PL","name":"W075 ENDIST LOS ANGELES"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"90017-3409","city":"LOS ANGELES","state":"CA","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2025-08-01","archive_type":"auto_custom"},"contacts":[{"name":"EDWIN RACKLEY","role":"primary","email":"edwin.r.rackley@usace.army.mil","phone":"2134523309"},{"name":"Raj Cooper","role":"secondary","email":"raj.cooper@usace.army.mil","phone":"2134523168"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"a6314e4a78534d5d8cb02604ae526304","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"6d86abdd3d6ed2d181c7abb066787a7d313f4df43c42272560cef5f04ac9d189","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Existing Conditions: Existing 5 main water lines (6? Domestic Hot Water, 8? Cold Water Pressurized, 8? Cold Water Supply, 12? Fire Water, and 6? Condensate) from Building 501 (Chiller Building) to Building 500 (Hospital) including Building 501 basement, Building 500 basement, and the tunnel from 501 to 500. Because these existing water lines are in bad condition/end of their useful life, they need to be replaced to prevent catastrophic failure/see examples below. Objective: Construct 5 bypass lines, approx. 450? and divert water to these pipes. Then replace approx. 400? of the 5 lines. Then remove the bypass lines. Notes:-Current tunnel includes a pipe rack with multiple pipes, and an adjacent walkway. The space is tight. To allow for proper replacement of the 5 pipes, a bypass route has been defined to bypass the lines and allow the hospital to fully function during replacement of pipes.-Contractor to provide all parts, equipment, labor and materials required to make a harmonized removal, for connections of existing wet supply lines and reinstallation of diverse water lines parallel to existing system and consistent with any new piping, fittings, valves, regulators, strainers for regulators, gages, manifold, isolation valves and redundant bypass-Contractor will provide and maintain temporary water service for main hospital during alterations-Contractor must have knowledge of/past performance with methodology of construction procedures/phasing schedules at VA facilities-Not a DB or DBB project-Design being completed at USACE Los Angeles District by USACE Engineers.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"W912PL24B0008","product_service_code":"C221"}],"due_at":"2024-08-06T20:00:00Z","due_date":"2024-08-06","closes_at":"2024-08-06T20:00:00Z","awardable":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912PL","office_name":"W075 ENDIST LOS ANGELES","state":"CA","county":"06037","county_name":"Los Angeles County","city":"0644000","city_name":"Los Angeles","country":"USA","winner_key":"GK91YND9MT14","amount":null,"linked_awards":12,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z","principal_notice_id":"a6314e4a78534d5d8cb02604ae526304","description":{"text":"Existing Conditions: Existing 5 main water lines (6? Domestic Hot Water, 8? Cold Water Pressurized, 8? Cold Water Supply, 12? Fire Water, and 6? Condensate) from Building 501 (Chiller Building) to Building 500 (Hospital) including Building 501 basement, Building 500 basement, and the tunnel from 501 to 500. Because these existing water lines are in bad condition/end of their useful life, they need to be replaced to prevent catastrophic failure/see examples below. Objective: Construct 5 bypass lines, approx. 450? and divert water to these pipes. Then replace approx. 400? of the 5 lines. Then remove the bypass lines. Notes:-Current tunnel includes a pipe rack with multiple pipes, and an adjacent walkway. The space is tight. To allow for proper replacement of the 5 pipes, a bypass route has been defined to bypass the lines and allow the hospital to fully function during replacement of pipes.-Contractor to provide all parts, equipment, labor and materials required to make a harmonized removal, for connections of existing wet supply lines and reinstallation of diverse water lines parallel to existing system and consistent with any new piping, fittings, valves, regulators, strainers for regulators, gages, manifold, isolation valves and redundant bypass-Contractor will provide and maintain temporary water service for main hospital during alterations-Contractor must have knowledge of/past performance with methodology of construction procedures/phasing schedules at VA facilities-Not a DB or DBB project-Design being completed at USACE Los Angeles District by USACE Engineers.","html":null,"origin":"extract"},"contacts":[{"name":"EDWIN RACKLEY","role":"primary","email":"edwin.r.rackley@usace.army.mil","phone":"2134523309"},{"name":"Raj Cooper","role":"secondary","email":"raj.cooper@usace.army.mil","phone":"2134523168"}],"place_of_performance":null,"office_address":{"zip":"90017-3409","city":"LOS ANGELES","state":"CA","country":"USA"},"naics_codes":["237110"],"award":null,"attachments":[],"awards":[{"award_key":"CONT_AWD_W912PL24C0022_9700_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_W912PL24C0022_9700_-NONE-_-NONE-/","piid":"W912PL24C0022","parent_piid":null,"award_type":"DEFINITIVE CONTRACT","vendor_key":"GK91YND9MT14","recipient_name":"BORJA ENGINEERING & CONSTRUCTION, INC","recipient_uei":"GK91YND9MT14","recipient_cage":"7YY40","recipient_city":"SAN DIEGO","recipient_state":"CA","sub_name":"Department of the Army","office_name":"W075 ENDIST LOS ANGELES","office_key":"o-W912PL","first_action_date":"2024-09-17","last_action_date":"2026-04-20","actions":4,"obligated":"4336590.00","current_total_value":"4336590.00","potential_total_value":"4336590.00","naics":"237110","psc":"C221","extent_competed":"FULL AND OPEN COMPETITION AFTER EXCLUSION OF SOURCES","set_aside":"SMALL BUSINESS SET ASIDE - TOTAL","offers_received":7,"description":"VA WATERLINES PROJECT","method":"solicitation","confidence":"high","evidence":["solicitation number W912PL24B0008 equals the FPDS solicitation identifier","same awarding office W912PL"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"W912PL26S0050","latest_notice_id":"b9d0bb9ba9e44aab82f9b02938734ace","title":"RIO DE FLAG FLOOD CONTROL PROJECT ��������� PHASE 4 LOWER RDF INLET","solicitation_number":"W912PL26S0050","notice_type":"r","first_type":"r","first_posted":"2026-08-27","last_posted":"2026-08-27","notices":2,"due_at":"2026-09-18T21:00:00Z","due_date":"2026-09-18","closes_at":"2026-09-18T21:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912PL","office_name":"W075 ENDIST LOS ANGELES","naics":null,"psc":null,"set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-17T06:28:38.602097Z"},{"key":"W912PL26S0052","latest_notice_id":"245224c2dfbf4e1f86a11460e81158e7","title":"Expand Emergency Power to HVAC Systems","solicitation_number":"W912PL26S0052","notice_type":"r","first_type":"r","first_posted":"2026-09-04","last_posted":"2026-09-04","notices":1,"due_at":"2026-09-21T21:00:00Z","due_date":"2026-09-21","closes_at":"2026-09-21T21:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912PL","office_name":"W075 ENDIST LOS ANGELES","naics":null,"psc":null,"set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"W912PL26S0051","latest_notice_id":"41089e3c49a844089e5d3e6bd60c6bb2","title":"Rio de Flag Flood Risk Management Project","solicitation_number":"W912PL26S0051","notice_type":"r","first_type":"r","first_posted":"2026-09-04","last_posted":"2026-09-09","notices":2,"due_at":"2026-09-21T21:00:00Z","due_date":"2026-09-21","closes_at":"2026-09-21T21:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912PL","office_name":"W075 ENDIST LOS ANGELES","naics":null,"psc":null,"set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"W912PL26RA027","latest_notice_id":"1946b27d85cf40339a04667cadde4e9a","title":"DISASTER RESILIENCY PROGRAM PHASE 3, CREECH AFB, NEVADA","solicitation_number":"W912PL26RA027","notice_type":"o","first_type":"p","first_posted":"2026-07-10","last_posted":"2026-08-25","notices":2,"due_at":"2026-09-24T21:00:00Z","due_date":"2026-09-24","closes_at":"2026-09-24T21:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912PL","office_name":"W075 ENDIST LOS ANGELES","naics":"236220","psc":"Y1BZ","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"W912PL26S0053","latest_notice_id":"3161c7bd334547aebf6eefa3dc25e180","title":"Multiple Award Task Order Contract (MATOC) Healthcare Facility Construction, Repair, and Renovation Services, Arizona","solicitation_number":"W912PL26S0053","notice_type":"r","first_type":"r","first_posted":"2026-09-12","last_posted":"2026-09-12","notices":1,"due_at":"2026-09-28T21:00:00Z","due_date":"2026-09-28","closes_at":"2026-09-28T21:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912PL","office_name":"W075 ENDIST LOS ANGELES","naics":null,"psc":null,"set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"}]}