{"canonical":"https://abierto.us/opportunities/w912es24q0041","key":"W912ES24Q0041","url":"https://abierto.us/opportunities/w912es24q0041","title":"Lifting Skids","solicitation_number":"W912ES24Q0041","notice_type":"a","open":false,"response_deadline":"2024-02-20T23:00:00Z","first_posted":"2024-01-19","last_posted":"2024-03-11","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE ARMY","office":"W07V ENDIST ST PAUL","naics":"332312","psc":"5450","set_aside":"SBA","place_state":"WI","place_county":"55011","place_county_name":"Buffalo County","place_city":"5526850","place_city_name":"Fountain City","winner":"GROWTECH INDUSTRIES LLC","award_amount":"38067.75","publications":[{"notice_id":"302f41a1ac734c13a3a618e36be817a8","title":"Lifting Skids","solicitation_number":"W912ES24Q0041","notice_type":"k","base_type":"k","posted":"2024-01-19","posted_at":null,"due_at":"2024-02-20T23:00:00Z","due_date":"2024-02-20","cancelled":null,"archived":null,"archive_date":"2024-03-06","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/302f41a1ac734c13a3a618e36be817a8/view","enriched":false,"history":[]},{"notice_id":"b0df3bee878840f1a0fe42abfd4d3cb5","title":"Lifting Skids","solicitation_number":"W912ES24Q0041","notice_type":"k","base_type":"k","posted":"2024-01-19","posted_at":null,"due_at":"2024-02-20T23:00:00Z","due_date":"2024-02-20","cancelled":null,"archived":null,"archive_date":"2024-03-06","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/b0df3bee878840f1a0fe42abfd4d3cb5/view","enriched":false,"history":[]},{"notice_id":"dcaeaabfc1c34951a1dcfb2cebc219e5","title":"Lifting Skids","solicitation_number":"W912ES24Q0041","notice_type":"k","base_type":"k","posted":"2024-01-29","posted_at":null,"due_at":"2024-02-20T23:00:00Z","due_date":"2024-02-20","cancelled":null,"archived":null,"archive_date":"2024-03-06","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/dcaeaabfc1c34951a1dcfb2cebc219e5/view","enriched":false,"history":[]},{"notice_id":"f834bfdcd004400291d0d004f96b47e0","title":"Lifting Skids","solicitation_number":"W912ES24Q0041","notice_type":"k","base_type":"k","posted":"2024-01-30","posted_at":null,"due_at":"2024-02-20T23:00:00Z","due_date":"2024-02-20","cancelled":null,"archived":null,"archive_date":"2024-03-06","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/f834bfdcd004400291d0d004f96b47e0/view","enriched":false,"history":[]},{"notice_id":"f48a2eee23d74c729926beec3382f7a8","title":"Lifting Skids","solicitation_number":"W912ES24Q0041","notice_type":"k","base_type":"k","posted":"2024-02-02","posted_at":null,"due_at":"2024-02-20T23:00:00Z","due_date":"2024-02-20","cancelled":null,"archived":null,"archive_date":"2024-03-06","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/f48a2eee23d74c729926beec3382f7a8/view","enriched":false,"history":[]},{"notice_id":"080645a18d0146a8af98e3bbd03f68a3","title":"Lifting Skids","solicitation_number":"W912ES24P0064","notice_type":"a","base_type":"k","posted":"2024-03-11","posted_at":null,"due_at":null,"due_date":null,"cancelled":null,"archived":null,"archive_date":"2024-03-20","award_number":"W912ES24P0064","awardee_name":"GROWTECH INDUSTRIES LLC Buffalo","amount":"38067.75","link_sam":"https://sam.gov/workspace/contract/opp/080645a18d0146a8af98e3bbd03f68a3/view","enriched":false,"history":[]}],"latest_notice_id":"080645a18d0146a8af98e3bbd03f68a3","first_type":"k","notices":[{"dates":{"posted":"2024-01-19","response_deadline":{"raw":"2024-02-20T17:00:00-06:00","utc":"2024-02-20T23:00:00Z","date":"2024-02-20","time":"17:00:00","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/302f41a1ac734c13a3a618e36be817a8/view"},"naics":{"codes":["332312"],"primary":"332312"},"title":"Lifting Skids","agency":{"office":{"code":"W912ES","name":"W07V ENDIST ST PAUL"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"55101-1323","city":"SAINT PAUL","state":"MN","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-03-06","archive_type":"auto15"},"contacts":[{"name":"Karl Just","role":"primary","email":"karl.p.just@usace.army.mil","phone":"6512905768"},{"name":"Jesse Onkka","role":"secondary","email":"Jesse.L.Onkka@usace.army.mil","phone":"6512905444"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"302f41a1ac734c13a3a618e36be817a8","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"8b9ad414fdebb01ca7326408fce249e5a197527fb813d152418a5cfcd3f476e5","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"1. Project Description The Saint Paul District of the U.S. Army Corps of Engineers (USACE) has issued this solicitation for the procurement of three (3) lifting skids for dewatering pumps for the St. Paul District Corps of Engineers – Maintenance & Repair section in Fountain City, WI. 2. Project Scope Statement The current units have deteriorated past a repairable condition. This project is meant to supply all the major components necessary to replace the current units. The Maintenance & Repair section will remove the pumps from the old lifting skids and reinstall the pumps on the new skids. Delivery is to be no later than August 1st, 2024. 3. System Components Specifications for each dewatering pump lifting skid assembly shall be: Flat lifting skid shall be constructed of steel (no stainless or aluminum) and be equipped with fixed rigid steel rigging assembly that holds up the overhead rigging beam. The skid and rigid steel rigging shall not be made of square or pipe steel stock as these material types can hold water and suffer freeze damage during winter operations. The rigid steel rigging shall include an overhead rigging beam (which matches the overall length of the skid) equipped with two stainless steel load rated swivel hoisting points located 24” in from each end of the overhead rigging beam. The overhead rigging beam shall have ¾” holes drilled every 6 inches on center along its length to enable top mounting bracket installations of various pump assembly configurations. All steel components of the lifting skid and rigging assembly shall be entirely galvanized with topcoat paint finish in the color safety yellow to allow maximum visibility to the divers during underwater operations. The flat lifting skid base design shall include a uniform bolt hole pattern grid of 3/4” bolt holes, 12” on center, across the entire area of the base to allow for securing various pump configurations. The flat lifting skid design shall include fork pockets in the base for moving the skid with a fork truck. The steel lifting skid and rigging assembly shall be no larger than 96” long by 54” wide and no smaller than 95” long by 53” wide; and the platform shall not have side walls to allow water and debris to flow off it when being pulled from the water (see attached drawing). The rigid steel overhead rigging beam shall be orientated the long way over the skid base no higher than 72” and no lower than 71” high (see attached drawing). The flat lifting skid, rigid steel rigging assembly, and the picking points shall all be load rated for no less than 10,000 lbs. and load tested to 125% of load to include certification documentation with delivery. All lifting skid and rigging assembly components must meet ASME B30.20 standards for below-the-hook lifting devices as well as BTH-1 Design for Below the Hook Standard and must also be designed and stamped by a Professional Engineer (PE). Manufacturing drawings and documentation of load ratings shall be provided for each separate lifting skid and rigging assembly. The lifting skid and rigging assembly shall be labeled with the empty skid weight, load capacity, manufacturer model number, and manufacturer serial number. Delivery Address: US Army Corps of Engineers Fountain City Service 431 North Shore Drive Fountain City, WI 54629 Hours of Operation: 0700-1500 Monday thru Friday Closed weekends and Federal Holidays","origin":"extract"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"W912ES24Q0041","place_of_performance":{"zip":"54629","city":{"name":"Fountain City"},"state":{"code":"WI"},"country":{"code":"USA"}},"product_service_code":"5450"},{"dates":{"posted":"2024-01-19","response_deadline":{"raw":"2024-02-20T17:00:00-06:00","utc":"2024-02-20T23:00:00Z","date":"2024-02-20","time":"17:00:00","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/b0df3bee878840f1a0fe42abfd4d3cb5/view"},"naics":{"codes":["332312"],"primary":"332312"},"title":"Lifting Skids","agency":{"office":{"code":"W912ES","name":"W07V ENDIST ST PAUL"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"55101-1323","city":"SAINT PAUL","state":"MN","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-03-06","archive_type":"auto15"},"contacts":[{"name":"Karl Just","role":"primary","email":"karl.p.just@usace.army.mil","phone":"6512905768"},{"name":"Jesse Onkka","role":"secondary","email":"Jesse.L.Onkka@usace.army.mil","phone":"6512905444"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"b0df3bee878840f1a0fe42abfd4d3cb5","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"2d0e29edc2e008ce6b0213fb3eaf64042156be08fd05c7c5f5cf285ef53e612f","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"1. Project Description The Saint Paul District of the U.S. Army Corps of Engineers (USACE) has issued this solicitation for the procurement of three (3) lifting skids for dewatering pumps for the St. Paul District Corps of Engineers – Maintenance & Repair section in Fountain City, WI. 2. Project Scope Statement The current units have deteriorated past a repairable condition. This project is meant to supply all the major components necessary to replace the current units. The Maintenance & Repair section will remove the pumps from the old lifting skids and reinstall the pumps on the new skids. Delivery is to be no later than August 1st, 2024. 3. System Components Specifications for each dewatering pump lifting skid assembly shall be: Flat lifting skid shall be constructed of steel (no stainless or aluminum) and be equipped with fixed rigid steel rigging assembly that holds up the overhead rigging beam. The skid and rigid steel rigging shall not be made of square or pipe steel stock as these material types can hold water and suffer freeze damage during winter operations. The rigid steel rigging shall include an overhead rigging beam (which matches the overall length of the skid) equipped with two stainless steel load rated swivel hoisting points located 24” in from each end of the overhead rigging beam. The overhead rigging beam shall have ¾” holes drilled every 6 inches on center along its length to enable top mounting bracket installations of various pump assembly configurations. All steel components of the lifting skid and rigging assembly shall be entirely galvanized with topcoat paint finish in the color safety yellow to allow maximum visibility to the divers during underwater operations. The flat lifting skid base design shall include a uniform bolt hole pattern grid of 3/4” bolt holes, 12” on center, across the entire area of the base to allow for securing various pump configurations. The flat lifting skid design shall include fork pockets in the base for moving the skid with a fork truck. The steel lifting skid and rigging assembly shall be no larger than 96” long by 54” wide and no smaller than 95” long by 53” wide; and the platform shall not have side walls to allow water and debris to flow off it when being pulled from the water (see attached drawing). The rigid steel overhead rigging beam shall be orientated the long way over the skid base no higher than 72” and no lower than 71” high (see attached drawing). The flat lifting skid, rigid steel rigging assembly, and the picking points shall all be load rated for no less than 10,000 lbs. and load tested to 125% of load to include certification documentation with delivery. All lifting skid and rigging assembly components must meet ASME B30.20 standards for below-the-hook lifting devices as well as BTH-1 Design for Below the Hook Standard and must also be designed and stamped by a Professional Engineer (PE). Manufacturing drawings and documentation of load ratings shall be provided for each separate lifting skid and rigging assembly. The lifting skid and rigging assembly shall be labeled with the empty skid weight, load capacity, manufacturer model number, and manufacturer serial number. Delivery Address: US Army Corps of Engineers Fountain City Service 431 North Shore Drive Fountain City, WI 54629 Hours of Operation: 0700-1500 Monday thru Friday Closed weekends and Federal Holidays","origin":"extract"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"W912ES24Q0041","place_of_performance":{"zip":"54629","city":{"name":"Fountain City"},"state":{"code":"WI"},"country":{"code":"USA"}},"product_service_code":"5450"},{"dates":{"posted":"2024-01-29","response_deadline":{"raw":"2024-02-20T17:00:00-06:00","utc":"2024-02-20T23:00:00Z","date":"2024-02-20","time":"17:00:00","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/dcaeaabfc1c34951a1dcfb2cebc219e5/view"},"naics":{"codes":["332312"],"primary":"332312"},"title":"Lifting Skids","agency":{"office":{"code":"W912ES","name":"W07V ENDIST ST PAUL"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"55101-1323","city":"SAINT PAUL","state":"MN","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-03-06","archive_type":"auto15"},"contacts":[{"name":"Karl Just","role":"primary","email":"karl.p.just@usace.army.mil","phone":"6512905768"},{"name":"Jesse Onkka","role":"secondary","email":"Jesse.L.Onkka@usace.army.mil","phone":"6512905444"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"dcaeaabfc1c34951a1dcfb2cebc219e5","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"9a6a25ea382b1b5780c0be52b5839ef91b5c296dc7e39dbaa746e3c750d46908","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Scope of Work – Dewatering Pump Flat Lifting Skids (3) 1. Project Description The Saint Paul District of the U.S. Army Corps of Engineers (USACE) has issued this solicitation for the procurement of three (3) lifting skids for dewatering pumps for the St. Paul District Corps of Engineers – Maintenance & Repair section in Fountain City, WI. 2. Project Scope Statement The current units have deteriorated past a repairable condition. This project is meant to supply all the major components necessary to replace the current units. The Maintenance & Repair section will remove the pumps from the old lifting skids and reinstall the pumps on the new skids. Delivery is to be no later than August 1st, 2024. 3. System Components Specifications for each dewatering pump lifting skid assembly shall be: Flat lifting skid shall be constructed of steel (no stainless or aluminum) and be equipped with fixed rigid steel rigging assembly that holds up the overhead rigging beam. The skid and rigid steel rigging may be made of square or pipe steel stock, however, these material types can hold water and suffer freeze damage during winter operations. All ends must be fully open to prevent the water from being trapped and ensure galvanizing reaches those surfaces. The rigid steel rigging shall include an overhead rigging beam (which matches the overall length of the skid) equipped with two stainless steel load rated swivel hoisting points located 24” in from each end of the overhead rigging beam. Stainless steel shackles may be used provided they utilize either a hole in the beam for the shackle pin OR a fixed lifting eye assembly that bolts onto the rigging beam. The overhead rigging beam shall have ¾” holes drilled every 6 inches on center along its length to enable top mounting bracket installations of various pump assembly configurations. All steel components of the lifting skid and rigging assembly shall be entirely galvanized. The flat lifting skid base design shall include a uniform bolt hole pattern grid of 3/4” bolt holes, 12” on center, across the entire area of the base to allow for securing various pump configurations. The flat lifting skid design shall include fork pockets in the base for moving the skid with a fork truck. The steel lifting skid and rigging assembly shall be no larger than 96” long by 54” wide and no smaller than 93” long by 51” wide to allow for rigid brackets and hardware; and the platform shall not have side walls to allow water and debris to flow off it when being pulled from the water (see attached drawing). 84” maximum overall height from ground to top of rigging beam. The rigid steel overhead rigging beam shall be orientated the long way over the skid base no higher than 72” and no lower than 71” high from skid floor to bottom of rigging beam (see attached drawing). The flat lifting skid, rigid steel rigging assembly, and the picking points shall all be load rated for no less than 10,000 lbs. and load tested to 125% of load to include certification documentation with delivery. All lifting skid and rigging assembly components must meet ASME B30.20 standards for below-the-hook lifting devices as well as BTH-1 Design for Below the Hook Standard and must also be designed and stamped by a Professional Engineer (PE). Manufacturing drawings and documentation of load ratings shall be provided for each separate lifting skid and rigging assembly. The lifting skid and rigging assembly shall be labeled with the empty skid weight, load capacity, manufacturer model number, and manufacturer serial number. Delivery Address: US Army Corps of Engineers Fountain City Service 431 North Shore Drive Fountain City, WI 54629","origin":"extract"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"W912ES24Q0041","place_of_performance":{"zip":"54629","city":{"name":"Fountain City"},"state":{"code":"WI"},"country":{"code":"USA"}},"product_service_code":"5450"},{"dates":{"posted":"2024-01-30","response_deadline":{"raw":"2024-02-20T17:00:00-06:00","utc":"2024-02-20T23:00:00Z","date":"2024-02-20","time":"17:00:00","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/f834bfdcd004400291d0d004f96b47e0/view"},"naics":{"codes":["332312"],"primary":"332312"},"title":"Lifting Skids","agency":{"office":{"code":"W912ES","name":"W07V ENDIST ST PAUL"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"55101-1323","city":"SAINT PAUL","state":"MN","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-03-06","archive_type":"auto15"},"contacts":[{"name":"Karl Just","role":"primary","email":"karl.p.just@usace.army.mil","phone":"6512905768"},{"name":"Jesse Onkka","role":"secondary","email":"Jesse.L.Onkka@usace.army.mil","phone":"6512905444"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"f834bfdcd004400291d0d004f96b47e0","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"5aefd0fa927cc9382e2a6fba5b8da045e07c6bbc3d40a4943bec3e7e3dde3781","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Scope of Work – Dewatering Pump Flat Lifting Skids (3) 1. Project Description The Saint Paul District of the U.S. Army Corps of Engineers (USACE) has issued this solicitation for the procurement of three (3) lifting skids for dewatering pumps for the St. Paul District Corps of Engineers – Maintenance & Repair section in Fountain City, WI. 2. Project Scope Statement The current units have deteriorated past a repairable condition. This project is meant to supply all the major components necessary to replace the current units. The Maintenance & Repair section will remove the pumps from the old lifting skids and reinstall the pumps on the new skids. Delivery is to be no later than August 1st, 2024. 3. System Components Specifications for each dewatering pump lifting skid assembly shall be: Flat lifting skid shall be constructed of steel (no stainless or aluminum) and be equipped with fixed rigid steel rigging assembly that holds up the overhead rigging beam. The skid and rigid steel rigging may be made of square or pipe steel stock, however, these material types can hold water and suffer freeze damage during winter operations. All ends must be fully open to prevent the water from being trapped and ensure galvanizing reaches those surfaces. The rigid steel rigging shall include an overhead rigging beam (which matches the overall length of the skid) equipped with two stainless steel load rated swivel hoisting points located 24” in from each end of the overhead rigging beam. Stainless steel shackles may be used provided they utilize either a hole in the beam for the shackle pin OR a fixed lifting eye assembly that bolts onto the rigging beam. The overhead rigging beam shall have ¾” holes drilled every 6 inches on center along its length to enable top mounting bracket installations of various pump assembly configurations. All steel components of the lifting skid and rigging assembly shall be entirely galvanized. The flat lifting skid base design shall include a uniform bolt hole pattern grid of 3/4” bolt holes, 12” on center, across the entire area of the base to allow for securing various pump configurations. The flat lifting skid design shall include fork pockets in the base for moving the skid with a fork truck. The steel lifting skid and rigging assembly shall be no larger than 96” long by 54” wide and no smaller than 93” long by 51” wide to allow for rigid brackets and hardware; and the platform shall not have side walls to allow water and debris to flow off it when being pulled from the water (see attached drawing). 84” maximum overall height from ground to top of rigging beam. The rigid steel overhead rigging beam shall be orientated the long way over the skid base no higher than 72” and no lower than 71” high from skid floor to bottom of rigging beam (see attached drawing). The flat lifting skid, rigid steel rigging assembly, and the picking points shall all be load rated for no less than 10,000 lbs. and load tested to 125% of load to include certification documentation with delivery. All lifting skid and rigging assembly components must meet ASME B30.20 standards for below-the-hook lifting devices as well as BTH-1 Design for Below the Hook Standard and must also be designed and stamped by a Professional Engineer (PE). Manufacturing drawings and documentation of load ratings shall be provided for each separate lifting skid and rigging assembly. The lifting skid and rigging assembly shall be labeled with the empty skid weight, load capacity, manufacturer model number, and manufacturer serial number. Delivery Address: US Army Corps of Engineers Fountain City Service 431 North Shore Drive Fountain City, WI 54629","origin":"extract"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"W912ES24Q0041","place_of_performance":{"zip":"54629","city":{"name":"Fountain City"},"state":{"code":"WI"},"country":{"code":"USA"}},"product_service_code":"5450"},{"dates":{"posted":"2024-02-02","response_deadline":{"raw":"2024-02-20T17:00:00-06:00","utc":"2024-02-20T23:00:00Z","date":"2024-02-20","time":"17:00:00","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/f48a2eee23d74c729926beec3382f7a8/view"},"naics":{"codes":["332312"],"primary":"332312"},"title":"Lifting Skids","agency":{"office":{"code":"W912ES","name":"W07V ENDIST ST PAUL"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"55101-1323","city":"SAINT PAUL","state":"MN","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-03-06","archive_type":"auto15"},"contacts":[{"name":"Karl Just","role":"primary","email":"karl.p.just@usace.army.mil","phone":"6512905768"},{"name":"Jesse Onkka","role":"secondary","email":"Jesse.L.Onkka@usace.army.mil","phone":"6512905444"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"f48a2eee23d74c729926beec3382f7a8","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"18985a4c9f5c24bc1388c5c0355abcf978f06a3914f71169c05f1fc29ebdb0a8","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Scope of Work – Dewatering Pump Flat Lifting Skids (3) 1. Project Description The Saint Paul District of the U.S. Army Corps of Engineers (USACE) has issued this solicitation for the procurement of three (3) lifting skids for dewatering pumps for the St. Paul District Corps of Engineers – Maintenance & Repair section in Fountain City, WI. 2. Project Scope Statement The current units have deteriorated past a repairable condition. This project is meant to supply all the major components necessary to replace the current units. The Maintenance & Repair section will remove the pumps from the old lifting skids and reinstall the pumps on the new skids. Delivery is to be no later than August 1st, 2024. 3. System Components Specifications for each dewatering pump lifting skid assembly shall be: Flat lifting skid shall be constructed of steel (no stainless or aluminum) and be equipped with fixed rigid steel rigging assembly that holds up the overhead rigging beam. The skid and rigid steel rigging may be made of square or pipe steel stock, however, these material types can hold water and suffer freeze damage during winter operations. All ends must be fully open to prevent the water from being trapped and ensure galvanizing reaches those surfaces. The rigid steel rigging shall include an overhead rigging beam (which matches the overall length of the skid) equipped with two stainless steel load rated swivel hoisting points located 24” in from each end of the overhead rigging beam. Stainless steel shackles may be used provided they utilize either a hole in the beam for the shackle pin OR a fixed lifting eye assembly that bolts onto the rigging beam. The overhead rigging beam shall have ¾” holes drilled every 6 inches on center along its length to enable top mounting bracket installations of various pump assembly configurations. All steel components of the lifting skid and rigging assembly shall be entirely galvanized. The flat lifting skid base design shall include a uniform bolt hole pattern grid of 3/4” bolt holes, 12” on center, across the entire area of the base to allow for securing various pump configurations. The flat lifting skid design shall include fork pockets in the base for moving the skid with a fork truck. The steel lifting skid and rigging assembly shall be no larger than 96” long by 54” wide and no smaller than 93” long by 51” wide to allow for rigid brackets and hardware; and the platform shall not have side walls to allow water and debris to flow off it when being pulled from the water (see attached drawing). 84” maximum overall height from ground to top of rigging beam. If utilizing fixed lifting eyes, maximum height of 88” from ground to top of eye. The rigid steel overhead rigging beam shall be orientated the long way over the skid base no higher than 72” and no lower than 71” high from skid floor to bottom of rigging beam (see attached drawing). The flat lifting skid, rigid steel rigging assembly, and the picking points shall all be load rated for no less than 10,000 lbs. and load tested to 125% of load to include certification documentation with delivery. All lifting skid and rigging assembly components must meet ASME B30.20 standards for below-the-hook lifting devices as well as BTH-1 Design for Below the Hook Standard and must also be designed and stamped by a Professional Engineer (PE). Manufacturing drawings and documentation of load ratings shall be provided for each separate lifting skid and rigging assembly. The lifting skid and rigging assembly shall be labeled with the empty skid weight, load capacity, manufacturer model number, and manufacturer serial number. Delivery Address: US Army Corps of Engineers Fountain City Service 431 North Shore Drive Fountain City, WI 54629","origin":"extract"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"W912ES24Q0041","place_of_performance":{"zip":"54629","city":{"name":"Fountain City"},"state":{"code":"WI"},"country":{"code":"USA"}},"product_service_code":"5450"},{"award":{"date":"2024-03-05","amount":"38067.75","number":"W912ES24P0064","awardee":{"raw":"GROWTECH INDUSTRIES LLC Buffalo NY 14219 USA","name":"GROWTECH INDUSTRIES LLC Buffalo","location":{"zip":"14219","state":{"code":"NY"},"country":{"code":"USA"}}}},"dates":{"posted":"2024-03-11","award_date":"2024-03-05"},"links":{"sam":"https://sam.gov/workspace/contract/opp/080645a18d0146a8af98e3bbd03f68a3/view"},"naics":{"codes":["332312"],"primary":"332312"},"title":"Lifting Skids","agency":{"office":{"code":"W912ES","name":"W07V ENDIST ST PAUL"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"55101-1323","city":"SAINT PAUL","state":"MN","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-03-20","archive_type":"auto15"},"contacts":[{"name":"Karl Just","role":"primary","email":"karl.p.just@usace.army.mil","phone":"6512905768"},{"name":"Jesse Onkka","role":"secondary","email":"Jesse.L.Onkka@usace.army.mil","phone":"6512905444"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"080645a18d0146a8af98e3bbd03f68a3","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"cffdfe4c342d4e1193977a6e71ed62d86efd8292ae46b676a01fda6835bec0f3","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"notice_type":{"code":"a","label":"Award Notice"},"schema_version":1,"solicitation_number":"W912ES24P0064","place_of_performance":{"zip":"54629","city":{"name":"Fountain City"},"state":{"code":"WI"},"country":{"code":"USA"}},"product_service_code":"5450"}],"due_at":"2024-02-20T23:00:00Z","due_date":"2024-02-20","closes_at":"2024-02-20T23:00:00Z","awardable":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912ES","office_name":"W07V ENDIST ST PAUL","state":"WI","county":"55011","county_name":"Buffalo County","city":"5526850","city_name":"Fountain City","country":"USA","winner_key":"LK79DB5JL665","amount":"38067.75","linked_awards":6,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z","principal_notice_id":"f48a2eee23d74c729926beec3382f7a8","description":{"text":"Scope of Work – Dewatering Pump Flat Lifting Skids (3) 1. Project Description The Saint Paul District of the U.S. Army Corps of Engineers (USACE) has issued this solicitation for the procurement of three (3) lifting skids for dewatering pumps for the St. Paul District Corps of Engineers – Maintenance & Repair section in Fountain City, WI. 2. Project Scope Statement The current units have deteriorated past a repairable condition. This project is meant to supply all the major components necessary to replace the current units. The Maintenance & Repair section will remove the pumps from the old lifting skids and reinstall the pumps on the new skids. Delivery is to be no later than August 1st, 2024. 3. System Components Specifications for each dewatering pump lifting skid assembly shall be: Flat lifting skid shall be constructed of steel (no stainless or aluminum) and be equipped with fixed rigid steel rigging assembly that holds up the overhead rigging beam. The skid and rigid steel rigging may be made of square or pipe steel stock, however, these material types can hold water and suffer freeze damage during winter operations. All ends must be fully open to prevent the water from being trapped and ensure galvanizing reaches those surfaces. The rigid steel rigging shall include an overhead rigging beam (which matches the overall length of the skid) equipped with two stainless steel load rated swivel hoisting points located 24” in from each end of the overhead rigging beam. Stainless steel shackles may be used provided they utilize either a hole in the beam for the shackle pin OR a fixed lifting eye assembly that bolts onto the rigging beam. The overhead rigging beam shall have ¾” holes drilled every 6 inches on center along its length to enable top mounting bracket installations of various pump assembly configurations. All steel components of the lifting skid and rigging assembly shall be entirely galvanized. The flat lifting skid base design shall include a uniform bolt hole pattern grid of 3/4” bolt holes, 12” on center, across the entire area of the base to allow for securing various pump configurations. The flat lifting skid design shall include fork pockets in the base for moving the skid with a fork truck. The steel lifting skid and rigging assembly shall be no larger than 96” long by 54” wide and no smaller than 93” long by 51” wide to allow for rigid brackets and hardware; and the platform shall not have side walls to allow water and debris to flow off it when being pulled from the water (see attached drawing). 84” maximum overall height from ground to top of rigging beam. If utilizing fixed lifting eyes, maximum height of 88” from ground to top of eye. The rigid steel overhead rigging beam shall be orientated the long way over the skid base no higher than 72” and no lower than 71” high from skid floor to bottom of rigging beam (see attached drawing). The flat lifting skid, rigid steel rigging assembly, and the picking points shall all be load rated for no less than 10,000 lbs. and load tested to 125% of load to include certification documentation with delivery. All lifting skid and rigging assembly components must meet ASME B30.20 standards for below-the-hook lifting devices as well as BTH-1 Design for Below the Hook Standard and must also be designed and stamped by a Professional Engineer (PE). Manufacturing drawings and documentation of load ratings shall be provided for each separate lifting skid and rigging assembly. The lifting skid and rigging assembly shall be labeled with the empty skid weight, load capacity, manufacturer model number, and manufacturer serial number. Delivery Address: US Army Corps of Engineers Fountain City Service 431 North Shore Drive Fountain City, WI 54629","html":null,"origin":"extract"},"contacts":[{"name":"Karl Just","role":"primary","email":"karl.p.just@usace.army.mil","phone":"6512905768"},{"name":"Jesse Onkka","role":"secondary","email":"Jesse.L.Onkka@usace.army.mil","phone":"6512905444"}],"place_of_performance":{"zip":"54629","city":{"name":"Fountain City"},"state":{"code":"WI"},"country":{"code":"USA"}},"office_address":{"zip":"55101-1323","city":"SAINT PAUL","state":"MN","country":"USA"},"naics_codes":["332312"],"award":null,"attachments":[],"awards":[{"award_key":"CONT_AWD_W912ES24P0064_9700_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_W912ES24P0064_9700_-NONE-_-NONE-/","piid":"W912ES24P0064","parent_piid":null,"award_type":"PURCHASE ORDER","vendor_key":"LK79DB5JL665","recipient_name":"GROWTECH INDUSTRIES LLC","recipient_uei":"LK79DB5JL665","recipient_cage":"81NH6","recipient_city":"BUFFALO","recipient_state":"NY","sub_name":"Department of the Army","office_name":"W07V ENDIST ST PAUL","office_key":"o-W912ES","first_action_date":"2024-03-05","last_action_date":"2024-03-05","actions":1,"obligated":"38067.75","current_total_value":"38067.75","potential_total_value":"38067.75","naics":"332312","psc":"5450","extent_competed":"COMPETED UNDER SAP","set_aside":"SMALL BUSINESS SET ASIDE - TOTAL","offers_received":10,"description":"PUMP SKID/PLATFORM","method":"piid","confidence":"high","evidence":["award number W912ES24P0064 equals the contract number","same awarding office W912ES"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"W912ES26QA097","latest_notice_id":"b7af646b80ff421282b403933e63a31f","title":"Collect and Plant Willow Cuttings in Mississippi River Pools 3, 5, and 5A","solicitation_number":"W912ES26QA097","notice_type":"o","first_type":"p","first_posted":"2026-08-13","last_posted":"2026-09-14","notices":4,"due_at":"2026-09-21T16:00:00Z","due_date":"2026-09-21","closes_at":"2026-09-21T16:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912ES","office_name":"W07V ENDIST ST PAUL","naics":"561730","psc":"F018","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"W912ES26QA111","latest_notice_id":"cc1ca3e1f3394c9581fae50a3aabb7da","title":"Blackhawk Park Pre-Fabricated Comfort Station","solicitation_number":"W912ES26QA111","notice_type":"o","first_type":"o","first_posted":"2026-09-08","last_posted":"2026-09-15","notices":2,"due_at":"2026-09-22T21:30:00Z","due_date":"2026-09-22","closes_at":"2026-09-22T21:30:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912ES","office_name":"W07V ENDIST ST PAUL","naics":"238120","psc":"Y1JZ","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"W912ES26QA102","latest_notice_id":"9aabbe1f062a4922b3d9cdc081cf41e1","title":"LD3 Tree Removal","solicitation_number":"W912ES26QA102","notice_type":"o","first_type":"o","first_posted":"2026-09-11","last_posted":"2026-09-16","notices":5,"due_at":"2026-09-23T21:30:00Z","due_date":"2026-09-23","closes_at":"2026-09-23T21:30:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912ES","office_name":"W07V ENDIST ST PAUL","naics":"561730","psc":"F014","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-17T06:28:38.602097Z"},{"key":"W912ES26QA113","latest_notice_id":"0ff2dde5059f43a8b25914f2cb4fefde","title":"Oil Purifier","solicitation_number":"W912ES26QA113","notice_type":"o","first_type":"o","first_posted":"2026-09-16","last_posted":"2026-09-16","notices":1,"due_at":"2026-09-23T22:30:00Z","due_date":"2026-09-23","closes_at":"2026-09-23T22:30:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912ES","office_name":"W07V ENDIST ST PAUL","naics":"333998","psc":"4330","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-17T06:28:38.602097Z"},{"key":"W912ES26QA112","latest_notice_id":"082a9c2c52b341f5acea6587c4a58309","title":"Crane LMI System, Barge Integration and Components Installation","solicitation_number":"W912ES26QA112","notice_type":"o","first_type":"o","first_posted":"2026-09-10","last_posted":"2026-09-10","notices":1,"due_at":"2026-09-25T12:00:00Z","due_date":"2026-09-25","closes_at":"2026-09-25T12:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912ES","office_name":"W07V ENDIST ST PAUL","naics":"333120","psc":"5999","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"}]}