{"canonical":"https://abierto.us/opportunities/w912ch25qa017","key":"W912CH25QA017","url":"https://abierto.us/opportunities/w912ch25qa017","title":"FLUID CHILLER","solicitation_number":"W912CH25QA017","notice_type":"k","open":false,"response_deadline":"2025-06-24T19:00:00Z","first_posted":"2025-06-09","last_posted":"2025-06-17","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE ARMY","office":"W6QK ACC- DTA","naics":"333413","psc":"4140","set_aside":"SBA","place_state":"MI","place_county":"26099","place_county_name":"Macomb County","place_city":"2684000","place_city_name":"Warren","winner":"KIJERO, LLC","award_amount":null,"publications":[{"notice_id":"b667b6df587e4050ab8b1ef9b10de54b","title":"FLUID CHILLER","solicitation_number":"W912CH25QA017","notice_type":"k","base_type":"k","posted":"2025-06-09","posted_at":null,"due_at":"2025-07-17T19:00:00Z","due_date":"2025-07-17","cancelled":null,"archived":null,"archive_date":"2026-06-09","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/b667b6df587e4050ab8b1ef9b10de54b/view","enriched":false,"history":[]},{"notice_id":"1f4722092b21443bac717b987e0f0d09","title":"FLUID CHILLER","solicitation_number":"W912CH25QA017","notice_type":"k","base_type":"k","posted":"2025-06-17","posted_at":null,"due_at":"2025-06-24T19:00:00Z","due_date":"2025-06-24","cancelled":null,"archived":null,"archive_date":"2026-06-17","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/1f4722092b21443bac717b987e0f0d09/view","enriched":false,"history":[]}],"latest_notice_id":"1f4722092b21443bac717b987e0f0d09","first_type":"k","notices":[{"dates":{"posted":"2025-06-09","response_deadline":{"raw":"2025-07-17T15:00:00-04:00","utc":"2025-07-17T19:00:00Z","date":"2025-07-17","time":"15:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/b667b6df587e4050ab8b1ef9b10de54b/view"},"naics":{"codes":["333413"],"primary":"333413"},"title":"FLUID CHILLER","agency":{"office":{"code":"W912CH","name":"W6QK ACC- DTA"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"48397-5000","city":"WARREN","state":"MI","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2026-06-09","archive_type":"auto_custom"},"contacts":[{"name":"JUDY-ANN LAWRENCE","role":"primary","email":"judy-ann.v.lawrence.civ@army.mil","phone":"5206726507"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"b667b6df587e4050ab8b1ef9b10de54b","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"07b204bd8d55c0d4f5e6c2466a1d06ab2c95b3e5565a0ecfdbf566d103868165","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-09-16T17:45:50.850439Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"text":"FLUID CHILLER:61,000 BTU?s / HrInlet /Outlet Piping needs to be 11/4? NPTPump Specifications must be 18 GMP at 38 PSIVoltage / Phase must be 230/1, 230/3, 460/3Rated load amps at 11A@460/3Dimensions must be 42?L X 28?W X 66?HDry Weight must be approximately 760 lbs.Chiller outlet temp should be 50 degrees FahrenheitMust have at least a 26-gallon reservoirChiller pump must be rated for no less than 5gpmPump must be continuous duty and of stainless-steel constructionAll piping must be non-ferrousShall have a footprint no larger than 42? x 28? and less than 80? in heightShall have a digital display for temperature display and controlShall use R407c refrigerantShall have a highly efficient scroll compressorShall include at least a 1-year parts and labor warrantyMust be rated to operate outside all year","origin":"extract"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"W912CH25QA017","place_of_performance":{"street":"W4GH CCDC GROUND VEHICLE SYS.6501 E 11 MILE ROAD SHIPPING AND RECEIVING BLDG 249WARREN, MI 48397-5000"},"product_service_code":"4140"},{"dates":{"posted":"2025-06-17","response_deadline":{"raw":"2025-06-24T15:00:00-04:00","utc":"2025-06-24T19:00:00Z","date":"2025-06-24","time":"15:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/1f4722092b21443bac717b987e0f0d09/view"},"naics":{"codes":["333413"],"primary":"333413"},"title":"FLUID CHILLER","agency":{"office":{"code":"W912CH","name":"W6QK ACC- DTA"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"48397-5000","city":"WARREN","state":"MI","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2026-06-17","archive_type":"auto_custom"},"contacts":[{"name":"JUDY-ANN LAWRENCE","role":"primary","email":"judy-ann.v.lawrence.civ@army.mil","phone":"5206726507"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"1f4722092b21443bac717b987e0f0d09","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"e4e16becaa5387e3f64d626b23f0f295b53caff7814a93fb54cd9d10d836c9e8","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-09-16T17:45:50.850439Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"text":"FLUID CHILLER:61,000 BTU?s / Hr Inlet /Outlet Piping needs to be 11/4? NPT. Pump Specifications must be 18 GMP at 38 PSI. Voltage / Phase must be 230/1, 230/3, 460/3Rated load amps at 11A@460/3. Dimensions must be 42?L X 28?W X 66?H. Dry Weight must be approximately 760 lbs. Chiller outlet temp should be 50 degrees Fahrenheit. Must have at least a 26-gallon reservoir. Chiller pump must be rated for no less than 5gpm. Pump must be continuous duty and of stainless-steel construction. All piping must be non-ferrous. Shall have a footprint no larger than 42? x 28? and less than 80? in height. Shall have a digital display for temperature display and control. Shall use R407c refrigerant. Shall have a highly efficient scroll compressor. Shall include at least a 1-year parts and labor warranty. Must be rated to operate outside all year.","origin":"extract"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"W912CH25QA017","place_of_performance":{"street":"W4GH CCDC GROUND VEHICLE SYS.6501 E 11 MILE ROAD SHIPPING AND RECEIVING BLDG 249WARREN, MI 48397-5000"},"product_service_code":"4140"}],"due_at":"2025-06-24T19:00:00Z","due_date":"2025-06-24","closes_at":"2025-06-24T19:00:00Z","awardable":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912CH","office_name":"W6QK ACC- DTA","state":"MI","county":"26099","county_name":"Macomb County","city":"2684000","city_name":"Warren","country":null,"winner_key":"QGCRLLLCWD45","amount":null,"linked_awards":2,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z","principal_notice_id":"1f4722092b21443bac717b987e0f0d09","description":{"text":"FLUID CHILLER:61,000 BTU?s / Hr Inlet /Outlet Piping needs to be 11/4? NPT. Pump Specifications must be 18 GMP at 38 PSI. Voltage / Phase must be 230/1, 230/3, 460/3Rated load amps at 11A@460/3. Dimensions must be 42?L X 28?W X 66?H. Dry Weight must be approximately 760 lbs. Chiller outlet temp should be 50 degrees Fahrenheit. Must have at least a 26-gallon reservoir. Chiller pump must be rated for no less than 5gpm. Pump must be continuous duty and of stainless-steel construction. All piping must be non-ferrous. Shall have a footprint no larger than 42? x 28? and less than 80? in height. Shall have a digital display for temperature display and control. Shall use R407c refrigerant. Shall have a highly efficient scroll compressor. Shall include at least a 1-year parts and labor warranty. Must be rated to operate outside all year.","html":null,"origin":"extract"},"contacts":[{"name":"JUDY-ANN LAWRENCE","role":"primary","email":"judy-ann.v.lawrence.civ@army.mil","phone":"5206726507"}],"place_of_performance":{"street":"W4GH CCDC GROUND VEHICLE SYS.6501 E 11 MILE ROAD SHIPPING AND RECEIVING BLDG 249WARREN, MI 48397-5000"},"office_address":{"zip":"48397-5000","city":"WARREN","state":"MI","country":"USA"},"naics_codes":["333413"],"award":null,"attachments":[],"awards":[{"award_key":"CONT_AWD_W912CH25CA013_9700_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_W912CH25CA013_9700_-NONE-_-NONE-/","piid":"W912CH25CA013","parent_piid":null,"award_type":"DEFINITIVE CONTRACT","vendor_key":"QGCRLLLCWD45","recipient_name":"KIJERO, LLC","recipient_uei":"QGCRLLLCWD45","recipient_cage":"9WH06","recipient_city":"MORGAN HILL","recipient_state":"CA","sub_name":"Department of the Army","office_name":"W6QK ACC- DTA","office_key":"o-W912CH","first_action_date":"2025-09-09","last_action_date":"2025-09-09","actions":1,"obligated":"17545.00","current_total_value":"17545.00","potential_total_value":"17545.00","naics":"333413","psc":"4140","extent_competed":"COMPETED UNDER SAP","set_aside":"SMALL BUSINESS SET ASIDE - TOTAL","offers_received":15,"description":"THIS REQUIREMENT IS TO PURCHASE A FLUID CHILLER","method":"solicitation","confidence":"high","evidence":["solicitation number W912CH25QA017 equals the FPDS solicitation identifier","same awarding office W912CH"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"PANDTA26P0000031111","latest_notice_id":"9b5d629f1e254654832522ec0e4a4f0e","title":"HMEE IV FOLLOW-ON EFFORT","solicitation_number":"PANDTA-26-P-0000031111","notice_type":"r","first_type":"r","first_posted":"2026-08-04","last_posted":"2026-09-01","notices":2,"due_at":"2026-09-17T21:00:00Z","due_date":"2026-09-17","closes_at":"2026-09-17T21:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912CH","office_name":"W6QK ACC- DTA","naics":null,"psc":"2420","set_aside":null,"state":"MI","county":"26099","county_name":"Macomb County","city":"2684000","city_name":"Warren","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"1005016749971","latest_notice_id":"44dad79c782b4e9c855af7da2cf5668f","title":"Sources Sought_Upper Receiver and Suppressor Kit","solicitation_number":"1005_01_674_9971","notice_type":"r","first_type":"r","first_posted":"2026-09-02","last_posted":"2026-09-02","notices":1,"due_at":"2026-09-18T15:00:00Z","due_date":"2026-09-18","closes_at":"2026-09-18T15:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912CH","office_name":"W6QK ACC- DTA","naics":null,"psc":null,"set_aside":null,"state":"MI","county":"26099","county_name":"Macomb County","city":"2684000","city_name":"Warren","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"W912CH26B0009","latest_notice_id":"ba74e5edddb44233ac371a5c7de3a439","title":"Solicitation: Parts Kit, Hydraulic Pump ( NSN: 4320-01-086-6793)","solicitation_number":"W912CH-26-B-0009","notice_type":"o","first_type":"o","first_posted":"2026-08-18","last_posted":"2026-09-03","notices":5,"due_at":"2026-09-18T17:30:00Z","due_date":"2026-09-18","closes_at":"2026-09-18T17:30:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912CH","office_name":"W6QK ACC- DTA","naics":"336992","psc":"4320","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"W912CH26BA010","latest_notice_id":"da22fd625ae7481580579adf197d8a42","title":"Solicitation: Type V Airdrop Main Panel Assembly NSN: 1670-01-304-3006","solicitation_number":"W912CH-26-B-A010","notice_type":"o","first_type":"r","first_posted":"2026-06-16","last_posted":"2026-09-08","notices":7,"due_at":"2026-09-18T20:00:00Z","due_date":"2026-09-18","closes_at":"2026-09-18T20:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912CH","office_name":"W6QK ACC- DTA","naics":"332510","psc":"1670","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"ACCDTACISEEAAD","latest_notice_id":"452dae342ba54d57b6a5b7fab07481af","title":"Sources Sought Enhanced Electronic Automatic Activation Device","solicitation_number":"ACC_DTA_CIS-EEAAD","notice_type":"r","first_type":"r","first_posted":"2026-09-08","last_posted":"2026-09-08","notices":1,"due_at":"2026-09-23T16:00:00Z","due_date":"2026-09-23","closes_at":"2026-09-23T16:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912CH","office_name":"W6QK ACC- DTA","naics":"314999","psc":"1670","set_aside":null,"state":"MA","county":"25017","county_name":"Middlesex County","city":"2501743895","city_name":"Natick","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"}]}