{"canonical":"https://abierto.us/opportunities/w912bv24r0101","key":"W912BV24R0101","url":"https://abierto.us/opportunities/w912bv24r0101","title":"Denison Switchyard Power Circuit Breakers Replacement at Red River Watershed, Denison Powerhouse, Texas","solicitation_number":"W912BV24R0101","notice_type":"o","open":false,"response_deadline":"2024-06-21T19:00:00Z","first_posted":"2024-03-26","last_posted":"2024-05-30","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE ARMY","office":"W076 ENDIST TULSA","naics":"335313","psc":"5925","set_aside":"SBA","place_state":"TX","place_county":"48181","place_county_name":"Grayson County","place_city":"4819900","place_city_name":"Denison","winner":null,"award_amount":null,"publications":[{"notice_id":"437eb80ff5dc410ca64b1f00da8bc34c","title":"Denison Switchyard Power Circuit Breakers Replacement, Red River Watershed, Denison Powerhouse, Texas","solicitation_number":"W912BV24R0101","notice_type":"p","base_type":"p","posted":"2024-03-26","posted_at":null,"due_at":"2024-04-10T17:00:00Z","due_date":"2024-04-10","cancelled":null,"archived":null,"archive_date":"2024-04-25","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/437eb80ff5dc410ca64b1f00da8bc34c/view","enriched":false,"history":[]},{"notice_id":"934530a14e0d45c7b11138ca66c2b338","title":"Denison Switchyard Power Circuit Breakers Replacement at Red River Watershed, Denison Powerhouse, Texas","solicitation_number":"W912BV24R0101","notice_type":"o","base_type":"o","posted":"2024-05-01","posted_at":null,"due_at":"2024-05-31T19:00:00Z","due_date":"2024-05-31","cancelled":null,"archived":null,"archive_date":"2025-05-01","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/934530a14e0d45c7b11138ca66c2b338/view","enriched":false,"history":[]},{"notice_id":"a2c9a73060604655a073b5e6579adb35","title":"Denison Switchyard Power Circut Breakers Replacement at Red River Watershed, Denison Powerhouse, Texas","solicitation_number":"W912BV24R0101","notice_type":"o","base_type":"o","posted":"2024-05-01","posted_at":null,"due_at":"2024-05-31T19:00:00Z","due_date":"2024-05-31","cancelled":null,"archived":null,"archive_date":"2025-05-01","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/a2c9a73060604655a073b5e6579adb35/view","enriched":false,"history":[]},{"notice_id":"767008e09e3249f2a82c1216355b644f","title":"Denison Switchyard Power Circuit Breakers Replacement at Red River Watershed, Denison Powerhouse, Texas","solicitation_number":"W912BV24R0101","notice_type":"o","base_type":"o","posted":"2024-05-10","posted_at":null,"due_at":"2024-05-31T19:00:00Z","due_date":"2024-05-31","cancelled":null,"archived":null,"archive_date":"2025-05-10","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/767008e09e3249f2a82c1216355b644f/view","enriched":false,"history":[]},{"notice_id":"d867ff1a15c54175b4259d58300c849a","title":"Denison Switchyard Power Circuit Breakers Replacement at Red River Watershed, Denison Powerhouse, Texas","solicitation_number":"W912BV24R0101","notice_type":"o","base_type":"o","posted":"2024-05-15","posted_at":null,"due_at":"2024-05-31T19:00:00Z","due_date":"2024-05-31","cancelled":null,"archived":null,"archive_date":"2025-05-10","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/d867ff1a15c54175b4259d58300c849a/view","enriched":false,"history":[]},{"notice_id":"113e3dfaeeec4703a3cccfc2a37cb84b","title":"Denison Switchyard Power Circuit Breakers Replacement at Red River Watershed, Denison Powerhouse, Texas","solicitation_number":"W912BV24R0101","notice_type":"o","base_type":"o","posted":"2024-05-30","posted_at":null,"due_at":"2024-06-21T19:00:00Z","due_date":"2024-06-21","cancelled":null,"archived":null,"archive_date":"2025-05-30","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/113e3dfaeeec4703a3cccfc2a37cb84b/view","enriched":false,"history":[]}],"latest_notice_id":"113e3dfaeeec4703a3cccfc2a37cb84b","first_type":"p","notices":[{"dates":{"posted":"2024-03-26","response_deadline":{"raw":"2024-04-10T12:00:00-05:00","utc":"2024-04-10T17:00:00Z","date":"2024-04-10","time":"12:00:00","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/437eb80ff5dc410ca64b1f00da8bc34c/view"},"naics":{"codes":["335313"],"primary":"335313"},"title":"Denison Switchyard Power Circuit Breakers Replacement, Red River Watershed, Denison Powerhouse, Texas","agency":{"office":{"code":"W912BV","name":"W076 ENDIST TULSA"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"74137-4290","city":"TULSA","state":"OK","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-04-25","archive_type":"auto15"},"contacts":[{"name":"Cheyenne Redemann","role":"primary","email":"Cheyenne.A.Redemann@usace.army.mil","phone":"9186697073"},{"name":"Shawn Brady","role":"secondary","email":"Shawn.G.Brady@usace.army.mil","phone":"9186694984"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"437eb80ff5dc410ca64b1f00da8bc34c","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"4fc44e1e3a7edcfd99d316d634c26c5d2e0abc19e836fc1051687f37ad7be1b4","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"1. Action Code: This is a Pre-Solicitation notice. 2. Date: 26 March 2024 3. Contracting Office Address: USACE CEST-CT-E 2488 E. 81st Street Tulsa, Oklahoma 74137-4290 4. Classification Code: 59 – Electrical/Electronic Eqpt Compnts 5. Subject Title: Denison Switchyard Power Circuit Breakers Replacement 6. Solicitation Number: W912BV24R0101 7. Contact(s) Points: Name: Cheyenne Redemann Shawn Brady Phone: 918-669-7073 918-669-4984 Email: Cheyenne.A.Redemann@usace.army.mil; Shawn.G.Brady@usace.army.mil 8. Important: This notice does not constitute a request for proposal, request for quote, or invitation for bid. The intent of this notice is to provide the pre-solicitation notice required by FAR 5.2- Synopsis of Proposed Contract Actions in preparation for release of the Request for Proposal (RFP) later date. 9. Description: The RFP for this project is expected to be issued on or about the middle of April 2024. The Proposal due date is planned on or about the middle of May 2024. The North American Industry Code Standard (NAICS) is NAICS 335313 – Switchgear and Switchboard Apparatus Manufacturing, and the size standard is 1,250 employees. The planned procurement method is contracting by Lowest Price Technically Acceptable (LPTA) in accordance with FAR part 15. The resulting contract is planned to be a firm-fixed price (FFP) contract for the work described in the Statement of Work which will be provided with the solicitation. The US ARMY CORPS OF ENGINEERS is seeking proposals for replacing three of the six switchyard Power Circuit Breakers (PCBs), PCB power and control wiring, PCB bushing CT secondary circuit wiring, and PCB pole-to-HOD switch pole jumpers (stingers). All equipment will be replaced with new equipment of equivalent ratings. Work also includes supplying PCBs, PCBs disassembly, and PCBs installation. 10. Place of Contract Performance: The preponderance of the work to be placed under this contract is expected to be performed at Red River Watershed, Denison Powerhouse, Texas. 11. Set Aside Status: This is a 100% Small Business Set-Aside. 12. Additional Details: THIS SOLICITATION WILL BE OFFERED IN ELECTRONIC FORMAT ONLY. NO HARD COPIES WILL BE PROVIDED. Offerors can view and/or download the RFP and attachments at https://www.sam.gov when the RFP is posted. Interested parties can register under the Interested Vendors List at FBO. This will be the only method of amendment distribution; therefore, it is the OFFERORS’ RESPONSIBILITY TO CHECK THE WEBSITE PERIODICALLY FOR ANY AMENDMENTS TO THE SOLICITATION. Prospective Offerors MUST register themselves on the website. Prospective Offerors must also be registered with the System for Award Management (SAM) at https://www.sam.gov/portal/public/SAM in order to participate in this procurement. 13. Period of Performance (POP): The POP is estimated for 900 days after the Notice to Proceed. 14. No reimbursement will be made for any costs associated with providing information in response to this synopsis or any follow up information requests.","origin":"extract"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"W912BV24R0101","place_of_performance":{"city":{"name":"Denison"},"state":{"code":"TX"},"country":{"code":"USA"}},"product_service_code":"5925"},{"dates":{"posted":"2024-05-01","response_deadline":{"raw":"2024-05-31T14:00:00-05:00","utc":"2024-05-31T19:00:00Z","date":"2024-05-31","time":"14:00:00","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/934530a14e0d45c7b11138ca66c2b338/view"},"naics":{"codes":["335313"],"primary":"335313"},"title":"Denison Switchyard Power Circuit Breakers Replacement at Red River Watershed, Denison Powerhouse, Texas","agency":{"office":{"code":"W912BV","name":"W076 ENDIST TULSA"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"74137-4290","city":"TULSA","state":"OK","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2025-05-01","archive_type":"auto_custom"},"contacts":[{"name":"Cheyenne Redemann","role":"primary","email":"cheyenne.a.redemann@usace.army.mil","phone":"9186697073"},{"name":"Shawn Brady","role":"secondary","email":"shawn.brady@usace.army.mil","phone":"9186694984"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"934530a14e0d45c7b11138ca66c2b338","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"57851d58833e6eed818767c1cb8743088eec0f9343021043f916d7a2d141a94b","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Denison Switchyard Power Circuit Breakers Replacement at Red River Watershed, Denison Powerhouse, Texas. This project replaces three of the six switchyard Power Circuit Breakers (PCBs), PCB power and control wiring, PCB bushing CT secondary circuit wiring, and PCB pole-to-HOD switch pole jumpers (stingers). All equipment will be replaced with new equipment of equivalent ratings. This is a 100% Small Business Set-Aside competitive solicitation for a firm-fixed price contract to be awarded under the best value continuum using the Lowest Price Technically Acceptable (LPTA) process in accordance with FAR 15.101-2. The Contractor will be required to commence work within 10 days after Notice to Proceed (NTP) and complete the work within the proposed number of calendar days (Not to Exceed 900 days) after receipt of NTP. Provisions will be included for Liquidated Damages in case of failure to complete the work in the allowed time. Performance and Payment Bonds will be required. NOTE: Specifications and Drawings contain Controlled Unclassified Information (CUI) and access to these documents is restricted as per 23 CFR 2002 and Presidential Policy Directive 21. Please contact the contract specialist, Cheyenne Redemann at Cheyenne.A.Redemann@usace.army.mil to request access via email with the solicitation number, your company name, and cage code in the subject line (i.e. W912BV24R0101 / COMPANY XYZ / CAGE CODE). Vendors must be registered and active in SAM.gov and Procurement Integrated Enterprise Environment (PIEE) to obtain approval for access to specifications and drawings and submit proposals. Reference the solicitation for instructions on registration and access.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"W912BV24R0101","product_service_code":"5925"},{"dates":{"posted":"2024-05-01","response_deadline":{"raw":"2024-05-31T14:00:00-05:00","utc":"2024-05-31T19:00:00Z","date":"2024-05-31","time":"14:00:00","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/a2c9a73060604655a073b5e6579adb35/view"},"naics":{"codes":["335313"],"primary":"335313"},"title":"Denison Switchyard Power Circut Breakers Replacement at Red River Watershed, Denison Powerhouse, Texas","agency":{"office":{"code":"W912BV","name":"W076 ENDIST TULSA"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"74137-4290","city":"TULSA","state":"OK","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2025-05-01","archive_type":"auto_custom"},"contacts":[{"name":"Cheyenne Redemann","role":"primary","email":"cheyenne.a.redemann@usace.army.mil","phone":"9186697073"},{"name":"Shawn Brady","role":"secondary","email":"shawn.brady@usace.army.mil","phone":"9186694984"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"a2c9a73060604655a073b5e6579adb35","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"7b4b037fd5462930c2ad49adc36992ab1a9525fcdf0f92727d7f917b8dd9a9a6","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Denison Switchyard Power Circut Breakers Replacement at Red River Watershed, Denison Powerhouse, Texas. This project replaces three of the six switchyard Power Circuit Breakers (PCBs), PCB power and control wiring, PCB bushing CT secondary circuit wiring, and PCB pole-to-HOD switch pole jumpers (stingers). All equipment will be replaced with new equipment of equivalent ratings. This is a 100% Small Business Set-Aside competitive solicitation for a firm-fixed price contract to be awarded under the best value continuum using the Lowest Price Technically Acceptable (LPTA) process in accordance with FAR 15.101-2. The Contractor will be required to commence work within 10 days after Notice to Proceed (NTP) and complete the work within the proposed number of calendar days (Not to Exceed 900 days) after receipt of NTP. Provisions will be included for Liquidated Damages in case of failure to complete the work in the allowed time. Performance and Payment Bonds will be required. NOTE: Specifications and Drawings contain Controlled Unclassified Information (CUI) and access to these documents is restricted as per 23 CFR 2002 and Presidential Policy Directive 21. Please contact the contract specialist, Cheyenne Redemann at Cheyenne.A.Redemann@usace.army.mil to request access via email with the solicitation number, your company name, and cage code in the subject line (i.e. W912BV24R0101 / COMPANY XYZ / CAGE CODE). Vendors must be registered and active in SAM.gov and Procurement Integrated Enterprise Environment (PIEE) to obtain approval for access to specifications and drawings and submit proposals. Reference the solicitation for instructions on registration and access.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"W912BV24R0101","product_service_code":"5925"},{"dates":{"posted":"2024-05-10","response_deadline":{"raw":"2024-05-31T14:00:00-05:00","utc":"2024-05-31T19:00:00Z","date":"2024-05-31","time":"14:00:00","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/767008e09e3249f2a82c1216355b644f/view"},"naics":{"codes":["335313"],"primary":"335313"},"title":"Denison Switchyard Power Circuit Breakers Replacement at Red River Watershed, Denison Powerhouse, Texas","agency":{"office":{"code":"W912BV","name":"W076 ENDIST TULSA"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"74137-4290","city":"TULSA","state":"OK","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2025-05-10","archive_type":"auto_custom"},"contacts":[{"name":"Cheyenne Redemann","role":"primary","email":"cheyenne.a.redemann@usace.army.mil","phone":"9186697073"},{"name":"Shawn Brady","role":"secondary","email":"shawn.brady@usace.army.mil","phone":"9186694984"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"767008e09e3249f2a82c1216355b644f","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"7d60be70c0e3202fccf3f6ec53e96b22c22a43e887e92dc947531145be6cb7d2","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Denison Switchyard Power Circuit Breakers Replacement at Red River Watershed, Denison Powerhouse, Texas. This project replaces three of the six switchyard Power Circuit Breakers (PCBs), PCB power and control wiring, PCB bushing CT secondary circuit wiring, and PCB pole-to-HOD switch pole jumpers (stingers). All equipment will be replaced with new equipment of equivalent ratings. This is a 100% Small Business Set-Aside competitive solicitation for a firm-fixed price contract to be awarded under the best value continuum using the Lowest Price Technically Acceptable (LPTA) process in accordance with FAR 15.101-2. The Contractor will be required to commence work within 10 days after Notice to Proceed (NTP) and complete the work within the proposed number of calendar days (Not to Exceed 900 days) after receipt of NTP. Provisions will be included for Liquidated Damages in case of failure to complete the work in the allowed time. Performance and Payment Bonds will be required. NOTE: Specifications and Drawings contain Controlled Unclassified Information (CUI) and access to these documents is restricted as per 23 CFR 2002 and Presidential Policy Directive 21. Please contact the contract specialist, Cheyenne Redemann at Cheyenne.A.Redemann@usace.army.mil to request access via email with the solicitation number, your company name, and cage code in the subject line (i.e. W912BV24R0101 / COMPANY XYZ / CAGE CODE). Vendors must be registered and active in SAM.gov and Procurement Integrated Enterprise Environment (PIEE) to obtain approval for access to specifications and drawings and submit proposals. Reference the solicitation for instructions on registration and access. AM 0001 updates the Site Visit information.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"W912BV24R0101","product_service_code":"5925"},{"dates":{"posted":"2024-05-15","response_deadline":{"raw":"2024-05-31T14:00:00-05:00","utc":"2024-05-31T19:00:00Z","date":"2024-05-31","time":"14:00:00","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/d867ff1a15c54175b4259d58300c849a/view"},"naics":{"codes":["335313"],"primary":"335313"},"title":"Denison Switchyard Power Circuit Breakers Replacement at Red River Watershed, Denison Powerhouse, Texas","agency":{"office":{"code":"W912BV","name":"W076 ENDIST TULSA"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"74137-4290","city":"TULSA","state":"OK","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2025-05-10","archive_type":"auto_custom"},"contacts":[{"name":"Cheyenne Redemann","role":"primary","email":"cheyenne.a.redemann@usace.army.mil","phone":"9186697073"},{"name":"Shawn Brady","role":"secondary","email":"shawn.brady@usace.army.mil","phone":"9186694984"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"d867ff1a15c54175b4259d58300c849a","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"ef816c3c27b50719e1fe6b72a39b39fcdaa4590305ddd7657b7cca8bc11cbcbe","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Denison Switchyard Power Circuit Breakers Replacement at Red River Watershed, Denison Powerhouse, Texas. This project replaces three of the six switchyard Power Circuit Breakers (PCBs), PCB power and control wiring, PCB bushing CT secondary circuit wiring, and PCB pole-to-HOD switch pole jumpers (stingers). All equipment will be replaced with new equipment of equivalent ratings. This is a 100% Small Business Set-Aside competitive solicitation for a firm-fixed price contract to be awarded under the best value continuum using the Lowest Price Technically Acceptable (LPTA) process in accordance with FAR 15.101-2. The Contractor will be required to commence work within 10 days after Notice to Proceed (NTP) and complete the work within the proposed number of calendar days (Not to Exceed 900 days) after receipt of NTP. Provisions will be included for Liquidated Damages in case of failure to complete the work in the allowed time. Performance and Payment Bonds will be required. NOTE: Specifications and Drawings contain Controlled Unclassified Information (CUI) and access to these documents is restricted as per 23 CFR 2002 and Presidential Policy Directive 21. Please contact the contract specialist, Cheyenne Redemann at Cheyenne.A.Redemann@usace.army.mil to request access via email with the solicitation number, your company name, and cage code in the subject line (i.e. W912BV24R0101 / COMPANY XYZ / CAGE CODE). Vendors must be registered and active in SAM.gov and Procurement Integrated Enterprise Environment (PIEE) to obtain approval for access to specifications and drawings and submit proposals. Reference the solicitation for instructions on registration and access. AM 0001 updates the Site Visit information.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"W912BV24R0101","product_service_code":"5925"},{"dates":{"posted":"2024-05-30","response_deadline":{"raw":"2024-06-21T14:00:00-05:00","utc":"2024-06-21T19:00:00Z","date":"2024-06-21","time":"14:00:00","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/113e3dfaeeec4703a3cccfc2a37cb84b/view"},"naics":{"codes":["335313"],"primary":"335313"},"title":"Denison Switchyard Power Circuit Breakers Replacement at Red River Watershed, Denison Powerhouse, Texas","agency":{"office":{"code":"W912BV","name":"W076 ENDIST TULSA"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"74137-4290","city":"TULSA","state":"OK","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2025-05-30","archive_type":"auto_custom"},"contacts":[{"name":"Cheyenne Redemann","role":"primary","email":"cheyenne.a.redemann@usace.army.mil","phone":"9186697073"},{"name":"Shawn Brady","role":"secondary","email":"shawn.brady@usace.army.mil","phone":"9186694984"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"113e3dfaeeec4703a3cccfc2a37cb84b","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"5f70eb0d5107589faf7cada2d14a20c5541d9331a7351aedc161eb2d41aca048","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Denison Switchyard Power Circuit Breakers Replacement at Red River Watershed, Denison Powerhouse, Texas. This project replaces three of the six switchyard Power Circuit Breakers (PCBs), PCB power and control wiring, PCB bushing CT secondary circuit wiring, and PCB pole-to-HOD switch pole jumpers (stingers). All equipment will be replaced with new equipment of equivalent ratings. This is a 100% Small Business Set-Aside competitive solicitation for a firm-fixed price contract to be awarded under the best value continuum using the Lowest Price Technically Acceptable (LPTA) process in accordance with FAR 15.101-2. The Contractor will be required to commence work within 10 days after Notice to Proceed (NTP) and complete the work within the proposed number of calendar days (Not to Exceed 900 days) after receipt of NTP. Provisions will be included for Liquidated Damages in case of failure to complete the work in the allowed time. Performance and Payment Bonds will be required. NOTE: Specifications and Drawings contain Controlled Unclassified Information (CUI) and access to these documents is restricted as per 23 CFR 2002 and Presidential Policy Directive 21. Please contact the contract specialist, Cheyenne Redemann at Cheyenne.A.Redemann@usace.army.mil to request access via email with the solicitation number, your company name, and cage code in the subject line (i.e. W912BV24R0101 / COMPANY XYZ / CAGE CODE). Vendors must be registered and active in SAM.gov and Procurement Integrated Enterprise Environment (PIEE) to obtain approval for access to specifications and drawings and submit proposals. Reference the solicitation for instructions on registration and access. AM 0001 updates the Site Visit information. AM 0002 extends the proposal due date.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"W912BV24R0101","product_service_code":"5925"}],"due_at":"2024-06-21T19:00:00Z","due_date":"2024-06-21","closes_at":"2024-06-21T19:00:00Z","awardable":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912BV","office_name":"W076 ENDIST TULSA","state":"TX","county":"48181","county_name":"Grayson County","city":"4819900","city_name":"Denison","country":"USA","winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z","principal_notice_id":"113e3dfaeeec4703a3cccfc2a37cb84b","description":{"text":"Denison Switchyard Power Circuit Breakers Replacement at Red River Watershed, Denison Powerhouse, Texas. This project replaces three of the six switchyard Power Circuit Breakers (PCBs), PCB power and control wiring, PCB bushing CT secondary circuit wiring, and PCB pole-to-HOD switch pole jumpers (stingers). All equipment will be replaced with new equipment of equivalent ratings. This is a 100% Small Business Set-Aside competitive solicitation for a firm-fixed price contract to be awarded under the best value continuum using the Lowest Price Technically Acceptable (LPTA) process in accordance with FAR 15.101-2. The Contractor will be required to commence work within 10 days after Notice to Proceed (NTP) and complete the work within the proposed number of calendar days (Not to Exceed 900 days) after receipt of NTP. Provisions will be included for Liquidated Damages in case of failure to complete the work in the allowed time. Performance and Payment Bonds will be required. NOTE: Specifications and Drawings contain Controlled Unclassified Information (CUI) and access to these documents is restricted as per 23 CFR 2002 and Presidential Policy Directive 21. Please contact the contract specialist, Cheyenne Redemann at Cheyenne.A.Redemann@usace.army.mil to request access via email with the solicitation number, your company name, and cage code in the subject line (i.e. W912BV24R0101 / COMPANY XYZ / CAGE CODE). Vendors must be registered and active in SAM.gov and Procurement Integrated Enterprise Environment (PIEE) to obtain approval for access to specifications and drawings and submit proposals. Reference the solicitation for instructions on registration and access. AM 0001 updates the Site Visit information. AM 0002 extends the proposal due date.","html":null,"origin":"extract"},"contacts":[{"name":"Cheyenne Redemann","role":"primary","email":"cheyenne.a.redemann@usace.army.mil","phone":"9186697073"},{"name":"Shawn Brady","role":"secondary","email":"shawn.brady@usace.army.mil","phone":"9186694984"}],"place_of_performance":null,"office_address":{"zip":"74137-4290","city":"TULSA","state":"OK","country":"USA"},"naics_codes":["335313"],"award":null,"attachments":[],"awards":[],"related":[{"key":"CY1001","latest_notice_id":"927f912e73bc4f6c8615c5096f83df5d","title":"Tenkiller Replace Service Gates","solicitation_number":"CY1001","notice_type":"r","first_type":"r","first_posted":"2026-09-11","last_posted":"2026-09-11","notices":1,"due_at":"2026-09-25T19:00:00Z","due_date":"2026-09-25","closes_at":"2026-09-25T19:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912BV","office_name":"W076 ENDIST TULSA","naics":"237990","psc":"Z2QA","set_aside":null,"state":"OK","county":"40135","county_name":"Sequoyah County","city":"4030300","city_name":"Gore","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"D4EDAA9DEB9045BEB353CDA1DF387E5B","latest_notice_id":"d4edaa9deb9045beb353cda1df387e5b","title":"Webbers Falls Unit 1 Speed Increaser Gearbox Replacement","solicitation_number":"CY605","notice_type":"r","first_type":"r","first_posted":"2026-08-27","last_posted":"2026-08-27","notices":1,"due_at":"2026-09-30T19:00:00Z","due_date":"2026-09-30","closes_at":"2026-09-30T19:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912BV","office_name":"W076 ENDIST TULSA","naics":"237990","psc":"Y1NZ","set_aside":null,"state":"OK","county":"40101","county_name":"Muskogee County","city":"4079650","city_name":"Webbers Falls","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"W912BV26QA095","latest_notice_id":"084a3dda58b84dcea4655b20cf57bb04","title":"Fall River Lake and Dam Damsite Park Lagoon Repair","solicitation_number":"W912BV26QA095","notice_type":"o","first_type":"o","first_posted":"2026-09-09","last_posted":"2026-09-15","notices":2,"due_at":"2026-10-06T20:00:00Z","due_date":"2026-10-06","closes_at":"2026-10-06T20:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912BV","office_name":"W076 ENDIST TULSA","naics":"237990","psc":"Z2KA","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"W912BV26RA016","latest_notice_id":"7fb2b156bb304762a8d895c825c5c6af","title":"Child Development Center (CDC), Tinker Air Force Base, Oklahoma","solicitation_number":"W912BV26RA016","notice_type":"o","first_type":"p","first_posted":"2026-08-13","last_posted":"2026-09-04","notices":2,"due_at":"2026-10-30T20:00:00Z","due_date":"2026-10-30","closes_at":"2026-10-30T20:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W912BV","office_name":"W076 ENDIST TULSA","naics":"236220","psc":"Y1CZ","set_aside":null,"state":"OK","county":"40109","county_name":"Oklahoma County","city":"4048350","city_name":"Midwest City","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"}]}