{"canonical":"https://abierto.us/opportunities/w9127n27ba007","key":"W9127N27BA007","url":"https://abierto.us/opportunities/w9127n27ba007","title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","solicitation_number":"W9127N27BA007","notice_type":"o","open":true,"removed":false,"removed_at":null,"response_deadline":"2026-12-28T22:00:00Z","first_posted":"2026-10-29","last_posted":"2026-10-30","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE ARMY","office":"W071 ENDIST PORTLAND","naics":"238220","psc":"Z2EZ","set_aside":null,"place_state":"OR","place_scope":"site","site":"John Day Dam","place_state_source":"sam_street","place_evidence":"NEAR RUFUS, OREGON","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"1f35956f49d742f5af03485dbf5b3edd","title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","solicitation_number":"W9127N27BA007","notice_type":"p","base_type":"p","posted":"2026-10-29","posted_at":"2026-10-29T17:29:16.166Z","due_at":null,"due_date":null,"cancelled":false,"archived":false,"archive_date":"2027-10-29","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/1f35956f49d742f5af03485dbf5b3edd/view","enriched":true,"history":[{"index":2,"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-29T17:56:47.095Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"modify","opportunity_id":"61ff2d54f9114299950236018dce1902","solicitation_number":"W9127N27BA007","parent_opportunity_id":"1f35956f49d742f5af03485dbf5b3edd"},{"index":1,"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-29T17:29:16.166Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"1f35956f49d742f5af03485dbf5b3edd","solicitation_number":"W9127N27BA007"}]},{"notice_id":"61ff2d54f9114299950236018dce1902","title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","solicitation_number":"W9127N27BA007","notice_type":"p","base_type":"p","posted":"2026-10-29","posted_at":"2026-10-29T17:56:47.095Z","due_at":null,"due_date":null,"cancelled":false,"archived":false,"archive_date":"2027-10-29","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/61ff2d54f9114299950236018dce1902/view","enriched":true,"history":[{"index":3,"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-29T22:09:26.126Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"ccd4de596e8c4f099e9719a242d03b04","solicitation_number":"W9127N27BA007","related_opportunity_id":"61ff2d54f9114299950236018dce1902"},{"index":2,"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-29T17:56:47.095Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"modify","opportunity_id":"61ff2d54f9114299950236018dce1902","solicitation_number":"W9127N27BA007","parent_opportunity_id":"1f35956f49d742f5af03485dbf5b3edd"},{"index":1,"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-29T17:29:16.166Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"1f35956f49d742f5af03485dbf5b3edd","solicitation_number":"W9127N27BA007"}]},{"notice_id":"97e5c90d8a244e69a66a36401f3e5e4c","title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","solicitation_number":"W9127N27BA007","notice_type":"o","base_type":"o","posted":"2026-10-29","posted_at":"2026-10-29T22:16:14.444Z","due_at":"2026-12-28T22:00:00Z","due_date":"2026-12-28","cancelled":false,"archived":false,"archive_date":"2027-03-10","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/97e5c90d8a244e69a66a36401f3e5e4c/view","enriched":true,"history":[{"index":3,"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-29T22:16:14.444Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"97e5c90d8a244e69a66a36401f3e5e4c","solicitation_number":"W9127N27BA007","parent_opportunity_id":"ccd4de596e8c4f099e9719a242d03b04","related_opportunity_id":"61ff2d54f9114299950236018dce1902"},{"index":2,"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-29T22:09:26.126Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"ccd4de596e8c4f099e9719a242d03b04","solicitation_number":"W9127N27BA007","related_opportunity_id":"61ff2d54f9114299950236018dce1902"},{"index":1,"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-29T17:56:47.095Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"modify","opportunity_id":"61ff2d54f9114299950236018dce1902","solicitation_number":"W9127N27BA007","parent_opportunity_id":"1f35956f49d742f5af03485dbf5b3edd"}]},{"notice_id":"ccd4de596e8c4f099e9719a242d03b04","title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","solicitation_number":"W9127N27BA007","notice_type":"o","base_type":"p","posted":"2026-10-29","posted_at":"2026-10-29T22:09:26.126Z","due_at":"2026-12-28T22:00:00Z","due_date":"2026-12-28","cancelled":false,"archived":false,"archive_date":"2027-03-10","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/ccd4de596e8c4f099e9719a242d03b04/view","enriched":true,"history":[{"index":3,"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-29T22:16:14.444Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"97e5c90d8a244e69a66a36401f3e5e4c","solicitation_number":"W9127N27BA007","parent_opportunity_id":"ccd4de596e8c4f099e9719a242d03b04","related_opportunity_id":"61ff2d54f9114299950236018dce1902"},{"index":2,"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-29T22:09:26.126Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"ccd4de596e8c4f099e9719a242d03b04","solicitation_number":"W9127N27BA007","related_opportunity_id":"61ff2d54f9114299950236018dce1902"},{"index":1,"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-29T17:56:47.095Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"modify","opportunity_id":"61ff2d54f9114299950236018dce1902","solicitation_number":"W9127N27BA007","parent_opportunity_id":"1f35956f49d742f5af03485dbf5b3edd"}]},{"notice_id":"89b27f77366f44c48abe9bbccef3b87d","title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","solicitation_number":"W9127N27BA007","notice_type":"o","base_type":"o","posted":"2026-10-30","posted_at":"2026-10-30T16:49:07.807Z","due_at":"2026-12-28T22:00:00Z","due_date":"2026-12-28","cancelled":false,"archived":false,"archive_date":"2027-03-10","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/89b27f77366f44c48abe9bbccef3b87d/view","enriched":true,"history":[{"index":5,"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-30T16:49:07.807Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"89b27f77366f44c48abe9bbccef3b87d","solicitation_number":"W9127N27BA007","parent_opportunity_id":"ccd4de596e8c4f099e9719a242d03b04","related_opportunity_id":"61ff2d54f9114299950236018dce1902"},{"index":4,"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-30T16:17:33.105Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a26c4d09a32d41f48b7adb1113d5971a","solicitation_number":"W9127N27BA007","parent_opportunity_id":"ccd4de596e8c4f099e9719a242d03b04","related_opportunity_id":"61ff2d54f9114299950236018dce1902"},{"index":3,"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-29T22:16:14.444Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"97e5c90d8a244e69a66a36401f3e5e4c","solicitation_number":"W9127N27BA007","parent_opportunity_id":"ccd4de596e8c4f099e9719a242d03b04","related_opportunity_id":"61ff2d54f9114299950236018dce1902"},{"index":2,"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-29T22:09:26.126Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"ccd4de596e8c4f099e9719a242d03b04","solicitation_number":"W9127N27BA007","related_opportunity_id":"61ff2d54f9114299950236018dce1902"},{"index":1,"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-29T17:56:47.095Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"modify","opportunity_id":"61ff2d54f9114299950236018dce1902","solicitation_number":"W9127N27BA007","parent_opportunity_id":"1f35956f49d742f5af03485dbf5b3edd"}]},{"notice_id":"a26c4d09a32d41f48b7adb1113d5971a","title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","solicitation_number":"W9127N27BA007","notice_type":"o","base_type":"o","posted":"2026-10-30","posted_at":"2026-10-30T16:17:33.105Z","due_at":"2026-12-28T22:00:00Z","due_date":"2026-12-28","cancelled":false,"archived":false,"archive_date":"2027-03-10","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/a26c4d09a32d41f48b7adb1113d5971a/view","enriched":true,"history":[{"index":5,"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-30T16:49:07.807Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"89b27f77366f44c48abe9bbccef3b87d","solicitation_number":"W9127N27BA007","parent_opportunity_id":"ccd4de596e8c4f099e9719a242d03b04","related_opportunity_id":"61ff2d54f9114299950236018dce1902"},{"index":4,"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-30T16:17:33.105Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a26c4d09a32d41f48b7adb1113d5971a","solicitation_number":"W9127N27BA007","parent_opportunity_id":"ccd4de596e8c4f099e9719a242d03b04","related_opportunity_id":"61ff2d54f9114299950236018dce1902"},{"index":3,"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-29T22:16:14.444Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"97e5c90d8a244e69a66a36401f3e5e4c","solicitation_number":"W9127N27BA007","parent_opportunity_id":"ccd4de596e8c4f099e9719a242d03b04","related_opportunity_id":"61ff2d54f9114299950236018dce1902"},{"index":2,"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-29T22:09:26.126Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"ccd4de596e8c4f099e9719a242d03b04","solicitation_number":"W9127N27BA007","related_opportunity_id":"61ff2d54f9114299950236018dce1902"},{"index":1,"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-29T17:56:47.095Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"modify","opportunity_id":"61ff2d54f9114299950236018dce1902","solicitation_number":"W9127N27BA007","parent_opportunity_id":"1f35956f49d742f5af03485dbf5b3edd"}]}],"latest_notice_id":"a26c4d09a32d41f48b7adb1113d5971a","first_type":"p","notices":[{"dates":{"posted":"2026-10-29","posted_at":"2026-10-29T17:29:16.166Z","created_at":"2026-10-29T17:29:16.096Z","modified_at":"2026-10-29T17:56:47.095Z"},"links":{"sam":"https://sam.gov/workspace/contract/opp/1f35956f49d742f5af03485dbf5b3edd/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","agency":{"office":{"code":"W9127N","name":"W071 ENDIST PORTLAND"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"97204-3495","city":"PORTLAND","state":"OR","country":"USA"},"organization_id":"100255230","organization_type":"OFFICE"},"status":{"active":true,"latest":false,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2027-10-29","archive_type":"auto_custom"},"history":[{"index":2,"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-29T17:56:47.095Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"modify","opportunity_id":"61ff2d54f9114299950236018dce1902","solicitation_number":"W9127N27BA007","parent_opportunity_id":"1f35956f49d742f5af03485dbf5b3edd"},{"index":1,"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-29T17:29:16.166Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"1f35956f49d742f5af03485dbf5b3edd","solicitation_number":"W9127N27BA007"}],"contacts":[{"name":"Aragon Liebzeit","role":"primary","email":"ARAGON.N.LIEBZEIT@USACE.ARMY.MIL","phone":"5038084610"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"1f35956f49d742f5af03485dbf5b3edd","lineage_id":"1f35956f49d742f5af03485dbf5b3edd","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-30T03:59:43.490202899Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"fee52df21fdaac6760f6309dc6a4b5e5-27\"","fetched_at":"2026-10-30T03:37:02.893800920Z","row_sha256":"89c3c8357c66ed04d697be0d45655e3fb87cf525c263cdb5b9f0a8e051c8e02f","last_modified":"2026-10-30T03:30:45Z"},"updated_at":"2026-10-30T03:59:43.490202899Z","first_seen_at":"2026-10-30T03:37:02.893800920Z"},"description":{"html":"NOTICE OF SOLICITATION NUMBER CHANGEThe John Day Powerhouse HVAC Upgrades acquisition, previously announced under presolicitation notice number W9127N26BA006, is now identified as W9127N27BA007 due to the fiscal-year transition. This presolicitation notice continues the announcement of the same acquisition under the new number; it does not represent a separate requirement. All subsequent notices and solicitation documents for this acquisition will reference solicitation number W9127N27BA007.The original presolicitation notice under W9127N26BA006 is available here: https://sam.gov/workspace/contract/opp/7efeefdf2b3c493d89f14b5ce67ff62a/view The U.S. Army Corps of Engineers (USACE) Portland District (NWP) has a requirement for HVAC upgrades at the John Day Dam (JDA) Powerhouse.  JDA is approximately 109 miles east of Portland, Oregon, and 275 miles from Seattle, Washington. JDA spans two states, with Units 1 through 14 located in Sherman County, Oregon, and Units 15 and 16 in Klickitat County, Washington. Cybersecurity Maturity Model Certification (CMMC). This solicitation requires the contractor and/or subcontractor(s) information system to process, store, or transmit Federal Contract Information (FCI) or Controlled Unclassified Information (CUI), and requires the contractor and/or subcontractor(s) to comply with CMMC requirements.  The CMMC level required by this solicitation is: CMMC Level 2 (Self). This CMMC level, or higher, is a condition of award. Prior to award, the apparent successful offeror must have a current CMMC status at Level 2 (Self), or higher, posted in SPRS for each relevant CMMC UID in order to remain eligible for award; failure to meet this requirement will render the offeror ineligible for contract award. CMMC requirements apply to prime contractors and subcontractors throughout the supply chain at all tiers that will process, store, or transmit any FCI or CUI on contractor information systems in the performance of this DoD contract or subcontract. Prime contractors shall comply and shall require subcontractors to comply with and to flow down CMMC requirements, such that compliance will be required throughout the supply chain at all tiers with the applicable CMMC level and assessment type for each subcontract as follows: If a subcontractor will only process, store, or transmit FCI (and not CUI) in performance of the subcontract, then a CMMC status of Level 1 (Self) is required for that subcontractor. If a subcontractor will process, store, or transmit CUI in performance of the subcontract, then a CMMC status of Level 2 (Self), or higher, is required for that subcontractor, and must be current in SPRS prior to subcontract award. Prime contractors are responsible for ensuring that all covered subcontractors obtain and maintain the appropriate CMMC level and assessment type for the information they will process, store, or transmit during performance. For this solicitation, contractors requesting access to documents containing FCI or CUI must have an active SAM registration and a current NIST SP 800 171 assessment with at least a Basic confidence level recorded in SPRS. Summary of Work:  Work includes but is not limited to the following:  1.\tComplete replacement of the primary and installation of secondary chillers on two chilled water loops serving the majority of the Powerhouse galleries.2.\tDemolition and removal of the existing system and installation of four new chiller skid packages totaling approximately 600 tons of refrigeration capacity.3.\tNew electrical feeds, chilled water pumps, piping, and air handler units, with selective reuse of existing components.4.\tSystems must be integrated into a new automated digital HVAC control system.5.\tHalf of the new systems will be water-cooled; half will be converted to air-cooled. For the air-cooled units, roof-mounted air-cooled condensers will be installed, requiring roof penetrations, piping, and building modifications.6.\tHVAC upgrades include new intake and exhaust ducting to prevent smoke propagation through the building in the event of fire, and fire protection measures at all penetrations.7.\tHVAC and the building fire protection systems must be fully integrated, replacing all existing pneumatic controls with an integrated digital control system which is capable of functioning to selectively shut down the HVAC to isolate sectors in the event of a fire or smoke event.8.\tThe work includes mechanical and controls provisions for free cooling using passive outside air during cold nights and modifications to existing intakes, louvers, and penetrations to support smoke ventilation.9.\tLocalized HVAC units such as mini-splits will be installed for specific spaces, with new electrical supplies, piping, insulation, penetrations, and data reporting to the central HVAC control system.10.\tWork will be performed in an active, operational Powerhouse with 6000A, 13.8kV busbars and other heavy electrical equipment, including areas below headwater with nuisance water intrusion risks.11.\tCertain pumps must remain operational throughout construction, presenting noise and safety hazards that must be managed.12.\tThe existing fire suppression system must remain active during construction and be recommissioned upon project completion.13.\tWork includes ductwork installation and protection of floor penetrations in close proximity to operational high-voltage electrical busbars, emphasizing strict delineation and safety control of work areas.14.\tNew systems to be installed must not use refrigerants subject to future refrigerant phase-out schedules (no refrigerant subject to phase-out at any point in the future may be used). 15.\tWork includes extensive structural penetrations and modifications to support permanent equipment installation including piping, ductwork and new condensing systems.16.\tAsbestos abatement and lead mitigation may be required.  The anticipated completion date for physical construction is 1,004 calendar days after receiving the Notice to Proceed.    The solicitation will be issued as an Invitation for Bids (IFB). This acquisition will result in a single firm-fixed-price contract. The estimated magnitude of construction is between $25M and $100M. This procurement is unrestricted/full and open competition. The North American Industry Classification System (NAICS) code for this action is 238220; Plumbing, Heating, and Air-Conditioning Contractors with a small business size standard of $19M.  One or more of the items under this acquisition is subject to the World Trade Organization Government Procurement Agreement and Free Trade Agreements. This synopsis is not a request for quotes (RFQ), proposals (RFP), or an invitation for bids (IFB). This is a pre-solicitation notice indicating that a solicitation for a competitive acquisition for the award of one firm-fixed-price contract is intended to be issued via Contract Opportunities at SAM.gov.  The tentative solicitation issuance date is October 29, 2026.  The specifications and drawings will be included with the solicitation once issued. This announcement is for information and planning purposes only and is not to be construed as a commitment by the Government, implied or otherwise, to issue a solicitation or award a contract. Bids will be due not less than 30 days from the date the solicitation is issued.  The definitive bid due date and time will be stated in the solicitation and any associated amendments that may be issued. Contractors are responsible for checking this page for any update(s) to this notice. Pursuant to Revolutionary Federal Acquisition Regulation (FAR) Overhaul (RFO) 4.203-1 (b), firms must be System for Award Management (SAM) registered at the time their bid is submitted.  Bids from firms that have not registered or completed their online representations and certifications may be rejected.  The initial registration process in SAM may take several weeks.  Registration instructions may be obtained, and online registration may be accomplished, at www.SAM.gov","text":"NOTICE OF SOLICITATION NUMBER CHANGEThe John Day Powerhouse HVAC Upgrades acquisition, previously announced under presolicitation notice number W9127N26BA006, is now identified as W9127N27BA007 due to the fiscal-year transition. This presolicitation notice continues the announcement of the same acquisition under the new number; it does not represent a separate requirement. All subsequent notices and solicitation documents for this acquisition will reference solicitation number W9127N27BA007.The original presolicitation notice under W9127N26BA006 is available here: https://sam.gov/workspace/contract/opp/7efeefdf2b3c493d89f14b5ce67ff62a/view The U.S. Army Corps of Engineers (USACE) Portland District (NWP) has a requirement for HVAC upgrades at the John Day Dam (JDA) Powerhouse. JDA is approximately 109 miles east of Portland, Oregon, and 275 miles from Seattle, Washington. JDA spans two states, with Units 1 through 14 located in Sherman County, Oregon, and Units 15 and 16 in Klickitat County, Washington. Cybersecurity Maturity Model Certification (CMMC). This solicitation requires the contractor and/or subcontractor(s) information system to process, store, or transmit Federal Contract Information (FCI) or Controlled Unclassified Information (CUI), and requires the contractor and/or subcontractor(s) to comply with CMMC requirements. The CMMC level required by this solicitation is: CMMC Level 2 (Self). This CMMC level, or higher, is a condition of award. Prior to award, the apparent successful offeror must have a current CMMC status at Level 2 (Self), or higher, posted in SPRS for each relevant CMMC UID in order to remain eligible for award; failure to meet this requirement will render the offeror ineligible for contract award. CMMC requirements apply to prime contractors and subcontractors throughout the supply chain at all tiers that will process, store, or transmit any FCI or CUI on contractor information systems in the performance of this DoD contract or subcontract. Prime contractors shall comply and shall require subcontractors to comply with and to flow down CMMC requirements, such that compliance will be required throughout the supply chain at all tiers with the applicable CMMC level and assessment type for each subcontract as follows: If a subcontractor will only process, store, or transmit FCI (and not CUI) in performance of the subcontract, then a CMMC status of Level 1 (Self) is required for that subcontractor. If a subcontractor will process, store, or transmit CUI in performance of the subcontract, then a CMMC status of Level 2 (Self), or higher, is required for that subcontractor, and must be current in SPRS prior to subcontract award. Prime contractors are responsible for ensuring that all covered subcontractors obtain and maintain the appropriate CMMC level and assessment type for the information they will process, store, or transmit during performance. For this solicitation, contractors requesting access to documents containing FCI or CUI must have an active SAM registration and a current NIST SP 800 171 assessment with at least a Basic confidence level recorded in SPRS. Summary of Work: Work includes but is not limited to the following: 1. Complete replacement of the primary and installation of secondary chillers on two chilled water loops serving the majority of the Powerhouse galleries.2. Demolition and removal of the existing system and installation of four new chiller skid packages totaling approximately 600 tons of refrigeration capacity.3. New electrical feeds, chilled water pumps, piping, and air handler units, with selective reuse of existing components.4. Systems must be integrated into a new automated digital HVAC control system.5. Half of the new systems will be water-cooled; half will be converted to air-cooled. For the air-cooled units, roof-mounted air-cooled condensers will be installed, requiring roof penetrations, piping, and building modifications.6. HVAC upgrades include new intake and exhaust ducting to prevent smoke propagation through the building in the event of fire, and fire protection measures at all penetrations.7. HVAC and the building fire protection systems must be fully integrated, replacing all existing pneumatic controls with an integrated digital control system which is capable of functioning to selectively shut down the HVAC to isolate sectors in the event of a fire or smoke event.8. The work includes mechanical and controls provisions for free cooling using passive outside air during cold nights and modifications to existing intakes, louvers, and penetrations to support smoke ventilation.9. Localized HVAC units such as mini-splits will be installed for specific spaces, with new electrical supplies, piping, insulation, penetrations, and data reporting to the central HVAC control system.10. Work will be performed in an active, operational Powerhouse with 6000A, 13.8kV busbars and other heavy electrical equipment, including areas below headwater with nuisance water intrusion risks.11. Certain pumps must remain operational throughout construction, presenting noise and safety hazards that must be managed.12. The existing fire suppression system must remain active during construction and be recommissioned upon project completion.13. Work includes ductwork installation and protection of floor penetrations in close proximity to operational high-voltage electrical busbars, emphasizing strict delineation and safety control of work areas.14. New systems to be installed must not use refrigerants subject to future refrigerant phase-out schedules (no refrigerant subject to phase-out at any point in the future may be used). 15. Work includes extensive structural penetrations and modifications to support permanent equipment installation including piping, ductwork and new condensing systems.16. Asbestos abatement and lead mitigation may be required. The anticipated completion date for physical construction is 1,004 calendar days after receiving the Notice to Proceed. The solicitation will be issued as an Invitation for Bids (IFB). This acquisition will result in a single firm-fixed-price contract. The estimated magnitude of construction is between $25M and $100M. This procurement is unrestricted/full and open competition. The North American Industry Classification System (NAICS) code for this action is 238220; Plumbing, Heating, and Air-Conditioning Contractors with a small business size standard of $19M. One or more of the items under this acquisition is subject to the World Trade Organization Government Procurement Agreement and Free Trade Agreements. This synopsis is not a request for quotes (RFQ), proposals (RFP), or an invitation for bids (IFB). This is a pre-solicitation notice indicating that a solicitation for a competitive acquisition for the award of one firm-fixed-price contract is intended to be issued via Contract Opportunities at SAM.gov. The tentative solicitation issuance date is October 29, 2026. The specifications and drawings will be included with the solicitation once issued. This announcement is for information and planning purposes only and is not to be construed as a commitment by the Government, implied or otherwise, to issue a solicitation or award a contract. Bids will be due not less than 30 days from the date the solicitation is issued. The definitive bid due date and time will be stated in the solicitation and any associated amendments that may be issued. Contractors are responsible for checking this page for any update(s) to this notice. Pursuant to Revolutionary Federal Acquisition Regulation (FAR) Overhaul (RFO) 4.203-1 (b), firms must be System for Award Management (SAM) registered at the time their bid is submitted. Bids from firms that have not registered or completed their online representations and certifications may be rejected. The initial registration process in SAM may take several weeks. Registration instructions may be obtained, and online registration may be accomplished, at www.SAM.gov","origin":"detail"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"W9127N27BA007","place_of_performance":{"zip":"97050","street":"Near Rufus, Oregon"},"product_service_code":"Z2EZ"},{"dates":{"posted":"2026-10-29","posted_at":"2026-10-29T17:56:47.095Z","created_at":"2026-10-29T17:47:02.908Z","modified_at":"2026-10-29T17:56:47.102Z"},"links":{"sam":"https://sam.gov/workspace/contract/opp/61ff2d54f9114299950236018dce1902/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","agency":{"office":{"code":"W9127N","name":"W071 ENDIST PORTLAND"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"97204-3495","city":"PORTLAND","state":"OR","country":"USA"},"organization_id":"100255230","organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2027-10-29","archive_type":"auto_custom"},"history":[{"index":3,"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-29T22:09:26.126Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"ccd4de596e8c4f099e9719a242d03b04","solicitation_number":"W9127N27BA007","related_opportunity_id":"61ff2d54f9114299950236018dce1902"},{"index":2,"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-29T17:56:47.095Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"modify","opportunity_id":"61ff2d54f9114299950236018dce1902","solicitation_number":"W9127N27BA007","parent_opportunity_id":"1f35956f49d742f5af03485dbf5b3edd"},{"index":1,"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-29T17:29:16.166Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"submit","opportunity_id":"1f35956f49d742f5af03485dbf5b3edd","solicitation_number":"W9127N27BA007"}],"contacts":[{"name":"Aragon Liebzeit","role":"primary","email":"ARAGON.N.LIEBZEIT@USACE.ARMY.MIL","phone":"5038084610"},{"name":"Cory R. Pfenning","role":"secondary","email":"cory.r.pfenning@usace.army.mil","phone":"5038479540"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"61ff2d54f9114299950236018dce1902","lineage_id":"1f35956f49d742f5af03485dbf5b3edd","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-30T04:06:31.108400320Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"fee52df21fdaac6760f6309dc6a4b5e5-27\"","fetched_at":"2026-10-30T03:37:02.893800920Z","row_sha256":"832a2d911452cdfcff52493e58ac86d1acbbda1b9b4fb8cb43d76b5dd37a1f3f","last_modified":"2026-10-30T03:30:45Z"},"updated_at":"2026-10-30T04:06:31.108400320Z","first_seen_at":"2026-10-30T03:37:02.893800920Z"},"description":{"html":"<p>NOTICE OF SOLICITATION NUMBER CHANGE</p>\n\n<p>The John Day Powerhouse HVAC Upgrades acquisition, previously announced under presolicitation notice number W9127N26BA006, is now identified as W9127N27BA007 due to the fiscal-year transition. This presolicitation notice continues the announcement of the same acquisition under the new number; it does not represent a separate requirement. All subsequent notices and solicitation documents for this acquisition will reference solicitation number W9127N27BA007.</p>\n\n<p>The original presolicitation notice under W9127N26BA006 is available here: https://sam.gov/workspace/contract/opp/7efeefdf2b3c493d89f14b5ce67ff62a/view</p>\n\n<p>The U.S. Army Corps of Engineers (USACE) Portland District (NWP) has a requirement for HVAC upgrades at the John Day Dam (JDA) Powerhouse.</p>\n\n<p>JDA is approximately 109 miles east of Portland, Oregon, and 275 miles from Seattle, Washington. JDA spans two states, with Units 1 through 14 located in Sherman County, Oregon, and Units 15 and 16 in Klickitat County, Washington.</p>\n\n<p>Cybersecurity Maturity Model Certification (CMMC). This solicitation requires the contractor and/or subcontractor(s) information system to process, store, or transmit Federal Contract Information (FCI) or Controlled Unclassified Information (CUI), and requires the contractor and/or subcontractor(s) to comply with CMMC requirements. The CMMC level required by this solicitation is: CMMC Level 2 (Self). This CMMC level, or higher, is a condition of award. Prior to award, the apparent successful offeror must have a current CMMC status at Level 2 (Self), or higher, posted in SPRS for each relevant CMMC UID in order to remain eligible for award; failure to meet this requirement will render the offeror ineligible for contract award.</p>\n\n<p>CMMC requirements apply to prime contractors and subcontractors throughout the supply chain at all tiers that will process, store, or transmit any FCI or CUI on contractor information systems in the performance of this DoD contract or subcontract. Prime contractors shall comply and shall require subcontractors to comply with and to flow down CMMC requirements, such that compliance will be required throughout the supply chain at all tiers with the applicable CMMC level and assessment type for each subcontract as follows:</p>\n\n<p>If a subcontractor will only process, store, or transmit FCI (and not CUI) in performance of the subcontract, then a CMMC status of Level 1 (Self) is required for that subcontractor.</p>\n\n<p>If a subcontractor will process, store, or transmit CUI in performance of the subcontract, then a CMMC status of Level 2 (Self), or higher, is required for that subcontractor, and must be current in SPRS prior to subcontract award.</p>\n\n<p>Prime contractors are responsible for ensuring that all covered subcontractors obtain and maintain the appropriate CMMC level and assessment type for the information they will process, store, or transmit during performance.</p>\n\n<p>For this solicitation, contractors requesting access to documents containing FCI or CUI must have an active SAM registration and a current NIST SP 800 171 assessment with at least a Basic confidence level recorded in SPRS.</p>\n\n<p>Summary of Work: Work includes but is not limited to the following:</p>\n\n<p>1. Complete replacement of the primary and installation of secondary chillers on two chilled water loops serving the majority of the Powerhouse galleries.</p>\n\n<p>2. Demolition and removal of the existing system and installation of four new chiller skid packages totaling approximately 600 tons of refrigeration capacity.</p>\n\n<p>3. New electrical feeds, chilled water pumps, piping, and air handler units, with selective reuse of existing components.</p>\n\n<p>4. Systems must be integrated into a new automated digital HVAC control system.</p>\n\n<p>5. Half of the new systems will be water-cooled; half will be converted to air-cooled. For the air-cooled units, roof-mounted air-cooled condensers will be installed, requiring roof penetrations, piping, and building modifications.</p>\n\n<p>6. HVAC upgrades include new intake and exhaust ducting to prevent smoke propagation through the building in the event of fire, and fire protection measures at all penetrations.</p>\n\n<p>7. HVAC and the building fire protection systems must be fully integrated, replacing all existing pneumatic controls with an integrated digital control system which is capable of functioning to selectively shut down the HVAC to isolate sectors in the event of a fire or smoke event.</p>\n\n<p>8. The work includes mechanical and controls provisions for free cooling using passive outside air during cold nights and modifications to existing intakes, louvers, and penetrations to support smoke ventilation.</p>\n\n<p>9. Localized HVAC units such as mini-splits will be installed for specific spaces, with new electrical supplies, piping, insulation, penetrations, and data reporting to the central HVAC control system.</p>\n\n<p>10. Work will be performed in an active, operational Powerhouse with 6000A, 13.8kV busbars and other heavy electrical equipment, including areas below headwater with nuisance water intrusion risks.</p>\n\n<p>11. Certain pumps must remain operational throughout construction, presenting noise and safety hazards that must be managed.</p>\n\n<p>12. The existing fire suppression system must remain active during construction and be recommissioned upon project completion.</p>\n\n<p>13. Work includes ductwork installation and protection of floor penetrations in close proximity to operational high-voltage electrical busbars, emphasizing strict delineation and safety control of work areas.</p>\n\n<p>14. New systems to be installed must not use refrigerants subject to future refrigerant phase-out schedules (no refrigerant subject to phase-out at any point in the future may be used).</p>\n\n<p>15. Work includes extensive structural penetrations and modifications to support permanent equipment installation including piping, ductwork and new condensing systems.</p>\n\n<p>16. Asbestos abatement and lead mitigation may be required.</p>\n\n<p>The anticipated completion date for physical construction is 1,004 calendar days after receiving the Notice to Proceed.</p>\n\n<p>The solicitation will be issued as an Invitation for Bids (IFB). This acquisition will result in a single firm-fixed-price contract.</p>\n\n<p>The estimated magnitude of construction is between $25M and $100M.</p>\n\n<p>This procurement is unrestricted/full and open competition. The North American Industry Classification System (NAICS) code for this action is 238220; Plumbing, Heating, and Air-Conditioning Contractors with a small business size standard of $19M.</p>\n\n<p>One or more of the items under this acquisition is subject to the World Trade Organization Government Procurement Agreement and Free Trade Agreements.</p>\n\n<p>This synopsis is not a request for quotes (RFQ), proposals (RFP), or an invitation for bids (IFB). This is a pre-solicitation notice indicating that a solicitation for a competitive acquisition for the award of one firm-fixed-price contract is intended to be issued via Contract Opportunities at SAM.gov. The tentative solicitation issuance date is October 29, 2026. The specifications and drawings will be included with the solicitation once issued.</p>\n\n<p>This announcement is for information and planning purposes only and is not to be construed as a commitment by the Government, implied or otherwise, to issue a solicitation or award a contract.</p>\n\n<p>Bids will be due not less than 30 days from the date the solicitation is issued. The definitive bid due date and time will be stated in the solicitation and any associated amendments that may be issued.</p>\n\n<p>Contractors are responsible for checking this page for any update(s) to this notice.</p>\n\n<p>Pursuant to Revolutionary Federal Acquisition Regulation (FAR) Overhaul (RFO) 4.203-1 (b), firms must be System for Award Management (SAM) registered at the time their bid is submitted. Bids from firms that have not registered or completed their online representations and certifications may be rejected. The initial registration process in SAM may take several weeks. Registration instructions may be obtained, and online registration may be accomplished, at www.SAM.gov</p>","text":"NOTICE OF SOLICITATION NUMBER CHANGE\n\nThe John Day Powerhouse HVAC Upgrades acquisition, previously announced under presolicitation notice number W9127N26BA006, is now identified as W9127N27BA007 due to the fiscal-year transition. This presolicitation notice continues the announcement of the same acquisition under the new number; it does not represent a separate requirement. All subsequent notices and solicitation documents for this acquisition will reference solicitation number W9127N27BA007.\n\nThe original presolicitation notice under W9127N26BA006 is available here: https://sam.gov/workspace/contract/opp/7efeefdf2b3c493d89f14b5ce67ff62a/view\n\nThe U.S. Army Corps of Engineers (USACE) Portland District (NWP) has a requirement for HVAC upgrades at the John Day Dam (JDA) Powerhouse.\n\nJDA is approximately 109 miles east of Portland, Oregon, and 275 miles from Seattle, Washington. JDA spans two states, with Units 1 through 14 located in Sherman County, Oregon, and Units 15 and 16 in Klickitat County, Washington.\n\nCybersecurity Maturity Model Certification (CMMC). This solicitation requires the contractor and/or subcontractor(s) information system to process, store, or transmit Federal Contract Information (FCI) or Controlled Unclassified Information (CUI), and requires the contractor and/or subcontractor(s) to comply with CMMC requirements. The CMMC level required by this solicitation is: CMMC Level 2 (Self). This CMMC level, or higher, is a condition of award. Prior to award, the apparent successful offeror must have a current CMMC status at Level 2 (Self), or higher, posted in SPRS for each relevant CMMC UID in order to remain eligible for award; failure to meet this requirement will render the offeror ineligible for contract award.\n\nCMMC requirements apply to prime contractors and subcontractors throughout the supply chain at all tiers that will process, store, or transmit any FCI or CUI on contractor information systems in the performance of this DoD contract or subcontract. Prime contractors shall comply and shall require subcontractors to comply with and to flow down CMMC requirements, such that compliance will be required throughout the supply chain at all tiers with the applicable CMMC level and assessment type for each subcontract as follows:\n\nIf a subcontractor will only process, store, or transmit FCI (and not CUI) in performance of the subcontract, then a CMMC status of Level 1 (Self) is required for that subcontractor.\n\nIf a subcontractor will process, store, or transmit CUI in performance of the subcontract, then a CMMC status of Level 2 (Self), or higher, is required for that subcontractor, and must be current in SPRS prior to subcontract award.\n\nPrime contractors are responsible for ensuring that all covered subcontractors obtain and maintain the appropriate CMMC level and assessment type for the information they will process, store, or transmit during performance.\n\nFor this solicitation, contractors requesting access to documents containing FCI or CUI must have an active SAM registration and a current NIST SP 800 171 assessment with at least a Basic confidence level recorded in SPRS.\n\nSummary of Work: Work includes but is not limited to the following:\n\n1. Complete replacement of the primary and installation of secondary chillers on two chilled water loops serving the majority of the Powerhouse galleries.\n\n2. Demolition and removal of the existing system and installation of four new chiller skid packages totaling approximately 600 tons of refrigeration capacity.\n\n3. New electrical feeds, chilled water pumps, piping, and air handler units, with selective reuse of existing components.\n\n4. Systems must be integrated into a new automated digital HVAC control system.\n\n5. Half of the new systems will be water-cooled; half will be converted to air-cooled. For the air-cooled units, roof-mounted air-cooled condensers will be installed, requiring roof penetrations, piping, and building modifications.\n\n6. HVAC upgrades include new intake and exhaust ducting to prevent smoke propagation through the building in the event of fire, and fire protection measures at all penetrations.\n\n7. HVAC and the building fire protection systems must be fully integrated, replacing all existing pneumatic controls with an integrated digital control system which is capable of functioning to selectively shut down the HVAC to isolate sectors in the event of a fire or smoke event.\n\n8. The work includes mechanical and controls provisions for free cooling using passive outside air during cold nights and modifications to existing intakes, louvers, and penetrations to support smoke ventilation.\n\n9. Localized HVAC units such as mini-splits will be installed for specific spaces, with new electrical supplies, piping, insulation, penetrations, and data reporting to the central HVAC control system.\n\n10. Work will be performed in an active, operational Powerhouse with 6000A, 13.8kV busbars and other heavy electrical equipment, including areas below headwater with nuisance water intrusion risks.\n\n11. Certain pumps must remain operational throughout construction, presenting noise and safety hazards that must be managed.\n\n12. The existing fire suppression system must remain active during construction and be recommissioned upon project completion.\n\n13. Work includes ductwork installation and protection of floor penetrations in close proximity to operational high-voltage electrical busbars, emphasizing strict delineation and safety control of work areas.\n\n14. New systems to be installed must not use refrigerants subject to future refrigerant phase-out schedules (no refrigerant subject to phase-out at any point in the future may be used).\n\n15. Work includes extensive structural penetrations and modifications to support permanent equipment installation including piping, ductwork and new condensing systems.\n\n16. Asbestos abatement and lead mitigation may be required.\n\nThe anticipated completion date for physical construction is 1,004 calendar days after receiving the Notice to Proceed.\n\nThe solicitation will be issued as an Invitation for Bids (IFB). This acquisition will result in a single firm-fixed-price contract.\n\nThe estimated magnitude of construction is between $25M and $100M.\n\nThis procurement is unrestricted/full and open competition. The North American Industry Classification System (NAICS) code for this action is 238220; Plumbing, Heating, and Air-Conditioning Contractors with a small business size standard of $19M.\n\nOne or more of the items under this acquisition is subject to the World Trade Organization Government Procurement Agreement and Free Trade Agreements.\n\nThis synopsis is not a request for quotes (RFQ), proposals (RFP), or an invitation for bids (IFB). This is a pre-solicitation notice indicating that a solicitation for a competitive acquisition for the award of one firm-fixed-price contract is intended to be issued via Contract Opportunities at SAM.gov. The tentative solicitation issuance date is October 29, 2026. The specifications and drawings will be included with the solicitation once issued.\n\nThis announcement is for information and planning purposes only and is not to be construed as a commitment by the Government, implied or otherwise, to issue a solicitation or award a contract.\n\nBids will be due not less than 30 days from the date the solicitation is issued. The definitive bid due date and time will be stated in the solicitation and any associated amendments that may be issued.\n\nContractors are responsible for checking this page for any update(s) to this notice.\n\nPursuant to Revolutionary Federal Acquisition Regulation (FAR) Overhaul (RFO) 4.203-1 (b), firms must be System for Award Management (SAM) registered at the time their bid is submitted. Bids from firms that have not registered or completed their online representations and certifications may be rejected. The initial registration process in SAM may take several weeks. Registration instructions may be obtained, and online registration may be accomplished, at www.SAM.gov","origin":"detail"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"W9127N27BA007","place_of_performance":{"street":"Near Rufus, Oregon","country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"Z2EZ"},{"dates":{"posted":"2026-10-29","posted_at":"2026-10-29T22:16:14.444Z","created_at":"2026-10-29T22:14:11.672Z","modified_at":"2026-10-29T22:16:14.451Z","response_deadline":{"raw":"2026-12-28T14:00:00-08:00","utc":"2026-12-28T22:00:00Z","date":"2026-12-28","time":"14:00:00","timezone":"America/Los_Angeles","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/97e5c90d8a244e69a66a36401f3e5e4c/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","agency":{"office":{"code":"W9127N","name":"W071 ENDIST PORTLAND"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"97204-3495","city":"PORTLAND","state":"OR","country":"USA"},"organization_id":"100255230","organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2027-03-10","archive_type":"auto_custom"},"history":[{"index":3,"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-29T22:16:14.444Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"97e5c90d8a244e69a66a36401f3e5e4c","solicitation_number":"W9127N27BA007","parent_opportunity_id":"ccd4de596e8c4f099e9719a242d03b04","related_opportunity_id":"61ff2d54f9114299950236018dce1902"},{"index":2,"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-29T22:09:26.126Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"ccd4de596e8c4f099e9719a242d03b04","solicitation_number":"W9127N27BA007","related_opportunity_id":"61ff2d54f9114299950236018dce1902"},{"index":1,"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-29T17:56:47.095Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"modify","opportunity_id":"61ff2d54f9114299950236018dce1902","solicitation_number":"W9127N27BA007","parent_opportunity_id":"1f35956f49d742f5af03485dbf5b3edd"}],"contacts":[{"name":"Aragon Liebzeit","role":"primary","email":"ARAGON.N.LIEBZEIT@USACE.ARMY.MIL","phone":"5038084610"},{"name":"Cory Pfenning","role":"secondary","email":"Cory.R.Pfenning@usace.army.mil"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"97e5c90d8a244e69a66a36401f3e5e4c","lineage_id":"ccd4de596e8c4f099e9719a242d03b04","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-30T04:12:28.807347186Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"fee52df21fdaac6760f6309dc6a4b5e5-27\"","fetched_at":"2026-10-30T03:37:02.893800920Z","row_sha256":"3e1f7fda67aeaeefa9288ab6aeffc338efe9a841bab9fc6dca3808f2902ecda6","last_modified":"2026-10-30T03:30:45Z"},"updated_at":"2026-10-30T04:12:28.807347186Z","first_seen_at":"2026-10-30T03:37:02.893800920Z"},"description":{"html":"<p>10/29/2026: The solicitation with specifications and the drawings are attached.&nbsp; You must access the attachments via PIEE, see the links to the PIEE instructions below.&nbsp;&nbsp;</p>","text":"10/29/2026: The solicitation with specifications and the drawings are attached. You must access the attachments via PIEE, see the links to the PIEE instructions below.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"W9127N27BA007","place_of_performance":{"zip":"97050","street":"Near Rufus, Oregon"},"product_service_code":"Z2EZ"},{"dates":{"posted":"2026-10-29","posted_at":"2026-10-29T22:09:26.126Z","created_at":"2026-10-29T22:09:26.019Z","modified_at":"2026-10-29T22:16:14.444Z","response_deadline":{"raw":"2026-12-28T14:00:00-08:00","utc":"2026-12-28T22:00:00Z","date":"2026-12-28","time":"14:00:00","timezone":"America/Los_Angeles","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/ccd4de596e8c4f099e9719a242d03b04/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","agency":{"office":{"code":"W9127N","name":"W071 ENDIST PORTLAND"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"97204-3495","city":"PORTLAND","state":"OR","country":"USA"},"organization_id":"100255230","organization_type":"OFFICE"},"status":{"active":true,"latest":false,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2027-03-10","archive_type":"auto_custom"},"history":[{"index":3,"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-29T22:16:14.444Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"97e5c90d8a244e69a66a36401f3e5e4c","solicitation_number":"W9127N27BA007","parent_opportunity_id":"ccd4de596e8c4f099e9719a242d03b04","related_opportunity_id":"61ff2d54f9114299950236018dce1902"},{"index":2,"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-29T22:09:26.126Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"ccd4de596e8c4f099e9719a242d03b04","solicitation_number":"W9127N27BA007","related_opportunity_id":"61ff2d54f9114299950236018dce1902"},{"index":1,"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-29T17:56:47.095Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"modify","opportunity_id":"61ff2d54f9114299950236018dce1902","solicitation_number":"W9127N27BA007","parent_opportunity_id":"1f35956f49d742f5af03485dbf5b3edd"}],"contacts":[{"name":"Aragon Liebzeit","role":"primary","email":"ARAGON.N.LIEBZEIT@USACE.ARMY.MIL","phone":"5038084610"},{"name":"Cory Pfenning","role":"secondary","email":"Cory.R.Pfenning@usace.army.mil"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"ccd4de596e8c4f099e9719a242d03b04","lineage_id":"ccd4de596e8c4f099e9719a242d03b04","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-30T04:19:38.802087384Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"fee52df21fdaac6760f6309dc6a4b5e5-27\"","fetched_at":"2026-10-30T03:37:02.893800920Z","row_sha256":"5a81826395bf1cc42eeb18b34698512c81950e4de5fb6596bb679b44f59d2552","last_modified":"2026-10-30T03:30:45Z"},"updated_at":"2026-10-30T04:19:38.802087384Z","first_seen_at":"2026-10-30T03:37:02.893800920Z"},"description":{"html":"10/29/2026: The solicitation with specifications and the drawings are attached.","text":"10/29/2026: The solicitation with specifications and the drawings are attached.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"W9127N27BA007","place_of_performance":{"zip":"97050","street":"Near Rufus, Oregon"},"product_service_code":"Z2EZ"},{"dates":{"posted":"2026-10-30","posted_at":"2026-10-30T16:49:07.807Z","created_at":"2026-10-30T16:43:07.015Z","modified_at":"2026-10-30T16:49:07.813Z","response_deadline":{"raw":"2026-12-28T14:00:00-08:00","utc":"2026-12-28T22:00:00Z","date":"2026-12-28","time":"14:00:00","timezone":"America/Los_Angeles","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/89b27f77366f44c48abe9bbccef3b87d/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","agency":{"office":{"code":"W9127N","name":"W071 ENDIST PORTLAND"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"97204-3495","city":"PORTLAND","state":"OR","country":"USA"},"organization_id":"100255230","organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2027-03-10","archive_type":"auto_custom"},"history":[{"index":5,"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-30T16:49:07.807Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"89b27f77366f44c48abe9bbccef3b87d","solicitation_number":"W9127N27BA007","parent_opportunity_id":"ccd4de596e8c4f099e9719a242d03b04","related_opportunity_id":"61ff2d54f9114299950236018dce1902"},{"index":4,"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-30T16:17:33.105Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a26c4d09a32d41f48b7adb1113d5971a","solicitation_number":"W9127N27BA007","parent_opportunity_id":"ccd4de596e8c4f099e9719a242d03b04","related_opportunity_id":"61ff2d54f9114299950236018dce1902"},{"index":3,"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-29T22:16:14.444Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"97e5c90d8a244e69a66a36401f3e5e4c","solicitation_number":"W9127N27BA007","parent_opportunity_id":"ccd4de596e8c4f099e9719a242d03b04","related_opportunity_id":"61ff2d54f9114299950236018dce1902"},{"index":2,"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-29T22:09:26.126Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"ccd4de596e8c4f099e9719a242d03b04","solicitation_number":"W9127N27BA007","related_opportunity_id":"61ff2d54f9114299950236018dce1902"},{"index":1,"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-29T17:56:47.095Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"modify","opportunity_id":"61ff2d54f9114299950236018dce1902","solicitation_number":"W9127N27BA007","parent_opportunity_id":"1f35956f49d742f5af03485dbf5b3edd"}],"contacts":[{"name":"Aragon Liebzeit","role":"primary","email":"ARAGON.N.LIEBZEIT@USACE.ARMY.MIL","phone":"5038084610"},{"name":"Cory Pfenning","role":"secondary","email":"Cory.R.Pfenning@usace.army.mil"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"89b27f77366f44c48abe9bbccef3b87d","lineage_id":"ccd4de596e8c4f099e9719a242d03b04","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-31T04:11:46.395443777Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"9fcc40a8e585e779f98ab62c69344d0d-27\"","fetched_at":"2026-10-31T03:47:30.063427912Z","row_sha256":"979ebda5d6f4cbe439151628e9128281eeb178f67fbf478b3ba222a9a8df1007","last_modified":"2026-10-31T03:30:30Z"},"updated_at":"2026-10-31T04:11:46.395443777Z","first_seen_at":"2026-10-31T03:47:30.063427912Z"},"description":{"html":"<p>10/29/2026: The solicitation with specifications and the drawings are attached.</p>\n\n<p>10/30/2026: PIEE may label additional documents posted to this solicitation as amendments, even when those documents do not amend the solicitation. Formal solicitation amendments will be identified by amendment number on the SF 30 documents. Bidders should use that numbering sequence, not the PIEE system label, to distinguish formal solicitation amendments from other posted documents.</p>\n\n<p>The drawing package containing Controlled Unclassified Information (CUI) is now available for restricted access.</p>\n\n<p>In accordance with Executive Order 13556, Controlled Unclassified Information, DoD CUI policy, and the PIEE Solicitation Module, access to CUI attachments is restricted to authorized users. The PIEE Solicitation Module requires CUI attachments to be restricted by Commercial and Government Entity (CAGE) Code to protect controlled information.</p>\n\n<p>To request access to the CUI solicitation documents, interested offerors shall:</p>\n\n<p>1. Be registered in PIEE.</p>\n\n<p>2. Provide their CAGE Code and CMMC Unique Identifier (UID) number from SPRS/PIEE.</p>\n\n<p>3. Request access through the PIEE Solicitation Module (or by contacting the Contracting personnel).Once the CAGE Code is verified, access to the CUI attachments will be granted as appropriate.</p>","text":"10/29/2026: The solicitation with specifications and the drawings are attached.\n\n10/30/2026: PIEE may label additional documents posted to this solicitation as amendments, even when those documents do not amend the solicitation. Formal solicitation amendments will be identified by amendment number on the SF 30 documents. Bidders should use that numbering sequence, not the PIEE system label, to distinguish formal solicitation amendments from other posted documents.\n\nThe drawing package containing Controlled Unclassified Information (CUI) is now available for restricted access.\n\nIn accordance with Executive Order 13556, Controlled Unclassified Information, DoD CUI policy, and the PIEE Solicitation Module, access to CUI attachments is restricted to authorized users. The PIEE Solicitation Module requires CUI attachments to be restricted by Commercial and Government Entity (CAGE) Code to protect controlled information.\n\nTo request access to the CUI solicitation documents, interested offerors shall:\n\n1. Be registered in PIEE.\n\n2. Provide their CAGE Code and CMMC Unique Identifier (UID) number from SPRS/PIEE.\n\n3. Request access through the PIEE Solicitation Module (or by contacting the Contracting personnel).Once the CAGE Code is verified, access to the CUI attachments will be granted as appropriate.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"W9127N27BA007","place_of_performance":{"zip":"97050","street":"Near Rufus, Oregon"},"product_service_code":"Z2EZ"},{"dates":{"posted":"2026-10-30","posted_at":"2026-10-30T16:17:33.105Z","created_at":"2026-10-30T16:17:32.377Z","modified_at":"2026-10-30T16:49:07.807Z","response_deadline":{"raw":"2026-12-28T14:00:00-08:00","utc":"2026-12-28T22:00:00Z","date":"2026-12-28","time":"14:00:00","timezone":"America/Los_Angeles","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/a26c4d09a32d41f48b7adb1113d5971a/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","agency":{"office":{"code":"W9127N","name":"W071 ENDIST PORTLAND"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"97204-3495","city":"PORTLAND","state":"OR","country":"USA"},"organization_id":"100255230","organization_type":"OFFICE"},"status":{"active":true,"latest":false,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2027-03-10","archive_type":"auto_custom"},"history":[{"index":5,"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-30T16:49:07.807Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"89b27f77366f44c48abe9bbccef3b87d","solicitation_number":"W9127N27BA007","parent_opportunity_id":"ccd4de596e8c4f099e9719a242d03b04","related_opportunity_id":"61ff2d54f9114299950236018dce1902"},{"index":4,"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-30T16:17:33.105Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"a26c4d09a32d41f48b7adb1113d5971a","solicitation_number":"W9127N27BA007","parent_opportunity_id":"ccd4de596e8c4f099e9719a242d03b04","related_opportunity_id":"61ff2d54f9114299950236018dce1902"},{"index":3,"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-29T22:16:14.444Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"modify","opportunity_id":"97e5c90d8a244e69a66a36401f3e5e4c","solicitation_number":"W9127N27BA007","parent_opportunity_id":"ccd4de596e8c4f099e9719a242d03b04","related_opportunity_id":"61ff2d54f9114299950236018dce1902"},{"index":2,"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","action":"publish","latest":false,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-29T22:09:26.126Z","notice_type":{"code":"o","label":"Solicitation"},"request_type":"submit","opportunity_id":"ccd4de596e8c4f099e9719a242d03b04","solicitation_number":"W9127N27BA007","related_opportunity_id":"61ff2d54f9114299950236018dce1902"},{"index":1,"title":"John Day Dam Powerhouse HVAC Upgrades (W9127N27BA007)","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-29T17:56:47.095Z","notice_type":{"code":"p","label":"Presolicitation"},"request_type":"modify","opportunity_id":"61ff2d54f9114299950236018dce1902","solicitation_number":"W9127N27BA007","parent_opportunity_id":"1f35956f49d742f5af03485dbf5b3edd"}],"contacts":[{"name":"Aragon Liebzeit","role":"primary","email":"ARAGON.N.LIEBZEIT@USACE.ARMY.MIL","phone":"5038084610"},{"name":"Cory Pfenning","role":"secondary","email":"Cory.R.Pfenning@usace.army.mil"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"a26c4d09a32d41f48b7adb1113d5971a","lineage_id":"ccd4de596e8c4f099e9719a242d03b04","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-31T04:13:38.393159484Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"9fcc40a8e585e779f98ab62c69344d0d-27\"","fetched_at":"2026-10-31T03:47:30.063427912Z","row_sha256":"12b245607460e914282212e824fb13ead93b0d21114079f93c2d3bd41a7d22c9","last_modified":"2026-10-31T03:30:30Z"},"updated_at":"2026-10-31T04:13:38.393159484Z","first_seen_at":"2026-10-31T03:47:30.063427912Z"},"description":{"html":"10/29/2026: The solicitation with specifications and the drawings are attached. 10/30/2026:  PIEE may label additional documents posted to this solicitation as ���������������������������amendments,��������������������������� even when those documents do not amend the solicitation.Formal solicitation amendments will be identified by amendment number on the SF 30 documents. Bidders should use that numbering sequence���������������������������not the PIEE system label���������������������������to distinguish formal solicitation amendments from other posted documents. The drawing package containing Controlled Unclassified Information (CUI) is now available for restricted access. In accordance with Executive Order 13556, Controlled Unclassified Information, DoD CUI policy, and the PIEE Solicitation Module, access to CUI attachments is restricted to authorized users. The PIEE Solicitation Module requires CUI attachments to be restricted by Commercial and Government Entity (CAGE) Code to protect controlled information. To request access to the CUI solicitation documents, interested offerors shall:1.\tBe registered in PIEE.2.\tProvide their CAGE Code and CMMC Unique Identifier (UID) number from SPRS/PIEE.3.\tRequest access through the PIEE Solicitation Module (or by contacting the Contracting personnel).Once the CAGE Code is verified, access to the CUI attachments will be granted as appropriate.","text":"10/29/2026: The solicitation with specifications and the drawings are attached. 10/30/2026: PIEE may label additional documents posted to this solicitation as ���������������������������amendments,��������������������������� even when those documents do not amend the solicitation.Formal solicitation amendments will be identified by amendment number on the SF 30 documents. Bidders should use that numbering sequence���������������������������not the PIEE system label���������������������������to distinguish formal solicitation amendments from other posted documents. The drawing package containing Controlled Unclassified Information (CUI) is now available for restricted access. In accordance with Executive Order 13556, Controlled Unclassified Information, DoD CUI policy, and the PIEE Solicitation Module, access to CUI attachments is restricted to authorized users. The PIEE Solicitation Module requires CUI attachments to be restricted by Commercial and Government Entity (CAGE) Code to protect controlled information. To request access to the CUI solicitation documents, interested offerors shall:1. Be registered in PIEE.2. Provide their CAGE Code and CMMC Unique Identifier (UID) number from SPRS/PIEE.3. Request access through the PIEE Solicitation Module (or by contacting the Contracting personnel).Once the CAGE Code is verified, access to the CUI attachments will be granted as appropriate.","origin":"detail"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"W9127N27BA007","place_of_performance":{"zip":"97050","street":"Near Rufus, Oregon"},"product_service_code":"Z2EZ"}],"due_at":"2026-12-28T22:00:00Z","due_date":"2026-12-28","closes_at":"2026-12-28T22:00:00Z","awardable":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W9127N","office_name":"W071 ENDIST PORTLAND","state":"OR","county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","state_source":"sam_street","state_evidence":"NEAR RUFUS, OREGON","site_key":"john-day-dam-or","winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-10-31T03:50:03.904859Z","principal_notice_id":"a26c4d09a32d41f48b7adb1113d5971a","description":{"text":"10/29/2026: The solicitation with specifications and the drawings are attached. 10/30/2026: PIEE may label additional documents posted to this solicitation as ���������������������������amendments,��������������������������� even when those documents do not amend the solicitation.Formal solicitation amendments will be identified by amendment number on the SF 30 documents. Bidders should use that numbering sequence���������������������������not the PIEE system label���������������������������to distinguish formal solicitation amendments from other posted documents. The drawing package containing Controlled Unclassified Information (CUI) is now available for restricted access. In accordance with Executive Order 13556, Controlled Unclassified Information, DoD CUI policy, and the PIEE Solicitation Module, access to CUI attachments is restricted to authorized users. The PIEE Solicitation Module requires CUI attachments to be restricted by Commercial and Government Entity (CAGE) Code to protect controlled information. To request access to the CUI solicitation documents, interested offerors shall:1. Be registered in PIEE.2. Provide their CAGE Code and CMMC Unique Identifier (UID) number from SPRS/PIEE.3. Request access through the PIEE Solicitation Module (or by contacting the Contracting personnel).Once the CAGE Code is verified, access to the CUI attachments will be granted as appropriate.","html":"10/29/2026: The solicitation with specifications and the drawings are attached. 10/30/2026:  PIEE may label additional documents posted to this solicitation as ���������������������������amendments,��������������������������� even when those documents do not amend the solicitation.Formal solicitation amendments will be identified by amendment number on the SF 30 documents. Bidders should use that numbering sequence���������������������������not the PIEE system label���������������������������to distinguish formal solicitation amendments from other posted documents. The drawing package containing Controlled Unclassified Information (CUI) is now available for restricted access. In accordance with Executive Order 13556, Controlled Unclassified Information, DoD CUI policy, and the PIEE Solicitation Module, access to CUI attachments is restricted to authorized users. The PIEE Solicitation Module requires CUI attachments to be restricted by Commercial and Government Entity (CAGE) Code to protect controlled information. To request access to the CUI solicitation documents, interested offerors shall:1.\tBe registered in PIEE.2.\tProvide their CAGE Code and CMMC Unique Identifier (UID) number from SPRS/PIEE.3.\tRequest access through the PIEE Solicitation Module (or by contacting the Contracting personnel).Once the CAGE Code is verified, access to the CUI attachments will be granted as appropriate.","origin":"detail"},"contacts":[{"name":"Aragon Liebzeit","role":"primary","email":"ARAGON.N.LIEBZEIT@USACE.ARMY.MIL","phone":"5038084610"},{"name":"Cory Pfenning","role":"secondary","email":"Cory.R.Pfenning@usace.army.mil"}],"place_of_performance":{"zip":"97050","street":"Near Rufus, Oregon"},"office_address":{"zip":"97204-3495","city":"PORTLAND","state":"OR","country":"USA"},"naics_codes":["238220"],"award":null,"attachments":[{"resource_id":"3fbbc002fd774fd99888b9c093ec9c87","name":"3fbbc002fd774fd99888b9c093ec9c87","kind":"link","mime_type":null,"size_bytes":0,"posted_at":"2026-10-29T22:09:26.126Z","export_controlled":false,"sha256":null,"url":"https://toolbox-piee.eb.mil/","mirrored":false},{"resource_id":"f5b546e6dc72498e96d7b1894568e718","name":"f5b546e6dc72498e96d7b1894568e718","kind":"link","mime_type":null,"size_bytes":0,"posted_at":"2026-10-29T17:29:16.166Z","export_controlled":false,"sha256":null,"url":"https://toolbox-piee.eb.mil/","mirrored":false}],"awards":[],"related":[{"key":"W9127N27Q1CTI","latest_notice_id":"00802fa3a97c43a1b3d341e300245372","title":"Prosser Hatchery Sole Source Presolicitation Notice","solicitation_number":"W9127N27Q1CTI","notice_type":"p","first_type":"p","first_posted":"2026-10-21","last_posted":"2026-10-21","notices":1,"due_at":"2026-11-05T19:00:00Z","due_date":"2026-11-05","closes_at":"2026-11-05T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W9127N","office_name":"W071 ENDIST PORTLAND","naics":"112511","psc":"F022","set_aside":null,"state":"WA","county":"53005","county_name":"Benton County","city":"5356450","city_name":"Prosser","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-22T04:09:15.685315Z"},{"key":"W9127N27BA005","latest_notice_id":"b322a1af383c4a73b14068563c45e886","title":"W9127N27BA005 Foster Spillway Gate Nut Replacements and Re-Tensioning","solicitation_number":"W9127N27BA005","notice_type":"p","first_type":"p","first_posted":"2026-10-21","last_posted":"2026-10-21","notices":2,"due_at":"2026-11-05T20:00:00Z","due_date":"2026-11-05","closes_at":"2026-11-05T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W9127N","office_name":"W071 ENDIST PORTLAND","naics":"237990","psc":"Z2KA","set_aside":"SBA","state":"OR","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"sam_street","state_evidence":"FOSTER DAM, LINN COUNTY, OREGON","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-22T04:09:15.685315Z"},{"key":"W9127N27QA002","latest_notice_id":"82b567778b9f4fcfb490277b42998d30","title":"TDA Isolated Phase Bus and Duct Inspection","solicitation_number":"W9127N27QA002","notice_type":"o","first_type":"o","first_posted":"2026-09-29","last_posted":"2026-10-26","notices":4,"due_at":"2026-11-09T22:00:00Z","due_date":"2026-11-09","closes_at":"2026-11-09T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W9127N","office_name":"W071 ENDIST PORTLAND","naics":"541380","psc":"H361","set_aside":null,"state":"OR","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"sam_street","state_evidence":"THE DALLES DAM IN THE DALLES, OREGON. ACCESS TO THE DALLES DAM IS FROM I-84 EXIT 88","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-27T03:50:29.852134Z"},{"key":"W9127N27R2184","latest_notice_id":"fe69d91d0e5e48b5b612600f844c1085","title":"USCG Station at Cape Disappointment","solicitation_number":"W9127N27R2184","notice_type":"r","first_type":"r","first_posted":"2026-10-23","last_posted":"2026-10-27","notices":2,"due_at":"2026-11-15T23:00:00Z","due_date":"2026-11-15","closes_at":"2026-11-15T23:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W9127N","office_name":"W071 ENDIST PORTLAND","naics":null,"psc":null,"set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"unknown","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-28T04:01:09.175983Z"},{"key":"W9127N27BA009","latest_notice_id":"658d72fd7da64c1db8fe559b05226dfe","title":"JOHN DAY DAM NAVIGATION LOCK TAINTER VALVE (TV) REPAIRS TV3 AND TV4","solicitation_number":"W9127N27BA009","notice_type":"o","first_type":"o","first_posted":"2026-10-20","last_posted":"2026-10-22","notices":2,"due_at":"2026-11-19T19:00:00Z","due_date":"2026-11-19","closes_at":"2026-11-19T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W9127N","office_name":"W071 ENDIST PORTLAND","naics":"237990","psc":"Z2KA","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"multi_state","state_source":null,"state_evidence":"LOCATION AND ACCESS DETAILS. OREGON SIDE PHYSICAL ACCESS, NEAR RUFUS, OR 97050 ACCESSIBLE VIA I-84, EXIT 109. WASHINGTON SIDE (CLOSEST TOWN), GOLDENDALE, WA 986","site":"John Day Dam","site_key":"john-day-dam-or","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-23T03:46:32.604852Z"}],"similar_open":[{"key":"36C26027Q0102","latest_notice_id":"9829793eda3f46af9cbf1cb82292fb2d","title":"J041--White City B249 SE HVAC Repair","solicitation_number":"36C26027Q0102","notice_type":"p","first_type":"o","first_posted":"2026-10-28","last_posted":"2026-10-28","notices":3,"due_at":"2026-11-10T20:00:00Z","due_date":"2026-11-10","closes_at":"2026-11-10T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C260","office_name":"260-NETWORK CONTRACT OFFICE 20 (36C260)","naics":"238220","psc":"J041","set_aside":"SDVOSBC","state":"OR","county":"41029","county_name":"Jackson County","city":"4181450","city_name":"White City","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"},{"key":"FA446027Q0006","latest_notice_id":"0586b84315b646bdaeb78b8466d4c85c","title":"R-410A LEAK DETECTORS (Bldgs 750, 751 & 768)","solicitation_number":"FA446027Q0006","notice_type":"o","first_type":"o","first_posted":"2026-10-20","last_posted":"2026-10-27","notices":2,"due_at":"2026-11-02T15:00:00Z","due_date":"2026-11-02","closes_at":"2026-11-02T15:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA4460","office_name":"FA4460 19 CONS PKA","naics":"238220","psc":"4120","set_aside":"SBA","state":"AR","county":"05119","county_name":"Pulaski County","city":null,"city_name":null,"country":"USA","place_scope":"nationwide","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-28T04:01:09.175983Z"},{"key":"12444326Q0039","latest_notice_id":"5e09aa0ed1c94cdd815e8a23adfd3ad5","title":"Green Mountain National Forest Storage tank cleaning and inspection at Hapgood Pond","solicitation_number":"12444326Q0039","notice_type":"o","first_type":"o","first_posted":"2026-07-30","last_posted":"2026-10-27","notices":7,"due_at":"2026-11-02T17:00:00Z","due_date":"2026-11-02","closes_at":"2026-11-02T17:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-012","dept_name":"AGRICULTURE, DEPARTMENT OF","sub_key":"s-12C2","sub_name":"FOREST SERVICE","office_key":"o-121681","office_name":"GREEN MOUNTAIN NATIONAL FOREST","naics":"238220","psc":"M1NE","set_aside":"SBA","state":"VT","county":"50003","county_name":"Bennington County","city":"5000355000","city_name":"Peru","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":"Green Mountain National Forest","site_key":"green-mountain-national-forest-vt","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-28T04:01:09.175983Z"}],"similar_open_total":43}