{"canonical":"https://abierto.us/opportunities/w911sg24q0074","key":"W911SG24Q0074","url":"https://abierto.us/opportunities/w911sg24q0074","title":"Ventilated Enclosure/Paint Booth","solicitation_number":"W911SG24Q0074","notice_type":"k","open":false,"response_deadline":"2024-07-08T22:00:00Z","first_posted":"2024-06-14","last_posted":"2024-06-28","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE ARMY","office":"W6QM MICC-FT BLISS","naics":"333413","psc":"4460","set_aside":"SBA","place_state":"TX","place_county":"48141","place_county_name":"El Paso County","place_city":"4826664","place_city_name":"Fort Bliss","winner":"TECH SERVICE SOLUTIONS LLC","award_amount":null,"publications":[{"notice_id":"4fc805c6d24041ad8f832d4f566bf606","title":"Ventilated Enclosure/Paint Booth","solicitation_number":"W911SG24Q0074","notice_type":"k","base_type":"k","posted":"2024-06-14","posted_at":null,"due_at":"2024-06-26T16:00:00Z","due_date":"2024-06-26","cancelled":null,"archived":null,"archive_date":"2024-07-11","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/4fc805c6d24041ad8f832d4f566bf606/view","enriched":false,"history":[]},{"notice_id":"29be62cacaeb4da4a4c4df53493b7523","title":"Ventilated Enclosure/Paint Booth","solicitation_number":"W911SG24Q0074","notice_type":"k","base_type":"k","posted":"2024-06-20","posted_at":null,"due_at":"2024-06-26T16:00:00Z","due_date":"2024-06-26","cancelled":null,"archived":null,"archive_date":"2024-07-11","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/29be62cacaeb4da4a4c4df53493b7523/view","enriched":false,"history":[]},{"notice_id":"8b28d7513a0c45238e91b3f3c4d8a24f","title":"Ventilated Enclosure/Paint Booth","solicitation_number":"W911SG24Q0074","notice_type":"k","base_type":"k","posted":"2024-06-25","posted_at":null,"due_at":"2024-06-27T22:00:00Z","due_date":"2024-06-27","cancelled":null,"archived":null,"archive_date":"2024-07-12","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/8b28d7513a0c45238e91b3f3c4d8a24f/view","enriched":false,"history":[]},{"notice_id":"673aa89120534057969ec94bda7bd642","title":"Ventilated Enclosure/Paint Booth","solicitation_number":"W911SG24Q0074","notice_type":"k","base_type":"k","posted":"2024-06-27","posted_at":null,"due_at":"2024-06-28T22:00:00Z","due_date":"2024-06-28","cancelled":null,"archived":null,"archive_date":"2024-07-13","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/673aa89120534057969ec94bda7bd642/view","enriched":false,"history":[]},{"notice_id":"be2d5a9891274f63a56c2a4a6075a5d2","title":"Ventilated Enclosure/Paint Booth","solicitation_number":"W911SG24Q0074","notice_type":"k","base_type":"k","posted":"2024-06-28","posted_at":null,"due_at":"2024-07-08T22:00:00Z","due_date":"2024-07-08","cancelled":null,"archived":null,"archive_date":"2024-07-23","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/be2d5a9891274f63a56c2a4a6075a5d2/view","enriched":false,"history":[]}],"latest_notice_id":"be2d5a9891274f63a56c2a4a6075a5d2","first_type":"k","notices":[{"dates":{"posted":"2024-06-14","response_deadline":{"raw":"2024-06-26T10:00:00-06:00","utc":"2024-06-26T16:00:00Z","date":"2024-06-26","time":"10:00:00","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/4fc805c6d24041ad8f832d4f566bf606/view"},"naics":{"codes":["333413"],"primary":"333413"},"title":"Ventilated Enclosure/Paint Booth","agency":{"office":{"code":"W911SG","name":"W6QM MICC-FT BLISS"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"79916-6812","city":"FORT BLISS","state":"TX","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-07-11","archive_type":"auto15"},"contacts":[{"name":"Joseph Flores","role":"primary","email":"joseph.a.flores.civ@army.mil","phone":"9155687870"},{"name":"Major Alan Lambert","role":"secondary","email":"alan.r.lambert4.mil@army.mil"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"4fc805c6d24041ad8f832d4f566bf606","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"c052c026baa0d72b545bdcb74a79836df539373d6f1daf6bc6cc7cf2499a4e3c","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Product Description AIR FILTRATION SYSTEM REQUIREMENTS (VENTILATED ENCLOSURE/PAINT BOOTH) Many ventilation systems exist and could potentially be used to control the Cr(VI) hazard during aviationmaintenance processes.Selection should be done in collaboration with Industrial Hygiene and Safety professionals to ensure the ventilation system meets minimum design criteria. Defense Centers for Public Health-Aberdeen recommends the following minimum design criteria: • American Conference of Governmental Hygienists (ACGIH)® Industrial Ventilation Manual Figure VS-75-01 Large Paint Booth: Minimum cross-sectional velocity of 75 feet per minute (fpm) for a large deep booth with a cross-sectional area greater than 150 square feet (ft2). Airless electrostatic and high velocity low pressure spray paint operations require an air velocity of only 60 fpm. • ACGIH® Industrial Ventilation Manual Figure VS-80-01 Abrasive Blasting Room: Cross-sectional velocity range of 60-100 fpm. • American National Standards Institute/American Society of Safety Professionals (ANSI/ASSP) Z9.4-201 I (R2021): Requires a cross-sectional velocity of 80 fpm. Exhaust System - 18,000 Cubic Feet per Minute or higher to achieve ACGIH recommended TLVs - Must verify accurate testing and sampling data that system will provide clean air below the ACGIH TLVs of 0.0002mg/m3 - Exhaust air to be “RETURNED TO BUILDING” as per ANSI Z9.7 (NO ADDITIONAL VENTILATION REQUIREMENTS TO EXISTING STRUCTURES) - Multi-stage Particulate filtration exceeds the National Emission Standards for Hazardous Air Pollutants (NESHAP) 319 Enclosure - Enclosure must be Cross Draft Negative - Material NFPA 701 Compliant - Recommend size: 10’H X 18’W X 45”L (based on hangar size and unit requirements) Fire Suppression - Dry Chemical to protect both the enclosure and exhaust - Pre-engineered meeting NFPA 17 Standard for Dry Chemical extinguishing Replacement Filters - 18 Month Supply Lighting - Eight (8) Lights: 10,000 lumens per light Warranty - 5-year warranty","origin":"extract"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"W911SG24Q0074","place_of_performance":{"zip":"79916","city":{"name":"Fort Bliss"},"state":{"code":"TX"},"country":{"code":"USA"}},"product_service_code":"4460"},{"dates":{"posted":"2024-06-20","response_deadline":{"raw":"2024-06-26T10:00:00-06:00","utc":"2024-06-26T16:00:00Z","date":"2024-06-26","time":"10:00:00","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/29be62cacaeb4da4a4c4df53493b7523/view"},"naics":{"codes":["333413"],"primary":"333413"},"title":"Ventilated Enclosure/Paint Booth","agency":{"office":{"code":"W911SG","name":"W6QM MICC-FT BLISS"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"79916-6812","city":"FORT BLISS","state":"TX","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-07-11","archive_type":"auto15"},"contacts":[{"name":"Joseph Flores","role":"primary","email":"joseph.a.flores.civ@army.mil","phone":"9155687870"},{"name":"Major Alan Lambert","role":"secondary","email":"alan.r.lambert4.mil@army.mil"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"29be62cacaeb4da4a4c4df53493b7523","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"70ffe04d10a316daa5bd45c455c87c66a8ef97409ecb581bde57119cb9efd026","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Product Description AIR FILTRATION SYSTEM REQUIREMENTS (VENTILATED ENCLOSURE/PAINT BOOTH) Many ventilation systems exist and could potentially be used to control the Cr(VI) hazard during aviationmaintenance processes.Selection should be done in collaboration with Industrial Hygiene and Safety professionals to ensure the ventilation system meets minimum design criteria. Defense Centers for Public Health-Aberdeen recommends the following minimum design criteria: • American Conference of Governmental Hygienists (ACGIH)® Industrial Ventilation Manual Figure VS-75-01 Large Paint Booth: Minimum cross-sectional velocity of 75 feet per minute (fpm) for a large deep booth with a cross-sectional area greater than 150 square feet (ft2). Airless electrostatic and high velocity low pressure spray paint operations require an air velocity of only 60 fpm. • ACGIH® Industrial Ventilation Manual Figure VS-80-01 Abrasive Blasting Room: Cross-sectional velocity range of 60-100 fpm. • American National Standards Institute/American Society of Safety Professionals (ANSI/ASSP) Z9.4-201 I (R2021): Requires a cross-sectional velocity of 80 fpm. Exhaust System - 18,000 Cubic Feet per Minute or higher to achieve ACGIH recommended TLVs - Must verify accurate testing and sampling data that system will provide clean air below the ACGIH TLVs of 0.0002mg/m3 - Exhaust air to be “RETURNED TO BUILDING” as per ANSI Z9.7 (NO ADDITIONAL VENTILATION REQUIREMENTS TO EXISTING STRUCTURES) - Multi-stage Particulate filtration exceeds the National Emission Standards for Hazardous Air Pollutants (NESHAP) 319 Enclosure - Enclosure must be Cross Draft Negative - Material NFPA 701 Compliant - Recommend size: 10’H X 18’W X 45”L (based on hangar size and unit requirements) Fire Suppression - Dry Chemical to protect both the enclosure and exhaust - Pre-engineered meeting NFPA 17 Standard for Dry Chemical extinguishing Replacement Filters - 18 Month Supply Lighting - Eight (8) Lights: 10,000 lumens per light Warranty - 5-year warranty","origin":"extract"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"W911SG24Q0074","place_of_performance":{"zip":"79916","city":{"name":"Fort Bliss"},"state":{"code":"TX"},"country":{"code":"USA"}},"product_service_code":"4460"},{"dates":{"posted":"2024-06-25","response_deadline":{"raw":"2024-06-27T16:00:00-06:00","utc":"2024-06-27T22:00:00Z","date":"2024-06-27","time":"16:00:00","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/8b28d7513a0c45238e91b3f3c4d8a24f/view"},"naics":{"codes":["333413"],"primary":"333413"},"title":"Ventilated Enclosure/Paint Booth","agency":{"office":{"code":"W911SG","name":"W6QM MICC-FT BLISS"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"79916-6812","city":"FORT BLISS","state":"TX","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-07-12","archive_type":"auto15"},"contacts":[{"name":"Joseph Flores","role":"primary","email":"joseph.a.flores.civ@army.mil","phone":"9155687870"},{"name":"Major Alan Lambert","role":"secondary","email":"alan.r.lambert4.mil@army.mil"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"8b28d7513a0c45238e91b3f3c4d8a24f","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"180f4e0b568289362cb12279cbc08a5fa15cd7951a97d5b64705cf9fddcee048","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Product Description AIR FILTRATION SYSTEM REQUIREMENTS (VENTILATED ENCLOSURE/PAINT BOOTH) Many ventilation systems exist and could potentially be used to control the Cr(VI) hazard during aviationmaintenance processes.Selection should be done in collaboration with Industrial Hygiene and Safety professionals to ensure the ventilation system meets minimum design criteria. Defense Centers for Public Health-Aberdeen recommends the following minimum design criteria: • American Conference of Governmental Hygienists (ACGIH)® Industrial Ventilation Manual Figure VS-75-01 Large Paint Booth: Minimum cross-sectional velocity of 75 feet per minute (fpm) for a large deep booth with a cross-sectional area greater than 150 square feet (ft2). Airless electrostatic and high velocity low pressure spray paint operations require an air velocity of only 60 fpm. • ACGIH® Industrial Ventilation Manual Figure VS-80-01 Abrasive Blasting Room: Cross-sectional velocity range of 60-100 fpm. • American National Standards Institute/American Society of Safety Professionals (ANSI/ASSP) Z9.4-201 I (R2021): Requires a cross-sectional velocity of 80 fpm. Exhaust System - 18,000 Cubic Feet per Minute or higher to achieve ACGIH recommended TLVs - Must verify accurate testing and sampling data that system will provide clean air below the ACGIH TLVs of 0.0002mg/m3 - Exhaust air to be “RETURNED TO BUILDING” as per ANSI Z9.7 (NO ADDITIONAL VENTILATION REQUIREMENTS TO EXISTING STRUCTURES) - Multi-stage Particulate filtration exceeds the National Emission Standards for Hazardous Air Pollutants (NESHAP) 319 Enclosure - Enclosure must be Cross Draft Negative - Material NFPA 701 Compliant - Recommend size: 10’H X 18’W X 45”L (based on hangar size and unit requirements) Fire Suppression - Dry Chemical to protect both the enclosure and exhaust - Pre-engineered meeting NFPA 17 Standard for Dry Chemical extinguishing Replacement Filters - 18 Month Supply Lighting - Eight (8) Lights: 10,000 lumens per light Warranty - 5-year warranty","origin":"extract"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"W911SG24Q0074","place_of_performance":{"zip":"79916","city":{"name":"Fort Bliss"},"state":{"code":"TX"},"country":{"code":"USA"}},"product_service_code":"4460"},{"dates":{"posted":"2024-06-27","response_deadline":{"raw":"2024-06-28T16:00:00-06:00","utc":"2024-06-28T22:00:00Z","date":"2024-06-28","time":"16:00:00","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/673aa89120534057969ec94bda7bd642/view"},"naics":{"codes":["333413"],"primary":"333413"},"title":"Ventilated Enclosure/Paint Booth","agency":{"office":{"code":"W911SG","name":"W6QM MICC-FT BLISS"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"79916-6812","city":"FORT BLISS","state":"TX","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-07-13","archive_type":"auto15"},"contacts":[{"name":"Joseph Flores","role":"primary","email":"joseph.a.flores.civ@army.mil","phone":"9155687870"},{"name":"Major Alan Lambert","role":"secondary","email":"alan.r.lambert4.mil@army.mil"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"673aa89120534057969ec94bda7bd642","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"aecd568d81604a70d529e45afffd4fc019a343dcce396c15ff388b4d41100273","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Product Description AIR FILTRATION SYSTEM REQUIREMENTS (VENTILATED ENCLOSURE/PAINT BOOTH) Many ventilation systems exist and could potentially be used to control the Cr(VI) hazard during aviation maintenance processes. Selection should be done in collaboration with Industrial Hygiene and Safety professionals to ensure the ventilation system meets minimum design criteria. Defense Centers for Public Health-Aberdeen recommends the following minimum design criteria: • American Conference of Governmental Hygienists (ACGIH)® Industrial Ventilation Manual Figure VS-75-01 Large Paint Booth: Minimum cross-sectional velocity of 100 feet per minute (fpm) for a large deep booth with a cross-sectional area greater than 150 square feet (ft2). Airless electrostatic and high velocity low pressure spray paint operations require an air velocity of 100 fpm. • ACGIH® Industrial Ventilation Manual Figure VS-80-01 Abrasive Blasting Room: Cross-sectional minimum velocity of 100 fpm. • American National Standards Institute/American Society of Safety Professionals (ANSI/ASSP) Z9.4-201 I (R2021): Requires a cross-sectional velocity of 100 fpm. Exhaust System - 18,000 Cubic Feet per Minute or higher to achieve ACGIH recommended TLVs - Must verify accurate testing and sampling data that system will provide clean air below the ACGIH TLVs of 0.0002mg/m3 - Multi-stage Particulate filtration exceeds the National Emission Standards for Hazardous Air Pollutants (NESHAP) 319 to ensure Soldiers working outside of the enclosure are not exposed to hexavalent chromium levels in excess of .0002mg/m3. Enclosure - Enclosure must be Cross Draft Negative - Material NFPA 701 Compliant - Recommend size: 10’H X 18’W X 45”L (based on hangar size and unit requirements) Fire Suppression - Dry Chemical to protect both the enclosure and exhaust - Pre-engineered meeting NFPA 17 Standard for Dry Chemical extinguishing Replacement Filters - 18 Month Supply Lighting - Eight (8) Lights: 10,000 lumens per light Warranty - 5-year warranty","origin":"extract"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"W911SG24Q0074","place_of_performance":{"zip":"79916","city":{"name":"Fort Bliss"},"state":{"code":"TX"},"country":{"code":"USA"}},"product_service_code":"4460"},{"dates":{"posted":"2024-06-28","response_deadline":{"raw":"2024-07-08T16:00:00-06:00","utc":"2024-07-08T22:00:00Z","date":"2024-07-08","time":"16:00:00","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/be2d5a9891274f63a56c2a4a6075a5d2/view"},"naics":{"codes":["333413"],"primary":"333413"},"title":"Ventilated Enclosure/Paint Booth","agency":{"office":{"code":"W911SG","name":"W6QM MICC-FT BLISS"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"79916-6812","city":"FORT BLISS","state":"TX","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-07-23","archive_type":"auto15"},"contacts":[{"name":"Joseph Flores","role":"primary","email":"joseph.a.flores.civ@army.mil","phone":"9155687870"},{"name":"Major Alan Lambert","role":"secondary","email":"alan.r.lambert4.mil@army.mil"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"be2d5a9891274f63a56c2a4a6075a5d2","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"c4cd9d6a2a833c8ec72d0c850be9c881ebb1f70db0d27f2d912928de5e04115a","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Product Description AIR FILTRATION SYSTEM REQUIREMENTS (VENTILATED ENCLOSURE/PAINT BOOTH) Many ventilation systems exist and could potentially be used to control the Cr(VI) hazard during aviation maintenance processes. Selection should be done in collaboration with Industrial Hygiene and Safety professionals to ensure the ventilation system meets minimum design criteria. Defense Centers for Public Health-Aberdeen recommends the following minimum design criteria: • American Conference of Governmental Hygienists (ACGIH)® Industrial Ventilation Manual Figure VS-75-01 Large Paint Booth: Minimum cross-sectional velocity of 100 feet per minute (fpm) for a large deep booth with a cross-sectional area greater than 150 square feet (ft2). Airless electrostatic and high velocity low pressure spray paint operations require an air velocity of 100 fpm. • ACGIH® Industrial Ventilation Manual Figure VS-80-01 Abrasive Blasting Room: Cross-sectional minimum velocity of 100 fpm. • American National Standards Institute/American Society of Safety Professionals (ANSI/ASSP) Z9.4-201 I (R2021): Requires a cross-sectional velocity of 100 fpm. Exhaust System - 18,000 Cubic Feet per Minute or higher to achieve ACGIH recommended TLVs - Must verify accurate testing and sampling data that system will provide clean air below the ACGIH TLVs of 0.0002mg/m3 - Multi-stage Particulate filtration exceeds the National Emission Standards for Hazardous Air Pollutants (NESHAP) 319 to ensure Soldiers working outside of the enclosure are not exposed to hexavalent chromium levels in excess of .0002mg/m3. Enclosure - Enclosure must be Cross Draft Negative - Material NFPA 701 Compliant - Recommend size: 10’H X 18’W X 45”L (based on hangar size and unit requirements) Fire Suppression - Dry Chemical to protect both the enclosure and exhaust - Pre-engineered meeting NFPA 17 Standard for Dry Chemical extinguishing Replacement Filters - 18 Month Supply Lighting - Eight (8) Lights: 10,000 lumens per light Warranty - 5-year warranty","origin":"extract"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"W911SG24Q0074","place_of_performance":{"zip":"79916","city":{"name":"Fort Bliss"},"state":{"code":"TX"},"country":{"code":"USA"}},"product_service_code":"4460"}],"due_at":"2024-07-08T22:00:00Z","due_date":"2024-07-08","closes_at":"2024-07-08T22:00:00Z","awardable":false,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911SG","office_name":"W6QM MICC-FT BLISS","state":"TX","county":"48141","county_name":"El Paso County","city":"4826664","city_name":"Fort Bliss","country":"USA","winner_key":"UKZDZ3TPMLU1","amount":null,"linked_awards":10,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z","principal_notice_id":"be2d5a9891274f63a56c2a4a6075a5d2","description":{"text":"Product Description AIR FILTRATION SYSTEM REQUIREMENTS (VENTILATED ENCLOSURE/PAINT BOOTH) Many ventilation systems exist and could potentially be used to control the Cr(VI) hazard during aviation maintenance processes. Selection should be done in collaboration with Industrial Hygiene and Safety professionals to ensure the ventilation system meets minimum design criteria. Defense Centers for Public Health-Aberdeen recommends the following minimum design criteria: • American Conference of Governmental Hygienists (ACGIH)® Industrial Ventilation Manual Figure VS-75-01 Large Paint Booth: Minimum cross-sectional velocity of 100 feet per minute (fpm) for a large deep booth with a cross-sectional area greater than 150 square feet (ft2). Airless electrostatic and high velocity low pressure spray paint operations require an air velocity of 100 fpm. • ACGIH® Industrial Ventilation Manual Figure VS-80-01 Abrasive Blasting Room: Cross-sectional minimum velocity of 100 fpm. • American National Standards Institute/American Society of Safety Professionals (ANSI/ASSP) Z9.4-201 I (R2021): Requires a cross-sectional velocity of 100 fpm. Exhaust System - 18,000 Cubic Feet per Minute or higher to achieve ACGIH recommended TLVs - Must verify accurate testing and sampling data that system will provide clean air below the ACGIH TLVs of 0.0002mg/m3 - Multi-stage Particulate filtration exceeds the National Emission Standards for Hazardous Air Pollutants (NESHAP) 319 to ensure Soldiers working outside of the enclosure are not exposed to hexavalent chromium levels in excess of .0002mg/m3. Enclosure - Enclosure must be Cross Draft Negative - Material NFPA 701 Compliant - Recommend size: 10’H X 18’W X 45”L (based on hangar size and unit requirements) Fire Suppression - Dry Chemical to protect both the enclosure and exhaust - Pre-engineered meeting NFPA 17 Standard for Dry Chemical extinguishing Replacement Filters - 18 Month Supply Lighting - Eight (8) Lights: 10,000 lumens per light Warranty - 5-year warranty","html":null,"origin":"extract"},"contacts":[{"name":"Joseph Flores","role":"primary","email":"joseph.a.flores.civ@army.mil","phone":"9155687870"},{"name":"Major Alan Lambert","role":"secondary","email":"alan.r.lambert4.mil@army.mil"}],"place_of_performance":{"zip":"79916","city":{"name":"Fort Bliss"},"state":{"code":"TX"},"country":{"code":"USA"}},"office_address":{"zip":"79916-6812","city":"FORT BLISS","state":"TX","country":"USA"},"naics_codes":["333413"],"award":null,"attachments":[],"awards":[{"award_key":"CONT_AWD_W911SG24P0094_9700_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_W911SG24P0094_9700_-NONE-_-NONE-/","piid":"W911SG24P0094","parent_piid":null,"award_type":"PURCHASE ORDER","vendor_key":"UKZDZ3TPMLU1","recipient_name":"TECH SERVICE SOLUTIONS LLC","recipient_uei":"UKZDZ3TPMLU1","recipient_cage":"91QC4","recipient_city":"PHOENIX","recipient_state":"AZ","sub_name":"Department of the Army","office_name":"W6QM MICC-FT BLISS","office_key":"o-W911SG","first_action_date":"2024-07-22","last_action_date":"2024-08-02","actions":2,"obligated":"0","current_total_value":"0","potential_total_value":"0","naics":"333413","psc":"4460","extent_competed":"COMPETED UNDER SAP","set_aside":"SMALL BUSINESS SET ASIDE - TOTAL","offers_received":6,"description":"VENTIALTED PAINT SYSTEM","method":"solicitation","confidence":"high","evidence":["solicitation number W911SG24Q0074 equals the FPDS solicitation identifier","same awarding office W911SG"],"opportunity_key":null,"opportunity_title":null},{"award_key":"CONT_AWD_W911SG24P0099_9700_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_W911SG24P0099_9700_-NONE-_-NONE-/","piid":"W911SG24P0099","parent_piid":null,"award_type":"PURCHASE ORDER","vendor_key":"SKN6ZCV2L174","recipient_name":"ARHAB LLC","recipient_uei":"SKN6ZCV2L174","recipient_cage":"9UVS7","recipient_city":"STRATFORD","recipient_state":"CT","sub_name":"Department of the Army","office_name":"W6QM MICC-FT BLISS","office_key":"o-W911SG","first_action_date":"2024-08-09","last_action_date":"2024-08-09","actions":1,"obligated":"181765.00","current_total_value":"181765.00","potential_total_value":"181765.00","naics":"333413","psc":"4460","extent_competed":"COMPETED UNDER SAP","set_aside":"SMALL BUSINESS SET ASIDE - TOTAL","offers_received":6,"description":"VENTILATED PAINT SYSTEM","method":"solicitation","confidence":"high","evidence":["solicitation number W911SG24Q0074 equals the FPDS solicitation identifier","same awarding office W911SG"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"W911SG26BA017","latest_notice_id":"bc12638778bc420cb39460eab8eb0e10","title":"WSMR BRIDGE REPAIR RR7B0003","solicitation_number":"W911SG26BA017","notice_type":"o","first_type":"p","first_posted":"2026-09-08","last_posted":"2026-09-09","notices":2,"due_at":"2026-09-18T16:00:00Z","due_date":"2026-09-18","closes_at":"2026-09-18T16:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911SG","office_name":"W6QM MICC-FT BLISS","naics":"237310","psc":"Z2LB","set_aside":"SBA","state":"NM","county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"W911SG26BA014","latest_notice_id":"f7ed34c9d153422b8c2245338e49e533","title":"TDAC-WSMR Installation of Motion Sensors","solicitation_number":"W911SG26BA014","notice_type":"o","first_type":"p","first_posted":"2026-07-29","last_posted":"2026-09-14","notices":3,"due_at":"2026-09-18T20:00:00Z","due_date":"2026-09-18","closes_at":"2026-09-18T20:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911SG","office_name":"W6QM MICC-FT BLISS","naics":"238210","psc":"Z2AA","set_aside":"SBA","state":"NM","county":"35013","county_name":"Doña Ana County","city":null,"city_name":null,"country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"W911SG26QA064","latest_notice_id":"8bc6a6e0358a46e58ad572ad24785fa4","title":"Fort Bliss Kitchen Equipment: Purchase and Installation","solicitation_number":"W911SG26QA064","notice_type":"k","first_type":"k","first_posted":"2026-09-01","last_posted":"2026-09-14","notices":5,"due_at":"2026-09-21T15:00:00Z","due_date":"2026-09-21","closes_at":"2026-09-21T15:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911SG","office_name":"W6QM MICC-FT BLISS","naics":"333241","psc":"3605","set_aside":"SBA","state":"TX","county":"48141","county_name":"El Paso County","city":"4826664","city_name":"Fort Bliss","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"W911SG26QA068","latest_notice_id":"b86c3fbcc6944ca7a8fd6cfcf0e5ecf1","title":"DC Battery Replacement/Disposal","solicitation_number":"W911SG26QA068","notice_type":"k","first_type":"k","first_posted":"2026-09-16","last_posted":"2026-09-16","notices":3,"due_at":"2026-09-23T15:00:00Z","due_date":"2026-09-23","closes_at":"2026-09-23T15:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911SG","office_name":"W6QM MICC-FT BLISS","naics":"238210","psc":"J061","set_aside":"SBA","state":"NM","county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-17T06:28:38.602097Z"},{"key":"W911SG27BA002","latest_notice_id":"bfa92a554f0f43cca0777769fc50b2d6","title":"New Fort Bliss Paving IDIQ Contract","solicitation_number":"W911SG27BA002","notice_type":"o","first_type":"p","first_posted":"2026-07-13","last_posted":"2026-09-03","notices":5,"due_at":"2026-09-24T15:00:00Z","due_date":"2026-09-24","closes_at":"2026-09-24T15:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911SG","office_name":"W6QM MICC-FT BLISS","naics":"237310","psc":"Z2LB","set_aside":"8A","state":"TX","county":"48141","county_name":"El Paso County","city":"4826664","city_name":"Fort Bliss","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"}]}