# 150 HP ELECTRIC MOTOR

Canonical: https://abierto.us/opportunities/w911s226u4210

- Solicitation number: W911S226U4210
- Notice type: Combined synopsis and solicitation
- Status: Closed. Deadline was August 31, 2026 at 11:00 AM EDT
- Department: Department of the Army
- Agency: Department of the Army
- Contracting office: W6QM Micc-Ft Drum (W911S2)
- NAICS: 335312 Motor and Generator Manufacturing
- Product or service code: 6105 Motors, Electrical
- Set-aside: Total small business set-aside
- First posted: August 21, 2026
- Last posted: August 21, 2026
- SAM.gov: https://sam.gov/workspace/contract/opp/1938c639bc5449d88fef45766fbc8469/view

## Description

Item: Electric motor Brand Name: Toshiba Part Number: B1504YLF4USH Salient Characteristics: Manufacturer Toshiba Model / Part Number B1504YLF4USHFrame Size NEMA 445T Enclosure Type Totally Enclosed Fan Cooled (TEFC) / Totally Enclosed Explosion Proof (TEXP) Mounting Configuration Footed Mount / Rigid Base Construction Material Rugged Cast Iron (Frame, End Brackets, Conduit Box, and Fan Cover) Physical Dimensions Height: ~26 in, Length: ~48.4 in, Width: ~22.4 in Estimated Net Weight ~2,087 lbs. . Electrical and Performance Characteristics These performance metrics ensure compatibility with tactical or base electrical systems . Salient Characteristic Required Specification Output Power 150 HP (Horsepower) Synchronous Speed 1800RPM (Revolutions Per Minute) Operating Voltage Dual-rated 230 / 460 VAC Phase /Frequency 3-Phase, 60 Hz Service Factor 1.15 Nominal Full Load Efficiency 95.8%(NEMA Premium Efficiency compliant) Full Load Amperage 352 A (at 230V) / 176 A (at460V) Duty Cycle Continuous .. Environmental and Safety Ratings Due to the critical nature of Department of War missions and operations in hazardous areas, the motor must carry verified explosion-proof ratings to handle volatile elements. Salient Characteristic Required Specification Hazardous Environment Certifications Must be certified for: Class I, Division 1, Group D (Flammable Gases) Class II, Division 1, Groups E, F and G(Combustible Dusts) Temperature Code Rating T3C (160C maximum exterior surface temperature under fault conditions) Standards Compliance Exceeds UL and CSA safety standards for hazardous environments1 each

## Attachments

- [923508b2e3d440898a931f3ce1871bcd](https://dodprocurementtoolbox.com/)

## Publications

- August 21, 2026: Combined synopsis and solicitation, due August 31, 2026 at 11:00 AM EDT. Notice 1938c639bc5449d88fef45766fbc8469. https://sam.gov/workspace/contract/opp/1938c639bc5449d88fef45766fbc8469/view

## Points of contact

- David Fortune, david.c.fortune.civ@army.mil, 9184206445

---
Source: SAM.gov Contract Opportunities bulk extract. Confirm deadlines on SAM.gov before responding. Cite https://abierto.us/opportunities/w911s226u4210.
