{"canonical":"https://abierto.us/opportunities/w911s226u4017","key":"W911S226U4017","url":"https://abierto.us/opportunities/w911s226u4017","title":"SAFETY SHOWER","solicitation_number":"W911S226U4017","notice_type":"k","open":false,"response_deadline":"2026-08-18T14:00:00Z","first_posted":"2026-08-10","last_posted":"2026-08-10","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE ARMY","office":"W6QM MICC-FT DRUM","naics":"332913","psc":"4240","set_aside":"SBA","place_state":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"d5979f2abb544b6981b4dd5a2a2139bc","title":"SAFETY SHOWER","solicitation_number":"W911S226U4017","notice_type":"k","base_type":"k","posted":"2026-08-10","posted_at":null,"due_at":"2026-08-18T14:00:00Z","due_date":"2026-08-18","cancelled":null,"archived":null,"archive_date":"2027-08-10","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/d5979f2abb544b6981b4dd5a2a2139bc/view","enriched":false,"history":[]}],"latest_notice_id":"d5979f2abb544b6981b4dd5a2a2139bc","first_type":"k","notices":[{"dates":{"posted":"2026-08-10","response_deadline":{"raw":"2026-08-18T09:00:00-05:00","utc":"2026-08-18T14:00:00Z","date":"2026-08-18","time":"09:00:00","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/d5979f2abb544b6981b4dd5a2a2139bc/view"},"naics":{"codes":["332913"],"primary":"332913"},"title":"SAFETY SHOWER","agency":{"office":{"code":"W911S2","name":"W6QM MICC-FT DRUM"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"13602-5220","city":"FORT DRUM","state":"NY","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"archive_date":"2027-08-10","archive_type":"auto_custom"},"contacts":[{"name":"David Fortune","role":"primary","email":"david.c.fortune.civ@army.mil","phone":"9184206445"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"d5979f2abb544b6981b4dd5a2a2139bc","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"3f59209463433eba6899e195a597c64d-29\"","fetched_at":"2026-09-16T07:50:12.777658Z","row_sha256":"f26c875f74770bf3edbfbb4f126440545fce65c09aca346f89bb90b1340f519f","last_modified":"2026-09-16T03:30:52Z"},"updated_at":"2026-09-16T07:50:12.777658Z","first_seen_at":"2026-09-16T00:55:28.845070Z"},"description":{"text":"ATS EcoTower C1D2/26 ? Pneumatic, Skid-Mounted Safety Shower and Eyewash Station (or Equal) Primary Purpose: To provide rapid, compliant, and self-contained emergency decontamination (shower and eye/face wash) in remote locations or harsh environments lacking a potable water source, specifically within hazardous areas. ________________________________________ ???? Core System and Compliance Standards ? Safety Compliance: Must be fully compliant with ANSI/ISEAZ358.1 (2014) standards for emergency eyewash and shower equipment, ensuring continuous flow capabilities ? Electrical Hazard Classification: Must be certified for Class I, Division 2 (C1D2) hazardous locations to prevent ignition risks in environments where flammable gases or vapors may be present________________________________________ ? Water Capacity and Thermal Regulation ? Fluid Capacity: Must include an integrated, heavy-duty insulated water storage tank with a minimum capacity of 325 gallons to guarantee a minimum of 15minutes of continuous tepid water flow. ? Tepid Water Delivery: Must feature an integrated, electrical immersion heating system (minimum 1,200 Watts) to actively maintain stored water temperatures above the ANSI-mandated minimum of 60?F (15.6?C) in freezing or cold-weather conditions ? Freeze Protection: Must utilize a self-regulating heat trace system to protect plumbing and supply lines from freezing down to an ambient operating temperature threshold of 0?F (-17.8?C) ________________________________________???? Pneumatic Operation and Mechanical Specifications ? Pumping System: Must utilize a pneumatically driven transfer pump (rather than electric) to deliver pressurized water to the showerhead and eyewash . This ensures complete spark-free operation in C1D2 zones and allows the unit to safely function during electrical outages via pneumatic backup ?Pneumatic Air Source Input: Must support a shop air compressor supply or specialized nitrogen tank supply with an operational pressure range of 60 to 120 PSI (recommended regulator set to 80 PSI) ? Flow Rates: ? Shower: Must deliver a regulated flow rate of at least 20 GPM (76 LPM) ? Eyewash: Must deliver a regulated flow rate of at least 0.4 GPM(1.5 LPM) with an integrated protective dust/debris cover________________________________________ ???? Structural and Mounting Specifications ? Skid-Mount Design: Must be built on a heavy-duty, corrosion-resistant, powder-coated steel skid frame designed for rapid deployment, positioning by forklift/crane, and high-wind structural stability. ? Footprint and Portability: Must maintain a compact, space-saving footprint suitable for deployment in tight industrial spaces, remote airfields, or forward operating environments ? Material Durability: All critical external piping and the showerhead assembly must be constructed from durable stainless steel or equivalent corrosion-resistant materials. ? Controls and Activation: Must feature a highly visible, easy-to-reach mechanical pull-handle mechanism for instant, hands-free activation of the shower ________________________________________ ? Power Requirements ?Electrical Input: Must operate on standard, readily available utility or generator power:120V, single-phase, 60Hz, 20-Amp draw (typically utilizing a NEMA 5-20 plug configuration)","origin":"extract"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"W911S226U4017","place_of_performance":{"zip":"74501","street":"McAlester Army Ammunition Plant; 1 C-Tree Road, Building 6; McAlester, OK 74501"},"product_service_code":"4240"}],"due_at":"2026-08-18T14:00:00Z","due_date":"2026-08-18","closes_at":"2026-08-18T14:00:00Z","awardable":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","state":null,"country":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T07:31:38.954589Z","principal_notice_id":"d5979f2abb544b6981b4dd5a2a2139bc","description":{"text":"ATS EcoTower C1D2/26 ? Pneumatic, Skid-Mounted Safety Shower and Eyewash Station (or Equal) Primary Purpose: To provide rapid, compliant, and self-contained emergency decontamination (shower and eye/face wash) in remote locations or harsh environments lacking a potable water source, specifically within hazardous areas. ________________________________________ ???? Core System and Compliance Standards ? Safety Compliance: Must be fully compliant with ANSI/ISEAZ358.1 (2014) standards for emergency eyewash and shower equipment, ensuring continuous flow capabilities ? Electrical Hazard Classification: Must be certified for Class I, Division 2 (C1D2) hazardous locations to prevent ignition risks in environments where flammable gases or vapors may be present________________________________________ ? Water Capacity and Thermal Regulation ? Fluid Capacity: Must include an integrated, heavy-duty insulated water storage tank with a minimum capacity of 325 gallons to guarantee a minimum of 15minutes of continuous tepid water flow. ? Tepid Water Delivery: Must feature an integrated, electrical immersion heating system (minimum 1,200 Watts) to actively maintain stored water temperatures above the ANSI-mandated minimum of 60?F (15.6?C) in freezing or cold-weather conditions ? Freeze Protection: Must utilize a self-regulating heat trace system to protect plumbing and supply lines from freezing down to an ambient operating temperature threshold of 0?F (-17.8?C) ________________________________________???? Pneumatic Operation and Mechanical Specifications ? Pumping System: Must utilize a pneumatically driven transfer pump (rather than electric) to deliver pressurized water to the showerhead and eyewash . This ensures complete spark-free operation in C1D2 zones and allows the unit to safely function during electrical outages via pneumatic backup ?Pneumatic Air Source Input: Must support a shop air compressor supply or specialized nitrogen tank supply with an operational pressure range of 60 to 120 PSI (recommended regulator set to 80 PSI) ? Flow Rates: ? Shower: Must deliver a regulated flow rate of at least 20 GPM (76 LPM) ? Eyewash: Must deliver a regulated flow rate of at least 0.4 GPM(1.5 LPM) with an integrated protective dust/debris cover________________________________________ ???? Structural and Mounting Specifications ? Skid-Mount Design: Must be built on a heavy-duty, corrosion-resistant, powder-coated steel skid frame designed for rapid deployment, positioning by forklift/crane, and high-wind structural stability. ? Footprint and Portability: Must maintain a compact, space-saving footprint suitable for deployment in tight industrial spaces, remote airfields, or forward operating environments ? Material Durability: All critical external piping and the showerhead assembly must be constructed from durable stainless steel or equivalent corrosion-resistant materials. ? Controls and Activation: Must feature a highly visible, easy-to-reach mechanical pull-handle mechanism for instant, hands-free activation of the shower ________________________________________ ? Power Requirements ?Electrical Input: Must operate on standard, readily available utility or generator power:120V, single-phase, 60Hz, 20-Amp draw (typically utilizing a NEMA 5-20 plug configuration)","html":null,"origin":"extract"},"contacts":[{"name":"David Fortune","role":"primary","email":"david.c.fortune.civ@army.mil","phone":"9184206445"}],"place_of_performance":{"zip":"74501","street":"McAlester Army Ammunition Plant; 1 C-Tree Road, Building 6; McAlester, OK 74501"},"office_address":{"zip":"13602-5220","city":"FORT DRUM","state":"NY","country":"USA"},"naics_codes":["332913"],"award":null,"attachments":[],"awards":[],"related":[{"key":"W911S226U4429","latest_notice_id":"057d5d78295240f9a4ae00da8c9319c6","title":"Firearm Training Sensor","solicitation_number":"W911S226U4429","notice_type":"k","first_type":"k","first_posted":"2026-09-10","last_posted":"2026-09-10","notices":1,"due_at":"2026-09-16T17:00:00Z","due_date":"2026-09-16","closes_at":"2026-09-16T17:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"332994","psc":"6920","set_aside":"SBA","state":null,"country":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T07:31:38.954589Z"},{"key":"W911S226U4390","latest_notice_id":"c569b842531246d19e3d425758c78c8a","title":"8JR Air Rifles","solicitation_number":"W911S226U4390","notice_type":"k","first_type":"k","first_posted":"2026-09-02","last_posted":"2026-09-15","notices":5,"due_at":"2026-09-16T17:00:00Z","due_date":"2026-09-16","closes_at":"2026-09-16T17:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"339999","psc":"6910","set_aside":"SBA","state":null,"country":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T07:50:43.959643Z"},{"key":"W911S226U3820","latest_notice_id":"b56082af73e14ac497f384c9459b4b98","title":"Labbot","solicitation_number":"W911S226U3820","notice_type":"k","first_type":"k","first_posted":"2026-07-24","last_posted":"2026-09-11","notices":3,"due_at":"2026-09-16T17:00:00Z","due_date":"2026-09-16","closes_at":"2026-09-16T17:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"334516","psc":"6630","set_aside":"SBA","state":null,"country":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T07:31:38.954589Z"},{"key":"W911S226U4398","latest_notice_id":"454a4127f6d749f78c50277280c9ed3d","title":"Portable Generator","solicitation_number":"W911S226U4398","notice_type":"k","first_type":"k","first_posted":"2026-09-10","last_posted":"2026-09-10","notices":1,"due_at":"2026-09-16T17:00:00Z","due_date":"2026-09-16","closes_at":"2026-09-16T17:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"335312","psc":"6115","set_aside":"SBA","state":null,"country":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T07:31:38.954589Z"},{"key":"W911S226U4441","latest_notice_id":"327b622bb90a4228a27c13038219627c","title":"Portable Radios and Charging Stations","solicitation_number":"W911S226U4441","notice_type":"k","first_type":"k","first_posted":"2026-09-09","last_posted":"2026-09-10","notices":2,"due_at":"2026-09-16T17:00:00Z","due_date":"2026-09-16","closes_at":"2026-09-16T17:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"334220","psc":"5820","set_aside":"SBA","state":null,"country":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T07:31:38.954589Z"}]}