# Trailer

Canonical: https://abierto.us/opportunities/w911s226u3970

- Solicitation number: W911S226U3970
- Notice type: Combined synopsis and solicitation
- Status: Closed. Deadline was August 12, 2026 at 12:45 PM EDT
- Department: Department of the Army
- Agency: Department of the Army
- Contracting office: W6QM Micc-Ft Drum (W911S2)
- NAICS: 336212 Truck Trailer Manufacturing
- Product or service code: 4210 Fire Fighting Equipment
- First posted: August 6, 2026
- Last posted: August 7, 2026
- SAM.gov: https://sam.gov/workspace/contract/opp/3c3937a6f62c48e9abe0536dd59ab6ad/view

## Description

The purpose of this amendment is to attach the graphics requirements and provide additional specifications for the trailer height, UPS system, EIA equipment rack, roof-mounted antennas, and exterior monitor.

**Procurement:** 42 ft. Mobile Command Center (MCC) TrailerSCOPE:The contractor shall design, manufacture, and deliver one (1) custom-built, heavy-duty Mobile Command Center (MCC) trailer. The MCC will serve as a multi-agency incident command post for FES, Police, Guards, and Garrison Command Staff during large-scale emergencies.PLATFORM AND EXTERIOR SPECIFICATIONS:Dimensions: Minimum 42 ft. Length x 8 ft.

Width (nominal).Hitch Type: Heavy-duty 5th-Wheel Kingpin (or Gooseneck) configuration, matched to a GVWR appropriate for the fully loaded trailer.Slide-Outs: Minimum of two (2) flat-floor slide-outs to maximize interior operational space.Leveling System: Heavy-duty automatic hydraulic leveling system (minimum 4-point).Awning: One (1) heavy-duty motorized awning on the curbside, positioned to cover the exterior monitor, with an automatic wind-retraction sensor.Graphics: Full custom exterior vinyl wrap with Department of War / Garrison FES branding and reflective striping (graphics package to be approved by the Government post-award).Lighting:Minimum of two (2) high-lumen LED scene lights per side (8 total).Full emergency warning light package (Red/Blue LEDs) conforming to emergency vehicle standards.POWER AND CLIMATE CONTROL:Generator: Minimum 20kW Onan (or equivalent) commercial-grade diesel generator with remote interior start and custom fabricated fuel cell.Climate Control: Three (3) 15,000 BTU roof-mounted HVAC units with heat pumps/strips, ducted for even air distribution, capable of maintaining 70?F interior temperature in extreme high-heat environments (110?F+ ambient).Shore Power: Heavy-duty shore power connection (e.g., 50A or 100A as appropriate for load) with a minimum 50-foot heavy-duty male-end umbilical cord.Power Protection: Rack-mounted Uninterruptible Power Supply (UPS) sized to support the communications and server rack to prevent drop-outs during power transition.INTERIOR LAYOUT AND FINISHES:Zones: Trailer must be divided into a Main Operations Area and a secure Conference Area, separated by a sound-deadening door.

No lavatory or kitchenette to be included.Workstations: Six (6) total dedicated workstations.

One (1) workstation must be customized specifically for a Dispatch Console.Desks/Cabinetry: Heavy-duty, commercial-grade desks and overhead/under-desk aluminum or high-pressure laminate storage cabinetry for each workstation.Whiteboards: Two (2) large magnetic dry-erase whiteboards (one in the main area, one in the conference area).COMMUNICATIONS AND TECHNOLOGY:Server Rack: Minimum one (1) full-height or half-height 19 inch EIA equipment rack structurally mounted and cooled.Radio Prep: Pre-wired for Government Furnished Equipment (GFE) Motorola and Harris radios.

Must include roof-mounted antenna bases and coaxial cable runs to all six (6) workstations.Network/Data: Trailer must be pre-wired with CAT6 ethernet drops at all workstations, routed back to the server rack, ready for Government-installed FirstNet routing equipment.Monitors:One (1) large touchscreen interactive monitor mounted in the Conference Area.

**Interior Height:** Thetrailer must have a minimum interior height of 80 inches (6 ft. 8 inches). This ensuresadequate head clearance for personnel and allows for the installation of overhead LEDlighting, wire runways, and ducted HVAC systems without restricting movement.

**ExteriorHeight:** The overall exterior height of the trailer must not exceed 12 feet 6 inches (150inches) in its stowed/transport configuration. This measurement must include all roofmountedequipment, such as low-profile HVAC units, stowed light towers, and antennas, toguarantee clearance under standard highway bridges and overpasses.

**Runtime:** The UPSsystem must be capable of powering all critical communication and network routingequipment for a minimum of 30 minutes under a full operational load. This runtime isintended to act as a power bridge, allowing safe power transition between Shore Power andthe onboard generator, or enabling a graceful shutdown of critical systems during a powerfailure.

**Wattage/Capacity:** The syFor tstem must support a minimum continuous load of3,000VA / 2,700 Watts. The vendor must supply a double-conversion online UPS to ensuresensitive radio and IT equipment receive clean, regulated power, isolated from voltagespikes or generator sags.

**Rack Units (RU):** The equipment rack must provide a minimumof 16U of usable rack space to accommodate patch panels, network switches, routers, theUPS, and radio chassis, while leaving room for future expansion.

**Rack Depth:** The rackmust have a minimum usable depth of 25 inches (front-to-back rail depth) to safely housedeeper server-style equipment and the UPS chassis. The rack must also feature front andrear adjustable mounting rails and robust rear cable-management brackets designed towithstand transit vibration.

**Antenna Bases:** The trailer must be equipped with a minimumof 6 roof-mounted antenna bases (standard threaded NMO mounts).

**Installation Detail:** Thebases must be spaced at least 3 feet apart to prevent RF interference. They must be prewiredto the internal EIA equipment rack using low-loss coaxial cable (such as LMR-400or equivalent) and must include solid copper grounding planes integrated into the roofstructure.

**Monitor Size:** The exterior display must be a 49-inch to 55-inch high-brightness,daylight-readable (minimum 1000 nits), commercial-grade outdoor monitor. Mounting andHousing: The monitor must be permanently housed in a recessed, weatherproof, andlockable exterior compartment rather than a removable mount. The compartment mustfeature gas-shock-assisted doors, integrated LED compartment lighting, and a heavy-dutyarticulating pull-out mount that allows the monitor to be angled for group briefings. Allexterior graphics require Government approval prior to application.

## Publications

- August 6, 2026: Combined synopsis and solicitation, due August 12, 2026 at 12:45 PM EDT. Notice 4f660f3041c4496b992e36cce6048eb6. https://sam.gov/workspace/contract/opp/4f660f3041c4496b992e36cce6048eb6/view
- August 7, 2026: Combined synopsis and solicitation, due August 12, 2026 at 12:45 PM EDT. Notice 3c3937a6f62c48e9abe0536dd59ab6ad. https://sam.gov/workspace/contract/opp/3c3937a6f62c48e9abe0536dd59ab6ad/view

## Points of contact

- Andre Bishop, andre.r.bishop.civ@army.mil, 580-714-9525

---
Source: SAM.gov Contract Opportunities bulk extract. Confirm deadlines on SAM.gov before responding. Cite https://abierto.us/opportunities/w911s226u3970.