{"canonical":"https://abierto.us/opportunities/w911s226u3545","key":"W911S226U3545","url":"https://abierto.us/opportunities/w911s226u3545","title":"Battery","solicitation_number":"W911S226U3545","notice_type":"k","open":false,"response_deadline":"2026-07-08T06:00:00Z","first_posted":"2026-06-30","last_posted":"2026-06-30","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE ARMY","office":"W6QM MICC-FT DRUM","naics":"335910","psc":"6160","set_aside":"SBA","place_state":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"99a1b78dbc254cc8989fc62127b3837f","title":"Battery","solicitation_number":"W911S226U3545","notice_type":"k","base_type":"k","posted":"2026-06-30","posted_at":null,"due_at":"2026-07-08T06:00:00Z","due_date":"2026-07-08","cancelled":null,"archived":null,"archive_date":"2027-06-30","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/99a1b78dbc254cc8989fc62127b3837f/view","enriched":false,"history":[]}],"latest_notice_id":"99a1b78dbc254cc8989fc62127b3837f","first_type":"k","notices":[{"dates":{"posted":"2026-06-30","response_deadline":{"raw":"2026-07-08T00:00:00-06:00","utc":"2026-07-08T06:00:00Z","date":"2026-07-08","time":"00:00:00","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/99a1b78dbc254cc8989fc62127b3837f/view"},"naics":{"codes":["335910"],"primary":"335910"},"title":"Battery","agency":{"office":{"code":"W911S2","name":"W6QM MICC-FT DRUM"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"13602-5220","city":"FORT DRUM","state":"NY","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"archive_date":"2027-06-30","archive_type":"auto_custom"},"contacts":[{"name":"Traci Sablan","role":"primary","email":"traci.l.sablan.civ@army.mil","phone":"4358332713"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"99a1b78dbc254cc8989fc62127b3837f","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"3f59209463433eba6899e195a597c64d-29\"","fetched_at":"2026-09-16T07:50:12.777658Z","row_sha256":"72f9f8a00c7d9365fdecbcbb67f3512f3defedb9c6fcf2fd1f6eeeaac3f3a594","last_modified":"2026-09-16T03:30:52Z"},"updated_at":"2026-09-16T07:50:12.777658Z","first_seen_at":"2026-09-16T00:55:28.845070Z"},"description":{"text":"Item 1 - 48 Volt Forklift Batteries, model 24-85-15 Salient Characteristics: 1. General Requirements - Battery must be fully compatible with Hyster E40XN electric forklift specifications.; Meet battery model 24-85-15 specifications; Battery must be manufactured in the United States.; Battery must meet or exceed OEM performance standards for voltage, capacity, and physical dimensions.; Battery must be suitable for Class I electric forklift applications.; 2. Electrical Performance Specifications -System Voltage: 48V, Mandatory for OEM controller compatibility.; Cell Count: 24 LEAD-Acid Cells (Exact), Standard 2V per cell configuration.; Plate Configuration: 15 plates per cell (Equivalent), Ensures proper energy density and heat dissipation.; Rated Capacity (6-hour): 590 Ah Minimum - 610 Ah Maximum, Mates the standard 85 Ah per positive plate requirement. Must support full shift operation under normal warehouse conditions.; Cycle life Yield: 1,500 cycles at 80% DoD Minimum, Baseline durability for DoW operational tempo.; Charging Compatibility: Must be compatible with standard 48V industrial chargers; vendor must specify charger requirements if unique.; 3. Dimensional Tolerances and Form Factor - Tray Length: 34.50 in. ? 35.50 in.; Tray Width: 26.50 in. ? 27.25 in.; Tray Height (No Cover): 22.00 in. ? 22.75 in.; Total Height Clearance: Must not exceed 23.50in. Maximum, Accounts for optional battery rollers in the E40XN.; 4. Weight and Counterweight Requirements - Weight: 1,850 lbs. (839 kg) Minimum ? 2,500 lbs. (1,134kg) Maximum.; Target Service Weight: 2,300 lbs. ? 2,400 lbs., Optimal range for standard 24-85-15 lead-acid configurations.; 5. Hardware and Accessory Standardization - Connector Type: SB350 Blue, OEM specification mandates an SB350 Blue connector. Vendor must verify exact match prior to delivery.; Cable Length: 25.0 in. Minimum ? 30.0 in. Maximum.; Cable Routing: Position B or Position X layout.; Watering System: Factory-installed single-point watering system, Mandatory.; Lifting Provisions: Welded steel lifting ears/eyes compatible with standard overhead hoists.; 6. Construction and Design Requirements - Tray Construction: Heavy-duty steel tray, Minimum 10-gauge to 0.25-in. steel plate.; Tray Coating: Acid-resistant, electrostatically applied epoxy or powder-coat finish (Minimum 3 mil thickness) to prevent corrosion.; Cell Connectors: Flexible, fully insulated heavy-duty copper intercell connectors (Lead-burned or bolted). Must be protected against accidental short circuits.; Cabling: 4/0 AWG or 2/0 AWG highly flexible welding-grade copper cable, covered with acid and oil-resistant insulation. Must meet OSHA and ANSI safety requirements.; Cell Jars: High-impact, heat-resistant polypropylene or equivalent polymer construction to prevent cracking.; Electrolyte: Flooded lead acid or maintenance reduced design (if applicable); Vent Caps: Standard or Flip-top; Condition: New; 7. Mandatory Compliance - OSHA 1910.178(g) Compliance: The battery design must facilitate safe changing and charging as per Powered Industrial Truck standards, including secure covers and venting to disperse off gassing (hydrogen) safely.; ANSI/ITSDF B56.1 Compatibility: The batteries weight and center of gravity must not alter the Hyster E40XNs compliance with the Safety Standard for Low Lift and High Lift Trucks.; Lifting Provision: Must feature structurally integrated, fully welded steel lifting ears (lifting eyes) that accommodate standard non-conductive spreader bars and overhead hoists.; UL 583 Standard: The battery assembly must meet or exceed Underwriters Laboratories (UL) Standard 583 for Electric-Battery-Powered Industrial Trucks.; 8. Mandatory Warranty and Certification - U.S. Manufacturing Origin Required: The vendor must provide a formal Certificate of Origin verifying that the battery is manufactured/assembled in the United States, in compliance with the Buy American Act (BAA) / Trade Agreements Act (TAA).; Minimum 5-Year Prorated Warranty: The manufacturer must provide a minimum 60-month (5-year) prorated warranty from the date of final acceptance.; Defects and Workmanship: The warranty must explicitly cover all defects in materials and workmanship. The vendor must replace or repair failing cells/components at no additional cost during the initial full-coverage period, and on a prorated basis thereafter. Item 2 - 48 Volt Forklift Batteries, model 24-85-17 Salient Characteristics: 1. General Must Requirements - Must be fully compatible with Crown FC4510 40 (FC 4500 Series) electric forklift specifications.; Must meet battery model 24-85-17 specifications; Must be manufactured in the United States.; Must meet or exceed OEM performance standards for voltage, capacity, physical dimensions, and operation expectations.; Must be suitable for Class I sit-down counterbalance electric forklift applications.; 2. Electrical Performance Specifications - System Voltage: 48V, Mandatory for OEM controller compatibility.; Cell Count: 24 Lead-Acid Cells (Exact), Standard 2V per cell configuration.; Plate Configuration: 17 plates per cell (Equivalent), 8 positive, 9 negative plates to ensure proper energy density.; Rated Capacity (6-hour): 670Ah Minimum - 690 Ah Maximum, Mates the standard 85 Ah per positive plate requirement.; Cycle life Yield: 1,500 cycles at 80% DoD Minimum, Baseline durability for DoW operational tempo.; Charging Compatibility: Must be compatible with standard 48V industrial chargers, vendor must specify charger requirements if unique.; 3. Dimensional Tolerances and Form Factor - Tray Length: 38 in. ? 39 in.; Tray Width: 26.5 in. ? 27.25 in.; Tray Height (No Cover): 22 in. ? 23 in.; Total Height Clearance: Must not exceed 23.00 in. To ensure the battery does not impede the Crown FC seat deck/hood closure.; 4. Weight and Counterweight Requirements - Weight: 2,580 lbs. (1,170 kg) Minimum ? 3,200 lbs. (1,451kg) Maximum.; Target Service Weight: 2,600 lbs. ? 2,750 lbs., Optimal range for standard 24-85-17 lead-acid configurations.; 5. Hardware and Accessory Standardization - Connector Type: SBE 320 Blue, OEM specifications highlight the use of a SBE 320 Blue connector. Vendor must verify Crown-specific connector match prior to delivery.; Cable Length: 15 in. Minimum ? 20 in. Maximum.; Cable Routing: Position A or Position X layout.; Watering System: Factory-installed single-point watering system, (Mandatory; Flow-Rite or equivalent).; 6. Construction and Design Requirements - Tray Construction: Heavy-duty steel tray, Minimum 10-gauge to 0.25-in. steel plate.; Tray Coating: Acid-resistant, electrostatically applied epoxy or powder-coat finish (Minimum 3 mil thickness) to prevent corrosion.; Cell Connectors: Flexible, fully insulated heavy-duty copper intercell connectors. Must be protected against accidental short circuits.; Cabling: 4/0 AWG or 2/0 AWG highly flexible welding-grade copper cable, covered with acid and oil-resistant insulation. Must meet OSHA and ANSI safety requirements.; Cell Jars: High-impact, heat-resistant polypropylene or equivalent polymer construction to prevent cracking.; Electrolyte: Flooded lead acid or maintenance reduced design (if applicable); Vent Caps: Standard or Flip-top; Condition: New; 7. Mandatory Compliance - OSHA 1910.178(g) Compliance: The battery design must facilitate safe changing and charging as per Powered Industrial Truck standards, including secure covers and venting to disperse off gassing (hydrogen) safely.; ANSI/ITSDF B56.1 Compatibility: The batteries weight and center of gravity must not alter the Hyster E40XNs compliance with the Safety Standard for Low Lift and High Lift Trucks.; Lifting Provision: Must feature structurally integrated, fully welded steel lifting ears (lifting eyes) that accommodate standard non-conductive spreader bars and overhead hoists.; UL 583 Standard: The battery assembly must meet or exceed Underwriters Laboratories (UL) Standard 583 for Electric-Battery-Powered Industrial Trucks.; 8. Mandatory Warranty and Certification - U.S. Manufacturing Origin Required: The vendor must provide a formal Certificate of Origin verifying that the battery is manufactured/assembled in the United States, in compliance with the Buy American Act(BAA) / Trade Agreements Act (TAA).; Minimum 5-Year Prorated Warranty: The manufacturer must provide a minimum 60-month (5-year) prorated warranty from the date of final acceptance.; Defects and Workmanship: The warranty must explicitly cover all defects in materials and workmanship. The vendor must replace or repair failing cells/components at no additional cost during the initial full-coverage period, and on a prorated basis thereafter; Shipping Information: Tooele Army Depot, 1Tooele Army Depot, Building 503, Tooele, Utah 84074.","origin":"extract"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"W911S226U3545","place_of_performance":{"zip":"84074","street":"Tooele Army Depot"},"product_service_code":"6160"}],"due_at":"2026-07-08T06:00:00Z","due_date":"2026-07-08","closes_at":"2026-07-08T06:00:00Z","awardable":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","state":null,"country":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T07:31:38.954589Z","principal_notice_id":"99a1b78dbc254cc8989fc62127b3837f","description":{"text":"Item 1 - 48 Volt Forklift Batteries, model 24-85-15 Salient Characteristics: 1. General Requirements - Battery must be fully compatible with Hyster E40XN electric forklift specifications.; Meet battery model 24-85-15 specifications; Battery must be manufactured in the United States.; Battery must meet or exceed OEM performance standards for voltage, capacity, and physical dimensions.; Battery must be suitable for Class I electric forklift applications.; 2. Electrical Performance Specifications -System Voltage: 48V, Mandatory for OEM controller compatibility.; Cell Count: 24 LEAD-Acid Cells (Exact), Standard 2V per cell configuration.; Plate Configuration: 15 plates per cell (Equivalent), Ensures proper energy density and heat dissipation.; Rated Capacity (6-hour): 590 Ah Minimum - 610 Ah Maximum, Mates the standard 85 Ah per positive plate requirement. Must support full shift operation under normal warehouse conditions.; Cycle life Yield: 1,500 cycles at 80% DoD Minimum, Baseline durability for DoW operational tempo.; Charging Compatibility: Must be compatible with standard 48V industrial chargers; vendor must specify charger requirements if unique.; 3. Dimensional Tolerances and Form Factor - Tray Length: 34.50 in. ? 35.50 in.; Tray Width: 26.50 in. ? 27.25 in.; Tray Height (No Cover): 22.00 in. ? 22.75 in.; Total Height Clearance: Must not exceed 23.50in. Maximum, Accounts for optional battery rollers in the E40XN.; 4. Weight and Counterweight Requirements - Weight: 1,850 lbs. (839 kg) Minimum ? 2,500 lbs. (1,134kg) Maximum.; Target Service Weight: 2,300 lbs. ? 2,400 lbs., Optimal range for standard 24-85-15 lead-acid configurations.; 5. Hardware and Accessory Standardization - Connector Type: SB350 Blue, OEM specification mandates an SB350 Blue connector. Vendor must verify exact match prior to delivery.; Cable Length: 25.0 in. Minimum ? 30.0 in. Maximum.; Cable Routing: Position B or Position X layout.; Watering System: Factory-installed single-point watering system, Mandatory.; Lifting Provisions: Welded steel lifting ears/eyes compatible with standard overhead hoists.; 6. Construction and Design Requirements - Tray Construction: Heavy-duty steel tray, Minimum 10-gauge to 0.25-in. steel plate.; Tray Coating: Acid-resistant, electrostatically applied epoxy or powder-coat finish (Minimum 3 mil thickness) to prevent corrosion.; Cell Connectors: Flexible, fully insulated heavy-duty copper intercell connectors (Lead-burned or bolted). Must be protected against accidental short circuits.; Cabling: 4/0 AWG or 2/0 AWG highly flexible welding-grade copper cable, covered with acid and oil-resistant insulation. Must meet OSHA and ANSI safety requirements.; Cell Jars: High-impact, heat-resistant polypropylene or equivalent polymer construction to prevent cracking.; Electrolyte: Flooded lead acid or maintenance reduced design (if applicable); Vent Caps: Standard or Flip-top; Condition: New; 7. Mandatory Compliance - OSHA 1910.178(g) Compliance: The battery design must facilitate safe changing and charging as per Powered Industrial Truck standards, including secure covers and venting to disperse off gassing (hydrogen) safely.; ANSI/ITSDF B56.1 Compatibility: The batteries weight and center of gravity must not alter the Hyster E40XNs compliance with the Safety Standard for Low Lift and High Lift Trucks.; Lifting Provision: Must feature structurally integrated, fully welded steel lifting ears (lifting eyes) that accommodate standard non-conductive spreader bars and overhead hoists.; UL 583 Standard: The battery assembly must meet or exceed Underwriters Laboratories (UL) Standard 583 for Electric-Battery-Powered Industrial Trucks.; 8. Mandatory Warranty and Certification - U.S. Manufacturing Origin Required: The vendor must provide a formal Certificate of Origin verifying that the battery is manufactured/assembled in the United States, in compliance with the Buy American Act (BAA) / Trade Agreements Act (TAA).; Minimum 5-Year Prorated Warranty: The manufacturer must provide a minimum 60-month (5-year) prorated warranty from the date of final acceptance.; Defects and Workmanship: The warranty must explicitly cover all defects in materials and workmanship. The vendor must replace or repair failing cells/components at no additional cost during the initial full-coverage period, and on a prorated basis thereafter. Item 2 - 48 Volt Forklift Batteries, model 24-85-17 Salient Characteristics: 1. General Must Requirements - Must be fully compatible with Crown FC4510 40 (FC 4500 Series) electric forklift specifications.; Must meet battery model 24-85-17 specifications; Must be manufactured in the United States.; Must meet or exceed OEM performance standards for voltage, capacity, physical dimensions, and operation expectations.; Must be suitable for Class I sit-down counterbalance electric forklift applications.; 2. Electrical Performance Specifications - System Voltage: 48V, Mandatory for OEM controller compatibility.; Cell Count: 24 Lead-Acid Cells (Exact), Standard 2V per cell configuration.; Plate Configuration: 17 plates per cell (Equivalent), 8 positive, 9 negative plates to ensure proper energy density.; Rated Capacity (6-hour): 670Ah Minimum - 690 Ah Maximum, Mates the standard 85 Ah per positive plate requirement.; Cycle life Yield: 1,500 cycles at 80% DoD Minimum, Baseline durability for DoW operational tempo.; Charging Compatibility: Must be compatible with standard 48V industrial chargers, vendor must specify charger requirements if unique.; 3. Dimensional Tolerances and Form Factor - Tray Length: 38 in. ? 39 in.; Tray Width: 26.5 in. ? 27.25 in.; Tray Height (No Cover): 22 in. ? 23 in.; Total Height Clearance: Must not exceed 23.00 in. To ensure the battery does not impede the Crown FC seat deck/hood closure.; 4. Weight and Counterweight Requirements - Weight: 2,580 lbs. (1,170 kg) Minimum ? 3,200 lbs. (1,451kg) Maximum.; Target Service Weight: 2,600 lbs. ? 2,750 lbs., Optimal range for standard 24-85-17 lead-acid configurations.; 5. Hardware and Accessory Standardization - Connector Type: SBE 320 Blue, OEM specifications highlight the use of a SBE 320 Blue connector. Vendor must verify Crown-specific connector match prior to delivery.; Cable Length: 15 in. Minimum ? 20 in. Maximum.; Cable Routing: Position A or Position X layout.; Watering System: Factory-installed single-point watering system, (Mandatory; Flow-Rite or equivalent).; 6. Construction and Design Requirements - Tray Construction: Heavy-duty steel tray, Minimum 10-gauge to 0.25-in. steel plate.; Tray Coating: Acid-resistant, electrostatically applied epoxy or powder-coat finish (Minimum 3 mil thickness) to prevent corrosion.; Cell Connectors: Flexible, fully insulated heavy-duty copper intercell connectors. Must be protected against accidental short circuits.; Cabling: 4/0 AWG or 2/0 AWG highly flexible welding-grade copper cable, covered with acid and oil-resistant insulation. Must meet OSHA and ANSI safety requirements.; Cell Jars: High-impact, heat-resistant polypropylene or equivalent polymer construction to prevent cracking.; Electrolyte: Flooded lead acid or maintenance reduced design (if applicable); Vent Caps: Standard or Flip-top; Condition: New; 7. Mandatory Compliance - OSHA 1910.178(g) Compliance: The battery design must facilitate safe changing and charging as per Powered Industrial Truck standards, including secure covers and venting to disperse off gassing (hydrogen) safely.; ANSI/ITSDF B56.1 Compatibility: The batteries weight and center of gravity must not alter the Hyster E40XNs compliance with the Safety Standard for Low Lift and High Lift Trucks.; Lifting Provision: Must feature structurally integrated, fully welded steel lifting ears (lifting eyes) that accommodate standard non-conductive spreader bars and overhead hoists.; UL 583 Standard: The battery assembly must meet or exceed Underwriters Laboratories (UL) Standard 583 for Electric-Battery-Powered Industrial Trucks.; 8. Mandatory Warranty and Certification - U.S. Manufacturing Origin Required: The vendor must provide a formal Certificate of Origin verifying that the battery is manufactured/assembled in the United States, in compliance with the Buy American Act(BAA) / Trade Agreements Act (TAA).; Minimum 5-Year Prorated Warranty: The manufacturer must provide a minimum 60-month (5-year) prorated warranty from the date of final acceptance.; Defects and Workmanship: The warranty must explicitly cover all defects in materials and workmanship. The vendor must replace or repair failing cells/components at no additional cost during the initial full-coverage period, and on a prorated basis thereafter; Shipping Information: Tooele Army Depot, 1Tooele Army Depot, Building 503, Tooele, Utah 84074.","html":null,"origin":"extract"},"contacts":[{"name":"Traci Sablan","role":"primary","email":"traci.l.sablan.civ@army.mil","phone":"4358332713"}],"place_of_performance":{"zip":"84074","street":"Tooele Army Depot"},"office_address":{"zip":"13602-5220","city":"FORT DRUM","state":"NY","country":"USA"},"naics_codes":["335910"],"award":null,"attachments":[],"awards":[],"related":[{"key":"W911S226U4429","latest_notice_id":"057d5d78295240f9a4ae00da8c9319c6","title":"Firearm Training Sensor","solicitation_number":"W911S226U4429","notice_type":"k","first_type":"k","first_posted":"2026-09-10","last_posted":"2026-09-10","notices":1,"due_at":"2026-09-16T17:00:00Z","due_date":"2026-09-16","closes_at":"2026-09-16T17:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"332994","psc":"6920","set_aside":"SBA","state":null,"country":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T07:31:38.954589Z"},{"key":"W911S226U4390","latest_notice_id":"c569b842531246d19e3d425758c78c8a","title":"8JR Air Rifles","solicitation_number":"W911S226U4390","notice_type":"k","first_type":"k","first_posted":"2026-09-02","last_posted":"2026-09-15","notices":5,"due_at":"2026-09-16T17:00:00Z","due_date":"2026-09-16","closes_at":"2026-09-16T17:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"339999","psc":"6910","set_aside":"SBA","state":null,"country":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T07:50:43.959643Z"},{"key":"W911S226U3820","latest_notice_id":"b56082af73e14ac497f384c9459b4b98","title":"Labbot","solicitation_number":"W911S226U3820","notice_type":"k","first_type":"k","first_posted":"2026-07-24","last_posted":"2026-09-11","notices":3,"due_at":"2026-09-16T17:00:00Z","due_date":"2026-09-16","closes_at":"2026-09-16T17:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"334516","psc":"6630","set_aside":"SBA","state":null,"country":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T07:31:38.954589Z"},{"key":"W911S226U4398","latest_notice_id":"454a4127f6d749f78c50277280c9ed3d","title":"Portable Generator","solicitation_number":"W911S226U4398","notice_type":"k","first_type":"k","first_posted":"2026-09-10","last_posted":"2026-09-10","notices":1,"due_at":"2026-09-16T17:00:00Z","due_date":"2026-09-16","closes_at":"2026-09-16T17:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"335312","psc":"6115","set_aside":"SBA","state":null,"country":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T07:31:38.954589Z"},{"key":"W911S226U4441","latest_notice_id":"327b622bb90a4228a27c13038219627c","title":"Portable Radios and Charging Stations","solicitation_number":"W911S226U4441","notice_type":"k","first_type":"k","first_posted":"2026-09-09","last_posted":"2026-09-10","notices":2,"due_at":"2026-09-16T17:00:00Z","due_date":"2026-09-16","closes_at":"2026-09-16T17:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"334220","psc":"5820","set_aside":"SBA","state":null,"country":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T07:31:38.954589Z"}]}