{"canonical":"https://abierto.us/opportunities/w911s225u2149","key":"W911S225U2149","url":"https://abierto.us/opportunities/w911s225u2149","title":"3 EACH AIR COMPRESSORS","solicitation_number":"W911S225U2149","notice_type":"k","open":false,"response_deadline":"2025-10-06T16:00:00Z","first_posted":"2025-09-26","last_posted":"2025-09-30","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE ARMY","office":"W6QM MICC-FT DRUM","naics":"333912","psc":"4310","set_aside":"SBA","place_state":null,"place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"2fc3b387e6dc40febb56520c5c40e78b","title":"3 EACH AIR COMPRESSORS","solicitation_number":"W911S225U2149","notice_type":"k","base_type":"k","posted":"2025-09-26","posted_at":null,"due_at":"2025-10-06T16:00:00Z","due_date":"2025-10-06","cancelled":null,"archived":null,"archive_date":"2026-09-26","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/2fc3b387e6dc40febb56520c5c40e78b/view","enriched":false,"history":[]},{"notice_id":"32d9260a09d148858e16efa07672eb88","title":"3 EACH AIR COMPRESSORS","solicitation_number":"W911S225U2149","notice_type":"k","base_type":"k","posted":"2025-09-26","posted_at":null,"due_at":"2025-10-06T16:00:00Z","due_date":"2025-10-06","cancelled":null,"archived":null,"archive_date":"2026-09-26","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/32d9260a09d148858e16efa07672eb88/view","enriched":false,"history":[]},{"notice_id":"82194059e19a4922bc4556042b1b37e0","title":"3 EACH AIR COMPRESSORS","solicitation_number":"W911S225U2149","notice_type":"k","base_type":"k","posted":"2025-09-30","posted_at":null,"due_at":"2025-10-06T16:00:00Z","due_date":"2025-10-06","cancelled":null,"archived":null,"archive_date":"2026-09-30","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/82194059e19a4922bc4556042b1b37e0/view","enriched":false,"history":[]}],"latest_notice_id":"82194059e19a4922bc4556042b1b37e0","first_type":"k","notices":[{"dates":{"posted":"2025-09-26","response_deadline":{"raw":"2025-10-06T10:00:00-06:00","utc":"2025-10-06T16:00:00Z","date":"2025-10-06","time":"10:00:00","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/2fc3b387e6dc40febb56520c5c40e78b/view"},"naics":{"codes":["333912"],"primary":"333912"},"title":"3 EACH AIR COMPRESSORS","agency":{"office":{"code":"W911S2","name":"W6QM MICC-FT DRUM"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"13602-5220","city":"FORT DRUM","state":"NY","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"archive_date":"2026-09-26","archive_type":"auto_custom"},"contacts":[{"name":"David Fortune","role":"primary","email":"david.c.fortune.civ@army.mil","phone":"9184206445"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"2fc3b387e6dc40febb56520c5c40e78b","provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"3f59209463433eba6899e195a597c64d-29\"","fetched_at":"2026-09-16T17:45:38.712931Z","row_sha256":"bd01649bb0d5b7fe5bbdc76ba14627343397716c5f627eb262003280766fca49","last_modified":"2026-09-16T03:30:52Z"},"updated_at":"2026-09-16T17:45:38.712931Z","first_seen_at":"2026-09-16T17:45:38.712931Z"},"description":{"text":"Gardner Denver ElectraSaverII STG2-60, or equivalentDirect drive rotary screw compressor, Qty (3)Mounted on a 70? x 52? skidiii. 60 hp, 460/3/60 volt ODP 1800 RPM drive motoriv. 287 cfm rating at 125 PSIGv. 81 dBA sound ratingvi. Water cooled1. Fan bank cooler to be provided by MCAAPvii. Oil cooler/ After-cooler coreviii. Auto water temperature regulatorix. Automatic water shutoffx. Pressure relief valvexi. NEMA 4 enclosure1. Emergency stop equipped2. Load/ no load and inlet modulation controls3. Quiet enclosurexii. Warranty parts kitxiii. 5 gal pail of synthetic lubricant to be suppliedxiv. Start-up services to include a factory trained service technician forstart-up/ training1. MCAAP to complete the installation of the compressor priorto start-up2. MCAAP reserves the possible need for two separate start-updates, and this service should be quoted accordinglyProposal, Reviews, Drawings, Documentation, and Data","origin":"extract"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"W911S225U2149","place_of_performance":{"zip":"74501","street":"McAlester Army Ammunition Plant 1 C-Tree Road, Building 6 McAlester, OK 74501"},"product_service_code":"4310"},{"dates":{"posted":"2025-09-26","response_deadline":{"raw":"2025-10-06T10:00:00-06:00","utc":"2025-10-06T16:00:00Z","date":"2025-10-06","time":"10:00:00","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/32d9260a09d148858e16efa07672eb88/view"},"naics":{"codes":["333912"],"primary":"333912"},"title":"3 EACH AIR COMPRESSORS","agency":{"office":{"code":"W911S2","name":"W6QM MICC-FT DRUM"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"13602-5220","city":"FORT DRUM","state":"NY","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"archive_date":"2026-09-26","archive_type":"auto_custom"},"contacts":[{"name":"David Fortune","role":"primary","email":"david.c.fortune.civ@army.mil","phone":"9184206445"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"32d9260a09d148858e16efa07672eb88","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"3f59209463433eba6899e195a597c64d-29\"","fetched_at":"2026-09-16T17:45:38.712931Z","row_sha256":"9fcb6a3d418f6d3d4cc20ae9979ff45268fa814f2ed19d6d7dadac3c7a9ebc6e","last_modified":"2026-09-16T03:30:52Z"},"updated_at":"2026-09-16T17:45:38.712931Z","first_seen_at":"2026-09-16T17:45:38.712931Z"},"description":{"text":"Gardner Denver ElectraSaverII STG2-60, or equivalentDirect drive rotary screw compressor, Qty (3)Mounted on a 70? x 52? skidiii. 60 hp, 460/3/60 volt ODP 1800 RPM drive motoriv. 287 cfm rating at 125 PSIGv. 81 dBA sound ratingvi. Water cooled1. Fan bank cooler to be provided by MCAAPvii. Oil cooler/ After-cooler coreviii. Auto water temperature regulatorix. Automatic water shutoffx. Pressure relief valvexi. NEMA 4 enclosure1. Emergency stop equipped2. Load/ no load and inlet modulation controls3. Quiet enclosurexii. Warranty parts kitxiii. 5 gal pail of synthetic lubricant to be suppliedxiv. Start-up services to include a factory trained service technician forstart-up/ training1. MCAAP to complete the installation of the compressor priorto start-up2. MCAAP reserves the possible need for two separate start-updates, and this service should be quoted accordinglyProposal, Reviews, Drawings, Documentation, and Data","origin":"extract"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"W911S225U2149","place_of_performance":{"zip":"74501","street":"McAlester Army Ammunition Plant 1 C-Tree Road, Building 6 McAlester, OK 74501"},"product_service_code":"4310"},{"dates":{"posted":"2025-09-30","response_deadline":{"raw":"2025-10-06T10:00:00-06:00","utc":"2025-10-06T16:00:00Z","date":"2025-10-06","time":"10:00:00","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/82194059e19a4922bc4556042b1b37e0/view"},"naics":{"codes":["333912"],"primary":"333912"},"title":"3 EACH AIR COMPRESSORS","agency":{"office":{"code":"W911S2","name":"W6QM MICC-FT DRUM"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"13602-5220","city":"FORT DRUM","state":"NY","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"archive_date":"2026-09-30","archive_type":"auto_custom"},"contacts":[{"name":"David Fortune","role":"primary","email":"david.c.fortune.civ@army.mil","phone":"9184206445"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"82194059e19a4922bc4556042b1b37e0","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"3f59209463433eba6899e195a597c64d-29\"","fetched_at":"2026-09-16T17:45:38.712931Z","row_sha256":"3dccc00d1b7aaf10c938e12b06a91782fe3130ccd2e7046ed289e74f6e8a1af9","last_modified":"2026-09-16T03:30:52Z"},"updated_at":"2026-09-16T17:45:38.712931Z","first_seen_at":"2026-09-16T17:45:38.712931Z"},"description":{"text":"Amendment is because in the synopsis, under xi. NEMA 4 enclosure 3., it says Quiet enclosure. These words need to be omitted. We are not needing a quiet enclosure for these compressors. Gardner Denver ElectraSaver II STG2-60, or equivalent Direct drive rotary screw compressor, Qty (3) Mounted on a 70-inch x 52-inch skid iii. 60 hp, 460/3/60-volt ODP 1800 RPM drive motor iv. 287 cfm rating at 125 PSIG v. 81 dBA sound rating vi. Water cooled1. Fan bank cooler to be provided by MCAAP vii. Oil cooler/ After-cooler core viii. Auto water temperature regulator ix. Automatic water shut off x. Pressure relief valve xi. NEMA 4 enclosure1. Emergency stop equipped 2. Load/ no load and inlet modulation controls3. Quiet enclosure xii. Warranty parts kit xiii. 5-gal pail of synthetic lubricant to be supplied xiv. Start-up services to include a factory trained service technician for start-up/ training1. MCAAP to complete the installation of the compressor prior to start-up2. MCAAP reserves the possible need for two separate start-updates, and this service should be quoted accordingly Proposal, Reviews, Drawings, Documentation, and Data","origin":"extract"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"W911S225U2149","place_of_performance":{"zip":"74501","street":"McAlester Army Ammunition Plant 1 C-Tree Road, Building 6 McAlester, OK 74501"},"product_service_code":"4310"}],"due_at":"2025-10-06T16:00:00Z","due_date":"2025-10-06","closes_at":"2025-10-06T16:00:00Z","awardable":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z","principal_notice_id":"82194059e19a4922bc4556042b1b37e0","description":{"text":"Amendment is because in the synopsis, under xi. NEMA 4 enclosure 3., it says Quiet enclosure. These words need to be omitted. We are not needing a quiet enclosure for these compressors. Gardner Denver ElectraSaver II STG2-60, or equivalent Direct drive rotary screw compressor, Qty (3) Mounted on a 70-inch x 52-inch skid iii. 60 hp, 460/3/60-volt ODP 1800 RPM drive motor iv. 287 cfm rating at 125 PSIG v. 81 dBA sound rating vi. Water cooled1. Fan bank cooler to be provided by MCAAP vii. Oil cooler/ After-cooler core viii. Auto water temperature regulator ix. Automatic water shut off x. Pressure relief valve xi. NEMA 4 enclosure1. Emergency stop equipped 2. Load/ no load and inlet modulation controls3. Quiet enclosure xii. Warranty parts kit xiii. 5-gal pail of synthetic lubricant to be supplied xiv. Start-up services to include a factory trained service technician for start-up/ training1. MCAAP to complete the installation of the compressor prior to start-up2. MCAAP reserves the possible need for two separate start-updates, and this service should be quoted accordingly Proposal, Reviews, Drawings, Documentation, and Data","html":null,"origin":"extract"},"contacts":[{"name":"David Fortune","role":"primary","email":"david.c.fortune.civ@army.mil","phone":"9184206445"}],"place_of_performance":{"zip":"74501","street":"McAlester Army Ammunition Plant 1 C-Tree Road, Building 6 McAlester, OK 74501"},"office_address":{"zip":"13602-5220","city":"FORT DRUM","state":"NY","country":"USA"},"naics_codes":["333912"],"award":null,"attachments":[],"awards":[],"related":[{"key":"W911S226U4411","latest_notice_id":"177d2488d8e94069ae3a90fd74d89baa","title":"Automated Traffic Enforcement Trailer","solicitation_number":"W911S226U4411","notice_type":"k","first_type":"k","first_posted":"2026-09-04","last_posted":"2026-09-14","notices":2,"due_at":"2026-09-17T12:35:00Z","due_date":"2026-09-17","closes_at":"2026-09-17T12:35:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"334511","psc":"2510","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"W911S226U4453","latest_notice_id":"d9542022deb747f984bd88ecc7f39e0b","title":"CM-300 UHF (V2) Transmitter and Receiver","solicitation_number":"W911S226U4453","notice_type":"k","first_type":"k","first_posted":"2026-09-10","last_posted":"2026-09-10","notices":1,"due_at":"2026-09-17T13:00:00Z","due_date":"2026-09-17","closes_at":"2026-09-17T13:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"334220","psc":"5820","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"W911S226U4445","latest_notice_id":"fc11b2fe000a4c7b867e298bb2faccfa","title":"Metal Wardrobe Lockers","solicitation_number":"W911S226U4445","notice_type":"k","first_type":"k","first_posted":"2026-09-10","last_posted":"2026-09-10","notices":2,"due_at":"2026-09-17T14:00:00Z","due_date":"2026-09-17","closes_at":"2026-09-17T14:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"337215","psc":"7125","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"W911S226U4467","latest_notice_id":"6532925d5c7f4bf7afe0cbc1f7bf7637","title":"FIRE STATION RECLINERS","solicitation_number":"W911S226U4467","notice_type":"k","first_type":"k","first_posted":"2026-09-10","last_posted":"2026-09-10","notices":1,"due_at":"2026-09-17T14:50:00Z","due_date":"2026-09-17","closes_at":"2026-09-17T14:50:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"337121","psc":"7105","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"W911S226U4478","latest_notice_id":"f3baa1f84c3d4eb197bfbe47551270ce","title":"Electronic Scoring Target System","solicitation_number":"W911S226U4478","notice_type":"k","first_type":"k","first_posted":"2026-09-11","last_posted":"2026-09-11","notices":1,"due_at":"2026-09-17T15:00:00Z","due_date":"2026-09-17","closes_at":"2026-09-17T15:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911S2","office_name":"W6QM MICC-FT DRUM","naics":"339920","psc":"6930","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"}]}