{"canonical":"https://abierto.us/opportunities/w911kb25r0019","key":"W911KB25R0019","url":"https://abierto.us/opportunities/w911kb25r0019","title":"FTG257 MISSILE FIELD 2 POWER REDUNDANCY","solicitation_number":"W911KB25R0019","notice_type":"o","open":false,"response_deadline":"2025-07-16T22:00:00Z","first_posted":"2024-10-02","last_posted":"2025-07-14","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE ARMY","office":"W2SN ENDIST ALASKA","naics":"237130","psc":"Y1BF","set_aside":"8A","place_state":"AK","place_county":"02240","place_county_name":"Southeast Fairbanks Census Area","place_city":"0226100","place_city_name":"Fort Greely","winner":null,"award_amount":null,"publications":[{"notice_id":"7af3baf05e404157a97421d223953e42","title":"FTG257 MF2 Power Redundancy","solicitation_number":"W911KB25R0019","notice_type":"r","base_type":"r","posted":"2024-10-02","posted_at":null,"due_at":"2024-10-16T22:00:00Z","due_date":"2024-10-16","cancelled":null,"archived":null,"archive_date":"2024-10-31","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/7af3baf05e404157a97421d223953e42/view","enriched":false,"history":[]},{"notice_id":"1cefe941a125449f9c249640f273f2a1","title":"FTG257 MF2 Power Redundancy","solicitation_number":"W911KB25R0019","notice_type":"r","base_type":"r","posted":"2024-10-04","posted_at":null,"due_at":"2024-10-16T22:00:00Z","due_date":"2024-10-16","cancelled":null,"archived":null,"archive_date":"2024-10-31","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/1cefe941a125449f9c249640f273f2a1/view","enriched":false,"history":[]},{"notice_id":"2bcaee9d9c0b47a8b65fd59b23c098ef","title":"FTG257 MF2 Power Redundancy","solicitation_number":"W911KB25R0019","notice_type":"r","base_type":"r","posted":"2024-10-08","posted_at":null,"due_at":"2024-10-16T22:00:00Z","due_date":"2024-10-16","cancelled":null,"archived":null,"archive_date":"2024-10-31","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/2bcaee9d9c0b47a8b65fd59b23c098ef/view","enriched":false,"history":[]},{"notice_id":"92c8a52826114abb8c068bef133f6df3","title":"FTG257 Missile Field 2 Power Redundancy, Fort Greely, Alaska","solicitation_number":"W911KB25R0019","notice_type":"p","base_type":"p","posted":"2025-01-28","posted_at":null,"due_at":"2025-02-13T00:00:00Z","due_date":"2025-02-12","cancelled":null,"archived":null,"archive_date":"2025-02-27","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/92c8a52826114abb8c068bef133f6df3/view","enriched":false,"history":[]},{"notice_id":"29fe77495f0143a9a27b3787e6fe3431","title":"FTG257 MISSILE FIELD 2 POWER REDUNDANCY","solicitation_number":"W911KB25R0019","notice_type":"o","base_type":"o","posted":"2025-03-19","posted_at":null,"due_at":"2025-04-22T22:00:00Z","due_date":"2025-04-22","cancelled":null,"archived":null,"archive_date":"2026-03-19","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/29fe77495f0143a9a27b3787e6fe3431/view","enriched":false,"history":[]},{"notice_id":"df69891d30b649d882d3f75538c398ec","title":"FTG257 MISSILE FIELD 2 POWER REDUNDANCY","solicitation_number":"W911KB25R0019","notice_type":"o","base_type":"o","posted":"2025-03-28","posted_at":null,"due_at":"2025-04-22T22:00:00Z","due_date":"2025-04-22","cancelled":null,"archived":null,"archive_date":"2026-03-28","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/df69891d30b649d882d3f75538c398ec/view","enriched":false,"history":[]},{"notice_id":"2a3c64561f9d4fc5850a3d3d9f7a2b65","title":"FTG257 MISSILE FIELD 2 POWER REDUNDANCY","solicitation_number":"W911KB25R0019","notice_type":"o","base_type":"o","posted":"2025-04-29","posted_at":null,"due_at":"2025-05-06T22:00:00Z","due_date":"2025-05-06","cancelled":null,"archived":null,"archive_date":"2026-04-03","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/2a3c64561f9d4fc5850a3d3d9f7a2b65/view","enriched":false,"history":[]},{"notice_id":"66452e76fbf44e11a07c9b3650be4a88","title":"FTG257 MISSILE FIELD 2 POWER REDUNDANCY","solicitation_number":"W911KB25R0019","notice_type":"o","base_type":"o","posted":"2025-05-01","posted_at":null,"due_at":"2025-05-06T22:00:00Z","due_date":"2025-05-06","cancelled":null,"archived":null,"archive_date":"2026-05-01","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/66452e76fbf44e11a07c9b3650be4a88/view","enriched":false,"history":[]},{"notice_id":"f8f0129097d540588c28b13d2753b21e","title":"FTG257 MISSILE FIELD 2 POWER REDUNDANCY","solicitation_number":"W911KB25R0019","notice_type":"o","base_type":"o","posted":"2025-05-01","posted_at":null,"due_at":"2025-05-06T22:00:00Z","due_date":"2025-05-06","cancelled":null,"archived":null,"archive_date":"2026-05-01","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/f8f0129097d540588c28b13d2753b21e/view","enriched":false,"history":[]},{"notice_id":"679f7c49adbe482285dadf45e8101b13","title":"FTG257 MISSILE FIELD 2 POWER REDUNDANCY","solicitation_number":"W911KB25R0019","notice_type":"o","base_type":"o","posted":"2025-05-06","posted_at":null,"due_at":"2025-05-27T22:00:00Z","due_date":"2025-05-27","cancelled":null,"archived":null,"archive_date":"2026-05-06","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/679f7c49adbe482285dadf45e8101b13/view","enriched":false,"history":[]},{"notice_id":"a7f5a5f9620649708f1448dc75b9f428","title":"FTG257 MISSILE FIELD 2 POWER REDUNDANCY","solicitation_number":"W911KB25R0019","notice_type":"o","base_type":"o","posted":"2025-05-06","posted_at":null,"due_at":"2025-05-27T22:00:00Z","due_date":"2025-05-27","cancelled":null,"archived":null,"archive_date":"2026-05-06","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/a7f5a5f9620649708f1448dc75b9f428/view","enriched":false,"history":[]},{"notice_id":"3e416ca522ae4eb6976efaac8fcfb3d0","title":"FTG257 MISSILE FIELD 2 POWER REDUNDANCY","solicitation_number":"W911KB25R0019","notice_type":"o","base_type":"o","posted":"2025-05-13","posted_at":null,"due_at":"2025-05-27T22:00:00Z","due_date":"2025-05-27","cancelled":null,"archived":null,"archive_date":"2026-05-13","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/3e416ca522ae4eb6976efaac8fcfb3d0/view","enriched":false,"history":[]},{"notice_id":"dfa371c0983c470b8c73a7ac050a3738","title":"FTG257 MISSILE FIELD 2 POWER REDUNDANCY","solicitation_number":"W911KB25R0019","notice_type":"o","base_type":"o","posted":"2025-05-13","posted_at":null,"due_at":"2025-05-27T22:00:00Z","due_date":"2025-05-27","cancelled":null,"archived":null,"archive_date":"2026-05-13","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/dfa371c0983c470b8c73a7ac050a3738/view","enriched":false,"history":[]},{"notice_id":"06cdb5428af0497aa2ec7d07134fca3a","title":"FTG257 MISSILE FIELD 2 POWER REDUNDANCY","solicitation_number":"W911KB25R0019","notice_type":"o","base_type":"o","posted":"2025-05-23","posted_at":null,"due_at":"2025-05-27T22:00:00Z","due_date":"2025-05-27","cancelled":null,"archived":null,"archive_date":"2026-05-23","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/06cdb5428af0497aa2ec7d07134fca3a/view","enriched":false,"history":[]},{"notice_id":"20fde15f83054f73b9bce5131fbb434c","title":"FTG257 MISSILE FIELD 2 POWER REDUNDANCY","solicitation_number":"W911KB25R0019","notice_type":"o","base_type":"o","posted":"2025-05-23","posted_at":null,"due_at":"2025-05-27T22:00:00Z","due_date":"2025-05-27","cancelled":null,"archived":null,"archive_date":"2026-05-23","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/20fde15f83054f73b9bce5131fbb434c/view","enriched":false,"history":[]},{"notice_id":"16114f8aedab4f799b63f88189f448b3","title":"FTG257 MISSILE FIELD 2 POWER REDUNDANCY","solicitation_number":"W911KB25R0019","notice_type":"o","base_type":"o","posted":"2025-07-14","posted_at":null,"due_at":"2025-07-16T22:00:00Z","due_date":"2025-07-16","cancelled":null,"archived":null,"archive_date":"2026-07-14","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/16114f8aedab4f799b63f88189f448b3/view","enriched":false,"history":[]},{"notice_id":"4c7583460e16426996c9954bcb3f6691","title":"FTG257 MISSILE FIELD 2 POWER REDUNDANCY","solicitation_number":"W911KB25R0019","notice_type":"o","base_type":"o","posted":"2025-07-14","posted_at":null,"due_at":"2025-07-16T22:00:00Z","due_date":"2025-07-16","cancelled":null,"archived":null,"archive_date":"2026-07-14","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/4c7583460e16426996c9954bcb3f6691/view","enriched":false,"history":[]}],"latest_notice_id":"4c7583460e16426996c9954bcb3f6691","first_type":"r","notices":[{"dates":{"posted":"2024-10-02","response_deadline":{"raw":"2024-10-16T14:00:00-08:00","utc":"2024-10-16T22:00:00Z","date":"2024-10-16","time":"14:00:00","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/7af3baf05e404157a97421d223953e42/view"},"naics":{"codes":["237130"],"primary":"237130"},"title":"FTG257 MF2 Power Redundancy","agency":{"office":{"code":"W911KB","name":"W2SN ENDIST ALASKA"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"99506-0898","city":"ANCHORAGE","state":"AK","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-10-31","archive_type":"auto15"},"contacts":[{"name":"Brittney Morrison","role":"primary","email":"brittney.morrison@usace.army.mil"},{"name":"Michelle Nelsen","role":"secondary","email":"michelle.nelsen@usace.army.mil","phone":"9077532527"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"7af3baf05e404157a97421d223953e42","provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T19:12:38.374141Z","row_sha256":"41f114038fea6cb7ca79e4cf474eb40de4f7e98fe75ea2af7fca151e0d3c15de","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-09-16T19:12:38.374141Z","first_seen_at":"2026-09-16T19:12:38.374141Z"},"description":{"text":"Project Name: FTG257 Missile Field 2 Power Redundancy Notice ID: W911KB25R0019 THIS IS A SOURCES SOUGHT NOTICE ONLY. PROPOSALS AND BIDS WILL NOT BE ACCEPTED FOR THIS NOTICE. THIS IS NOT A PRE-SOLICITATION. The Alaska District of the U.S. Army Corps of Engineers is conducting market research to facilitate a determination of acquisition strategy prior to releasing a solicitation for this anticipated project. The determination of acquisition strategy lies solely with the Government and will be based on market research and information available to the Government from other sources. Please note that this Sources Sought is for information only and does not constitute a solicitation for competitive proposals/bids and is not to be construed as a commitment by the Government. However, all interested parties who believe they can meet the requirement are invited to submit information describing their capability to provide the required services. The intent of this Sources Sought is to solicit interest from qualified firms with a primary North American Industrial Classification System (NAICS) code of 237130, Power and communication line and related structures construction which has a size standard of $45.0 million for a potential acquisition. DESCRIPTION OF WORK: The purpose of the project is to provide electrical power redundancy to the Missile Field 3 silo interface vaults by adding Automatic Transfer Switches and Main Lug Only distribution panels with Molded Case Circuit Breakers. The SUS A & B switchgear will be physically separated, have enhanced coordination/protection features incorporated, and will be converted from a Main-Tie-Main to a Main-Tie-Tie-Main configuration. Additionally, the Power Control and Monitoring System (PCMS) and Power Quality Monitoring System (PQMS) will be extended to Missile Field 3. THIS IS A SOURCES SOUGHT OPEN TO ALL QUALIFIED PRIME CONTRACTOR FIRMS (Large and Small Businesses under NAICS 237130). All interested firms are encouraged to respond to this announcement no later than October 16 2024, by 2:00 PM Alaska Standard Time, by submitting all requested documentation listed below via email to Brittney.morrison@usace.army.mil and michelle.nelsen@usace.army.mil. Interested prime contractor firms are encouraged to submit a capabilities package (not exceeding 5 pages) demonstrating their ability to perform the work described above. Packages should include the following information regarding their company: 1. Company Name, Address, UEI Number, Cage Code, Business Size under the applicable NAICS above, and Point of Contact information including email and phone number. 2. Large or Small Business status under the applicable NAICS above, and type of small business (8a, HUBZone, Service-Disabled Veteran-Owned, Women-Owned, etc.) 3. Firm’s single project bonding capability/limit. 4. Demonstration of the firm’s experience as a prime contractor on projects of similar size, type, and complexity with the past ten years. List actual projects completed and include project title, location, and a brief description of the project including dollar amount, and work that was self-performed. 5. Your company’s intent to bid/propose on this project as a prime contractor. Interested parties are invited to submit a response to this Sources Sought by the response time stated above. Please submit all documentation by email in PDF format. Responses received after this time and date may not be reviewed.","origin":"extract"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"W911KB25R0019","place_of_performance":{"city":{"name":"Fort Greely"},"state":{"code":"AK"},"country":{"code":"USA"}},"product_service_code":"Y1BF"},{"dates":{"posted":"2024-10-04","response_deadline":{"raw":"2024-10-16T14:00:00-08:00","utc":"2024-10-16T22:00:00Z","date":"2024-10-16","time":"14:00:00","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/1cefe941a125449f9c249640f273f2a1/view"},"naics":{"codes":["237130"],"primary":"237130"},"title":"FTG257 MF2 Power Redundancy","agency":{"office":{"code":"W911KB","name":"W2SN ENDIST ALASKA"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"99506-0898","city":"ANCHORAGE","state":"AK","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-10-31","archive_type":"auto15"},"contacts":[{"name":"Brittney Morrison","role":"primary","email":"brittney.morrison@usace.army.mil"},{"name":"Michelle Nelsen","role":"secondary","email":"michelle.nelsen@usace.army.mil","phone":"9077532527"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"1cefe941a125449f9c249640f273f2a1","provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T19:12:38.374141Z","row_sha256":"7fb6f1c259438fc5fcc870d9f989d694ef6596a0a2d575a7bc3c7af0e6801b82","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-09-16T19:12:38.374141Z","first_seen_at":"2026-09-16T19:12:38.374141Z"},"description":{"text":"Project Name: FTG257 Missile Field 2 Power Redundancy Notice ID: W911KB25R0019 THIS IS A SOURCES SOUGHT NOTICE ONLY. PROPOSALS AND BIDS WILL NOT BE ACCEPTED FOR THIS NOTICE. THIS IS NOT A PRE-SOLICITATION. The Alaska District of the U.S. Army Corps of Engineers is conducting market research to facilitate a determination of acquisition strategy prior to releasing a solicitation for this anticipated project. The determination of acquisition strategy lies solely with the Government and will be based on market research and information available to the Government from other sources. Please note that this Sources Sought is for information only and does not constitute a solicitation for competitive proposals/bids and is not to be construed as a commitment by the Government. However, all interested parties who believe they can meet the requirement are invited to submit information describing their capability to provide the required services. The intent of this Sources Sought is to solicit interest from qualified firms with a primary North American Industrial Classification System (NAICS) code of 237130, Power and communication line and related structures construction which has a size standard of $45.0 million for a potential acquisition. DESCRIPTION OF WORK: The purpose of the project is to provide electrical power redundancy to the Missile Field 2 silo interface vaults by adding Automatic Transfer Switches and Main Lug Only distribution panels with Molded Case Circuit Breakers. The SUS A & B switchgear will be physically separated, have enhanced coordination/protection features incorporated, and will be converted from a Main-Tie-Main to a Main-Tie-Tie-Main configuration. Additionally, the Power Control and Monitoring System (PCMS) and Power Quality Monitoring System (PQMS) will be extended to Missile Field 2. THIS IS A SOURCES SOUGHT OPEN TO ALL QUALIFIED PRIME CONTRACTOR FIRMS (Large and Small Businesses under NAICS 237130). All interested firms are encouraged to respond to this announcement no later than October 16 2024, by 2:00 PM Alaska Standard Time, by submitting all requested documentation listed below via email to Brittney.morrison@usace.army.mil and michelle.nelsen@usace.army.mil. Interested prime contractor firms are encouraged to submit a capabilities package (not exceeding 5 pages) demonstrating their ability to perform the work described above. Packages should include the following information regarding their company: 1. Company Name, Address, UEI Number, Cage Code, Business Size under the applicable NAICS above, and Point of Contact information including email and phone number. 2. Large or Small Business status under the applicable NAICS above, and type of small business (8a, HUBZone, Service-Disabled Veteran-Owned, Women-Owned, etc.) 3. Firm’s single project bonding capability/limit. 4. Demonstration of the firm’s experience as a prime contractor on projects of similar size, type, and complexity with the past ten years. List actual projects completed and include project title, location, and a brief description of the project including dollar amount, and work that was self-performed. 5. Your company’s intent to bid/propose on this project as a prime contractor. Interested parties are invited to submit a response to this Sources Sought by the response time stated above. Please submit all documentation by email in PDF format. Responses received after this time and date may not be reviewed.","origin":"extract"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"W911KB25R0019","place_of_performance":{"city":{"name":"Fort Greely"},"state":{"code":"AK"},"country":{"code":"USA"}},"product_service_code":"Y1BF"},{"dates":{"posted":"2024-10-08","response_deadline":{"raw":"2024-10-16T14:00:00-08:00","utc":"2024-10-16T22:00:00Z","date":"2024-10-16","time":"14:00:00","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/2bcaee9d9c0b47a8b65fd59b23c098ef/view"},"naics":{"codes":["237130"],"primary":"237130"},"title":"FTG257 MF2 Power Redundancy","agency":{"office":{"code":"W911KB","name":"W2SN ENDIST ALASKA"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"99506-0898","city":"ANCHORAGE","state":"AK","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-10-31","archive_type":"auto15"},"contacts":[{"name":"Brittney Morrison","role":"primary","email":"brittney.morrison@usace.army.mil"},{"name":"Michelle Nelsen","role":"secondary","email":"michelle.nelsen@usace.army.mil","phone":"9077532527"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"2bcaee9d9c0b47a8b65fd59b23c098ef","provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T19:12:38.374141Z","row_sha256":"44931339bb7bdb41225da8159512755356a5a42357cd22eee00e19126c8a126a","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-09-16T19:12:38.374141Z","first_seen_at":"2026-09-16T19:12:38.374141Z"},"description":{"text":"Project Name: FTG257 Missile Field 2 Power Redundancy Notice ID: W911KB25R0019 THIS IS A SOURCES SOUGHT NOTICE ONLY. PROPOSALS AND BIDS WILL NOT BE ACCEPTED FOR THIS NOTICE. THIS IS NOT A PRE-SOLICITATION. The Alaska District of the U.S. Army Corps of Engineers is conducting market research to facilitate a determination of acquisition strategy prior to releasing a solicitation for this anticipated project. The determination of acquisition strategy lies solely with the Government and will be based on market research and information available to the Government from other sources. Please note that this Sources Sought is for information only and does not constitute a solicitation for competitive proposals/bids and is not to be construed as a commitment by the Government. However, all interested parties who believe they can meet the requirement are invited to submit information describing their capability to provide the required services. The intent of this Sources Sought is to solicit interest from qualified firms with a primary North American Industrial Classification System (NAICS) code of 237130, Power and communication line and related structures construction which has a size standard of $45.0 million for a potential acquisition. The magnitude of this project is between $5M and $10M. DESCRIPTION OF WORK: The purpose of the project is to provide electrical power redundancy to the Missile Field 2 silo interface vaults by adding Automatic Transfer Switches and Main Lug Only distribution panels with Molded Case Circuit Breakers. The SUS A & B switchgear will be physically separated, have enhanced coordination/protection features incorporated, and will be converted from a Main-Tie-Main to a Main-Tie-Tie-Main configuration. Additionally, the Power Control and Monitoring System (PCMS) and Power Quality Monitoring System (PQMS) will be extended to Missile Field 2. THIS IS A SOURCES SOUGHT OPEN TO ALL QUALIFIED PRIME CONTRACTOR FIRMS (Large and Small Businesses under NAICS 237130). All interested firms are encouraged to respond to this announcement no later than October 16 2024, by 2:00 PM Alaska Standard Time, by submitting all requested documentation listed below via email to Brittney.morrison@usace.army.mil and michelle.nelsen@usace.army.mil. Interested prime contractor firms are encouraged to submit a capabilities package (not exceeding 5 pages) demonstrating their ability to perform the work described above. Packages should include the following information regarding their company: 1. Company Name, Address, UEI Number, Cage Code, Business Size under the applicable NAICS above, and Point of Contact information including email and phone number. 2. Large or Small Business status under the applicable NAICS above, and type of small business (8a, HUBZone, Service-Disabled Veteran-Owned, Women-Owned, etc.) 3. Firm’s single project bonding capability/limit. 4. Demonstration of the firm’s experience as a prime contractor on projects of similar size, type, and complexity with the past ten years. List actual projects completed and include project title, location, and a brief description of the project including dollar amount, and work that was self-performed. 5. Your company’s intent to bid/propose on this project as a prime contractor. Interested parties are invited to submit a response to this Sources Sought by the response time stated above. Please submit all documentation by email in PDF format. Responses received after this time and date may not be reviewed.","origin":"extract"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"W911KB25R0019","place_of_performance":{"city":{"name":"Fort Greely"},"state":{"code":"AK"},"country":{"code":"USA"}},"product_service_code":"Y1BF"},{"dates":{"posted":"2025-01-28","response_deadline":{"raw":"2025-02-12T15:00:00-09:00","utc":"2025-02-13T00:00:00Z","date":"2025-02-12","time":"15:00:00","utc_offset_seconds":-32400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/92c8a52826114abb8c068bef133f6df3/view"},"naics":{"codes":["237130"],"primary":"237130"},"title":"FTG257 Missile Field 2 Power Redundancy, Fort Greely, Alaska","agency":{"office":{"code":"W911KB","name":"W2SN ENDIST ALASKA"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"99506-0898","city":"ANCHORAGE","state":"AK","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2025-02-27","archive_type":"auto15"},"contacts":[{"name":"Brittney Morrison","role":"primary","email":"brittney.morrison@usace.army.mil"},{"name":"Michelle Nelsen","role":"secondary","email":"michelle.nelsen@usace.army.mil","phone":"9077532527"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"92c8a52826114abb8c068bef133f6df3","set_aside":{"code":"8A","label":"8(a) Set-Aside (FAR 19.8)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"eddf96281a733bccf6552bc2832c395e01a1b0389fb6cbd0937a541e0a714f8d","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-09-16T17:45:50.850439Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"text":"Presolicitation Notice TITLE: FTG257 Missile Field 2 Power Redundancy, Fort Greely, Alaska Identify set aside type PSC Code: Y1BF – Construction of Missile System Facilities NAICS Code: 237130 – Power and Communication Line and Related Structures Construction Solicitation Number: W911KB25R0019 Description: This is a pre-solicitation notice for a 8(a) small business set aside Request for Proposal (RFP) to provide electrical power redundancy to the Missile Field 2 silo interface vaults by adding Automatic Transfer Switches and Main Lug Only distribution panels with Molded Case Circuit Breakers. The SUS A & B switchgear will be physically separated, have enhanced coordination/protection features incorporated, and will be converted from a Main-Tie-Main to a Main-Tie-Tie-Main configuration. Additionally, the Power Control and Monitoring System (PCMS) and Power Quality Monitoring System (PQMS) will be extended to Missile Field 2.THIS IS A SOURCES SOUGHT OPEN TO.The estimated dollar magnitude of this project is anticipated between $1,000,000 and $5,000,000. The performance period will be approximately 630 calendar days. The procurement will be conducted using source selection procedures and the award will be based on best value tradeoff source selection procedures, considering the price and non-price factors cited in this announcement and the solicitation. All Offerors must be registered in the System for Award Management (SAM) (https://www.sam.gov/SAM/). Joint ventures must be registered in SAM as the joint venture. Offerors are advised to begin this process when they prepare their proposal in order to ensure this registration is in place should they be selected for the award. Lack of registration in the SAM database will make an Offeror ineligible for award. Anticipated NTP: 09 May 2025 with a 630 calendar-day period of performance; the Davis Bacon Act will apply. (1) PROJECT INFORMATION: Provide electrical power redundancy to the Missile Field 2 silo interface vaults by adding Automatic Transfer Switches and Main Lug Only distribution panels with Molded Case Circuit Breakers at Fort Greely, Alaska. (2) SELECTION CRITERIA: Evaluation criteria to be listed in the solicitation are anticipated to be: Factor 1 – Past Performance (Confidence Assessment) Factor 2 – Technical Approach Factor 3 – Summary Milestone Schedule Factor 4 – Price and Pro Forma Information (3) OBTAINING THE SOLICITATION: The solicitation for this project will be provided in electronic format only and is currently scheduled to be available for download on or about 19 February 2025 at the PIEE Solicitation Module website at https://piee.eb.mil/sol/xhtml/unauth/index.xhtml via Solicitation number (W911KB25R0019). Any future amendments to the solicitation will also be available for download from this website. All responsible sources may submit an offer which will be considered by the agency. All notifications of changes to this solicitation shall be made through the internet only. It is the Offeror’s responsibility to check for any posted changes to this solicitation. NOTE: Electronic proposal submissions will only be accepted via the PIEE Solicitation Module website at: https://piee.eb.mil/sol/xhtml/unauth/index.xhtml. IN ORDER TO SUBMIT A PROPOSAL, VENDORS MUST REGISTER IN THE PIEE SYSTEM AND MUST HAVE A PROPOSAL MANAGER ROLE ESTABLISHED. ADDITIONAL INFORMATION REGARDING PROPOSAL MANAGER, PROPOSAL MANAGER FUNCTIONS AND POSTING OFFERS CAN BE FOUD AT https//pieetraining.eb.mil/wbt/xhtml/wbt/sol/solicitation/proposals.xhtml","origin":"extract"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"W911KB25R0019","place_of_performance":{"zip":"99731","city":{"name":"Fort Greely"},"state":{"code":"AK"},"country":{"code":"USA"}},"product_service_code":"Y1BF"},{"dates":{"posted":"2025-03-19","response_deadline":{"raw":"2025-04-22T14:00:00-08:00","utc":"2025-04-22T22:00:00Z","date":"2025-04-22","time":"14:00:00","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/29fe77495f0143a9a27b3787e6fe3431/view"},"naics":{"codes":["237130"],"primary":"237130"},"title":"FTG257 MISSILE FIELD 2 POWER REDUNDANCY","agency":{"office":{"code":"W911KB","name":"W2SN ENDIST ALASKA"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"99506-0898","city":"ANCHORAGE","state":"AK","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2026-03-19","archive_type":"auto_custom"},"contacts":[{"name":"Brittney Morrison","role":"primary","email":"Brittney.morrison@usace.army.mil","phone":"9077532894"},{"name":"Michelle Nelsen","role":"secondary","email":"michelle.nelsen@usace.army.mil","phone":"9077532527"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"29fe77495f0143a9a27b3787e6fe3431","set_aside":{"code":"8A","label":"8(a) Set-Aside (FAR 19.8)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"290b86f40143b94aadaebfcc0bab45442a1ae12ee8a184aa655142b568ed4cc8","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-09-16T17:45:50.850439Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"text":"This is a Request for Proposal (RFP) for a standalone 8(a) competitive contract. The purpose of the project is to provide electrical power redundancy to the Missile Field 2 silo interface vaults by adding Automatic Transfer Switches and Main Lug Only distribution panels with Molded Case Circuit Breakers. The SUS A and B switchgear will be physically separated, have enhanced coordination/protection features incorporated, and will be converted from a Main-Tie-Main to a Main Tie-Tie-Main configuration. Additionally, the Power Control and Monitoring System (PCMS) and Power Quality Monitoring System (PQMS) will be extended to Missile Field 2.TO RECEIVE A COPY OF THE SOLICITATION PLEASE EMAIL BRITTNEY MORRISON AT BRITTNEY.MORRISON@USACE.ARMY.MIL AND MICHELLE NELSEN AT MICHELLE.NELSEN@USACE.ARMY.MIL","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"W911KB25R0019","product_service_code":"Y1BF"},{"dates":{"posted":"2025-03-28","response_deadline":{"raw":"2025-04-22T14:00:00-08:00","utc":"2025-04-22T22:00:00Z","date":"2025-04-22","time":"14:00:00","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/df69891d30b649d882d3f75538c398ec/view"},"naics":{"codes":["237130"],"primary":"237130"},"title":"FTG257 MISSILE FIELD 2 POWER REDUNDANCY","agency":{"office":{"code":"W911KB","name":"W2SN ENDIST ALASKA"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"99506-0898","city":"ANCHORAGE","state":"AK","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2026-03-28","archive_type":"auto_custom"},"contacts":[{"name":"Brittney Morrison","role":"primary","email":"Brittney.morrison@usace.army.mil","phone":"9077532894"},{"name":"Michelle Nelsen","role":"secondary","email":"michelle.nelsen@usace.army.mil","phone":"9077532527"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"df69891d30b649d882d3f75538c398ec","set_aside":{"code":"8A","label":"8(a) Set-Aside (FAR 19.8)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"243ddb6dc89b4939213bf8ef21e3f2f05b8a5b9dcf1a53a6cbca1302fd618198","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-09-16T17:45:50.850439Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"text":"This is a Request for Proposal (RFP) for a standalone 8(a) competitive contract. The purpose of the project is to provide electrical power redundancy to the Missile Field 2 silo interface vaults by adding Automatic Transfer Switches and Main Lug Only distribution panels with Molded Case Circuit Breakers. The SUS A and B switchgear will be physically separated, have enhanced coordination/protection features incorporated, and will be converted from a Main-Tie-Main to a Main Tie-Tie-Main configuration. Additionally, the Power Control and Monitoring System (PCMS) and Power Quality Monitoring System (PQMS) will be extended to Missile Field 2.TO RECEIVE A COPY OF THE SOLICITATION PLEASE EMAIL BRITTNEY MORRISON AT BRITTNEY.MORRISON@USACE.ARMY.MIL AND MICHELLE NELSEN AT MICHELLE.NELSEN@USACE.ARMY.MIL","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"W911KB25R0019","product_service_code":"Y1BF"},{"dates":{"posted":"2025-04-29","response_deadline":{"raw":"2025-05-06T14:00:00-08:00","utc":"2025-05-06T22:00:00Z","date":"2025-05-06","time":"14:00:00","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/2a3c64561f9d4fc5850a3d3d9f7a2b65/view"},"naics":{"codes":["237130"],"primary":"237130"},"title":"FTG257 MISSILE FIELD 2 POWER REDUNDANCY","agency":{"office":{"code":"W911KB","name":"W2SN ENDIST ALASKA"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"99506-0898","city":"ANCHORAGE","state":"AK","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2026-04-03","archive_type":"auto_custom"},"contacts":[{"name":"Brittney Morrison","role":"primary","email":"Brittney.morrison@usace.army.mil","phone":"9077532894"},{"name":"Michelle Nelsen","role":"secondary","email":"michelle.nelsen@usace.army.mil","phone":"9077532527"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"2a3c64561f9d4fc5850a3d3d9f7a2b65","set_aside":{"code":"8A","label":"8(a) Set-Aside (FAR 19.8)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"fe9ef0130c09e2af2ceb1738fc80f633998c3fd18b6a398265a5735727adf236","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-09-16T17:45:50.850439Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"text":"This is a Request for Proposal (RFP) for a standalone 8(a) competitive contract. The purpose of the project is to provide electrical power redundancy to the Missile Field 2 silo interface vaults by adding Automatic Transfer Switches and Main Lug Only distribution panels with Molded Case Circuit Breakers. The SUS A and B switchgear will be physically separated, have enhanced coordination/protection features incorporated, and will be converted from a Main-Tie-Main to a Main Tie-Tie-Main configuration. Additionally, the Power Control and Monitoring System (PCMS) and Power Quality Monitoring System (PQMS) will be extended to Missile Field 2.TO RECEIVE A COPY OF THE SOLICITATION PLEASE EMAIL BRITTNEY MORRISON AT BRITTNEY.MORRISON@USACE.ARMY.MIL AND MICHELLE NELSEN AT MICHELLE.NELSEN@USACE.ARMY.MIL","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"W911KB25R0019","product_service_code":"Y1BF"},{"dates":{"posted":"2025-05-01","response_deadline":{"raw":"2025-05-06T14:00:00-08:00","utc":"2025-05-06T22:00:00Z","date":"2025-05-06","time":"14:00:00","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/66452e76fbf44e11a07c9b3650be4a88/view"},"naics":{"codes":["237130"],"primary":"237130"},"title":"FTG257 MISSILE FIELD 2 POWER REDUNDANCY","agency":{"office":{"code":"W911KB","name":"W2SN ENDIST ALASKA"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"99506-0898","city":"ANCHORAGE","state":"AK","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2026-05-01","archive_type":"auto_custom"},"contacts":[{"name":"Brittney Morrison","role":"primary","email":"Brittney.morrison@usace.army.mil","phone":"9077532894"},{"name":"Michelle Nelsen","role":"secondary","email":"michelle.nelsen@usace.army.mil","phone":"9077532527"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"66452e76fbf44e11a07c9b3650be4a88","set_aside":{"code":"8A","label":"8(a) Set-Aside (FAR 19.8)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"86fadec69e142ed2d904126c128d39a0eb3506392cf297073c3aa983a4c4e3cf","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-09-16T17:45:50.850439Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"text":"This is a Request for Proposal (RFP) for a standalone 8(a) competitive contract. The purpose of the project is to provide electrical power redundancy to the Missile Field 2 silo interface vaults by adding Automatic Transfer Switches and Main Lug Only distribution panels with Molded Case Circuit Breakers. The SUS A and B switchgear will be physically separated, have enhanced coordination/protection features incorporated, and will be converted from a Main-Tie-Main to a Main Tie-Tie-Main configuration. Additionally, the Power Control and Monitoring System (PCMS) and Power Quality Monitoring System (PQMS) will be extended to Missile Field 2.TO RECEIVE A COPY OF THE SOLICITATION PLEASE EMAIL BRITTNEY MORRISON AT BRITTNEY.MORRISON@USACE.ARMY.MIL AND MICHELLE NELSEN AT MICHELLE.NELSEN@USACE.ARMY.MIL","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"W911KB25R0019","product_service_code":"Y1BF"},{"dates":{"posted":"2025-05-01","response_deadline":{"raw":"2025-05-06T14:00:00-08:00","utc":"2025-05-06T22:00:00Z","date":"2025-05-06","time":"14:00:00","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/f8f0129097d540588c28b13d2753b21e/view"},"naics":{"codes":["237130"],"primary":"237130"},"title":"FTG257 MISSILE FIELD 2 POWER REDUNDANCY","agency":{"office":{"code":"W911KB","name":"W2SN ENDIST ALASKA"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"99506-0898","city":"ANCHORAGE","state":"AK","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2026-05-01","archive_type":"auto_custom"},"contacts":[{"name":"Brittney Morrison","role":"primary","email":"Brittney.morrison@usace.army.mil","phone":"9077532894"},{"name":"Michelle Nelsen","role":"secondary","email":"michelle.nelsen@usace.army.mil","phone":"9077532527"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"f8f0129097d540588c28b13d2753b21e","set_aside":{"code":"8A","label":"8(a) Set-Aside (FAR 19.8)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"8ce55313c6827b1bbf1730caad44e631076675db33e2986d3418155470b00754","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-09-16T17:45:50.850439Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"text":"This is a Request for Proposal (RFP) for a standalone 8(a) competitive contract. The purpose of the project is to provide electrical power redundancy to the Missile Field 2 silo interface vaults by adding Automatic Transfer Switches and Main Lug Only distribution panels with Molded Case Circuit Breakers. The SUS A and B switchgear will be physically separated, have enhanced coordination/protection features incorporated, and will be converted from a Main-Tie-Main to a Main Tie-Tie-Main configuration. Additionally, the Power Control and Monitoring System (PCMS) and Power Quality Monitoring System (PQMS) will be extended to Missile Field 2.TO RECEIVE A COPY OF THE SOLICITATION PLEASE EMAIL BRITTNEY MORRISON AT BRITTNEY.MORRISON@USACE.ARMY.MIL AND MICHELLE NELSEN AT MICHELLE.NELSEN@USACE.ARMY.MIL","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"W911KB25R0019","product_service_code":"Y1BF"},{"dates":{"posted":"2025-05-06","response_deadline":{"raw":"2025-05-27T14:00:00-08:00","utc":"2025-05-27T22:00:00Z","date":"2025-05-27","time":"14:00:00","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/679f7c49adbe482285dadf45e8101b13/view"},"naics":{"codes":["237130"],"primary":"237130"},"title":"FTG257 MISSILE FIELD 2 POWER REDUNDANCY","agency":{"office":{"code":"W911KB","name":"W2SN ENDIST ALASKA"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"99506-0898","city":"ANCHORAGE","state":"AK","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2026-05-06","archive_type":"auto_custom"},"contacts":[{"name":"Brittney Morrison","role":"primary","email":"Brittney.morrison@usace.army.mil","phone":"9077532894"},{"name":"Michelle Nelsen","role":"secondary","email":"michelle.nelsen@usace.army.mil","phone":"9077532527"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"679f7c49adbe482285dadf45e8101b13","set_aside":{"code":"8A","label":"8(a) Set-Aside (FAR 19.8)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"f50f0c71e20ff435623a69abd65f2c2b475d034f8b488fbd8aa7f1e81e62bae6","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-09-16T17:45:50.850439Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"text":"This is a Request for Proposal (RFP) for a standalone 8(a) competitive contract. The purpose of the project is to provide electrical power redundancy to the Missile Field 2 silo interface vaults by adding Automatic Transfer Switches and Main Lug Only distribution panels with Molded Case Circuit Breakers. The SUS A and B switchgear will be physically separated, have enhanced coordination/protection features incorporated, and will be converted from a Main-Tie-Main to a Main Tie-Tie-Main configuration. Additionally, the Power Control and Monitoring System (PCMS) and Power Quality Monitoring System (PQMS) will be extended to Missile Field 2.TO RECEIVE A COPY OF THE SOLICITATION PLEASE EMAIL BRITTNEY MORRISON AT BRITTNEY.MORRISON@USACE.ARMY.MIL AND MICHELLE NELSEN AT MICHELLE.NELSEN@USACE.ARMY.MIL","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"W911KB25R0019","product_service_code":"Y1BF"},{"dates":{"posted":"2025-05-06","response_deadline":{"raw":"2025-05-27T14:00:00-08:00","utc":"2025-05-27T22:00:00Z","date":"2025-05-27","time":"14:00:00","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/a7f5a5f9620649708f1448dc75b9f428/view"},"naics":{"codes":["237130"],"primary":"237130"},"title":"FTG257 MISSILE FIELD 2 POWER REDUNDANCY","agency":{"office":{"code":"W911KB","name":"W2SN ENDIST ALASKA"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"99506-0898","city":"ANCHORAGE","state":"AK","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2026-05-06","archive_type":"auto_custom"},"contacts":[{"name":"Brittney Morrison","role":"primary","email":"Brittney.morrison@usace.army.mil","phone":"9077532894"},{"name":"Michelle Nelsen","role":"secondary","email":"michelle.nelsen@usace.army.mil","phone":"9077532527"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"a7f5a5f9620649708f1448dc75b9f428","set_aside":{"code":"8A","label":"8(a) Set-Aside (FAR 19.8)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"6047ccd469cb31962b60afd0dda25166cc22d3c99b0713faacd882092af6106e","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-09-16T17:45:50.850439Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"text":"This is a Request for Proposal (RFP) for a standalone 8(a) competitive contract. The purpose of the project is to provide electrical power redundancy to the Missile Field 2 silo interface vaults by adding Automatic Transfer Switches and Main Lug Only distribution panels with Molded Case Circuit Breakers. The SUS A and B switchgear will be physically separated, have enhanced coordination/protection features incorporated, and will be converted from a Main-Tie-Main to a Main Tie-Tie-Main configuration. Additionally, the Power Control and Monitoring System (PCMS) and Power Quality Monitoring System (PQMS) will be extended to Missile Field 2.TO RECEIVE A COPY OF THE SOLICITATION PLEASE EMAIL BRITTNEY MORRISON AT BRITTNEY.MORRISON@USACE.ARMY.MIL AND MICHELLE NELSEN AT MICHELLE.NELSEN@USACE.ARMY.MIL","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"W911KB25R0019","product_service_code":"Y1BF"},{"dates":{"posted":"2025-05-13","response_deadline":{"raw":"2025-05-27T14:00:00-08:00","utc":"2025-05-27T22:00:00Z","date":"2025-05-27","time":"14:00:00","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/3e416ca522ae4eb6976efaac8fcfb3d0/view"},"naics":{"codes":["237130"],"primary":"237130"},"title":"FTG257 MISSILE FIELD 2 POWER REDUNDANCY","agency":{"office":{"code":"W911KB","name":"W2SN ENDIST ALASKA"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"99506-0898","city":"ANCHORAGE","state":"AK","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2026-05-13","archive_type":"auto_custom"},"contacts":[{"name":"Brittney Morrison","role":"primary","email":"Brittney.morrison@usace.army.mil","phone":"9077532894"},{"name":"Michelle Nelsen","role":"secondary","email":"michelle.nelsen@usace.army.mil","phone":"9077532527"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"3e416ca522ae4eb6976efaac8fcfb3d0","set_aside":{"code":"8A","label":"8(a) Set-Aside (FAR 19.8)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"38d6a68252c679deb7578eb6c7eb667a15109fcc07297d1118840d81ca8b77af","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-09-16T17:45:50.850439Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"text":"This is a Request for Proposal (RFP) for a standalone 8(a) competitive contract. The purpose of the project is to provide electrical power redundancy to the Missile Field 2 silo interface vaults by adding Automatic Transfer Switches and Main Lug Only distribution panels with Molded Case Circuit Breakers. The SUS A and B switchgear will be physically separated, have enhanced coordination/protection features incorporated, and will be converted from a Main-Tie-Main to a Main Tie-Tie-Main configuration. Additionally, the Power Control and Monitoring System (PCMS) and Power Quality Monitoring System (PQMS) will be extended to Missile Field 2.TO RECEIVE A COPY OF THE SOLICITATION AND AMENDMENTS PLEASE EMAIL BRITTNEY MORRISON AT BRITTNEY.MORRISON@USACE.ARMY.MIL AND MICHELLE NELSEN AT MICHELLE.NELSEN@USACE.ARMY.MIL","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"W911KB25R0019","product_service_code":"Y1BF"},{"dates":{"posted":"2025-05-13","response_deadline":{"raw":"2025-05-27T14:00:00-08:00","utc":"2025-05-27T22:00:00Z","date":"2025-05-27","time":"14:00:00","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/dfa371c0983c470b8c73a7ac050a3738/view"},"naics":{"codes":["237130"],"primary":"237130"},"title":"FTG257 MISSILE FIELD 2 POWER REDUNDANCY","agency":{"office":{"code":"W911KB","name":"W2SN ENDIST ALASKA"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"99506-0898","city":"ANCHORAGE","state":"AK","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2026-05-13","archive_type":"auto_custom"},"contacts":[{"name":"Brittney Morrison","role":"primary","email":"Brittney.morrison@usace.army.mil","phone":"9077532894"},{"name":"Michelle Nelsen","role":"secondary","email":"michelle.nelsen@usace.army.mil","phone":"9077532527"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"dfa371c0983c470b8c73a7ac050a3738","set_aside":{"code":"8A","label":"8(a) Set-Aside (FAR 19.8)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"59a1b3f88215478604602b3727f73d22831464bd5cea7127d8eee2ff862f7bbb","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-09-16T17:45:50.850439Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"text":"This is a Request for Proposal (RFP) for a standalone 8(a) competitive contract. The purpose of the project is to provide electrical power redundancy to the Missile Field 2 silo interface vaults by adding Automatic Transfer Switches and Main Lug Only distribution panels with Molded Case Circuit Breakers. The SUS A and B switchgear will be physically separated, have enhanced coordination/protection features incorporated, and will be converted from a Main-Tie-Main to a Main Tie-Tie-Main configuration. Additionally, the Power Control and Monitoring System (PCMS) and Power Quality Monitoring System (PQMS) will be extended to Missile Field 2.TO RECEIVE A COPY OF THE SOLICITATION AND AMENDMENTS PLEASE EMAIL BRITTNEY MORRISON AT BRITTNEY.MORRISON@USACE.ARMY.MIL AND MICHELLE NELSEN AT MICHELLE.NELSEN@USACE.ARMY.MIL","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"W911KB25R0019","product_service_code":"Y1BF"},{"dates":{"posted":"2025-05-23","response_deadline":{"raw":"2025-05-27T14:00:00-08:00","utc":"2025-05-27T22:00:00Z","date":"2025-05-27","time":"14:00:00","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/06cdb5428af0497aa2ec7d07134fca3a/view"},"naics":{"codes":["237130"],"primary":"237130"},"title":"FTG257 MISSILE FIELD 2 POWER REDUNDANCY","agency":{"office":{"code":"W911KB","name":"W2SN ENDIST ALASKA"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"99506-0898","city":"ANCHORAGE","state":"AK","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2026-05-23","archive_type":"auto_custom"},"contacts":[{"name":"Brittney Morrison","role":"primary","email":"Brittney.morrison@usace.army.mil","phone":"9077532894"},{"name":"Michelle Nelsen","role":"secondary","email":"michelle.nelsen@usace.army.mil","phone":"9077532527"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"06cdb5428af0497aa2ec7d07134fca3a","set_aside":{"code":"8A","label":"8(a) Set-Aside (FAR 19.8)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"d40137c1e27c2b010c65997a402e9758e4d9f97322aab9030f25bdadb05ea89d","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-09-16T17:45:50.850439Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"text":"This is a Request for Proposal (RFP) for a standalone 8(a) competitive contract. The purpose of the project is to provide electrical power redundancy to the Missile Field 2 silo interface vaults by adding Automatic Transfer Switches and Main Lug Only distribution panels with Molded Case Circuit Breakers. The SUS A and B switchgear will be physically separated, have enhanced coordination/protection features incorporated, and will be converted from a Main-Tie-Main to a Main Tie-Tie-Main configuration. Additionally, the Power Control and Monitoring System (PCMS) and Power Quality Monitoring System (PQMS) will be extended to Missile Field 2.TO RECEIVE A COPY OF THE SOLICITATION AND AMENDMENTS PLEASE EMAIL BRITTNEY MORRISON AT BRITTNEY.MORRISON@USACE.ARMY.MIL AND MICHELLE NELSEN AT MICHELLE.NELSEN@USACE.ARMY.MIL","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"W911KB25R0019","product_service_code":"Y1BF"},{"dates":{"posted":"2025-05-23","response_deadline":{"raw":"2025-05-27T14:00:00-08:00","utc":"2025-05-27T22:00:00Z","date":"2025-05-27","time":"14:00:00","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/20fde15f83054f73b9bce5131fbb434c/view"},"naics":{"codes":["237130"],"primary":"237130"},"title":"FTG257 MISSILE FIELD 2 POWER REDUNDANCY","agency":{"office":{"code":"W911KB","name":"W2SN ENDIST ALASKA"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"99506-0898","city":"ANCHORAGE","state":"AK","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2026-05-23","archive_type":"auto_custom"},"contacts":[{"name":"Brittney Morrison","role":"primary","email":"Brittney.morrison@usace.army.mil","phone":"9077532894"},{"name":"Michelle Nelsen","role":"secondary","email":"michelle.nelsen@usace.army.mil","phone":"9077532527"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"20fde15f83054f73b9bce5131fbb434c","set_aside":{"code":"8A","label":"8(a) Set-Aside (FAR 19.8)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"6a3ae7b19601d1205a43c4d21cc0029c0f04ccc8f728d0aeb86f87b717827ae6","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-09-16T17:45:50.850439Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"text":"This is a Request for Proposal (RFP) for a standalone 8(a) competitive contract. The purpose of the project is to provide electrical power redundancy to the Missile Field 2 silo interface vaults by adding Automatic Transfer Switches and Main Lug Only distribution panels with Molded Case Circuit Breakers. The SUS A and B switchgear will be physically separated, have enhanced coordination/protection features incorporated, and will be converted from a Main-Tie-Main to a Main Tie-Tie-Main configuration. Additionally, the Power Control and Monitoring System (PCMS) and Power Quality Monitoring System (PQMS) will be extended to Missile Field 2.TO RECEIVE A COPY OF THE SOLICITATION AND AMENDMENTS PLEASE EMAIL BRITTNEY MORRISON AT BRITTNEY.MORRISON@USACE.ARMY.MIL AND MICHELLE NELSEN AT MICHELLE.NELSEN@USACE.ARMY.MIL","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"W911KB25R0019","product_service_code":"Y1BF"},{"dates":{"posted":"2025-07-14","response_deadline":{"raw":"2025-07-16T14:00:00-08:00","utc":"2025-07-16T22:00:00Z","date":"2025-07-16","time":"14:00:00","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/16114f8aedab4f799b63f88189f448b3/view"},"naics":{"codes":["237130"],"primary":"237130"},"title":"FTG257 MISSILE FIELD 2 POWER REDUNDANCY","agency":{"office":{"code":"W911KB","name":"W2SN ENDIST ALASKA"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"99506-0898","city":"ANCHORAGE","state":"AK","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2026-07-14","archive_type":"auto_custom"},"contacts":[{"name":"Brittney Morrison","role":"primary","email":"Brittney.morrison@usace.army.mil","phone":"9077532894"},{"name":"Michelle Nelsen","role":"secondary","email":"michelle.nelsen@usace.army.mil","phone":"9077532527"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"16114f8aedab4f799b63f88189f448b3","set_aside":{"code":"8A","label":"8(a) Set-Aside (FAR 19.8)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"b1e64dac86462c4e6ee39d5a08e5615b796244ae29aa4dae788bc95db0c45546","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-09-16T17:45:50.850439Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"text":"This is a Request for Proposal (RFP) for a standalone 8(a) competitive contract. The purpose of the project is to provide electrical power redundancy to the Missile Field 2 silo interface vaults by adding Automatic Transfer Switches and Main Lug Only distribution panels with Molded Case Circuit Breakers. The SUS A and B switchgear will be physically separated, have enhanced coordination/protection features incorporated, and will be converted from a Main-Tie-Main to a Main Tie-Tie-Main configuration. Additionally, the Power Control and Monitoring System (PCMS) and Power Quality Monitoring System (PQMS) will be extended to Missile Field 2.TO RECEIVE A COPY OF THE SOLICITATION AND AMENDMENTS PLEASE EMAIL BRITTNEY MORRISON AT BRITTNEY.MORRISON@USACE.ARMY.MIL AND MICHELLE NELSEN AT MICHELLE.NELSEN@USACE.ARMY.MIL","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"W911KB25R0019","product_service_code":"Y1BF"},{"dates":{"posted":"2025-07-14","response_deadline":{"raw":"2025-07-16T14:00:00-08:00","utc":"2025-07-16T22:00:00Z","date":"2025-07-16","time":"14:00:00","utc_offset_seconds":-28800}},"links":{"sam":"https://sam.gov/workspace/contract/opp/4c7583460e16426996c9954bcb3f6691/view"},"naics":{"codes":["237130"],"primary":"237130"},"title":"FTG257 MISSILE FIELD 2 POWER REDUNDANCY","agency":{"office":{"code":"W911KB","name":"W2SN ENDIST ALASKA"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"99506-0898","city":"ANCHORAGE","state":"AK","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2026-07-14","archive_type":"auto_custom"},"contacts":[{"name":"Brittney Morrison","role":"primary","email":"Brittney.morrison@usace.army.mil","phone":"9077532894"},{"name":"Michelle Nelsen","role":"secondary","email":"michelle.nelsen@usace.army.mil","phone":"9077532527"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"4c7583460e16426996c9954bcb3f6691","set_aside":{"code":"8A","label":"8(a) Set-Aside (FAR 19.8)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"825d9b977cabd1cd09af44f9d81c2ca49a676f22695edd56b30e510c29027795","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-09-16T17:45:50.850439Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"text":"This is a Request for Proposal (RFP) for a standalone 8(a) competitive contract. The purpose of the project is to provide electrical power redundancy to the Missile Field 2 silo interface vaults by adding Automatic Transfer Switches and Main Lug Only distribution panels with Molded Case Circuit Breakers. The SUS A and B switchgear will be physically separated, have enhanced coordination/protection features incorporated, and will be converted from a Main-Tie-Main to a Main Tie-Tie-Main configuration. Additionally, the Power Control and Monitoring System (PCMS) and Power Quality Monitoring System (PQMS) will be extended to Missile Field 2.TO RECEIVE A COPY OF THE SOLICITATION AND AMENDMENTS PLEASE EMAIL BRITTNEY MORRISON AT BRITTNEY.MORRISON@USACE.ARMY.MIL AND MICHELLE NELSEN AT MICHELLE.NELSEN@USACE.ARMY.MIL","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"W911KB25R0019","product_service_code":"Y1BF"}],"due_at":"2025-07-16T22:00:00Z","due_date":"2025-07-16","closes_at":"2025-07-16T22:00:00Z","awardable":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911KB","office_name":"W2SN ENDIST ALASKA","state":"AK","county":"02240","county_name":"Southeast Fairbanks Census Area","city":"0226100","city_name":"Fort Greely","country":"USA","winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z","principal_notice_id":"4c7583460e16426996c9954bcb3f6691","description":{"text":"This is a Request for Proposal (RFP) for a standalone 8(a) competitive contract. The purpose of the project is to provide electrical power redundancy to the Missile Field 2 silo interface vaults by adding Automatic Transfer Switches and Main Lug Only distribution panels with Molded Case Circuit Breakers. The SUS A and B switchgear will be physically separated, have enhanced coordination/protection features incorporated, and will be converted from a Main-Tie-Main to a Main Tie-Tie-Main configuration. Additionally, the Power Control and Monitoring System (PCMS) and Power Quality Monitoring System (PQMS) will be extended to Missile Field 2.TO RECEIVE A COPY OF THE SOLICITATION AND AMENDMENTS PLEASE EMAIL BRITTNEY MORRISON AT BRITTNEY.MORRISON@USACE.ARMY.MIL AND MICHELLE NELSEN AT MICHELLE.NELSEN@USACE.ARMY.MIL","html":null,"origin":"extract"},"contacts":[{"name":"Brittney Morrison","role":"primary","email":"Brittney.morrison@usace.army.mil","phone":"9077532894"},{"name":"Michelle Nelsen","role":"secondary","email":"michelle.nelsen@usace.army.mil","phone":"9077532527"}],"place_of_performance":null,"office_address":{"zip":"99506-0898","city":"ANCHORAGE","state":"AK","country":"USA"},"naics_codes":["237130"],"award":null,"attachments":[],"awards":[],"related":[{"key":"W911KB26RA0301","latest_notice_id":"33b519d40d6440418381c54d1b7c2e13","title":"SOURCES SOUGHT: JBE 089 CRH SIMULATOR FACILITY BUILDING (BRAND NAME REQUIREMENTS)","solicitation_number":"W911KB26RA030-1","notice_type":"r","first_type":"r","first_posted":"2026-09-15","last_posted":"2026-09-15","notices":1,"due_at":"2026-09-29T22:00:00Z","due_date":"2026-09-29","closes_at":"2026-09-29T22:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911KB","office_name":"W2SN ENDIST ALASKA","naics":"334290","psc":null,"set_aside":null,"state":"AK","county":"02020","county_name":"Anchorage Municipality","city":null,"city_name":null,"country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-17T06:28:38.602097Z"},{"key":"W911KB25R0032","latest_notice_id":"36f58ccc19e04752854dc01f0af35015","title":"FTG247 Replace UPS at IDT1, Fort Greely, Alaska","solicitation_number":"W911KB25R0032","notice_type":"p","first_type":"r","first_posted":"2024-12-04","last_posted":"2025-04-03","notices":3,"due_at":"2026-12-13T00:00:00Z","due_date":"2026-12-12","closes_at":"2026-12-13T00:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W911KB","office_name":"W2SN ENDIST ALASKA","naics":"237130","psc":"Y1BF","set_aside":"SBA","state":"AK","county":"02240","county_name":"Southeast Fairbanks Census Area","city":"0226100","city_name":"Fort Greely","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"}]}