{"canonical":"https://abierto.us/opportunities/w81k0026qa200","key":"W81K0026QA200","url":"https://abierto.us/opportunities/w81k0026qa200","title":"L&D Surgical Lights","solicitation_number":"W81K0026QA200","notice_type":"o","open":false,"response_deadline":"2026-06-22T17:00:00Z","first_posted":"2026-06-08","last_posted":"2026-06-16","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE ARMY","office":"W40M MRC0 WEST","naics":"339113","psc":"6530","set_aside":"SDVOSBS","place_state":"CO","place_county":"08041","place_county_name":"El Paso County","place_city":"0816000","place_city_name":"Colorado Springs","winner":null,"award_amount":null,"publications":[{"notice_id":"aa23ee2637194278a0469facf7971a41","title":"L&D Surgical Lights","solicitation_number":"W81K0026QA200","notice_type":"o","base_type":"o","posted":"2026-06-08","posted_at":null,"due_at":"2026-06-15T17:00:00Z","due_date":"2026-06-15","cancelled":null,"archived":null,"archive_date":"2026-06-30","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/aa23ee2637194278a0469facf7971a41/view","enriched":false,"history":[]},{"notice_id":"19c74de0515d4f489d4780729964b972","title":"L&D Surgical Lights","solicitation_number":"W81K0026QA200","notice_type":"o","base_type":"o","posted":"2026-06-12","posted_at":null,"due_at":"2026-06-22T17:00:00Z","due_date":"2026-06-22","cancelled":null,"archived":null,"archive_date":"2026-07-07","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/19c74de0515d4f489d4780729964b972/view","enriched":false,"history":[]},{"notice_id":"f5b1b23993204a9a99b7ad6adfd7c097","title":"L&D Surgical Lights","solicitation_number":"W81K0026QA200","notice_type":"o","base_type":"o","posted":"2026-06-16","posted_at":null,"due_at":"2026-06-22T17:00:00Z","due_date":"2026-06-22","cancelled":null,"archived":null,"archive_date":"2026-07-07","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/f5b1b23993204a9a99b7ad6adfd7c097/view","enriched":false,"history":[]}],"latest_notice_id":"f5b1b23993204a9a99b7ad6adfd7c097","first_type":"o","notices":[{"dates":{"posted":"2026-06-08","response_deadline":{"raw":"2026-06-15T11:00:00-06:00","utc":"2026-06-15T17:00:00Z","date":"2026-06-15","time":"11:00:00","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/aa23ee2637194278a0469facf7971a41/view"},"naics":{"codes":["339113"],"primary":"339113"},"title":"L&D Surgical Lights","agency":{"office":{"code":"W81K00","name":"W40M MRC0 WEST"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"78234-4504","city":"JBSA FT SAM HOUSTON","state":"TX","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2026-06-30","archive_type":"auto15"},"contacts":[{"name":"Joseph Flores","role":"primary","email":"joseph.a.flores.civ@health.mil"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"aa23ee2637194278a0469facf7971a41","set_aside":{"code":"SDVOSBS","label":"Service-Disabled Veteran-Owned Small Business Sole Source (FAR 19.14)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"b5edad3083033a6089111cb503fd420d1fbc260d328bfc59a54b8097186492de","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-16T16:22:53.920682Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"text":"Clinical Salient Requirements: ?System must allow clinicians to adjust the focal point and working distance directlyfrom the center sterile handle without moving the light head or leaving the sterilefield. ?The light head must utilize vertically segmented reflectors to capture upward-directed light and redirect it downward, creating a crisp, homogenous spot thatminimizes shadows. ?The system must offer dual selectable color temperatures (specifically 4100K softwhite and 4500K bright white) adjustable for specific procedure types. Technological Salient Requirements: Server Requirements: ?The lights must deliver a maximum intensity of 160,000 lux and offer light headdiameter options of 24 inches or 30 inches to fill the surgical cavity with seamlesslight. ?The lighting architecture must integrate a manual focus mode of high-intensity LEDscombined with a centrally positioned ring of fixed-focus LEDs. ?The lights must be explicitly compatible with and ready for integration with flat-screen displays, booms, and HD surgical cameras. System Requirement: ?The suspension and arm system must provide at least 110 degrees of vertical travelto allow steep downward positioning. ?All axes of the lighting fixture must feature 360-degree continuous rotation withouthard spots. ?The optical design must allow the fixtures to be placed further away from the patientwhile maintaining precise detail.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"W81K0026QA200","place_of_performance":{"zip":"80913","city":{"name":"Colorado Springs"},"state":{"code":"CO"},"country":{"code":"USA"}},"product_service_code":"1190"},{"dates":{"posted":"2026-06-12","response_deadline":{"raw":"2026-06-22T11:00:00-06:00","utc":"2026-06-22T17:00:00Z","date":"2026-06-22","time":"11:00:00","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/19c74de0515d4f489d4780729964b972/view"},"naics":{"codes":["339113"],"primary":"339113"},"title":"L&D Surgical Lights","agency":{"office":{"code":"W81K00","name":"W40M MRC0 WEST"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"78234-4504","city":"JBSA FT SAM HOUSTON","state":"TX","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2026-07-07","archive_type":"auto15"},"contacts":[{"name":"Joseph Flores","role":"primary","email":"joseph.a.flores.civ@health.mil"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"19c74de0515d4f489d4780729964b972","set_aside":{"code":"SDVOSBS","label":"Service-Disabled Veteran-Owned Small Business Sole Source (FAR 19.14)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"d47f2cf62a3b7bac19a80f2d1a605cb8ea9b51cf000bd6b49b495f3a14d1bc59","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-16T16:22:53.920682Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"text":"Clinical Salient Requirements: ?System must allow clinicians to adjust the focal point and working distance directlyfrom the center sterile handle without moving the light head or leaving the sterilefield. ?The light head must utilize vertically segmented reflectors to capture upward-directed light and redirect it downward, creating a crisp, homogenous spot thatminimizes shadows. ?The system must offer dual selectable color temperatures (specifically 4100K softwhite and 4500K bright white) adjustable for specific procedure types. Technological Salient Requirements: Server Requirements: ?The lights must deliver a maximum intensity of 160,000 lux and offer light headdiameter options of 24 inches or 30 inches to fill the surgical cavity with seamlesslight. ?The lighting architecture must integrate a manual focus mode of high-intensity LEDscombined with a centrally positioned ring of fixed-focus LEDs. ?The lights must be explicitly compatible with and ready for integration with flat-screen displays, booms, and HD surgical cameras. System Requirement: ?The suspension and arm system must provide at least 110 degrees of vertical travelto allow steep downward positioning. ?All axes of the lighting fixture must feature 360-degree continuous rotation withouthard spots. ?The optical design must allow the fixtures to be placed further away from the patientwhile maintaining precise detail.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"W81K0026QA200","place_of_performance":{"zip":"80913","city":{"name":"Colorado Springs"},"state":{"code":"CO"},"country":{"code":"USA"}},"product_service_code":"6530"},{"dates":{"posted":"2026-06-16","response_deadline":{"raw":"2026-06-22T11:00:00-06:00","utc":"2026-06-22T17:00:00Z","date":"2026-06-22","time":"11:00:00","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/f5b1b23993204a9a99b7ad6adfd7c097/view"},"naics":{"codes":["339113"],"primary":"339113"},"title":"L&D Surgical Lights","agency":{"office":{"code":"W81K00","name":"W40M MRC0 WEST"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"78234-4504","city":"JBSA FT SAM HOUSTON","state":"TX","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2026-07-07","archive_type":"auto15"},"contacts":[{"name":"Joseph Flores","role":"primary","email":"joseph.a.flores.civ@health.mil"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"f5b1b23993204a9a99b7ad6adfd7c097","set_aside":{"code":"SDVOSBS","label":"Service-Disabled Veteran-Owned Small Business Sole Source (FAR 19.14)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"526b78c91b1880d447254e990bb20cd0c664008bb611f270d1ebf5ef9b08a8f0","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-16T16:22:53.920682Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"text":"Clinical Salient Requirements: ?System must allow clinicians to adjust the focal point and working distance directlyfrom the center sterile handle without moving the light head or leaving the sterilefield. ?The light head must utilize vertically segmented reflectors to capture upward-directed light and redirect it downward, creating a crisp, homogenous spot thatminimizes shadows. ?The system must offer dual selectable color temperatures (specifically 4100K softwhite and 4500K bright white) adjustable for specific procedure types. Technological Salient Requirements: Server Requirements: ?The lights must deliver a maximum intensity of 160,000 lux and offer light headdiameter options of 24 inches or 30 inches to fill the surgical cavity with seamlesslight. ?The lighting architecture must integrate a manual focus mode of high-intensity LEDscombined with a centrally positioned ring of fixed-focus LEDs. ?The lights must be explicitly compatible with and ready for integration with flat-screen displays, booms, and HD surgical cameras. System Requirement: ?The suspension and arm system must provide at least 110 degrees of vertical travelto allow steep downward positioning. ?All axes of the lighting fixture must feature 360-degree continuous rotation withouthard spots. ?The optical design must allow the fixtures to be placed further away from the patientwhile maintaining precise detail.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"W81K0026QA200","place_of_performance":{"zip":"80913","city":{"name":"Colorado Springs"},"state":{"code":"CO"},"country":{"code":"USA"}},"product_service_code":"6530"}],"due_at":"2026-06-22T17:00:00Z","due_date":"2026-06-22","closes_at":"2026-06-22T17:00:00Z","awardable":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W81K00","office_name":"W40M MRC0 WEST","state":"CO","county":"08041","county_name":"El Paso County","city":"0816000","city_name":"Colorado Springs","country":"USA","winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z","principal_notice_id":"f5b1b23993204a9a99b7ad6adfd7c097","description":{"text":"Clinical Salient Requirements: ?System must allow clinicians to adjust the focal point and working distance directlyfrom the center sterile handle without moving the light head or leaving the sterilefield. ?The light head must utilize vertically segmented reflectors to capture upward-directed light and redirect it downward, creating a crisp, homogenous spot thatminimizes shadows. ?The system must offer dual selectable color temperatures (specifically 4100K softwhite and 4500K bright white) adjustable for specific procedure types. Technological Salient Requirements: Server Requirements: ?The lights must deliver a maximum intensity of 160,000 lux and offer light headdiameter options of 24 inches or 30 inches to fill the surgical cavity with seamlesslight. ?The lighting architecture must integrate a manual focus mode of high-intensity LEDscombined with a centrally positioned ring of fixed-focus LEDs. ?The lights must be explicitly compatible with and ready for integration with flat-screen displays, booms, and HD surgical cameras. System Requirement: ?The suspension and arm system must provide at least 110 degrees of vertical travelto allow steep downward positioning. ?All axes of the lighting fixture must feature 360-degree continuous rotation withouthard spots. ?The optical design must allow the fixtures to be placed further away from the patientwhile maintaining precise detail.","html":null,"origin":"extract"},"contacts":[{"name":"Joseph Flores","role":"primary","email":"joseph.a.flores.civ@health.mil"}],"place_of_performance":{"zip":"80913","city":{"name":"Colorado Springs"},"state":{"code":"CO"},"country":{"code":"USA"}},"office_address":{"zip":"78234-4504","city":"JBSA FT SAM HOUSTON","state":"TX","country":"USA"},"naics_codes":["339113"],"award":null,"attachments":[],"awards":[],"related":[{"key":"W81K0026QA274","latest_notice_id":"6d7a04c8f4fb4ed480c5933f458afb27","title":"Microbiology testing Kits and Consumables-Requirement is for consumables and kits are for pathogen detection.","solicitation_number":"W81K0026QA274","notice_type":"o","first_type":"o","first_posted":"2026-09-11","last_posted":"2026-09-11","notices":1,"due_at":"2026-09-21T18:00:00Z","due_date":"2026-09-21","closes_at":"2026-09-21T18:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W81K00","office_name":"W40M MRC0 WEST","naics":"334516","psc":"6640","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"W81K0026QA277","latest_notice_id":"0568e0001f5e4ede836c3a1eab2fef60","title":"EMS Mobile Application","solicitation_number":"W81K0026QA277","notice_type":"k","first_type":"k","first_posted":"2026-09-17","last_posted":"2026-09-17","notices":1,"due_at":"2026-09-22T14:00:00Z","due_date":"2026-09-22","closes_at":"2026-09-22T14:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W81K00","office_name":"W40M MRC0 WEST","naics":"513210","psc":"DA10","set_aside":"SBA","state":"TX","county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-18T04:00:44.545196Z"},{"key":"12440412","latest_notice_id":"09922343027443a6a17b702713699367","title":"Predictor Remediation Exam","solicitation_number":"12440412","notice_type":"r","first_type":"r","first_posted":"2026-09-18","last_posted":"2026-09-18","notices":1,"due_at":"2026-09-25T18:00:00Z","due_date":"2026-09-25","closes_at":"2026-09-25T18:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W81K00","office_name":"W40M MRC0 WEST","naics":"513210","psc":"U010","set_aside":null,"state":"TX","county":"48029","county_name":"Bexar County","city":null,"city_name":null,"country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-19T03:47:35.784222Z"},{"key":"W81K0027RA002","latest_notice_id":"851f6504aef343df9ba0420b3469c974","title":"Holistic Health and Fitness (H2F) Performance Team (HPT) services","solicitation_number":"W81K0027RA002","notice_type":"p","first_type":"p","first_posted":"2026-09-03","last_posted":"2026-09-03","notices":1,"due_at":"2026-09-30T18:00:00Z","due_date":"2026-09-30","closes_at":"2026-09-30T18:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W81K00","office_name":"W40M MRC0 WEST","naics":"621340","psc":"Q518","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"W81K0026QA240","latest_notice_id":"12280b8444954f7995a3674c9a2480d4","title":"Emergency Aeromedical Evacuation Services","solicitation_number":"W81K0026QA240","notice_type":"k","first_type":"k","first_posted":"2026-08-12","last_posted":"2026-09-17","notices":6,"due_at":"2026-10-01T15:00:00Z","due_date":"2026-10-01","closes_at":"2026-10-01T15:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W81K00","office_name":"W40M MRC0 WEST","naics":"481211","psc":"V221","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-18T04:00:44.545196Z"}]}