{"canonical":"https://abierto.us/opportunities/w519tc24qfire","key":"W519TC24QFIRE","url":"https://abierto.us/opportunities/w519tc24qfire","title":"Coating Compound, Thermal Insulation","solicitation_number":"W519TC24QFIRE","notice_type":"k","open":false,"response_deadline":"2024-08-21T21:00:00Z","first_posted":"2024-03-14","last_posted":"2024-07-31","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE ARMY","office":"W6QK ACC-RI","naics":"325510","psc":"6850","set_aside":null,"place_state":"IN","place_county":"18101","place_county_name":"Martin County","place_city":"1815652","place_city_name":"Crane","winner":null,"award_amount":null,"publications":[{"notice_id":"5794e5da32b64d408a3a0deab80a851d","title":"Fire Alarms & Fire Suppression Testing Request for Information / Sources Sought","solicitation_number":"W519TC-24-Q-FIRE","notice_type":"r","base_type":"r","posted":"2024-03-14","posted_at":null,"due_at":"2024-03-28T15:00:00Z","due_date":"2024-03-28","cancelled":null,"archived":null,"archive_date":"2024-11-30","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/5794e5da32b64d408a3a0deab80a851d/view","enriched":false,"history":[]},{"notice_id":"9581cfd2ac734f5e806743c15112965f","title":"Fire Alarms & Fire Suppression Testing Request for Information / Sources Sought","solicitation_number":"W519TC-24-Q-FIRE","notice_type":"r","base_type":"r","posted":"2024-03-14","posted_at":null,"due_at":"2024-03-28T15:00:00Z","due_date":"2024-03-28","cancelled":null,"archived":null,"archive_date":"2024-11-30","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/9581cfd2ac734f5e806743c15112965f/view","enriched":false,"history":[]},{"notice_id":"34147e3641194637a1c84b0cd239d9bd","title":"Coating Compound, Thermal Insulation","solicitation_number":"W519TC24QFIRE","notice_type":"k","base_type":"k","posted":"2024-07-31","posted_at":null,"due_at":"2024-08-21T21:00:00Z","due_date":"2024-08-21","cancelled":null,"archived":null,"archive_date":"2024-09-05","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/34147e3641194637a1c84b0cd239d9bd/view","enriched":false,"history":[]}],"latest_notice_id":"34147e3641194637a1c84b0cd239d9bd","first_type":"r","notices":[{"dates":{"posted":"2024-03-14","response_deadline":{"raw":"2024-03-28T10:00:00-05:00","utc":"2024-03-28T15:00:00Z","date":"2024-03-28","time":"10:00:00","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/5794e5da32b64d408a3a0deab80a851d/view"},"naics":{},"title":"Fire Alarms & Fire Suppression Testing Request for Information / Sources Sought","agency":{"office":{"code":"W52P1J","name":"W0DA US ARMY SUSTAINMENT CMD"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"61299-5000","city":"ROCK ISLAND","state":"IL","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-11-30","archive_type":"auto_custom"},"contacts":[{"name":"Megan K. Frost","role":"primary","email":"megan.k.frost2.civ@army.mil"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"5794e5da32b64d408a3a0deab80a851d","provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"dd164e07af28cd9118044ac43543529028c04cd1092fffaf061d08cd4fe898e6","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"14 March 2024 Request for Information / Sources Sought for Fire Alarms & Fire Suppression Testing The Army Contracting Command - Rock Island hereby issues this Request for Information / Sources Sought notice for Fire Alarms & Fire Suppression Testing at Tooele Army Depot. Interested parties should reply with their information no later than 10:00pm Central Standard Time on 28 March 2024. Please provide the following information via email to megan.k.frost2.civ@army.mil: Previous within scope work project details performed Estimated cost of services CAGE code UEI number Small business designation Business size status Any additional questions/information/feedback about the requirement This is a REQUEST FOR INFORMATION / SOURCES SOUGHT NOTICE only and shall not be construed as a solicitation or as an obligation on the part of the Government. This notice does not obligate the Government to award a contract or otherwise pay for the information provided in the response. The Government will not accept requests for meetings or briefings. No phone solicitations or email with regards to the status of the Request for Proposal (RFP) will be accepted prior to the solicitation release. PROJECT SUMMARY: INTRODUCTION Conducting a 100% (annual and special) testing of all Fire Alarms & Fire Suppression systems (fixed & portable) at Tooele Army Depot North and South areas (TEAD N & S). If applicable, all inspection, testing and maintenance (ITM) services performed under the direct supervision of a minimum National Institute for Certification in Engineering Technologies (NICET) level III, or State of Utah Certified fire alarm technician. The contractor is responsible for the accuracy, adequacy, timeliness and professionalism of the system tests and the testing documents. The contractor shall ensure testing conducted meet the requirements of the contract documents. Requirements include efficient project management including accurate, on-time submittals of contract deliverables (testing reports) and timely identification and solution of impediments to successful project execution. Technical requirements include early involvement in the process to allow for the development of the most cost-effective and technically sound solution. TEAD will rely on the Contractor’s expertise in recognizing and addressing problematic issues and successful execution. The Contractor shall perform all work in accordance with federal, state, and local statutes and regulations. The contractor shall conduct annual testing of all fire alarm & fire suppression systems located on TEAD North and TEAD South areas. Testing shall comply with provisions of UFC 3-601-02 Chapter 1, and Chapter 2, specifically tables 2-10, 2-11, 2-12, and 2-25. NFPA 25, NFPA 70 and NFPA 72 (ITM Tasks Attached). Contractor will identify any issues with each system and provide documentation of system status. Contractor will provide all equipment, materials, tags, labels, and reports necessary to complete the scope of this contract. Contractor will provide (one) 1 retest of each system not passing original testing (if required) additional testing beyond the 1 retest, shall be billed at a rate determined in the contract (fixed pricing) and agreed upon by the government. Presently there are 81 active fire alarms systems, (63 and TEAD North, with an additional 18 systems at TEAD South). There are 90 fire suppression systems, (56 TEAD North area, 22 TEAD South area, 4-fixed deluge, 6-portable deluge, and 2 FM 200 systems). These numbers may change due to new constructed buildings and or buildings being mothballed. Contractor will perform all testing and inspection of these systems and provide written documentation (to the COR) as to the status of each system, and any repairs that needed. Any system that is out of service, “mothballed”, or otherwise deemed not in use will not be tested on the normal schedule by the contractor, likewise any portable deluge system not actively in service at the time of scheduled testing will not be tested. These systems will be tested if brought back online during this contract. Contract COR will provide the contractor up to date listings of any systems that are down for longer terms. Additional suppression systems installed or that have had major upgrades performed will be tested and certified by the installation contractor. The testing contractor will not have these systems added to the contract until the next scheduled testing cycle. If a mothballed system brought back online during the testing cycle, this system may be added to the cycle if agreed upon by the contractor and the government. The Contractor shall identify and comply with all applicable federal, state, and local statutes. A partial list is presented at the end of this document. It is the Contractor’s fundamental responsibility to identify and comply with all mandatory federal and applicable DOD and Army requirements whether listed specifically in this document. SPECIFIC TASKS: Contractor shall perform the following for all Fire Alarm Systems/FAS TEAD North and TEAD South: (And associated detection/initiating/notifying devices) Conduct annual testing on all systems as required by UFC 3-601-02 (table 2-1) and NFPA 72 and 25 (to include by not limited to): Panels, LEDs, connections, programming, alarm transmission and receipt, backup batteries and power supplies, detection devices, pull stations, heat detectors, smoke detectors, supervisory devices, and all supporting equipment. Provide all required inspection tags, certifications, and reports when testing is complete. Copies of all reports are provided, to Fire and Emergency Services Division (COR) the COR will be responsible for providing copies of reports to other departments. Contractor, at a minimum, ensure that personnel conducting ITM task are NICET level III or equivalent, or certified by the state of Utah. Lower certified technicians may perform ITM tasks if supervised by someone holding NICET level III or equivalent. Contractor shall work with the COR (Fire Department) in scheduling, system access, reporting broken or non-functional systems, and rescheduling testing after any repairs are done in house. Contractor shall not shut down any system for testing or otherwise unless the COR has been contacted and notified. Any systems that is damaged or is not capable of functioning properly shall be immediately reported to the COR. COR will determine if systems taken offline and tagged out. Contractors and technicians will utilize the ITM tasks located in UFC 3-601-02, NFPA 72 and NFPA 70 to conduct all testing. SPECIFIC TASKS: Contractor shall perform the following for all Fixed Sprinkler Systems/FSS TEAD North and TEAD South. Conduct annual testing on all systems as required by UFC 3-601-02 (tables 2-2/2-3) and NFPA 13 and 25 (to include by not limited to): Gauges; Control Valves; Alarm Devices; Hydraulic Nameplates; Inspection of the entire building; Hangers/Seismic Bracing (exposed only, not above ceilings); Pipe and Fittings (exposed only, not above ceilings); Sprinklers (exposed only, not above ceilings); Spare sprinklers; Fire Department Connections; Valves (all types) Anti-freeze systems, and all supporting equipment. Provide all required inspection tags, certifications, and reports when testing is complete. Copies of all reports are provided, one to Fire and Emergency Services Division (COR) the COR will be responsible for providing copies of reports to other departments. Contractor at a minimum, ensure that personnel conducting ITM task are NICET level III or equivalent, or certified by the state of Utah. Lower certified technicians may perform ITM tasks if supervised by someone holding NICET level III or equivalent. Contractor shall work with the COR in scheduling, system access, reporting broken or non-functional systems, and rescheduling testing after any repairs are done in house. Contractor shall not shut down any system for testing or otherwise unless the COR has been contacted and notified. The point of contact at the Army Contracting Command - Rock Island is Megan Frost, megan.k.frost2.civ@army.mil","origin":"extract"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"W519TC-24-Q-FIRE","place_of_performance":{"zip":"84074","city":{"name":"Tooele"},"state":{"code":"UT"},"country":{"code":"USA"}}},{"dates":{"posted":"2024-03-14","response_deadline":{"raw":"2024-03-28T10:00:00-05:00","utc":"2024-03-28T15:00:00Z","date":"2024-03-28","time":"10:00:00","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/9581cfd2ac734f5e806743c15112965f/view"},"naics":{},"title":"Fire Alarms & Fire Suppression Testing Request for Information / Sources Sought","agency":{"office":{"code":"W52P1J","name":"W0DA US ARMY SUSTAINMENT CMD"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"61299-5000","city":"ROCK ISLAND","state":"IL","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-11-30","archive_type":"auto_custom"},"contacts":[{"name":"Megan K. Frost","role":"primary","email":"megan.k.frost2.civ@army.mil"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"9581cfd2ac734f5e806743c15112965f","provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"9a91ad3028f7888e2327a21a552f755a82e513978e47522aecd045db591a0c54","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"14 March 2024 Request for Information / Sources Sought for Fire Alarms & Fire Suppression Testing The Army Contracting Command - Rock Island hereby issues this Request for Information / Sources Sought notice for Fire Alarms & Fire Suppression Testing at Tooele Army Depot. Interested parties should reply with their information no later than 10:00pm Central Standard Time on 28 March 2024. Please provide the following information via email to megan.k.frost2.civ@army.mil: Previous within scope work project details performed Estimated cost of services CAGE code UEI number Small business designation Business size status Any additional questions/information/feedback about the requirement This is a REQUEST FOR INFORMATION / SOURCES SOUGHT NOTICE only and shall not be construed as a solicitation or as an obligation on the part of the Government. This notice does not obligate the Government to award a contract or otherwise pay for the information provided in the response. The Government will not accept requests for meetings or briefings. No phone solicitations or email with regards to the status of the Request for Proposal (RFP) will be accepted prior to the solicitation release. PROJECT SUMMARY: INTRODUCTION Conducting a 100% (annual and special) testing of all Fire Alarms & Fire Suppression systems (fixed & portable) at Tooele Army Depot North and South areas (TEAD N & S). If applicable, all inspection, testing and maintenance (ITM) services performed under the direct supervision of a minimum National Institute for Certification in Engineering Technologies (NICET) level III, or State of Utah Certified fire alarm technician. The contractor is responsible for the accuracy, adequacy, timeliness and professionalism of the system tests and the testing documents. The contractor shall ensure testing conducted meet the requirements of the contract documents. Monaco is the current fire alarm system. Requirements include efficient project management including accurate, on-time submittals of contract deliverables (testing reports) and timely identification and solution of impediments to successful project execution. Technical requirements include early involvement in the process to allow for the development of the most cost-effective and technically sound solution. TEAD will rely on the Contractor’s expertise in recognizing and addressing problematic issues and successful execution. The Contractor shall perform all work in accordance with federal, state, and local statutes and regulations. The contractor shall conduct annual testing of all fire alarm & fire suppression systems located on TEAD North and TEAD South areas. Testing shall comply with provisions of UFC 3-601-02 Chapter 1, and Chapter 2, specifically tables 2-10, 2-11, 2-12, and 2-25. NFPA 25, NFPA 70 and NFPA 72 (ITM Tasks Attached). Contractor will identify any issues with each system and provide documentation of system status. Contractor will provide all equipment, materials, tags, labels, and reports necessary to complete the scope of this contract. Contractor will provide (one) 1 retest of each system not passing original testing (if required) additional testing beyond the 1 retest, shall be billed at a rate determined in the contract (fixed pricing) and agreed upon by the government. Presently there are 81 active fire alarms systems, (63 and TEAD North, with an additional 18 systems at TEAD South). There are 90 fire suppression systems, (56 TEAD North area, 22 TEAD South area, 4-fixed deluge, 6-portable deluge, and 2 FM 200 systems). These numbers may change due to new constructed buildings and or buildings being mothballed. Contractor will perform all testing and inspection of these systems and provide written documentation (to the COR) as to the status of each system, and any repairs that needed. Any system that is out of service, “mothballed”, or otherwise deemed not in use will not be tested on the normal schedule by the contractor, likewise any portable deluge system not actively in service at the time of scheduled testing will not be tested. These systems will be tested if brought back online during this contract. Contract COR will provide the contractor up to date listings of any systems that are down for longer terms. Additional suppression systems installed or that have had major upgrades performed will be tested and certified by the installation contractor. The testing contractor will not have these systems added to the contract until the next scheduled testing cycle. If a mothballed system brought back online during the testing cycle, this system may be added to the cycle if agreed upon by the contractor and the government. The Contractor shall identify and comply with all applicable federal, state, and local statutes. A partial list is presented at the end of this document. It is the Contractor’s fundamental responsibility to identify and comply with all mandatory federal and applicable DOD and Army requirements whether listed specifically in this document. SPECIFIC TASKS: Contractor shall perform the following for all Fire Alarm Systems/FAS TEAD North and TEAD South: (And associated detection/initiating/notifying devices) Conduct annual testing on all systems as required by UFC 3-601-02 (table 2-1) and NFPA 72 and 25 (to include by not limited to): Panels, LEDs, connections, programming, alarm transmission and receipt, backup batteries and power supplies, detection devices, pull stations, heat detectors, smoke detectors, supervisory devices, and all supporting equipment. Provide all required inspection tags, certifications, and reports when testing is complete. Copies of all reports are provided, to Fire and Emergency Services Division (COR) the COR will be responsible for providing copies of reports to other departments. Contractor, at a minimum, ensure that personnel conducting ITM task are NICET level III or equivalent, or certified by the state of Utah. Lower certified technicians may perform ITM tasks if supervised by someone holding NICET level III or equivalent. Contractor shall work with the COR (Fire Department) in scheduling, system access, reporting broken or non-functional systems, and rescheduling testing after any repairs are done in house. Contractor shall not shut down any system for testing or otherwise unless the COR has been contacted and notified. Any systems that is damaged or is not capable of functioning properly shall be immediately reported to the COR. COR will determine if systems taken offline and tagged out. Contractors and technicians will utilize the ITM tasks located in UFC 3-601-02, NFPA 72 and NFPA 70 to conduct all testing. SPECIFIC TASKS: Contractor shall perform the following for all Fixed Sprinkler Systems/FSS TEAD North and TEAD South. Conduct annual testing on all systems as required by UFC 3-601-02 (tables 2-2/2-3) and NFPA 13 and 25 (to include by not limited to): Gauges; Control Valves; Alarm Devices; Hydraulic Nameplates; Inspection of the entire building; Hangers/Seismic Bracing (exposed only, not above ceilings); Pipe and Fittings (exposed only, not above ceilings); Sprinklers (exposed only, not above ceilings); Spare sprinklers; Fire Department Connections; Valves (all types) Anti-freeze systems, and all supporting equipment. Provide all required inspection tags, certifications, and reports when testing is complete. Copies of all reports are provided, one to Fire and Emergency Services Division (COR) the COR will be responsible for providing copies of reports to other departments. Contractor at a minimum, ensure that personnel conducting ITM task are NICET level III or equivalent, or certified by the state of Utah. Lower certified technicians may perform ITM tasks if supervised by someone holding NICET level III or equivalent. Contractor shall work with the COR in scheduling, system access, reporting broken or non-functional systems, and rescheduling testing after any repairs are done in house. Contractor shall not shut down any system for testing or otherwise unless the COR has been contacted and notified. The point of contact at the Army Contracting Command - Rock Island is Megan Frost, megan.k.frost2.civ@army.mil","origin":"extract"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"W519TC-24-Q-FIRE","place_of_performance":{"zip":"84074","city":{"name":"Tooele"},"state":{"code":"UT"},"country":{"code":"USA"}}},{"dates":{"posted":"2024-07-31","response_deadline":{"raw":"2024-08-21T16:00:00-05:00","utc":"2024-08-21T21:00:00Z","date":"2024-08-21","time":"16:00:00","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/34147e3641194637a1c84b0cd239d9bd/view"},"naics":{"codes":["325510"],"primary":"325510"},"title":"Coating Compound, Thermal Insulation","agency":{"office":{"code":"W519TC","name":"W6QK ACC-RI"},"subtier":{"code":"2100","name":"DEPT OF THE ARMY"},"department":{"code":"021","name":"DEPT OF DEFENSE"},"office_address":{"zip":"61299-0000","city":"ROCK ISLAND","state":"IL","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-09-05","archive_type":"auto15"},"contacts":[{"name":"Dora Smith","role":"primary","email":"dora.d.smith5.civ@army.mil"},{"name":"Bryce Willett","role":"secondary","email":"bryce.t.willett.civ@army.mil"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"34147e3641194637a1c84b0cd239d9bd","provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"8b8795226d6885efc9529158864ad6041e479c6d9890715c5ec8e3a65d2ad7d9","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"This is a Combined Solicitation Synopsis using FAR Part 12, Acquisition of Commercial Items; the Solicitation Number is W519TC-24-Q-FIRE. The NAICS code for this procurement is 325510; The Product Service Code is 6850, Miscellaneous Chemical Specialties. You must be registered within the System for Award Management (SAM) databased at time of response to this solicitation. The website for SAM is https://www.sam.gov/. Addendum to 52.212-1 DESCRIPTION OF REQUIREMENT CLIN 0001: QUANTITY UNIT Fireproofing Chemical, Part# FMA260. Must meet or exceed 64,000 LBS. MIL-PRF-81904C/QPL 91904(AS), Ghost Gray, in accordance With Federal Standard (FED STD) 595, No. 36375. Material Must include Thixotrope. A Certificate of Analysis and SDS are required with each shipment. Product to be shipped in 55-gallon drums, 4 drums per pallet, 500 LBS per drum. Material must be palletized. ATTACHMENT 0003- Material Test/Certificate of Analysis Report DELIVERY AND LOCATION CLIN Description Delivery Date 0001 FMA260 60/90 DAYS After Receipt of Award (AR0) Delivery will be FOB Destination to Crane Army Ammunition Activity, Building 148 300 Highway 361, Crane, IN 47522-5001, in accordance with the following: Crane Army Ammunition Activity Delivery Instructions: CAAA receiving hours are 0700 – 1430, Mon - Thurs BY APPOINTMENT ONLY; Includes Inert & Freight All Kind (FAK). Appointments shall be made via Carrier Appointment System (CAS). Carriers without access to the CAS System, call (812)854-2199 or (812)854-2339, 48 hours prior to delivery for appointment. Failure to follow the protocol stated herein and/or obtain a scheduled delivery time prior to delivery, may result in the truck being turned away. PACKAGING AND MARKING REQUIREMENTS Preservation, Packaging, and Packing shall be in accordance with ASTM D 3951 Commercial Packaging, in 55 Gallon Drums 500 LBS each. Listing of Attachments: Attachment 0001 – Redacted Limited Source Justification MFR – FMA260. Attachment 0002 – Price Matrix Attachment 0003 – Material Certification Test Report/Certification of Analysis Offerors shall submit the following Attachments in response to this solicitation: 1. Price – Offeror must submit Completed Price Matrix at Attachment 0002. All yellow-highlighted sections shall be completed. Prices shall be stated to 2 decimal places. 2. Identification and Material Safety Data. BASIS FOR AWARD The Government intends to make an award after determination that the price is reasonable, and the offeror is responsible. Price Analysis shall be used to determine price reasonableness; additional methods of price analysis may be used as determined by the contracting officer. These methods of evaluation may include information/input from sources such as (but not limited to) other Governmental agencies and personnel. The Government reserves the right to require the submission of any data (i.e.., Data other Than Certified Cost or Pricing Data necessary to validate the reasonableness of an offer. In accordance with FAR 52.212-1(g), the Government intends to award a contract against this solicitation without discussions. DEADLINE FOR SUBMISSION Offers are due on 21 August no later than 1600 Central Time. The Government’s intent is to award this contract to International Paint, LLC. Questions regarding this requirement will not be answered, as the attached LSJ is a final decision, and other offerors will not be entertained for this requirement. Offers shall be submitted in the following way: Electronically via email to the Contract Specialist, dora.d.smith5.civ@army.mil; and Contracting Officer, bryce.t.willett.civ@army.mil. Offerors shall include “W519TC-24-Q-FIRE - Response – [Insert Offeror’s Name]” within the Subject line. End of Addendum 52.212-1","origin":"extract"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"W519TC24QFIRE","place_of_performance":{"city":{"name":"Crane"},"state":{"code":"IN"},"country":{"code":"USA"}},"product_service_code":"6850"}],"due_at":"2024-08-21T21:00:00Z","due_date":"2024-08-21","closes_at":"2024-08-21T21:00:00Z","awardable":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W519TC","office_name":"W6QK ACC-RI","state":"IN","county":"18101","county_name":"Martin County","city":"1815652","city_name":"Crane","country":"USA","winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z","principal_notice_id":"34147e3641194637a1c84b0cd239d9bd","description":{"text":"This is a Combined Solicitation Synopsis using FAR Part 12, Acquisition of Commercial Items; the Solicitation Number is W519TC-24-Q-FIRE. The NAICS code for this procurement is 325510; The Product Service Code is 6850, Miscellaneous Chemical Specialties. You must be registered within the System for Award Management (SAM) databased at time of response to this solicitation. The website for SAM is https://www.sam.gov/. Addendum to 52.212-1 DESCRIPTION OF REQUIREMENT CLIN 0001: QUANTITY UNIT Fireproofing Chemical, Part# FMA260. Must meet or exceed 64,000 LBS. MIL-PRF-81904C/QPL 91904(AS), Ghost Gray, in accordance With Federal Standard (FED STD) 595, No. 36375. Material Must include Thixotrope. A Certificate of Analysis and SDS are required with each shipment. Product to be shipped in 55-gallon drums, 4 drums per pallet, 500 LBS per drum. Material must be palletized. ATTACHMENT 0003- Material Test/Certificate of Analysis Report DELIVERY AND LOCATION CLIN Description Delivery Date 0001 FMA260 60/90 DAYS After Receipt of Award (AR0) Delivery will be FOB Destination to Crane Army Ammunition Activity, Building 148 300 Highway 361, Crane, IN 47522-5001, in accordance with the following: Crane Army Ammunition Activity Delivery Instructions: CAAA receiving hours are 0700 – 1430, Mon - Thurs BY APPOINTMENT ONLY; Includes Inert & Freight All Kind (FAK). Appointments shall be made via Carrier Appointment System (CAS). Carriers without access to the CAS System, call (812)854-2199 or (812)854-2339, 48 hours prior to delivery for appointment. Failure to follow the protocol stated herein and/or obtain a scheduled delivery time prior to delivery, may result in the truck being turned away. PACKAGING AND MARKING REQUIREMENTS Preservation, Packaging, and Packing shall be in accordance with ASTM D 3951 Commercial Packaging, in 55 Gallon Drums 500 LBS each. Listing of Attachments: Attachment 0001 – Redacted Limited Source Justification MFR – FMA260. Attachment 0002 – Price Matrix Attachment 0003 – Material Certification Test Report/Certification of Analysis Offerors shall submit the following Attachments in response to this solicitation: 1. Price – Offeror must submit Completed Price Matrix at Attachment 0002. All yellow-highlighted sections shall be completed. Prices shall be stated to 2 decimal places. 2. Identification and Material Safety Data. BASIS FOR AWARD The Government intends to make an award after determination that the price is reasonable, and the offeror is responsible. Price Analysis shall be used to determine price reasonableness; additional methods of price analysis may be used as determined by the contracting officer. These methods of evaluation may include information/input from sources such as (but not limited to) other Governmental agencies and personnel. The Government reserves the right to require the submission of any data (i.e.., Data other Than Certified Cost or Pricing Data necessary to validate the reasonableness of an offer. In accordance with FAR 52.212-1(g), the Government intends to award a contract against this solicitation without discussions. DEADLINE FOR SUBMISSION Offers are due on 21 August no later than 1600 Central Time. The Government’s intent is to award this contract to International Paint, LLC. Questions regarding this requirement will not be answered, as the attached LSJ is a final decision, and other offerors will not be entertained for this requirement. Offers shall be submitted in the following way: Electronically via email to the Contract Specialist, dora.d.smith5.civ@army.mil; and Contracting Officer, bryce.t.willett.civ@army.mil. Offerors shall include “W519TC-24-Q-FIRE - Response – [Insert Offeror’s Name]” within the Subject line. End of Addendum 52.212-1","html":null,"origin":"extract"},"contacts":[{"name":"Dora Smith","role":"primary","email":"dora.d.smith5.civ@army.mil"},{"name":"Bryce Willett","role":"secondary","email":"bryce.t.willett.civ@army.mil"}],"place_of_performance":{"city":{"name":"Crane"},"state":{"code":"IN"},"country":{"code":"USA"}},"office_address":{"zip":"61299-0000","city":"ROCK ISLAND","state":"IL","country":"USA"},"naics_codes":["325510"],"award":null,"attachments":[],"awards":[],"related":[{"key":"W519TC26R0027","latest_notice_id":"2832a9738f714a1ca79545a1e55c5fb2","title":"Thin Layer Explosives (SP02/SP03)","solicitation_number":"W519TC26R0027","notice_type":"o","first_type":"o","first_posted":"2026-07-22","last_posted":"2026-07-27","notices":2,"due_at":"2026-09-18T19:00:00Z","due_date":"2026-09-18","closes_at":"2026-09-18T19:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W519TC","office_name":"W6QK ACC-RI","naics":"325920","psc":"1377","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"W519TC26FA663","latest_notice_id":"bf6ca7b388bf4de1b323c1643e271859","title":"Notice of Intent to Sole Source - Salesforce Licenses for Cyber Academic Engagement Office (CAEO)","solicitation_number":"W519TC26FA663","notice_type":"r","first_type":"r","first_posted":"2026-09-15","last_posted":"2026-09-15","notices":1,"due_at":"2026-09-21T12:00:00Z","due_date":"2026-09-21","closes_at":"2026-09-21T12:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W519TC","office_name":"W6QK ACC-RI","naics":"513210","psc":"AC32","set_aside":null,"state":"DC","county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"W519TC26Q3971001","latest_notice_id":"bbcbfa5f508045f8a7a275edfd805424","title":"2 each 17,500lb fork lifts","solicitation_number":"W519TC26Q3971001","notice_type":"k","first_type":"k","first_posted":"2026-09-14","last_posted":"2026-09-14","notices":1,"due_at":"2026-09-21T15:00:00Z","due_date":"2026-09-21","closes_at":"2026-09-21T15:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W519TC","office_name":"W6QK ACC-RI","naics":"532412","psc":"W039","set_aside":"SBA","state":"OK","county":"40121","county_name":"Pittsburg County","city":null,"city_name":null,"country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"W519TC26QA214","latest_notice_id":"69ed41e56d334554bd39dfe06894cd28","title":"Pine Bluff Arsenal Intrusion Detection System","solicitation_number":"W519TC-26-Q-A214","notice_type":"k","first_type":"k","first_posted":"2026-09-10","last_posted":"2026-09-16","notices":4,"due_at":"2026-09-21T17:00:00Z","due_date":"2026-09-21","closes_at":"2026-09-21T17:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W519TC","office_name":"W6QK ACC-RI","naics":"561621","psc":"J063","set_aside":null,"state":"AR","county":"05069","county_name":"Jefferson County","city":"0575170","city_name":"White Hall","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-17T06:28:38.602097Z"},{"key":"W519TC26Q8816","latest_notice_id":"1816a6bf1c3b4d1f97efeb10cb53ea60","title":"CLAMP, SUPPORT (FORGING)","solicitation_number":"W519TC26Q8816","notice_type":"k","first_type":"k","first_posted":"2026-09-10","last_posted":"2026-09-17","notices":2,"due_at":"2026-09-22T16:00:00Z","due_date":"2026-09-22","closes_at":"2026-09-22T16:00:00Z","awardable":true,"open":true,"dept_key":"d-021","dept_name":"DEPT OF DEFENSE","sub_key":"s-2100","sub_name":"DEPT OF THE ARMY","office_key":"o-W519TC","office_name":"W6QK ACC-RI","naics":"332111","psc":"3680","set_aside":null,"state":"IL","county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-18T04:00:44.545196Z"}]}