{"canonical":"https://abierto.us/opportunities/ssncvm2026134067","key":"SSNCVM2026134067","url":"https://abierto.us/opportunities/ssncvm2026134067","title":"Bio Safey Cabinets","solicitation_number":"SSN_CVM-2026-134067","notice_type":"r","open":false,"response_deadline":"2026-05-15T16:00:00Z","first_posted":"2026-05-11","last_posted":"2026-05-12","department":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","subagency":"FOOD AND DRUG ADMINISTRATION","office":"FDA OFFICE OF ACQ GRANT SVCS","naics":"334516","psc":"6640","set_aside":"SBA","place_state":"MD","place_county":"24033","place_county_name":"Prince George's County","place_city":"2445900","place_city_name":"Laurel","winner":null,"award_amount":null,"publications":[{"notice_id":"3bf70a383e724120bf7cdb16050306bb","title":"Bio Safey Cabinets","solicitation_number":"SSN_CVM-2026-134067","notice_type":"r","base_type":"r","posted":"2026-05-11","posted_at":null,"due_at":"2026-05-15T16:00:00Z","due_date":"2026-05-15","cancelled":null,"archived":null,"archive_date":"2026-05-16","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/3bf70a383e724120bf7cdb16050306bb/view","enriched":false,"history":[]},{"notice_id":"ad12fc986bdb43859919693feb05d452","title":"Bio Safey Cabinets","solicitation_number":"SSN_CVM-2026-134067","notice_type":"r","base_type":"r","posted":"2026-05-12","posted_at":null,"due_at":"2026-05-15T16:00:00Z","due_date":"2026-05-15","cancelled":null,"archived":null,"archive_date":"2026-05-16","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/ad12fc986bdb43859919693feb05d452/view","enriched":false,"history":[]}],"latest_notice_id":"ad12fc986bdb43859919693feb05d452","first_type":"r","notices":[{"dates":{"posted":"2026-05-11","response_deadline":{"raw":"2026-05-15T12:00:00-04:00","utc":"2026-05-15T16:00:00Z","date":"2026-05-15","time":"12:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/3bf70a383e724120bf7cdb16050306bb/view"},"naics":{"codes":["334516"],"primary":"334516"},"title":"Bio Safey Cabinets","agency":{"office":{"code":"75F401","name":"FDA OFFICE OF ACQ GRANT SVCS"},"subtier":{"code":"7524","name":"FOOD AND DRUG ADMINISTRATION"},"department":{"code":"075","name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF"},"office_address":{"zip":"20852","city":"Rockville","state":"MD","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2026-05-16","archive_type":"auto_custom"},"contacts":[{"name":"Reagan Davis","role":"primary","email":"reagan.davis@fda.hhs.gov","phone":"3017960910"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"3bf70a383e724120bf7cdb16050306bb","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"15b9d79e90254c0a524d0dfaab53f2513a06ce607b7100096bd03bb377e91ccd","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-16T16:22:53.920682Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"text":"We expect to acquire seven new BSCs according to our specifications. The Contractor shall provide seven (7) biosafety cabinets consisting of: • One (1) 6-foot wide unit • Six (6) 4-foot wide units All BSCs are expected to meet certification standards (NSF/ANSI 49) upon delivery. Deliverables The following are the requirements that should be met at the minimum: • Units shall be available in unit widths of 6 ft (one unit) and 4 ft (six units) • Units must meet the performance requirements of NSF/ANSI 49. • Units shall have supply HEPA filters 99.99% efficient at a particle size of 0.3 micron by DOP test and shall be of full cabinet work zone width and depth. • Units shall have exhaust HEPA filters 99.99% efficient at a particle size of 0.3 microns by DOP test • Units shall be constructed from 16 or 18 gauge Type 304 stainless steel, forming a monolithic, sealed structure. • Units shall possess a height adjustable base stand such that workspace height can be adjusted from at least 30 to 36 inches. • Units’ power shall be supplied with a minimum 12-foot (2.5m) grounded electrical cable. Electrical supply should be 115 VAC, 60 Hz. • Units shall be easily transportable through a 40 inch (1016 mm) wide, 83 in (2108 mm) tall door without disassembly. • Units shall come standard with two outlets with drip proof covers; one gas valve/service coupling on right side wall; one service coupling on right side wall; two service couplings on left side wall. • Units shall be capable of front filter removal without disassembly of the control panel and sliding window tracks/hardware. • Units shall feature a sliding viewing window that operates smoothly from full closure to full opening at 20 inches. • Units shall have a working access height of 10 inches. • Units shall feature a non-metallic armrest/airfoil incorporating an at least 2 inch (51mm) forearm support area. • Units shall feature an audible alarm and flashing LED to warn of an unsafe viewscreen position. The units will also signal power loss with visual and audible alarms • Units shall include base stand with work surface height between 25 and 35 in • Units shall include an ultraviolet (UV) light fixture. • Units shall be warranted for parts and labor for at least 60 months from the date of acceptance. • Pricing shall include shipping cost.","origin":"extract"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"SSN_CVM-2026-134067","place_of_performance":{"zip":"20708","city":{"name":"Laurel"},"state":{"code":"MD"},"country":{"code":"USA"}},"product_service_code":"6640"},{"dates":{"posted":"2026-05-12","response_deadline":{"raw":"2026-05-15T12:00:00-04:00","utc":"2026-05-15T16:00:00Z","date":"2026-05-15","time":"12:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/ad12fc986bdb43859919693feb05d452/view"},"naics":{"codes":["334516"],"primary":"334516"},"title":"Bio Safey Cabinets","agency":{"office":{"code":"75F401","name":"FDA OFFICE OF ACQ GRANT SVCS"},"subtier":{"code":"7524","name":"FOOD AND DRUG ADMINISTRATION"},"department":{"code":"075","name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF"},"office_address":{"zip":"20852","city":"Rockville","state":"MD","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2026-05-16","archive_type":"auto_custom"},"contacts":[{"name":"Reagan Davis","role":"primary","email":"reagan.davis@fda.hhs.gov","phone":"3017960910"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"ad12fc986bdb43859919693feb05d452","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"bd9bf076db3f65f2d2d80431f84776cab3d21541b264dbe5c00c12517b70f08f","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-16T16:22:53.920682Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"text":"We expect to acquire seven new BSCs according to our specifications. The Contractor shall provide seven (7) biosafety cabinets consisting of: • One (1) 6-foot wide unit • Six (6) 4-foot wide units All BSCs are expected to meet certification standards (NSF/ANSI 49) upon delivery. Deliverables The following are the requirements that should be met at the minimum: • Class II: Protects personnel, environment, and product (samples). The most common type, offering sterile conditions, ideal for BSL-1 through BSL-3. • Units shall be available in unit widths of 6 ft (one unit) and 4 ft (six units) • Units must meet the performance requirements of NSF/ANSI 49. • Units shall have supply HEPA filters 99.99% efficient at a particle size of 0.3 micron by DOP test and shall be of full cabinet work zone width and depth. • Units shall have exhaust HEPA filters 99.99% efficient at a particle size of 0.3 microns by DOP test • Units shall be constructed from 16 or 18 gauge Type 304 stainless steel, forming a monolithic, sealed structure. • Units shall possess a height adjustable base stand such that workspace height can be adjusted from at least 30 to 36 inches. • Units’ power shall be supplied with a minimum 12-foot (2.5m) grounded electrical cable. Electrical supply should be 115 VAC, 60 Hz. • Units shall be easily transportable through a 40 inch (1016 mm) wide, 83 in (2108 mm) tall door without disassembly. • Units shall come standard with two outlets with drip proof covers; one gas valve/service coupling on right side wall; one service coupling on right side wall; two service couplings on left side wall. • Units shall be capable of front filter removal without disassembly of the control panel and sliding window tracks/hardware. • Units shall feature a sliding viewing window that operates smoothly from full closure to full opening at 20 inches. • Units shall have a working access height of 10 inches. • Units shall feature a non-metallic armrest/airfoil incorporating an at least 2 inch (51mm) forearm support area. • Units shall feature an audible alarm and flashing LED to warn of an unsafe viewscreen position. The units will also signal power loss with visual and audible alarms • Units shall include base stand with work surface height between 25 and 35 in • Units shall include an ultraviolet (UV) light fixture. • Units shall be warranted for parts and labor for at least 60 months from the date of acceptance. • Pricing shall include shipping cost.","origin":"extract"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"SSN_CVM-2026-134067","place_of_performance":{"zip":"20708","city":{"name":"Laurel"},"state":{"code":"MD"},"country":{"code":"USA"}},"product_service_code":"6640"}],"due_at":"2026-05-15T16:00:00Z","due_date":"2026-05-15","closes_at":"2026-05-15T16:00:00Z","awardable":true,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7524","sub_name":"FOOD AND DRUG ADMINISTRATION","office_key":"o-75F401","office_name":"FDA OFFICE OF ACQ GRANT SVCS","state":"MD","county":"24033","county_name":"Prince George's County","city":"2445900","city_name":"Laurel","country":"USA","winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z","principal_notice_id":"ad12fc986bdb43859919693feb05d452","description":{"text":"We expect to acquire seven new BSCs according to our specifications. The Contractor shall provide seven (7) biosafety cabinets consisting of: • One (1) 6-foot wide unit • Six (6) 4-foot wide units All BSCs are expected to meet certification standards (NSF/ANSI 49) upon delivery. Deliverables The following are the requirements that should be met at the minimum: • Class II: Protects personnel, environment, and product (samples). The most common type, offering sterile conditions, ideal for BSL-1 through BSL-3. • Units shall be available in unit widths of 6 ft (one unit) and 4 ft (six units) • Units must meet the performance requirements of NSF/ANSI 49. • Units shall have supply HEPA filters 99.99% efficient at a particle size of 0.3 micron by DOP test and shall be of full cabinet work zone width and depth. • Units shall have exhaust HEPA filters 99.99% efficient at a particle size of 0.3 microns by DOP test • Units shall be constructed from 16 or 18 gauge Type 304 stainless steel, forming a monolithic, sealed structure. • Units shall possess a height adjustable base stand such that workspace height can be adjusted from at least 30 to 36 inches. • Units’ power shall be supplied with a minimum 12-foot (2.5m) grounded electrical cable. Electrical supply should be 115 VAC, 60 Hz. • Units shall be easily transportable through a 40 inch (1016 mm) wide, 83 in (2108 mm) tall door without disassembly. • Units shall come standard with two outlets with drip proof covers; one gas valve/service coupling on right side wall; one service coupling on right side wall; two service couplings on left side wall. • Units shall be capable of front filter removal without disassembly of the control panel and sliding window tracks/hardware. • Units shall feature a sliding viewing window that operates smoothly from full closure to full opening at 20 inches. • Units shall have a working access height of 10 inches. • Units shall feature a non-metallic armrest/airfoil incorporating an at least 2 inch (51mm) forearm support area. • Units shall feature an audible alarm and flashing LED to warn of an unsafe viewscreen position. The units will also signal power loss with visual and audible alarms • Units shall include base stand with work surface height between 25 and 35 in • Units shall include an ultraviolet (UV) light fixture. • Units shall be warranted for parts and labor for at least 60 months from the date of acceptance. • Pricing shall include shipping cost.","html":null,"origin":"extract"},"contacts":[{"name":"Reagan Davis","role":"primary","email":"reagan.davis@fda.hhs.gov","phone":"3017960910"}],"place_of_performance":{"zip":"20708","city":{"name":"Laurel"},"state":{"code":"MD"},"country":{"code":"USA"}},"office_address":{"zip":"20852","city":"Rockville","state":"MD","country":"USA"},"naics_codes":["334516"],"award":null,"attachments":[],"awards":[],"related":[{"key":"RFQCDR2026135968","latest_notice_id":"0a2d3e56451c4afa948835a62000bb09","title":"Human Hindbrain Organoid Functional Assay Services.","solicitation_number":"RFQ_CDR-2026-135968","notice_type":"k","first_type":"k","first_posted":"2026-09-11","last_posted":"2026-09-11","notices":1,"due_at":"2026-09-17T14:30:00Z","due_date":"2026-09-17","closes_at":"2026-09-17T14:30:00Z","awardable":true,"open":true,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7524","sub_name":"FOOD AND DRUG ADMINISTRATION","office_key":"o-75F401","office_name":"FDA OFFICE OF ACQ GRANT SVCS","naics":"541714","psc":"B504","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"75F40126Q00386","latest_notice_id":"27e99454af4c4254b10a9b32de928143","title":"Walk-In Laboratory Cooler","solicitation_number":"75F40126Q00386","notice_type":"o","first_type":"o","first_posted":"2026-09-10","last_posted":"2026-09-15","notices":4,"due_at":"2026-09-18T18:30:00Z","due_date":"2026-09-18","closes_at":"2026-09-18T18:30:00Z","awardable":true,"open":true,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7524","sub_name":"FOOD AND DRUG ADMINISTRATION","office_key":"o-75F401","office_name":"FDA OFFICE OF ACQ GRANT SVCS","naics":"333415","psc":"4110","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"75F40126Q00407","latest_notice_id":"dc8b1da2c3b8402b93fcd096bc1f5681","title":"Rapid Nicotine Pouch Data Analysis Services","solicitation_number":"75F40126Q00407","notice_type":"k","first_type":"k","first_posted":"2026-09-14","last_posted":"2026-09-14","notices":1,"due_at":"2026-09-18T19:00:00Z","due_date":"2026-09-18","closes_at":"2026-09-18T19:00:00Z","awardable":true,"open":true,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7524","sub_name":"FOOD AND DRUG ADMINISTRATION","office_key":"o-75F401","office_name":"FDA OFFICE OF ACQ GRANT SVCS","naics":"541618","psc":"R405","set_aside":null,"state":"MD","county":"24031","county_name":"Montgomery County","city":"2472450","city_name":"Silver Spring","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"75F40126Q000430","latest_notice_id":"bf394f65a0c24e6e972fa67201ef529d","title":"Vanquish Neo System and Ion Chromatography system","solicitation_number":"75F40126Q000430","notice_type":"o","first_type":"o","first_posted":"2026-09-10","last_posted":"2026-09-10","notices":1,"due_at":"2026-09-21T14:30:00Z","due_date":"2026-09-21","closes_at":"2026-09-21T14:30:00Z","awardable":true,"open":true,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7524","sub_name":"FOOD AND DRUG ADMINISTRATION","office_key":"o-75F401","office_name":"FDA OFFICE OF ACQ GRANT SVCS","naics":"334516","psc":"6640","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"RFQCBER2026135968","latest_notice_id":"b42cc936a36045f68ceffa9f327a878a","title":"2D High-Density Multi-Electrode Array Electrophysiology Platform","solicitation_number":"RFQ_CBER-2026-135968","notice_type":"k","first_type":"k","first_posted":"2026-09-14","last_posted":"2026-09-14","notices":1,"due_at":"2026-09-23T14:00:00Z","due_date":"2026-09-23","closes_at":"2026-09-23T14:00:00Z","awardable":true,"open":true,"dept_key":"d-075","dept_name":"HEALTH AND HUMAN SERVICES, DEPARTMENT OF","sub_key":"s-7524","sub_name":"FOOD AND DRUG ADMINISTRATION","office_key":"o-75F401","office_name":"FDA OFFICE OF ACQ GRANT SVCS","naics":"334516","psc":"6640","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"}]}