{"canonical":"https://abierto.us/opportunities/qse36c10f24r50000","key":"QSE36C10F24R50000","url":"https://abierto.us/opportunities/qse36c10f24r50000","title":"Design Build Construction to Replace Seismically Deficient Boiler Plant, Building 8. VAMC Reno, NV. -- Y1NB","solicitation_number":"QSE--36C10F24R50000","notice_type":"a","open":false,"response_deadline":"2024-08-30T01:00:00Z","first_posted":"2024-02-12","last_posted":"2025-04-25","department":"VETERANS AFFAIRS, DEPARTMENT OF","subagency":"VETERANS AFFAIRS, DEPARTMENT OF","office":"OFFICE OF CONSTRUCTION & FACILITIES MGMT (36C10F)","naics":"236220","psc":"Y1NB","set_aside":"SDVOSBC","place_state":"NV","place_county":"32031","place_county_name":"Washoe County","place_city":"3260600","place_city_name":"Reno","winner":"SGJV2, LLC","award_amount":"77604919","publications":[{"notice_id":"37574e9ad573483a86bb352628fcde3b","title":"Design Build Central Utilities Plant - Reno NV -- Y1NB","solicitation_number":"QSE--36C10F24R50000","notice_type":"p","base_type":"p","posted":"2024-02-12","posted_at":null,"due_at":null,"due_date":null,"cancelled":null,"archived":null,"archive_date":"2025-12-31","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/37574e9ad573483a86bb352628fcde3b/view","enriched":false,"history":[]},{"notice_id":"67da9d87d29b4d0abef484bd874d4ea1","title":"Design Build Central Utilities Plant - Reno NV -- Y1NB","solicitation_number":"QSE--36C10F24R50000","notice_type":"p","base_type":"p","posted":"2024-02-12","posted_at":null,"due_at":null,"due_date":null,"cancelled":null,"archived":null,"archive_date":"2025-12-31","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/67da9d87d29b4d0abef484bd874d4ea1/view","enriched":false,"history":[]},{"notice_id":"af1f1be62f504235a66173e158f8a0b9","title":"Design Build Central Utilities Plant - Reno NV -- Y1NB","solicitation_number":"QSE--36C10F24R50000","notice_type":"o","base_type":"p","posted":"2024-05-17","posted_at":null,"due_at":"2024-06-17T21:00:00Z","due_date":"2024-06-17","cancelled":null,"archived":null,"archive_date":"2024-09-30","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/af1f1be62f504235a66173e158f8a0b9/view","enriched":false,"history":[]},{"notice_id":"e6923a838612414593a320815b65fd05","title":"Design Build Central Utilities Plant - Reno NV -- Y1NB","solicitation_number":"QSE--36C10F24R50000","notice_type":"o","base_type":"o","posted":"2024-05-17","posted_at":null,"due_at":"2024-06-17T21:00:00Z","due_date":"2024-06-17","cancelled":null,"archived":null,"archive_date":"2024-09-30","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/e6923a838612414593a320815b65fd05/view","enriched":false,"history":[]},{"notice_id":"c3de84286fe7490db3dbd3d1eadf634e","title":"Design Build Central Utilities Plant - Reno NV -- Y1NB","solicitation_number":"QSE--36C10F24R50000","notice_type":"o","base_type":"o","posted":"2024-06-06","posted_at":null,"due_at":"2024-06-17T21:00:00Z","due_date":"2024-06-17","cancelled":null,"archived":null,"archive_date":"2024-07-17","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/c3de84286fe7490db3dbd3d1eadf634e/view","enriched":false,"history":[]},{"notice_id":"ce428357c42d4da098d943bf21c88646","title":"Design Build Central Utilities Plant - Reno NV -- Y1NB","solicitation_number":"QSE--36C10F24R50000","notice_type":"o","base_type":"o","posted":"2024-06-06","posted_at":null,"due_at":"2024-06-17T21:00:00Z","due_date":"2024-06-17","cancelled":null,"archived":null,"archive_date":"2024-07-17","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/ce428357c42d4da098d943bf21c88646/view","enriched":false,"history":[]},{"notice_id":"483aa2f32d554acb8a8795ed3e0b494c","title":"Design Build Central Utilities Plant - Reno NV -- Y1NB","solicitation_number":"QSE--36C10F24R50000","notice_type":"o","base_type":"o","posted":"2024-06-13","posted_at":null,"due_at":"2024-06-17T21:00:00Z","due_date":"2024-06-17","cancelled":null,"archived":null,"archive_date":"2024-07-30","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/483aa2f32d554acb8a8795ed3e0b494c/view","enriched":false,"history":[]},{"notice_id":"cc11a64a756b46c1814b7a6d7d658021","title":"Design Build Central Utilities Plant - Reno NV -- Y1NB","solicitation_number":"QSE--36C10F24R50000","notice_type":"o","base_type":"o","posted":"2024-06-13","posted_at":null,"due_at":"2024-06-17T21:00:00Z","due_date":"2024-06-17","cancelled":null,"archived":null,"archive_date":"2024-07-30","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/cc11a64a756b46c1814b7a6d7d658021/view","enriched":false,"history":[]},{"notice_id":"20a6f92c7db948f2a832c7fb33635270","title":"Design Build Central Utilities Plant - Reno NV -- Y1NB","solicitation_number":"QSE--36C10F24R50000","notice_type":"o","base_type":"o","posted":"2024-07-18","posted_at":null,"due_at":"2024-08-29T21:00:00Z","due_date":"2024-08-29","cancelled":null,"archived":null,"archive_date":"2024-11-01","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/20a6f92c7db948f2a832c7fb33635270/view","enriched":false,"history":[]},{"notice_id":"89152493c8be42e3bd3f26a44f37fd1e","title":"Design Build Central Utilities Plant - Reno NV -- Y1NB","solicitation_number":"QSE--36C10F24R50000","notice_type":"o","base_type":"o","posted":"2024-07-18","posted_at":null,"due_at":"2024-08-29T21:00:00Z","due_date":"2024-08-29","cancelled":null,"archived":null,"archive_date":"2024-11-01","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/89152493c8be42e3bd3f26a44f37fd1e/view","enriched":false,"history":[]},{"notice_id":"6daa7ba90ec445de8c0d35d0aaa5af52","title":"Design Build Central Utilities Plant - Reno NV -- Y1NB","solicitation_number":"QSE--36C10F24R50000","notice_type":"o","base_type":"o","posted":"2024-07-19","posted_at":null,"due_at":"2024-08-30T01:00:00Z","due_date":"2024-08-29","cancelled":null,"archived":null,"archive_date":"2024-11-01","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/6daa7ba90ec445de8c0d35d0aaa5af52/view","enriched":false,"history":[]},{"notice_id":"232c6b4853d4442182e11fc5daae1ab8","title":"Design Build Construction to Replace Seismically Deficient Boiler Plant, Building 8. VAMC Reno, NV. -- Y1NB","solicitation_number":"QSE--36C10F24R50000","notice_type":"a","base_type":"a","posted":"2025-04-25","posted_at":null,"due_at":null,"due_date":null,"cancelled":null,"archived":null,"archive_date":"2029-05-31","award_number":"QAE--36C10F25C50005","awardee_name":"SGJV2, LLC","amount":"77604919","link_sam":"https://sam.gov/workspace/contract/opp/232c6b4853d4442182e11fc5daae1ab8/view","enriched":false,"history":[]}],"latest_notice_id":"232c6b4853d4442182e11fc5daae1ab8","first_type":"p","notices":[{"dates":{"posted":"2024-02-12"},"links":{"sam":"https://sam.gov/workspace/contract/opp/37574e9ad573483a86bb352628fcde3b/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Design Build Central Utilities Plant - Reno NV -- Y1NB","agency":{"office":{"code":"36C10F","name":"OFFICE OF CONSTRUCTION & FACILITIES MGMT (36C10F)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"20001","city":"WASHINGTON","state":"DC","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2025-12-31","archive_type":"auto_custom"},"contacts":[{"name":"Ashok K. Singh","role":"primary","email":"ashok.singh@va.gov","phone":"202-615-0621"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"37574e9ad573483a86bb352628fcde3b","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"5808b336f7405015f16da7b123eb29c18de76c479f468ee7e8253fac57e3fdd6","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Design Build Central Utilities Plant - Reno NV -- Y1NB Design Build Central Utilities Plant - Reno NV. This announcement shall not be construed as a Request for Proposal (RFP) or a commitment by the U.S. Government. The U.S. Government does not intend to award a contract based on this Industry Day. Classification • Original Set Aside: Service-Disabled Veteran Owned Small Business • Product Service Code: Y1NB – Construction of Heating and Cooling Plants • NAICS Code: 236220 - Commercial and Institutional Building Construction • Place of Performance: VA Sierra Nevada Health Care System, Reno, NV 89502, USA. Description THIS IS A SOURCES SOUGHT NOTICE ONLY. This notice does NOT constitute a request for proposal, request for quote, or invitation for bid. No formal solicitation document exists at this time. We are seeking information for market research purposes only Notice ID: QSE- 36C10F24R50000. The Government will not pay for any information solicited. The VA Office of Construction and Facilities Management (CFM) - Western Region is conducting a market survey to find qualified vendors to provide all labor, materials, tools, equipment, transportation, supervision, coordination, and services necessary to design and build a central utility plant on the VA Sierra Nevada Health Care System campus in Reno, NV 89502. The work includes, but is not limited to: (1) complete Design Build architectural/engineering services to develop final design drawings and construction documents from a previously completed schematic design; (2) construction of a new central utility plant including boilers, chillers, cooling towers, and generators; (3) demolition of the existing boiler plant; and (4) ancillary construction services including parking/pavement, connection to existing utilities, commissioning, et al. This project is intended to be a Design Build contract procurement. The proposed NAICS code 236220 is applicable to this acquisition, with a size standard of $45.0 million. The anticipated Magnitude of Construction is between $20,000,000 and $50,000,000. The anticipated Period of Performance is 1,460 Calendar Days from the Notice to Proceed. Interested participants must pre-register for Industry Day as a security requirement to visit VA facility by sending an email title your email as follows: “Pre-Industry Day Question, Western Region. Design Build Central Utilities Plant, 36C10F24R50000 (Company Name).” Instructions: The VA Contracting Officer (CO) will consider responses received for this Sources Sought Notice, along with any other market research that is conducted, when determining the Government’s appropriate acquisition strategy. Pursuant to 38 U.S.C. 8127(d), CO’s must set aside all acquisitions for SDVOSBs (Service-Disabled Veteran Owned Small Businesses) or VOSBs (Veteran Owned Small Businesses) whenever there is a reasonable expectation of receiving two or more offers/quotes from eligible, capable and verified firms, and that an award can be made at a fair and reasonable price that offers best value to the Government. However, if responses from qualified firms prove inadequate, an alternate set-aside or full and open competition may be considered. In order to be considered eligible for an SDVOSB or VOSB Set-Aside, interested firms must confirm in their response to this Sources Sought Notice that they will be able to comply with all the following criteria: (1) VA Acquisition Regulation (VAAR) 819.7003 “Eligibility”; (2) VAAR clause 852.219-73 “VA Notice of Total Set-Aside for Verified Service-Disabled Veteran-Owned Small Businesses” or VAAR clause 852.219-74 “VA Notice of Total Set-Aside for Verified Veteran-Owned Small Businesses”; and (3) VAAR clause 852.219-75 “VA Notice of Limitations on Subcontracting Certificate of Compliance for Services and Construction”. All interested parties should respond in writing via email to Ashok.Singh@va.gov, and Christopher.Kotas@va.gov No telephone inquiries will be accepted. Your response is required by 10:00 AM PDT on ¬¬¬November 1, 2023. Your email title shall be as follows: “Pre-Industry Day Question, Western Region. Design Build Central Utilities Plant, 36C10F24R50000, (Company Name).” In addition to providing your positive interest in this project, please include the following in your response to this Notice: (1) Company name and address; (2) Point of contact with email and phone number; (3) SAM Unique Entity ID number and evidence of current SAM registration (see https://www.sam.gov for more information); (4) Company socio-economic size ( SDVOSB, VOSB); (5) NAICS code; (6) Brief capabilities statement, to include experience with contracts of similar scope and magnitude; and (7) Information demonstrating your company has the capacity to complete this project, to include available bonding capacity. In addition to this information, please include a response to the following question in your submission: What additional information would you require in order to provide a proposal for this project? Limit your submission to 1page with 11point font Times New Roman. An Industry Day for this project is scheduled on November 9, 2023, at the Sierra Nevada Health Care System, Reno, NV. The purpose of this Industry Day is to provide prospective proposers the following information: (1) General Project Overview and Scope; (2) How to Obtain the Solicitation; and (3) Procurement Process. A project site walk will be included in the agenda. The Sierra Nevada Health Care System is located at 975 Kirman Avenue, Reno, NV 89502. The Industry Day presentation is scheduled to begin at 9 am in the Tahoe Room, and is anticipated to conclude at noon, followed by a site tour. Time Session Title Notes 0900 Registration and Industry Networking Visitor name list from pre-registration 0930 Welcome and Introductions 1000 Project Overview, general sessions Design Build, SDVOSB Set aside, 1100 Question and Answer Period Pre-industry day questions followed by impromptu Q&A 1200 Formal Event Close 1230 Site tour breakout The following are the Industry Day Rules of Engagement (ROE): - The Government intends to use this forum to communicate requirements. - No sales pitches allowed from industry, no giveaways. - No cameras, tape recorders, or other reproduction devices are allowed. This announcement shall not be construed as a Request for Proposal (RFP) or a commitment by the U.S. Government. The U.S. Government does not intend to award a contract based on this Industry Day.","origin":"extract"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"QSE--36C10F24R50000","place_of_performance":{"zip":"89502","city":{"name":"Reno"},"state":{"code":"NV"},"street":"The Sierra Nevada Health Care System; 975 Kirman Avenue, 0","country":{"code":"USA"}},"product_service_code":"Y1NB"},{"dates":{"posted":"2024-02-12"},"links":{"sam":"https://sam.gov/workspace/contract/opp/67da9d87d29b4d0abef484bd874d4ea1/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Design Build Central Utilities Plant - Reno NV -- Y1NB","agency":{"office":{"code":"36C10F","name":"OFFICE OF CONSTRUCTION & FACILITIES MGMT (36C10F)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"20001","city":"WASHINGTON","state":"DC","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2025-12-31","archive_type":"auto_custom"},"contacts":[{"name":"Ashok K. Singh","role":"primary","email":"ashok.singh@va.gov","phone":"202-615-0621"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"67da9d87d29b4d0abef484bd874d4ea1","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"590fbb161ec9aff974236cf078f438d4f3c5f70ee309d99a69b11faa80d9e250","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Design Build Central Utilities Plant - Reno NV -- Y1NB Design Build Central Utilities Plant - Reno NV. This announcement shall not be construed as a Request for Proposal (RFP) or a commitment by the U.S. Government. The U.S. Government does not intend to award a contract based on this Industry Day. Classification • Original Set Aside: Service-Disabled Veteran Owned Small Business • Product Service Code: Y1NB – Construction of Heating and Cooling Plants • NAICS Code: 236220 - Commercial and Institutional Building Construction • Place of Performance: VA Sierra Nevada Health Care System, Reno, NV 89502, USA. Description THIS IS A SOURCES SOUGHT NOTICE ONLY. This notice does NOT constitute a request for proposal, request for quote, or invitation for bid. No formal solicitation document exists at this time. We are seeking information for market research purposes only Notice ID: QSE- 36C10F24R50000. The Government will not pay for any information solicited. The VA Office of Construction and Facilities Management (CFM) - Western Region is conducting a market survey to find qualified vendors to provide all labor, materials, tools, equipment, transportation, supervision, coordination, and services necessary to design and build a central utility plant on the VA Sierra Nevada Health Care System campus in Reno, NV 89502. The work includes, but is not limited to: (1) complete Design Build architectural/engineering services to develop final design drawings and construction documents from a previously completed schematic design; (2) construction of a new central utility plant including boilers, chillers, cooling towers, and generators; (3) demolition of the existing boiler plant; and (4) ancillary construction services including parking/pavement, connection to existing utilities, commissioning, et al. This project is intended to be a Design Build contract procurement. The proposed NAICS code 236220 is applicable to this acquisition, with a size standard of $45.0 million. The anticipated Magnitude of Construction is between $20,000,000 and $50,000,000. The anticipated Period of Performance is 1,460 Calendar Days from the Notice to Proceed. Interested participants must pre-register for Industry Day as a security requirement to visit VA facility by sending an email title your email as follows: “Pre-Industry Day Question, Western Region. Design Build Central Utilities Plant, 36C10F24R50000 (Company Name).” Instructions: The VA Contracting Officer (CO) will consider responses received for this Sources Sought Notice, along with any other market research that is conducted, when determining the Government’s appropriate acquisition strategy. Pursuant to 38 U.S.C. 8127(d), CO’s must set aside all acquisitions for SDVOSBs (Service-Disabled Veteran Owned Small Businesses) or VOSBs (Veteran Owned Small Businesses) whenever there is a reasonable expectation of receiving two or more offers/quotes from eligible, capable and verified firms, and that an award can be made at a fair and reasonable price that offers best value to the Government. However, if responses from qualified firms prove inadequate, an alternate set-aside or full and open competition may be considered. In order to be considered eligible for an SDVOSB or VOSB Set-Aside, interested firms must confirm in their response to this Sources Sought Notice that they will be able to comply with all the following criteria: (1) VA Acquisition Regulation (VAAR) 819.7003 “Eligibility”; (2) VAAR clause 852.219-73 “VA Notice of Total Set-Aside for Verified Service-Disabled Veteran-Owned Small Businesses” or VAAR clause 852.219-74 “VA Notice of Total Set-Aside for Verified Veteran-Owned Small Businesses”; and (3) VAAR clause 852.219-75 “VA Notice of Limitations on Subcontracting Certificate of Compliance for Services and Construction”. All interested parties should respond in writing via email to Ashok.Singh@va.gov, and Christopher.Kotas@va.gov No telephone inquiries will be accepted. Your response is required by 10:00 AM PDT on ¬¬¬November 1, 2023. Your email title shall be as follows: “Pre-Industry Day Question, Western Region. Design Build Central Utilities Plant, 36C10F24R50000, (Company Name).” In addition to providing your positive interest in this project, please include the following in your response to this Notice: (1) Company name and address; (2) Point of contact with email and phone number; (3) SAM Unique Entity ID number and evidence of current SAM registration (see https://www.sam.gov for more information); (4) Company socio-economic size ( SDVOSB, VOSB); (5) NAICS code; (6) Brief capabilities statement, to include experience with contracts of similar scope and magnitude; and (7) Information demonstrating your company has the capacity to complete this project, to include available bonding capacity. In addition to this information, please include a response to the following question in your submission: What additional information would you require in order to provide a proposal for this project? Limit your submission to 1page with 11point font Times New Roman. An Industry Day for this project is scheduled on November 9, 2023, at the Sierra Nevada Health Care System, Reno, NV. The purpose of this Industry Day is to provide prospective proposers the following information: (1) General Project Overview and Scope; (2) How to Obtain the Solicitation; and (3) Procurement Process. A project site walk will be included in the agenda. The Sierra Nevada Health Care System is located at 975 Kirman Avenue, Reno, NV 89502. The Industry Day presentation is scheduled to begin at 9 am in the Tahoe Room, and is anticipated to conclude at noon, followed by a site tour. Time Session Title Notes 0900 Registration and Industry Networking Visitor name list from pre-registration 0930 Welcome and Introductions 1000 Project Overview, general sessions Design Build, SDVOSB Set aside, 1100 Question and Answer Period Pre-industry day questions followed by impromptu Q&A 1200 Formal Event Close 1230 Site tour breakout The following are the Industry Day Rules of Engagement (ROE): - The Government intends to use this forum to communicate requirements. - No sales pitches allowed from industry, no giveaways. - No cameras, tape recorders, or other reproduction devices are allowed. This announcement shall not be construed as a Request for Proposal (RFP) or a commitment by the U.S. Government. The U.S. Government does not intend to award a contract based on this Industry Day.","origin":"extract"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"QSE--36C10F24R50000","place_of_performance":{"zip":"89502","city":{"name":"Reno"},"state":{"code":"NV"},"street":"The Sierra Nevada Health Care System; 975 Kirman Avenue, 0","country":{"code":"USA"}},"product_service_code":"Y1NB"},{"dates":{"posted":"2024-05-17","response_deadline":{"raw":"2024-06-17T21:00:00+00:00","utc":"2024-06-17T21:00:00Z","date":"2024-06-17","time":"21:00:00","utc_offset_seconds":0}},"links":{"sam":"https://sam.gov/workspace/contract/opp/af1f1be62f504235a66173e158f8a0b9/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Design Build Central Utilities Plant - Reno NV -- Y1NB","agency":{"office":{"code":"36C10F","name":"OFFICE OF CONSTRUCTION & FACILITIES MGMT (36C10F)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"20001","city":"WASHINGTON","state":"DC","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-09-30","archive_type":"auto_custom"},"contacts":[{"name":"Ashok K. Singh","role":"primary","email":"ashok.singh@va.gov","phone":"202-615-0621","title":"Contracting Officer"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"af1f1be62f504235a66173e158f8a0b9","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"d54f6823f82e6275418b0021b768f45579ec3dca57a3edd0625415f447d4db70","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Design Build Central Utilities Plant - Reno NV -- Y1NB Design Build Central Utilities Plant - Reno NV Scope of Work – Replace Seismically Deficient Boiler Plant, Building 8 The contractor will provide all labor, material, and equipment necessary to complete a final project design along with complete physical construction necessary to deliver a new Central Utility Plant (CUP) at the VA Sierra Nevada Health Care System (VASNHCS) in Reno, Nevada. The project scope includes associated work activities consisting of, but not limited to, improvements at an existing gravel park lot, demolition of the facility’s current utility building, the Boiler Plant, Building 8, conversion of the Boiler Plant location into a parking lot, and installation of a bulk oxygen storage room with associated tanks and equipment. More specifically, the contractor will design, construct and achieve the following activities in listed order; 1) improvements to an existing gravel parking lot to pave, stripe, drain and light the lot for the facility’s use during project duration. The lot will also include an emergency call system which matches that in other similar lots at the facility. 2) build an approximately 11,000 GSF CUP structure housing the boilers, chillers, cooling towers, and the bulk oxygen system to provide steam, heating and cooling for the entire VASNHCS campus. Additionally, as the current facility main power feed runs through the courtyard of the existing Boiler Plant, the project will also include all electrical work required to relocate the electrical service from the present location to a new location within the CUP. 3) thoroughly test all equipment and systems in the CUP to assure complete functionality of the systems and equipment. Once testing has been completed and accepted by the VA, make final connection of all utility systems to existing utility feeds on the east side of Kirman Avenue at the location where the utility feeds currently exit the Boiler Plant. 4) demolish the existing Boiler Plant once the CUP is fully operational and providing all utility services to the facility. This scope all includes removal of hazardous materials prior to demolition of the building. 5) convert the Boiler Plant location, once demolition is complete, into a paved, striped surface level parking lot, including lighting and proper drainage. 6) re-stripe the lot improved per item 1 above to meet VA criteria for the proper allocation of standard and handicap stalls. For informational purposes only and to provide prospective offerors with a greater understanding of the Government’s requirements, accompanying this RFP solicitation are the following documents: (1) conceptual drawings indicating project siting, phasing, and preliminary design; (2) narratives describing technical approach to the project; and (3) supporting design specifications and documents. Note this preliminary design information is provided for information only. The Design Build Contractor selected for this project is under no obligation to incorporate this conceptual design information into their final project design. The contractor will provide all required professional design services within all required disciplines necessary to complete the above referenced scope. All disciplines shall have a current professional license issued by the State of Nevada or equivalent document from another state. Although a geotechnical report is being provided, the contractor will be responsible for completing their own geotechnical analysis as part of project design development. All construction activities will be accomplished by firms which have a current license issued by the Nevada State Contractors Board or equivalent document from another state . All design documents are to be developed in accordance with the VA Technical Design Library, which can be accessed at https://www.cfm.va.gov/til/. The final design and construction of the project will fully incorporate the requirements listed in the referenced site. No deviations will be allowed unless prior approval is provided by the VA Contracting Officer.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"QSE--36C10F24R50000","place_of_performance":{"zip":"89502","city":{"name":"Reno"},"state":{"code":"NV"},"street":"; 975 Kirman Ave 0","country":{"code":"USA"}},"product_service_code":"Y1NB"},{"dates":{"posted":"2024-05-17","response_deadline":{"raw":"2024-06-17T21:00:00+00:00","utc":"2024-06-17T21:00:00Z","date":"2024-06-17","time":"21:00:00","utc_offset_seconds":0}},"links":{"sam":"https://sam.gov/workspace/contract/opp/e6923a838612414593a320815b65fd05/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Design Build Central Utilities Plant - Reno NV -- Y1NB","agency":{"office":{"code":"36C10F","name":"OFFICE OF CONSTRUCTION & FACILITIES MGMT (36C10F)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"20001","city":"WASHINGTON","state":"DC","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-09-30","archive_type":"auto_custom"},"contacts":[{"name":"Ashok K. Singh","role":"primary","email":"ashok.singh@va.gov","phone":"202-615-0621","title":"Contracting Officer"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"e6923a838612414593a320815b65fd05","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"9b936b87fdf2b1bc909a3657432daf26e832a9bc38bee0448fbeb946788e3906","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Design Build Central Utilities Plant - Reno NV -- Y1NB Design Build Central Utilities Plant - Reno NV Scope of Work – Replace Seismically Deficient Boiler Plant, Building 8 The contractor will provide all labor, material, and equipment necessary to complete a final project design along with complete physical construction necessary to deliver a new Central Utility Plant (CUP) at the VA Sierra Nevada Health Care System (VASNHCS) in Reno, Nevada. The project scope includes associated work activities consisting of, but not limited to, improvements at an existing gravel park lot, demolition of the facility’s current utility building, the Boiler Plant, Building 8, conversion of the Boiler Plant location into a parking lot, and installation of a bulk oxygen storage room with associated tanks and equipment. More specifically, the contractor will design, construct and achieve the following activities in listed order; 1) improvements to an existing gravel parking lot to pave, stripe, drain and light the lot for the facility’s use during project duration. The lot will also include an emergency call system which matches that in other similar lots at the facility. 2) build an approximately 11,000 GSF CUP structure housing the boilers, chillers, cooling towers, and the bulk oxygen system to provide steam, heating and cooling for the entire VASNHCS campus. Additionally, as the current facility main power feed runs through the courtyard of the existing Boiler Plant, the project will also include all electrical work required to relocate the electrical service from the present location to a new location within the CUP. 3) thoroughly test all equipment and systems in the CUP to assure complete functionality of the systems and equipment. Once testing has been completed and accepted by the VA, make final connection of all utility systems to existing utility feeds on the east side of Kirman Avenue at the location where the utility feeds currently exit the Boiler Plant. 4) demolish the existing Boiler Plant once the CUP is fully operational and providing all utility services to the facility. This scope all includes removal of hazardous materials prior to demolition of the building. 5) convert the Boiler Plant location, once demolition is complete, into a paved, striped surface level parking lot, including lighting and proper drainage. 6) re-stripe the lot improved per item 1 above to meet VA criteria for the proper allocation of standard and handicap stalls. For informational purposes only and to provide prospective offerors with a greater understanding of the Government’s requirements, accompanying this RFP solicitation are the following documents: (1) conceptual drawings indicating project siting, phasing, and preliminary design; (2) narratives describing technical approach to the project; and (3) supporting design specifications and documents. Note this preliminary design information is provided for information only. The Design Build Contractor selected for this project is under no obligation to incorporate this conceptual design information into their final project design. The contractor will provide all required professional design services within all required disciplines necessary to complete the above referenced scope. All disciplines shall have a current professional license issued by the State of Nevada or equivalent document from another state. Although a geotechnical report is being provided, the contractor will be responsible for completing their own geotechnical analysis as part of project design development. All construction activities will be accomplished by firms which have a current license issued by the Nevada State Contractors Board or equivalent document from another state . All design documents are to be developed in accordance with the VA Technical Design Library, which can be accessed at https://www.cfm.va.gov/til/. The final design and construction of the project will fully incorporate the requirements listed in the referenced site. No deviations will be allowed unless prior approval is provided by the VA Contracting Officer.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"QSE--36C10F24R50000","place_of_performance":{"zip":"89502","city":{"name":"Reno"},"state":{"code":"NV"},"street":"; 975 Kirman Ave 0","country":{"code":"USA"}},"product_service_code":"Y1NB"},{"dates":{"posted":"2024-06-06","response_deadline":{"raw":"2024-06-17T21:00:00+00:00","utc":"2024-06-17T21:00:00Z","date":"2024-06-17","time":"21:00:00","utc_offset_seconds":0}},"links":{"sam":"https://sam.gov/workspace/contract/opp/c3de84286fe7490db3dbd3d1eadf634e/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Design Build Central Utilities Plant - Reno NV -- Y1NB","agency":{"office":{"code":"36C10F","name":"OFFICE OF CONSTRUCTION & FACILITIES MGMT (36C10F)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"20001","city":"WASHINGTON","state":"DC","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-07-17","archive_type":"auto_custom"},"contacts":[{"name":"Ashok K. Singh","role":"primary","email":"ashok.singh@va.gov","phone":"202-615-0621","title":"Contracting Officer"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"c3de84286fe7490db3dbd3d1eadf634e","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"a553a65eded6095d5b9feacf2ecfc960486d2111fe4324fabb8e01e07d9960e2","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Design Build Central Utilities Plant - Reno NV -- Y1NB Design Build Central Utilities Plant - Reno NV Scope of Work – Replace Seismically Deficient Boiler Plant, Building 8 The contractor will provide all labor, material, and equipment necessary to complete a final project design along with complete physical construction necessary to deliver a new Central Utility Plant (CUP) at the VA Sierra Nevada Health Care System (VASNHCS) in Reno, Nevada. The project scope includes associated work activities consisting of, but not limited to, improvements at an existing gravel park lot, demolition of the facility’s current utility building, the Boiler Plant, Building 8, conversion of the Boiler Plant location into a parking lot, and installation of a bulk oxygen storage room with associated tanks and equipment. More specifically, the contractor will design, construct and achieve the following activities in listed order; 1) improvements to an existing gravel parking lot to pave, stripe, drain and light the lot for the facility’s use during project duration. The lot will also include an emergency call system which matches that in other similar lots at the facility. 2) build an approximately 11,000 GSF CUP structure housing the boilers, chillers, cooling towers, and the bulk oxygen system to provide steam, heating and cooling for the entire VASNHCS campus. Additionally, as the current facility main power feed runs through the courtyard of the existing Boiler Plant, the project will also include all electrical work required to relocate the electrical service from the present location to a new location within the CUP. 3) thoroughly test all equipment and systems in the CUP to assure complete functionality of the systems and equipment. Once testing has been completed and accepted by the VA, make final connection of all utility systems to existing utility feeds on the east side of Kirman Avenue at the location where the utility feeds currently exit the Boiler Plant. 4) demolish the existing Boiler Plant once the CUP is fully operational and providing all utility services to the facility. This scope all includes removal of hazardous materials prior to demolition of the building. 5) convert the Boiler Plant location, once demolition is complete, into a paved, striped surface level parking lot, including lighting and proper drainage. 6) re-stripe the lot improved per item 1 above to meet VA criteria for the proper allocation of standard and handicap stalls. For informational purposes only and to provide prospective offerors with a greater understanding of the Government’s requirements, accompanying this RFP solicitation are the following documents: (1) conceptual drawings indicating project siting, phasing, and preliminary design; (2) narratives describing technical approach to the project; and (3) supporting design specifications and documents. Note this preliminary design information is provided for information only. The Design Build Contractor selected for this project is under no obligation to incorporate this conceptual design information into their final project design. The contractor will provide all required professional design services within all required disciplines necessary to complete the above referenced scope. All disciplines shall have a current professional license issued by the State of Nevada or equivalent document from another state. Although a geotechnical report is being provided, the contractor will be responsible for completing their own geotechnical analysis as part of project design development. All construction activities will be accomplished by firms which have a current license issued by the Nevada State Contractors Board or equivalent document from another state . All design documents are to be developed in accordance with the VA Technical Design Library, which can be accessed at https://www.cfm.va.gov/til/. The final design and construction of the project will fully incorporate the requirements listed in the referenced site. No deviations will be allowed unless prior approval is provided by the VA Contracting Officer.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"QSE--36C10F24R50000","place_of_performance":{"zip":"89502","city":{"name":"Reno"},"state":{"code":"NV"},"street":"; 975 Kirman Ave 0","country":{"code":"USA"}},"product_service_code":"Y1NB"},{"dates":{"posted":"2024-06-06","response_deadline":{"raw":"2024-06-17T21:00:00+00:00","utc":"2024-06-17T21:00:00Z","date":"2024-06-17","time":"21:00:00","utc_offset_seconds":0}},"links":{"sam":"https://sam.gov/workspace/contract/opp/ce428357c42d4da098d943bf21c88646/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Design Build Central Utilities Plant - Reno NV -- Y1NB","agency":{"office":{"code":"36C10F","name":"OFFICE OF CONSTRUCTION & FACILITIES MGMT (36C10F)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"20001","city":"WASHINGTON","state":"DC","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-07-17","archive_type":"auto_custom"},"contacts":[{"name":"Ashok K. Singh","role":"primary","email":"ashok.singh@va.gov","phone":"202-615-0621","title":"Contracting Officer"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"ce428357c42d4da098d943bf21c88646","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"4e15f1595dd3f96a7b62537a00763ee6c8da03064524d31c9661231d71e74a66","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Design Build Central Utilities Plant - Reno NV -- Y1NB Design Build Central Utilities Plant - Reno NV Scope of Work – Replace Seismically Deficient Boiler Plant, Building 8 The contractor will provide all labor, material, and equipment necessary to complete a final project design along with complete physical construction necessary to deliver a new Central Utility Plant (CUP) at the VA Sierra Nevada Health Care System (VASNHCS) in Reno, Nevada. The project scope includes associated work activities consisting of, but not limited to, improvements at an existing gravel park lot, demolition of the facility’s current utility building, the Boiler Plant, Building 8, conversion of the Boiler Plant location into a parking lot, and installation of a bulk oxygen storage room with associated tanks and equipment. More specifically, the contractor will design, construct and achieve the following activities in listed order; 1) improvements to an existing gravel parking lot to pave, stripe, drain and light the lot for the facility’s use during project duration. The lot will also include an emergency call system which matches that in other similar lots at the facility. 2) build an approximately 11,000 GSF CUP structure housing the boilers, chillers, cooling towers, and the bulk oxygen system to provide steam, heating and cooling for the entire VASNHCS campus. Additionally, as the current facility main power feed runs through the courtyard of the existing Boiler Plant, the project will also include all electrical work required to relocate the electrical service from the present location to a new location within the CUP. 3) thoroughly test all equipment and systems in the CUP to assure complete functionality of the systems and equipment. Once testing has been completed and accepted by the VA, make final connection of all utility systems to existing utility feeds on the east side of Kirman Avenue at the location where the utility feeds currently exit the Boiler Plant. 4) demolish the existing Boiler Plant once the CUP is fully operational and providing all utility services to the facility. This scope all includes removal of hazardous materials prior to demolition of the building. 5) convert the Boiler Plant location, once demolition is complete, into a paved, striped surface level parking lot, including lighting and proper drainage. 6) re-stripe the lot improved per item 1 above to meet VA criteria for the proper allocation of standard and handicap stalls. For informational purposes only and to provide prospective offerors with a greater understanding of the Government’s requirements, accompanying this RFP solicitation are the following documents: (1) conceptual drawings indicating project siting, phasing, and preliminary design; (2) narratives describing technical approach to the project; and (3) supporting design specifications and documents. Note this preliminary design information is provided for information only. The Design Build Contractor selected for this project is under no obligation to incorporate this conceptual design information into their final project design. The contractor will provide all required professional design services within all required disciplines necessary to complete the above referenced scope. All disciplines shall have a current professional license issued by the State of Nevada or equivalent document from another state. Although a geotechnical report is being provided, the contractor will be responsible for completing their own geotechnical analysis as part of project design development. All construction activities will be accomplished by firms which have a current license issued by the Nevada State Contractors Board or equivalent document from another state . All design documents are to be developed in accordance with the VA Technical Design Library, which can be accessed at https://www.cfm.va.gov/til/. The final design and construction of the project will fully incorporate the requirements listed in the referenced site. No deviations will be allowed unless prior approval is provided by the VA Contracting Officer.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"QSE--36C10F24R50000","place_of_performance":{"zip":"89502","city":{"name":"Reno"},"state":{"code":"NV"},"street":"; 975 Kirman Ave 0","country":{"code":"USA"}},"product_service_code":"Y1NB"},{"dates":{"posted":"2024-06-13","response_deadline":{"raw":"2024-06-17T21:00:00+00:00","utc":"2024-06-17T21:00:00Z","date":"2024-06-17","time":"21:00:00","utc_offset_seconds":0}},"links":{"sam":"https://sam.gov/workspace/contract/opp/483aa2f32d554acb8a8795ed3e0b494c/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Design Build Central Utilities Plant - Reno NV -- Y1NB","agency":{"office":{"code":"36C10F","name":"OFFICE OF CONSTRUCTION & FACILITIES MGMT (36C10F)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"20001","city":"WASHINGTON","state":"DC","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-07-30","archive_type":"auto_custom"},"contacts":[{"name":"Ashok K. Singh","role":"primary","email":"ashok.singh@va.gov","phone":"202-615-0621","title":"Contracting Officer"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"483aa2f32d554acb8a8795ed3e0b494c","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"47636970fa1df924117f9bc5cbcb5a0c4a55e864da284ffaab84fc0cf8ce0f88","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Design Build Central Utilities Plant - Reno NV -- Y1NB Design Build Central Utilities Plant - Reno NV Scope of Work – Replace Seismically Deficient Boiler Plant, Building 8 The contractor will provide all labor, material, and equipment necessary to complete a final project design along with complete physical construction necessary to deliver a new Central Utility Plant (CUP) at the VA Sierra Nevada Health Care System (VASNHCS) in Reno, Nevada. The project scope includes associated work activities consisting of, but not limited to, improvements at an existing gravel park lot, demolition of the facility’s current utility building, the Boiler Plant, Building 8, conversion of the Boiler Plant location into a parking lot, and installation of a bulk oxygen storage room with associated tanks and equipment. More specifically, the contractor will design, construct and achieve the following activities in listed order; 1) improvements to an existing gravel parking lot to pave, stripe, drain and light the lot for the facility’s use during project duration. The lot will also include an emergency call system which matches that in other similar lots at the facility. 2) build an approximately 11,000 GSF CUP structure housing the boilers, chillers, cooling towers, and the bulk oxygen system to provide steam, heating and cooling for the entire VASNHCS campus. Additionally, as the current facility main power feed runs through the courtyard of the existing Boiler Plant, the project will also include all electrical work required to relocate the electrical service from the present location to a new location within the CUP. 3) thoroughly test all equipment and systems in the CUP to assure complete functionality of the systems and equipment. Once testing has been completed and accepted by the VA, make final connection of all utility systems to existing utility feeds on the east side of Kirman Avenue at the location where the utility feeds currently exit the Boiler Plant. 4) demolish the existing Boiler Plant once the CUP is fully operational and providing all utility services to the facility. This scope all includes removal of hazardous materials prior to demolition of the building. 5) convert the Boiler Plant location, once demolition is complete, into a paved, striped surface level parking lot, including lighting and proper drainage. 6) re-stripe the lot improved per item 1 above to meet VA criteria for the proper allocation of standard and handicap stalls. For informational purposes only and to provide prospective offerors with a greater understanding of the Government’s requirements, accompanying this RFP solicitation are the following documents: (1) conceptual drawings indicating project siting, phasing, and preliminary design; (2) narratives describing technical approach to the project; and (3) supporting design specifications and documents. Note this preliminary design information is provided for information only. The Design Build Contractor selected for this project is under no obligation to incorporate this conceptual design information into their final project design. The contractor will provide all required professional design services within all required disciplines necessary to complete the above referenced scope. All disciplines shall have a current professional license issued by the State of Nevada or equivalent document from another state. Although a geotechnical report is being provided, the contractor will be responsible for completing their own geotechnical analysis as part of project design development. All construction activities will be accomplished by firms which have a current license issued by the Nevada State Contractors Board or equivalent document from another state . All design documents are to be developed in accordance with the VA Technical Design Library, which can be accessed at https://www.cfm.va.gov/til/. The final design and construction of the project will fully incorporate the requirements listed in the referenced site. No deviations will be allowed unless prior approval is provided by the VA Contracting Officer.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"QSE--36C10F24R50000","place_of_performance":{"zip":"89502","city":{"name":"Reno"},"state":{"code":"NV"},"street":"; 975 Kirman Ave 0","country":{"code":"USA"}},"product_service_code":"Y1NB"},{"dates":{"posted":"2024-06-13","response_deadline":{"raw":"2024-06-17T21:00:00+00:00","utc":"2024-06-17T21:00:00Z","date":"2024-06-17","time":"21:00:00","utc_offset_seconds":0}},"links":{"sam":"https://sam.gov/workspace/contract/opp/cc11a64a756b46c1814b7a6d7d658021/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Design Build Central Utilities Plant - Reno NV -- Y1NB","agency":{"office":{"code":"36C10F","name":"OFFICE OF CONSTRUCTION & FACILITIES MGMT (36C10F)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"20001","city":"WASHINGTON","state":"DC","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-07-30","archive_type":"auto_custom"},"contacts":[{"name":"Ashok K. Singh","role":"primary","email":"ashok.singh@va.gov","phone":"202-615-0621","title":"Contracting Officer"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"cc11a64a756b46c1814b7a6d7d658021","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"bbae205ee08050257491f2ac746665715b0f9fd6f6d0a500eeda9a05af6ab0db","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Design Build Central Utilities Plant - Reno NV -- Y1NB Design Build Central Utilities Plant - Reno NV Scope of Work – Replace Seismically Deficient Boiler Plant, Building 8 The contractor will provide all labor, material, and equipment necessary to complete a final project design along with complete physical construction necessary to deliver a new Central Utility Plant (CUP) at the VA Sierra Nevada Health Care System (VASNHCS) in Reno, Nevada. The project scope includes associated work activities consisting of, but not limited to, improvements at an existing gravel park lot, demolition of the facility’s current utility building, the Boiler Plant, Building 8, conversion of the Boiler Plant location into a parking lot, and installation of a bulk oxygen storage room with associated tanks and equipment. More specifically, the contractor will design, construct and achieve the following activities in listed order; 1) improvements to an existing gravel parking lot to pave, stripe, drain and light the lot for the facility’s use during project duration. The lot will also include an emergency call system which matches that in other similar lots at the facility. 2) build an approximately 11,000 GSF CUP structure housing the boilers, chillers, cooling towers, and the bulk oxygen system to provide steam, heating and cooling for the entire VASNHCS campus. Additionally, as the current facility main power feed runs through the courtyard of the existing Boiler Plant, the project will also include all electrical work required to relocate the electrical service from the present location to a new location within the CUP. 3) thoroughly test all equipment and systems in the CUP to assure complete functionality of the systems and equipment. Once testing has been completed and accepted by the VA, make final connection of all utility systems to existing utility feeds on the east side of Kirman Avenue at the location where the utility feeds currently exit the Boiler Plant. 4) demolish the existing Boiler Plant once the CUP is fully operational and providing all utility services to the facility. This scope all includes removal of hazardous materials prior to demolition of the building. 5) convert the Boiler Plant location, once demolition is complete, into a paved, striped surface level parking lot, including lighting and proper drainage. 6) re-stripe the lot improved per item 1 above to meet VA criteria for the proper allocation of standard and handicap stalls. For informational purposes only and to provide prospective offerors with a greater understanding of the Government’s requirements, accompanying this RFP solicitation are the following documents: (1) conceptual drawings indicating project siting, phasing, and preliminary design; (2) narratives describing technical approach to the project; and (3) supporting design specifications and documents. Note this preliminary design information is provided for information only. The Design Build Contractor selected for this project is under no obligation to incorporate this conceptual design information into their final project design. The contractor will provide all required professional design services within all required disciplines necessary to complete the above referenced scope. All disciplines shall have a current professional license issued by the State of Nevada or equivalent document from another state. Although a geotechnical report is being provided, the contractor will be responsible for completing their own geotechnical analysis as part of project design development. All construction activities will be accomplished by firms which have a current license issued by the Nevada State Contractors Board or equivalent document from another state . All design documents are to be developed in accordance with the VA Technical Design Library, which can be accessed at https://www.cfm.va.gov/til/. The final design and construction of the project will fully incorporate the requirements listed in the referenced site. No deviations will be allowed unless prior approval is provided by the VA Contracting Officer.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"QSE--36C10F24R50000","place_of_performance":{"zip":"89502","city":{"name":"Reno"},"state":{"code":"NV"},"street":"; 975 Kirman Ave 0","country":{"code":"USA"}},"product_service_code":"Y1NB"},{"dates":{"posted":"2024-07-18","response_deadline":{"raw":"2024-08-29T21:00:00+00:00","utc":"2024-08-29T21:00:00Z","date":"2024-08-29","time":"21:00:00","utc_offset_seconds":0}},"links":{"sam":"https://sam.gov/workspace/contract/opp/20a6f92c7db948f2a832c7fb33635270/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Design Build Central Utilities Plant - Reno NV -- Y1NB","agency":{"office":{"code":"36C10F","name":"OFFICE OF CONSTRUCTION & FACILITIES MGMT (36C10F)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"20001","city":"WASHINGTON","state":"DC","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-11-01","archive_type":"auto_custom"},"contacts":[{"name":"Ashok K. Singh","role":"primary","email":"ashok.singh@va.gov","phone":"202-615-0621","title":"Contracting Officer"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"20a6f92c7db948f2a832c7fb33635270","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"2c876032dc1dfe6e17441b28a8ec28f359f8d78fb9580ee6ce7d9a5775a9bcda","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Design Build Central Utilities Plant - Reno NV -- Y1NB Design Build Central Utilities Plant - Reno NV Scope of Work – Replace Seismically Deficient Boiler Plant, Building 8 The contractor will provide all labor, material, and equipment necessary to complete a final project design along with complete physical construction necessary to deliver a new Central Utility Plant (CUP) at the VA Sierra Nevada Health Care System (VASNHCS) in Reno, Nevada. The project scope includes associated work activities consisting of, but not limited to, improvements at an existing gravel park lot, demolition of the facility’s current utility building, the Boiler Plant, Building 8, conversion of the Boiler Plant location into a parking lot, and installation of a bulk oxygen storage room with associated tanks and equipment. More specifically, the contractor will design, construct and achieve the following activities in listed order; 1) improvements to an existing gravel parking lot to pave, stripe, drain and light the lot for the facility’s use during project duration. The lot will also include an emergency call system which matches that in other similar lots at the facility. 2) build an approximately 11,000 GSF CUP structure housing the boilers, chillers, cooling towers, and the bulk oxygen system to provide steam, heating and cooling for the entire VASNHCS campus. Additionally, as the current facility main power feed runs through the courtyard of the existing Boiler Plant, the project will also include all electrical work required to relocate the electrical service from the present location to a new location within the CUP. 3) thoroughly test all equipment and systems in the CUP to assure complete functionality of the systems and equipment. Once testing has been completed and accepted by the VA, make final connection of all utility systems to existing utility feeds on the east side of Kirman Avenue at the location where the utility feeds currently exit the Boiler Plant. 4) demolish the existing Boiler Plant once the CUP is fully operational and providing all utility services to the facility. This scope all includes removal of hazardous materials prior to demolition of the building. 5) convert the Boiler Plant location, once demolition is complete, into a paved, striped surface level parking lot, including lighting and proper drainage. 6) re-stripe the lot improved per item 1 above to meet VA criteria for the proper allocation of standard and handicap stalls. For informational purposes only and to provide prospective offerors with a greater understanding of the Government’s requirements, accompanying this RFP solicitation are the following documents: (1) conceptual drawings indicating project siting, phasing, and preliminary design; (2) narratives describing technical approach to the project; and (3) supporting design specifications and documents. Note this preliminary design information is provided for information only. The Design Build Contractor selected for this project is under no obligation to incorporate this conceptual design information into their final project design. The contractor will provide all required professional design services within all required disciplines necessary to complete the above referenced scope. All disciplines shall have a current professional license issued by the State of Nevada or equivalent document from another state. Although a geotechnical report is being provided, the contractor will be responsible for completing their own geotechnical analysis as part of project design development. All construction activities will be accomplished by firms which have a current license issued by the Nevada State Contractors Board or equivalent document from another state . All design documents are to be developed in accordance with the VA Technical Design Library, which can be accessed at https://www.cfm.va.gov/til/. The final design and construction of the project will fully incorporate the requirements listed in the referenced site. No deviations will be allowed unless prior approval is provided by the VA Contracting Officer.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"QSE--36C10F24R50000","place_of_performance":{"zip":"89502","city":{"name":"Reno"},"state":{"code":"NV"},"street":"; 975 Kirman Ave 0","country":{"code":"USA"}},"product_service_code":"Y1NB"},{"dates":{"posted":"2024-07-18","response_deadline":{"raw":"2024-08-29T21:00:00+00:00","utc":"2024-08-29T21:00:00Z","date":"2024-08-29","time":"21:00:00","utc_offset_seconds":0}},"links":{"sam":"https://sam.gov/workspace/contract/opp/89152493c8be42e3bd3f26a44f37fd1e/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Design Build Central Utilities Plant - Reno NV -- Y1NB","agency":{"office":{"code":"36C10F","name":"OFFICE OF CONSTRUCTION & FACILITIES MGMT (36C10F)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"20001","city":"WASHINGTON","state":"DC","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-11-01","archive_type":"auto_custom"},"contacts":[{"name":"Ashok K. Singh","role":"primary","email":"ashok.singh@va.gov","phone":"202-615-0621","title":"Contracting Officer"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"89152493c8be42e3bd3f26a44f37fd1e","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"6d66fcc036001eaf9689a57ba7b5efe9f7a085d858afb2eff4942738d3ad84d5","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Design Build Central Utilities Plant - Reno NV -- Y1NB Design Build Central Utilities Plant - Reno NV Scope of Work – Replace Seismically Deficient Boiler Plant, Building 8 The contractor will provide all labor, material, and equipment necessary to complete a final project design along with complete physical construction necessary to deliver a new Central Utility Plant (CUP) at the VA Sierra Nevada Health Care System (VASNHCS) in Reno, Nevada. The project scope includes associated work activities consisting of, but not limited to, improvements at an existing gravel park lot, demolition of the facility’s current utility building, the Boiler Plant, Building 8, conversion of the Boiler Plant location into a parking lot, and installation of a bulk oxygen storage room with associated tanks and equipment. More specifically, the contractor will design, construct and achieve the following activities in listed order; 1) improvements to an existing gravel parking lot to pave, stripe, drain and light the lot for the facility’s use during project duration. The lot will also include an emergency call system which matches that in other similar lots at the facility. 2) build an approximately 11,000 GSF CUP structure housing the boilers, chillers, cooling towers, and the bulk oxygen system to provide steam, heating and cooling for the entire VASNHCS campus. Additionally, as the current facility main power feed runs through the courtyard of the existing Boiler Plant, the project will also include all electrical work required to relocate the electrical service from the present location to a new location within the CUP. 3) thoroughly test all equipment and systems in the CUP to assure complete functionality of the systems and equipment. Once testing has been completed and accepted by the VA, make final connection of all utility systems to existing utility feeds on the east side of Kirman Avenue at the location where the utility feeds currently exit the Boiler Plant. 4) demolish the existing Boiler Plant once the CUP is fully operational and providing all utility services to the facility. This scope all includes removal of hazardous materials prior to demolition of the building. 5) convert the Boiler Plant location, once demolition is complete, into a paved, striped surface level parking lot, including lighting and proper drainage. 6) re-stripe the lot improved per item 1 above to meet VA criteria for the proper allocation of standard and handicap stalls. For informational purposes only and to provide prospective offerors with a greater understanding of the Government’s requirements, accompanying this RFP solicitation are the following documents: (1) conceptual drawings indicating project siting, phasing, and preliminary design; (2) narratives describing technical approach to the project; and (3) supporting design specifications and documents. Note this preliminary design information is provided for information only. The Design Build Contractor selected for this project is under no obligation to incorporate this conceptual design information into their final project design. The contractor will provide all required professional design services within all required disciplines necessary to complete the above referenced scope. All disciplines shall have a current professional license issued by the State of Nevada or equivalent document from another state. Although a geotechnical report is being provided, the contractor will be responsible for completing their own geotechnical analysis as part of project design development. All construction activities will be accomplished by firms which have a current license issued by the Nevada State Contractors Board or equivalent document from another state . All design documents are to be developed in accordance with the VA Technical Design Library, which can be accessed at https://www.cfm.va.gov/til/. The final design and construction of the project will fully incorporate the requirements listed in the referenced site. No deviations will be allowed unless prior approval is provided by the VA Contracting Officer.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"QSE--36C10F24R50000","place_of_performance":{"zip":"89502","city":{"name":"Reno"},"state":{"code":"NV"},"street":"; 975 Kirman Ave 0","country":{"code":"USA"}},"product_service_code":"Y1NB"},{"dates":{"posted":"2024-07-19","response_deadline":{"raw":"2024-08-29T21:00:00-04:00","utc":"2024-08-30T01:00:00Z","date":"2024-08-29","time":"21:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/6daa7ba90ec445de8c0d35d0aaa5af52/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Design Build Central Utilities Plant - Reno NV -- Y1NB","agency":{"office":{"code":"36C10F","name":"OFFICE OF CONSTRUCTION & FACILITIES MGMT (36C10F)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"20001","city":"WASHINGTON","state":"DC","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-11-01","archive_type":"auto_custom"},"contacts":[{"name":"Ashok K. Singh","role":"primary","email":"ashok.singh@va.gov","phone":"202-615-0621","title":"Contracting Officer"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"6daa7ba90ec445de8c0d35d0aaa5af52","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"0bb127959114be03585a8ff55cd0bfbcebb7f9bc60cec8d98c7c0c5b9746b071","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Design Build Central Utilities Plant - Reno NV -- Y1NB Design Build Central Utilities Plant - Reno NV Scope of Work – Replace Seismically Deficient Boiler Plant, Building 8 The contractor will provide all labor, material, and equipment necessary to complete a final project design along with complete physical construction necessary to deliver a new Central Utility Plant (CUP) at the VA Sierra Nevada Health Care System (VASNHCS) in Reno, Nevada. The project scope includes associated work activities consisting of, but not limited to, improvements at an existing gravel park lot, demolition of the facility’s current utility building, the Boiler Plant, Building 8, conversion of the Boiler Plant location into a parking lot, and installation of a bulk oxygen storage room with associated tanks and equipment. More specifically, the contractor will design, construct and achieve the following activities in listed order; 1) improvements to an existing gravel parking lot to pave, stripe, drain and light the lot for the facility’s use during project duration. The lot will also include an emergency call system which matches that in other similar lots at the facility. 2) build an approximately 11,000 GSF CUP structure housing the boilers, chillers, cooling towers, and the bulk oxygen system to provide steam, heating and cooling for the entire VASNHCS campus. Additionally, as the current facility main power feed runs through the courtyard of the existing Boiler Plant, the project will also include all electrical work required to relocate the electrical service from the present location to a new location within the CUP. 3) thoroughly test all equipment and systems in the CUP to assure complete functionality of the systems and equipment. Once testing has been completed and accepted by the VA, make final connection of all utility systems to existing utility feeds on the east side of Kirman Avenue at the location where the utility feeds currently exit the Boiler Plant. 4) demolish the existing Boiler Plant once the CUP is fully operational and providing all utility services to the facility. This scope all includes removal of hazardous materials prior to demolition of the building. 5) convert the Boiler Plant location, once demolition is complete, into a paved, striped surface level parking lot, including lighting and proper drainage. 6) re-stripe the lot improved per item 1 above to meet VA criteria for the proper allocation of standard and handicap stalls. For informational purposes only and to provide prospective offerors with a greater understanding of the Government’s requirements, accompanying this RFP solicitation are the following documents: (1) conceptual drawings indicating project siting, phasing, and preliminary design; (2) narratives describing technical approach to the project; and (3) supporting design specifications and documents. Note this preliminary design information is provided for information only. The Design Build Contractor selected for this project is under no obligation to incorporate this conceptual design information into their final project design. The contractor will provide all required professional design services within all required disciplines necessary to complete the above referenced scope. All disciplines shall have a current professional license issued by the State of Nevada or equivalent document from another state. Although a geotechnical report is being provided, the contractor will be responsible for completing their own geotechnical analysis as part of project design development. All construction activities will be accomplished by firms which have a current license issued by the Nevada State Contractors Board or equivalent document from another state . All design documents are to be developed in accordance with the VA Technical Design Library, which can be accessed at https://www.cfm.va.gov/til/. The final design and construction of the project will fully incorporate the requirements listed in the referenced site. No deviations will be allowed unless prior approval is provided by the VA Contracting Officer.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"QSE--36C10F24R50000","place_of_performance":{"zip":"89502","city":{"name":"Reno"},"state":{"code":"NV"},"street":"; 975 Kirman Ave 0","country":{"code":"USA"}},"product_service_code":"Y1NB"},{"award":{"date":"2025-04-25","amount":"77604919","number":"QAE--36C10F25C50005","awardee":{"raw":"SGJV2, LLC","name":"SGJV2, LLC"}},"dates":{"posted":"2025-04-25","award_date":"2025-04-25"},"links":{"sam":"https://sam.gov/workspace/contract/opp/232c6b4853d4442182e11fc5daae1ab8/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"Design Build Construction to Replace Seismically Deficient Boiler Plant, Building 8. VAMC Reno, NV. -- Y1NB","agency":{"office":{"code":"36C10F","name":"OFFICE OF CONSTRUCTION & FACILITIES MGMT (36C10F)"},"subtier":{"code":"3600","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"department":{"code":"036","name":"VETERANS AFFAIRS, DEPARTMENT OF"},"office_address":{"zip":"20001","city":"WASHINGTON","state":"DC","country":"USA"},"organization_type":"OFFICE"},"status":{"active":true,"archive_date":"2029-05-31","archive_type":"auto_custom"},"contacts":[{"name":"Ashok K. Singh","role":"primary","email":"ashok.singh@va.gov","phone":"202-615-0621","title":"Contracting Officer"}],"base_type":{"code":"a","label":"Award Notice"},"notice_id":"232c6b4853d4442182e11fc5daae1ab8","set_aside":{"code":"SDVOSBC","label":"Service-Disabled Veteran-Owned Small Business Set-Aside (FAR 19.14)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"3f59209463433eba6899e195a597c64d-29\"","fetched_at":"2026-09-16T17:45:38.712931Z","row_sha256":"039e89dbb4aa58f8325bc30dace6aed946e93b049125aba6c4bd8378afa06ccf","last_modified":"2026-09-16T03:30:52Z"},"updated_at":"2026-09-16T17:45:38.712931Z","first_seen_at":"2026-09-16T17:45:38.712931Z"},"description":{"text":"Design Build Construction to Replace Seismically Deficient Boiler Plant, Building 8. VAMC Reno, NV. -- Y1NB Replace Seismically Deficient Boiler Plant, Building 8, VAMC Reno, NV. Design Build Construction Solicitation for New CUP. The work includes, but is not limited to: (1) complete Design Build architectural/engineering services to develop final design drawings and construction documents from a previously completed schematic design; (2) construction of a new central utility plant including boilers, chillers, cooling towers, and generators; (3) demolition of the existing boiler plant; and (4) ancillary construction services including parking/pavement, connection to existing utilities, commissioning.","origin":"extract"},"notice_type":{"code":"a","label":"Award Notice"},"schema_version":1,"solicitation_number":"QSE--36C10F24R50000","place_of_performance":{"zip":"89502","city":{"name":"Reno"},"state":{"code":"NV"},"street":"; 975 Kirman Ave 0","country":{"code":"USA"}},"product_service_code":"Y1NB"}],"due_at":"2024-08-30T01:00:00Z","due_date":"2024-08-29","closes_at":"2024-08-30T01:00:00Z","awardable":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10F","office_name":"OFFICE OF CONSTRUCTION & FACILITIES MGMT (36C10F)","state":"NV","county":"32031","county_name":"Washoe County","city":"3260600","city_name":"Reno","country":"USA","winner_key":"J1A9ES828FV5","amount":"77604919","linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z","principal_notice_id":"232c6b4853d4442182e11fc5daae1ab8","description":{"text":"Design Build Construction to Replace Seismically Deficient Boiler Plant, Building 8. VAMC Reno, NV. -- Y1NB Replace Seismically Deficient Boiler Plant, Building 8, VAMC Reno, NV. Design Build Construction Solicitation for New CUP. The work includes, but is not limited to: (1) complete Design Build architectural/engineering services to develop final design drawings and construction documents from a previously completed schematic design; (2) construction of a new central utility plant including boilers, chillers, cooling towers, and generators; (3) demolition of the existing boiler plant; and (4) ancillary construction services including parking/pavement, connection to existing utilities, commissioning.","html":null,"origin":"extract"},"contacts":[{"name":"Ashok K. Singh","role":"primary","email":"ashok.singh@va.gov","phone":"202-615-0621","title":"Contracting Officer"}],"place_of_performance":{"zip":"89502","city":{"name":"Reno"},"state":{"code":"NV"},"street":"; 975 Kirman Ave 0","country":{"code":"USA"}},"office_address":{"zip":"20001","city":"WASHINGTON","state":"DC","country":"USA"},"naics_codes":["236220"],"award":{"date":"2025-04-25","amount":"77604919","number":"QAE--36C10F25C50005","awardee":{"raw":"SGJV2, LLC","name":"SGJV2, LLC"}},"attachments":[],"awards":[],"related":[{"key":"36C10F26R0024","latest_notice_id":"c5baf4fdab144f3c9981788842f754e1","title":"X1DB--South Palm Beach County, FL OPC 56,076 ANSI/BOMA","solicitation_number":"36C10F26R0024","notice_type":"k","first_type":"k","first_posted":"2026-07-24","last_posted":"2026-08-20","notices":6,"due_at":"2026-09-18T21:00:00Z","due_date":"2026-09-18","closes_at":"2026-09-18T21:00:00Z","awardable":true,"open":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10F","office_name":"OFFICE OF CONSTRUCTION & FACILITIES MGMT (36C10F)","naics":"531120","psc":"X1DB","set_aside":null,"state":"FL","county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"36C10F26R0052","latest_notice_id":"eda1d273c7da49928d5daed2383426ba","title":"X1DB--Canton OH Outpatient Clinic 62,784 ANSI/BOMA RLP Extension","solicitation_number":"36C10F26R0052","notice_type":"k","first_type":"k","first_posted":"2026-07-23","last_posted":"2026-09-11","notices":5,"due_at":"2026-09-28T21:00:00Z","due_date":"2026-09-28","closes_at":"2026-09-28T21:00:00Z","awardable":true,"open":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10F","office_name":"OFFICE OF CONSTRUCTION & FACILITIES MGMT (36C10F)","naics":"531120","psc":"X1DB","set_aside":null,"state":"OH","county":"39151","county_name":"Stark County","city":"3912000","city_name":"Canton","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"36C10F26Q0103","latest_notice_id":"3075333ce7574cce93fb2d190c04194a","title":"X1DB--New Braunfels, TX OPC | EOI","solicitation_number":"36C10F26Q0103","notice_type":"p","first_type":"p","first_posted":"2026-08-28","last_posted":"2026-08-28","notices":1,"due_at":"2026-09-28T21:00:00Z","due_date":"2026-09-28","closes_at":"2026-09-28T21:00:00Z","awardable":true,"open":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10F","office_name":"OFFICE OF CONSTRUCTION & FACILITIES MGMT (36C10F)","naics":"531120","psc":"X1DB","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"36C10F25R0035","latest_notice_id":"d0d96711f332410f89a1203c888c85b2","title":"X1DB--Port St. Lucie, Fl. Outpatient Clinic 142,811 ANSI/BOMA Amendment","solicitation_number":"36C10F25R0035","notice_type":"k","first_type":"k","first_posted":"2025-05-28","last_posted":"2026-08-31","notices":4,"due_at":"2026-09-30T20:00:00Z","due_date":"2026-09-30","closes_at":"2026-09-30T20:00:00Z","awardable":true,"open":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10F","office_name":"OFFICE OF CONSTRUCTION & FACILITIES MGMT (36C10F)","naics":"531120","psc":"X1DB","set_aside":"SDVOSBC","state":"FL","county":"12111","county_name":"St. Lucie County","city":"1258715","city_name":"Port St. Lucie","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"36C10F26Q0106","latest_notice_id":"ca4dc72c61fa40369370a3d04162f32a","title":"Veteran Affairs N. Virginia Western Prince William Co, Gainesville/Manassas_ OPC","solicitation_number":"36C10F26Q0106","notice_type":"p","first_type":"p","first_posted":"2026-09-03","last_posted":"2026-09-03","notices":1,"due_at":"2026-10-02T21:00:00Z","due_date":"2026-10-02","closes_at":"2026-10-02T21:00:00Z","awardable":true,"open":true,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C10F","office_name":"OFFICE OF CONSTRUCTION & FACILITIES MGMT (36C10F)","naics":"53112","psc":"X1DB","set_aside":null,"state":"VA","county":"51153","county_name":"Prince William County","city":"5130176","city_name":"Gainesville","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"}]}