{"canonical":"https://abierto.us/opportunities/pr16327481","key":"PR16327481","url":"https://abierto.us/opportunities/pr16327481","title":"Hydrogen Generator for Gas Chromatography","solicitation_number":"PR16327481","notice_type":"k","open":true,"removed":false,"removed_at":null,"response_deadline":"2026-11-13T15:00:00Z","first_posted":"2026-10-28","last_posted":"2026-10-28","department":"STATE, DEPARTMENT OF","subagency":"STATE, DEPARTMENT OF","office":"U.S. EMBASSY KINGSTON","naics":"334516","psc":"6640","set_aside":null,"place_state":null,"place_scope":"overseas","site":null,"place_state_source":null,"place_evidence":"JAMAICA","place_county":null,"place_county_name":null,"place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"678d50a6258e459980ffb46d0ba82fc9","title":"Hydrogen Generator for Gas Chromatography","solicitation_number":"PR16327481","notice_type":"k","base_type":"k","posted":"2026-10-28","posted_at":"2026-10-28T14:53:33.846Z","due_at":"2026-11-13T15:00:00Z","due_date":"2026-11-13","cancelled":false,"archived":false,"archive_date":"2026-11-28","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/678d50a6258e459980ffb46d0ba82fc9/view","enriched":true,"history":[{"index":1,"title":"Hydrogen Generator for Gas Chromatography","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-28T14:53:33.846Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"678d50a6258e459980ffb46d0ba82fc9","solicitation_number":"PR16327481"}]}],"latest_notice_id":"678d50a6258e459980ffb46d0ba82fc9","first_type":"k","notices":[{"dates":{"posted":"2026-10-28","posted_at":"2026-10-28T14:53:33.846Z","created_at":"2026-10-26T15:27:04.330Z","modified_at":"2026-10-28T14:53:33.851Z","response_deadline":{"raw":"2026-11-13T10:00:00-05:00","utc":"2026-11-13T15:00:00Z","date":"2026-11-13","time":"10:00:00","timezone":"America/Bogota","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/678d50a6258e459980ffb46d0ba82fc9/view"},"naics":{"codes":["334516"],"primary":"334516"},"title":"Hydrogen Generator for Gas Chromatography","agency":{"office":{"code":"19JM37","name":"U.S. EMBASSY KINGSTON"},"subtier":{"code":"1900","name":"STATE, DEPARTMENT OF"},"department":{"code":"019","name":"STATE, DEPARTMENT OF"},"office_address":{"zip":"20520","city":"WASHINGTON","state":"DC","country":"USA"},"organization_id":"100183209","organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-11-28","archive_type":"auto15"},"history":[{"index":1,"title":"Hydrogen Generator for Gas Chromatography","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-28T14:53:33.846Z","notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"request_type":"submit","opportunity_id":"678d50a6258e459980ffb46d0ba82fc9","solicitation_number":"PR16327481"}],"contacts":[{"name":"U.S. Embassy Kingston Procurement Office","role":"primary","email":"kingstonquotes@state.gov","phone":"8767026000"},{"name":"Handel Blake","role":"secondary","email":"BlakeHA@state.gov","phone":"8767026393"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"678d50a6258e459980ffb46d0ba82fc9","lineage_id":"678d50a6258e459980ffb46d0ba82fc9","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-29T04:43:53.303145690Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"6cfa182f59c94f6f903e7b14049289b7-27\"","fetched_at":"2026-10-29T04:12:35.895465707Z","row_sha256":"f4d90e71ca51b9642014e6fbfab31c66b37e717505c719d3df136b5b505da193","last_modified":"2026-10-29T03:30:32Z"},"updated_at":"2026-10-29T04:43:53.303145690Z","first_seen_at":"2026-10-29T04:12:35.895465707Z"},"description":{"html":"<p>The United States Embassy seeks qualified and authorized reseller of one (1) on demand laboratory hydrogen generator, plus installation, gas distribution, commissioning, training and warranty services, as described below:</p>\n\n<p><strong>PEAK SCIENTIFIC INTURA H2 250 HYDROGEN GENERATOR (AUTO-FILL), WITH MANUFACTURER&#39;S STANDARD WARRANTY</strong> QUANTITY: 1</p>\n\n<ul>\n\t<li>Peak Scientific part number: 3305698-0-02 (auto-fill)</li>\n\t<li>Flow rate up to 250 cc/min; 99.99999% purity; output pressure up to 175 psi</li>\n\t<li>Standard warranty: 12-month comprehensive warranty and 36-month PEM cell warranty both starting at Government acceptance</li>\n\t<li>Operator&#39;s manual and warranty certificate in English</li>\n</ul>\n\n<p><strong>PEAK INTURA H2 ANNUAL SERVICE KIT</strong> QUANTITY: 1&nbsp;</p>\n\n<ul>\n\t<li>Peak Scientific part number: 3306178</li>\n</ul>\n\n<p><strong>ON-SITE INSTALLATION, GAS DISTRIBUTION, COMMISSIONING AND TRAINING</strong> QUANTITY: 1</p>\n\n<ul>\n\t<li>Firm-fixed price. No extra labor-hour charges.</li>\n\t<li>Performed at IFSLM, Kingston, Jamaica, by Peak-certified technicians, in English.</li>\n\t<li>Supply and install all clean, GC-grade tubing, fittings, tees/manifolds and point-of-use regulators to deliver hydrogen to the Agilent 7890A GC/5975C VL MSD and the Agilent 7890A GC-FID, which sit next to each other.</li>\n\t<li>Connect the generator to the lab&#39;s existing DI water supply for auto-fill. Leak-test every connection.</li>\n\t<li>Show that each instrument works on generator-supplied hydrogen, including the switch from helium to hydrogen carrier gas on the 5975C system.</li>\n\t<li>Provide <strong>one (1) day</strong> of on-site operator training for approximately <strong>ten (10) </strong>IFSLM staff, covering operation, routine maintenance, water quality requirements and hydrogen safety, including safe hydrogen use in the GC oven and MSD.</li>\n\t<li>Provide an installation and commissioning report.</li>\n</ul>\n\n<p><strong>004 &ndash; SHIPPING TO KINGSTON, JAMAICA</strong> QUANTITY: 1&nbsp;</p>\n\n<ul>\n\t<li>FOB Destination: <strong>U.S. Embassy Kingston, 142 Old Hope Road&nbsp;Kingston 6&nbsp;Jamaica</strong>, including all customs, brokerage, insurance and freight charges for the items to be delivered door to door (DTP).</li>\n\t<li>Contractor bears risk of loss until Government acceptance at the embassy.</li>\n</ul>","text":"The United States Embassy seeks qualified and authorized reseller of one (1) on demand laboratory hydrogen generator, plus installation, gas distribution, commissioning, training and warranty services, as described below:\n\nPEAK SCIENTIFIC INTURA H2 250 HYDROGEN GENERATOR (AUTO-FILL), WITH MANUFACTURER'S STANDARD WARRANTY QUANTITY: 1\n\n• Peak Scientific part number: 3305698-0-02 (auto-fill)\n\n• Flow rate up to 250 cc/min; 99.99999% purity; output pressure up to 175 psi\n\n• Standard warranty: 12-month comprehensive warranty and 36-month PEM cell warranty both starting at Government acceptance\n\n• Operator's manual and warranty certificate in English\n\nPEAK INTURA H2 ANNUAL SERVICE KIT QUANTITY: 1\n\n• Peak Scientific part number: 3306178\n\nON-SITE INSTALLATION, GAS DISTRIBUTION, COMMISSIONING AND TRAINING QUANTITY: 1\n\n• Firm-fixed price. No extra labor-hour charges.\n\n• Performed at IFSLM, Kingston, Jamaica, by Peak-certified technicians, in English.\n\n• Supply and install all clean, GC-grade tubing, fittings, tees/manifolds and point-of-use regulators to deliver hydrogen to the Agilent 7890A GC/5975C VL MSD and the Agilent 7890A GC-FID, which sit next to each other.\n\n• Connect the generator to the lab's existing DI water supply for auto-fill. Leak-test every connection.\n\n• Show that each instrument works on generator-supplied hydrogen, including the switch from helium to hydrogen carrier gas on the 5975C system.\n\n• Provide one (1) day of on-site operator training for approximately ten (10) IFSLM staff, covering operation, routine maintenance, water quality requirements and hydrogen safety, including safe hydrogen use in the GC oven and MSD.\n\n• Provide an installation and commissioning report.\n\n004 – SHIPPING TO KINGSTON, JAMAICA QUANTITY: 1\n\n• FOB Destination: U.S. Embassy Kingston, 142 Old Hope Road Kingston 6 Jamaica, including all customs, brokerage, insurance and freight charges for the items to be delivered door to door (DTP).\n\n• Contractor bears risk of loss until Government acceptance at the embassy.","origin":"detail"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"PR16327481","place_of_performance":{"city":{"code":"Kingston","name":"Kingston"},"state":{"code":"JM-02","name":"Saint Andrew"},"country":{"code":"JAM","name":"JAMAICA"}},"product_service_code":"6640"}],"due_at":"2026-11-13T15:00:00Z","due_date":"2026-11-13","closes_at":"2026-11-13T15:00:00Z","awardable":true,"dept_key":"d-019","dept_name":"STATE, DEPARTMENT OF","sub_key":"s-1900","sub_name":"STATE, DEPARTMENT OF","office_key":"o-19JM37","office_name":"U.S. EMBASSY KINGSTON","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":"JAM","state_source":null,"state_evidence":"JAMAICA","site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-10-29T04:15:54.363094Z","principal_notice_id":"678d50a6258e459980ffb46d0ba82fc9","description":{"text":"The United States Embassy seeks qualified and authorized reseller of one (1) on demand laboratory hydrogen generator, plus installation, gas distribution, commissioning, training and warranty services, as described below:\n\nPEAK SCIENTIFIC INTURA H2 250 HYDROGEN GENERATOR (AUTO-FILL), WITH MANUFACTURER'S STANDARD WARRANTY QUANTITY: 1\n\n• Peak Scientific part number: 3305698-0-02 (auto-fill)\n\n• Flow rate up to 250 cc/min; 99.99999% purity; output pressure up to 175 psi\n\n• Standard warranty: 12-month comprehensive warranty and 36-month PEM cell warranty both starting at Government acceptance\n\n• Operator's manual and warranty certificate in English\n\nPEAK INTURA H2 ANNUAL SERVICE KIT QUANTITY: 1\n\n• Peak Scientific part number: 3306178\n\nON-SITE INSTALLATION, GAS DISTRIBUTION, COMMISSIONING AND TRAINING QUANTITY: 1\n\n• Firm-fixed price. No extra labor-hour charges.\n\n• Performed at IFSLM, Kingston, Jamaica, by Peak-certified technicians, in English.\n\n• Supply and install all clean, GC-grade tubing, fittings, tees/manifolds and point-of-use regulators to deliver hydrogen to the Agilent 7890A GC/5975C VL MSD and the Agilent 7890A GC-FID, which sit next to each other.\n\n• Connect the generator to the lab's existing DI water supply for auto-fill. Leak-test every connection.\n\n• Show that each instrument works on generator-supplied hydrogen, including the switch from helium to hydrogen carrier gas on the 5975C system.\n\n• Provide one (1) day of on-site operator training for approximately ten (10) IFSLM staff, covering operation, routine maintenance, water quality requirements and hydrogen safety, including safe hydrogen use in the GC oven and MSD.\n\n• Provide an installation and commissioning report.\n\n004 – SHIPPING TO KINGSTON, JAMAICA QUANTITY: 1\n\n• FOB Destination: U.S. Embassy Kingston, 142 Old Hope Road Kingston 6 Jamaica, including all customs, brokerage, insurance and freight charges for the items to be delivered door to door (DTP).\n\n• Contractor bears risk of loss until Government acceptance at the embassy.","html":"<p>The United States Embassy seeks qualified and authorized reseller of one (1) on demand laboratory hydrogen generator, plus installation, gas distribution, commissioning, training and warranty services, as described below:</p>\n\n<p><strong>PEAK SCIENTIFIC INTURA H2 250 HYDROGEN GENERATOR (AUTO-FILL), WITH MANUFACTURER&#39;S STANDARD WARRANTY</strong> QUANTITY: 1</p>\n\n<ul>\n\t<li>Peak Scientific part number: 3305698-0-02 (auto-fill)</li>\n\t<li>Flow rate up to 250 cc/min; 99.99999% purity; output pressure up to 175 psi</li>\n\t<li>Standard warranty: 12-month comprehensive warranty and 36-month PEM cell warranty both starting at Government acceptance</li>\n\t<li>Operator&#39;s manual and warranty certificate in English</li>\n</ul>\n\n<p><strong>PEAK INTURA H2 ANNUAL SERVICE KIT</strong> QUANTITY: 1&nbsp;</p>\n\n<ul>\n\t<li>Peak Scientific part number: 3306178</li>\n</ul>\n\n<p><strong>ON-SITE INSTALLATION, GAS DISTRIBUTION, COMMISSIONING AND TRAINING</strong> QUANTITY: 1</p>\n\n<ul>\n\t<li>Firm-fixed price. No extra labor-hour charges.</li>\n\t<li>Performed at IFSLM, Kingston, Jamaica, by Peak-certified technicians, in English.</li>\n\t<li>Supply and install all clean, GC-grade tubing, fittings, tees/manifolds and point-of-use regulators to deliver hydrogen to the Agilent 7890A GC/5975C VL MSD and the Agilent 7890A GC-FID, which sit next to each other.</li>\n\t<li>Connect the generator to the lab&#39;s existing DI water supply for auto-fill. Leak-test every connection.</li>\n\t<li>Show that each instrument works on generator-supplied hydrogen, including the switch from helium to hydrogen carrier gas on the 5975C system.</li>\n\t<li>Provide <strong>one (1) day</strong> of on-site operator training for approximately <strong>ten (10) </strong>IFSLM staff, covering operation, routine maintenance, water quality requirements and hydrogen safety, including safe hydrogen use in the GC oven and MSD.</li>\n\t<li>Provide an installation and commissioning report.</li>\n</ul>\n\n<p><strong>004 &ndash; SHIPPING TO KINGSTON, JAMAICA</strong> QUANTITY: 1&nbsp;</p>\n\n<ul>\n\t<li>FOB Destination: <strong>U.S. Embassy Kingston, 142 Old Hope Road&nbsp;Kingston 6&nbsp;Jamaica</strong>, including all customs, brokerage, insurance and freight charges for the items to be delivered door to door (DTP).</li>\n\t<li>Contractor bears risk of loss until Government acceptance at the embassy.</li>\n</ul>","origin":"detail"},"contacts":[{"name":"U.S. Embassy Kingston Procurement Office","role":"primary","email":"kingstonquotes@state.gov","phone":"8767026000"},{"name":"Handel Blake","role":"secondary","email":"BlakeHA@state.gov","phone":"8767026393"}],"place_of_performance":{"city":{"code":"Kingston","name":"Kingston"},"state":{"code":"JM-02","name":"Saint Andrew"},"country":{"code":"JAM","name":"JAMAICA"}},"office_address":{"zip":"20520","city":"WASHINGTON","state":"DC","country":"USA"},"naics_codes":["334516"],"award":null,"attachments":[{"resource_id":"97b737dfad904571aea5b0f610aae5ed","name":"PR16327481_RFQ_Hydrogen Generator.pdf","kind":"file","mime_type":".pdf","size_bytes":307421,"posted_at":"2026-10-28T14:53:33.846Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/97b737dfad904571aea5b0f610aae5ed/download","mirrored":false}],"awards":[],"related":[{"key":"19JM3727Q0002","latest_notice_id":"79b69696ceed4090b5e4db5a94cb31be","title":"Trenching, Conduit and Ground-well Installation","solicitation_number":"19JM3727Q0002","notice_type":"o","first_type":"o","first_posted":"2026-10-28","last_posted":"2026-10-28","notices":1,"due_at":"2026-11-25T19:00:00Z","due_date":"2026-11-25","closes_at":"2026-11-25T19:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-019","dept_name":"STATE, DEPARTMENT OF","sub_key":"s-1900","sub_name":"STATE, DEPARTMENT OF","office_key":"o-19JM37","office_name":"U.S. EMBASSY KINGSTON","naics":"238910","psc":"N038","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":"JAM","place_scope":"overseas","state_source":null,"state_evidence":"JAMAICA","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"}],"similar_open":[{"key":"36C24226Q0949","latest_notice_id":"c441f167dbb843118b1277de8ef04205","title":"6640--Electrophoresis Testing for the Albany, Buffalo, and Syracuse VA Medical Centers","solicitation_number":"36C24226Q0949","notice_type":"k","first_type":"k","first_posted":"2026-09-29","last_posted":"2026-10-26","notices":3,"due_at":"2026-11-02T20:00:00Z","due_date":"2026-11-02","closes_at":"2026-11-02T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C242","office_name":"242-NETWORK CONTRACT OFFICE 02 (36C242)","naics":"334516","psc":"6640","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6640)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-27T03:50:29.852134Z"},{"key":"N6893626SIMACQD5550000062","latest_notice_id":"6f1e150e39d548e4b27adde4c65349a6","title":"Volumetric KF Titrator","solicitation_number":"N6893626SIMACQD5550000062","notice_type":"p","first_type":"p","first_posted":"2026-10-29","last_posted":"2026-10-29","notices":1,"due_at":"2026-11-03T18:00:00Z","due_date":"2026-11-03","closes_at":"2026-11-03T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N68936","office_name":"NAVAL AIR WARFARE CENTER","naics":"334516","psc":"6640","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6640)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-30T03:41:17.879115Z"},{"key":"80NSSC27948373Q","latest_notice_id":"435951b824aa47d5b633ac4e05bfb0b3","title":"170 Composite Cylinders for KSC SCAPE Operations","solicitation_number":"80NSSC27948373Q","notice_type":"o","first_type":"o","first_posted":"2026-10-28","last_posted":"2026-10-28","notices":1,"due_at":"2026-11-04T20:30:00Z","due_date":"2026-11-04","closes_at":"2026-11-04T20:30:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-080","dept_name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION","sub_key":"s-8000","sub_name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION","office_key":"o-80NSSC","office_name":"NASA SHARED SERVICES CENTER","naics":"334516","psc":"6640","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 6640)","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"}],"similar_open_total":38}