# Dehydrator / Air Dryer

Canonical: https://abierto.us/opportunities/n6660426q0022

- Solicitation number: N6660426Q0022
- Notice type: Combined synopsis and solicitation
- Status: Closed. Deadline was October 7, 2025 at 2:00 PM EDT
- Department: Department of the Navy
- Agency: Department of the Navy
- Contracting office: NUWC Div Newport (N66604)
- NAICS: 333994 Industrial Process Furnace and Oven Manufacturing
- Product or service code: 4440 Driers, Dehydrators, and Anhydrators
- Set-aside: Total small business set-aside
- Place of performance: Newport, Rhode Island
- County: Newport County (FIPS 44005). https://abierto.us/counties/newport-county-ri-44005
- City: Newport. https://abierto.us/cities/newport-ri-4449960
- First posted: October 2, 2025
- Last posted: October 6, 2025
- SAM.gov: https://sam.gov/workspace/contract/opp/6009589cedfe46ada4d163f9303dfb25/view

## Description

Please see attached RFQ for all details about this opportunity.

**AMENDMENT 0001:** 10/02/2025 Solicitation amended to answer industry questions.

**QUESTION:** We need to know the INLET pressure of the compressed air. We can mount a pressure regulator so you can control it to your required pressure;

**Outlet Pressure Range:** 5–15 PSIG.

**ANSWER:** The units produce the pressure, there is not a specification for an inlet pressure. We need a minimum output of 15PSI with 4 ports.

**QUESTION:** Is there a technical contact / requestor I could communicate with to better understand the application?

**ANSWER:** All questions may be send to maria.d.diaz-sotomayor.civ@us.navy.mil QUESTION: Is there a specific process to submit these (quotes)?

**ANSWER:** Quotes shall be submitted via email to maria.d.diaz-sotomayor.civ@us.navy.mil AMENDMENT 0002: 10/06/2025 Solicitation amended to answer industry questions.

**QUESTION:** The greatly varying Output capacity, listed as 350-550 SCFD. Usually capacities for compressed air are listed as CFM or SCFM, so I do not know if this was a typo or not. Also, if the spec is for SCFM, the capacity figures of 350-550 SFCM covers 3 different size models.

**ANSWER:** Normal 350 SCFD, or 0.24 SCFM.

**QUESTION:** What is the dewpoint requirement? -40 or -100F ANSWER: No dewpoint requirement, so either is acceptable.

**QUESTION:** What is the Hz on the electrical 50 or 60hz?

**ANSWER:** 60 Hz

## Publications

- October 2, 2025: Combined synopsis and solicitation, due October 7, 2025 at 2:00 PM EDT. Notice 2a5d13933d044e938b03f753d133079a. https://sam.gov/workspace/contract/opp/2a5d13933d044e938b03f753d133079a/view
- October 2, 2025: Combined synopsis and solicitation, due October 7, 2025 at 2:00 PM EDT. Notice 8a0f4a459d874942930ae74941fb6621. https://sam.gov/workspace/contract/opp/8a0f4a459d874942930ae74941fb6621/view
- October 6, 2025: Combined synopsis and solicitation, due October 7, 2025 at 2:00 PM EDT. Notice 6009589cedfe46ada4d163f9303dfb25. https://sam.gov/workspace/contract/opp/6009589cedfe46ada4d163f9303dfb25/view

## Points of contact

- Maria Diaz-Sotomayor, maria.d.diaz-sotomayor.civ@us.navy.mil, 4018322028

---
Source: SAM.gov Contract Opportunities bulk extract. Confirm deadlines on SAM.gov before responding. Cite https://abierto.us/opportunities/n6660426q0022.