{"canonical":"https://abierto.us/opportunities/n4008524r2828","key":"N4008524R2828","url":"https://abierto.us/opportunities/n4008524r2828","title":"REPLACE CRAC UNITS IN SERVER ROOM, BLDG 250, DAM NECK ANNEX","solicitation_number":"N4008524R2828","notice_type":"o","open":false,"response_deadline":"2024-09-30T18:00:00Z","first_posted":"2024-08-29","last_posted":"2024-09-25","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE NAVY","office":"NAVFACSYSCOM MID-ATLANTIC","naics":"236220","psc":"Z2JZ","set_aside":null,"place_state":"VA","place_county":"51810","place_county_name":"City of Virginia Beach","place_city":"5182000","place_city_name":"Virginia Beach","winner":null,"award_amount":null,"publications":[{"notice_id":"4235fcbc4db140bcb5cbeb2185824fd5","title":"REPLACE CRAC UNITS IN SERVER ROOM, BLDG 250, DAM NECK ANNEX","solicitation_number":"N4008524R2828","notice_type":"o","base_type":"o","posted":"2024-08-29","posted_at":null,"due_at":"2024-09-30T18:00:00Z","due_date":"2024-09-30","cancelled":null,"archived":null,"archive_date":"2024-10-15","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/4235fcbc4db140bcb5cbeb2185824fd5/view","enriched":false,"history":[]},{"notice_id":"c131df90833f471da09a91cea02896e9","title":"REPLACE CRAC UNITS IN SERVER ROOM, BLDG 250, DAM NECK ANNEX","solicitation_number":"N4008524R2828","notice_type":"o","base_type":"o","posted":"2024-09-25","posted_at":null,"due_at":"2024-09-30T18:00:00Z","due_date":"2024-09-30","cancelled":null,"archived":null,"archive_date":"2024-10-15","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/c131df90833f471da09a91cea02896e9/view","enriched":false,"history":[]}],"latest_notice_id":"c131df90833f471da09a91cea02896e9","first_type":"o","notices":[{"dates":{"posted":"2024-08-29","response_deadline":{"raw":"2024-09-30T14:00:00-04:00","utc":"2024-09-30T18:00:00Z","date":"2024-09-30","time":"14:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/4235fcbc4db140bcb5cbeb2185824fd5/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"REPLACE CRAC UNITS IN SERVER ROOM, BLDG 250, DAM NECK ANNEX","agency":{"office":{"code":"N40085","name":"NAVFACSYSCOM MID-ATLANTIC"},"subtier":{"code":"1700","name":"DEPT OF THE NAVY"},"department":{"code":"017","name":"DEPT OF DEFENSE"},"office_address":{"zip":"23511-0395","city":"NORFOLK","state":"VA","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-10-15","archive_type":"auto15"},"contacts":[{"name":"Jessica Grosso","role":"primary","email":"jessica.m.grosso.civ@us.navy.mil","phone":"7574333623"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"4235fcbc4db140bcb5cbeb2185824fd5","provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"3022b70ddba9e1aee9e3974101729eb10221b4af94ff09e0e4a203a79b9a6607","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"This project will provide for removal of two DX, nominal 26 ton air cooled split type Computer Room Air Conditioning (CRAC) systems. Each system consists of a Stulz model No. VFS–312–DAR-U indoor unit and SCS-312 remote air cooled condensing unit. The condensing units are located on the roof of B-250, which is a two story building. The associated refrigerant piping and ductwork shall also be removed. Two new non-ducted, air cooled, split type CRAC systems configured for upflow air discharge, each sized for the indicated IT equipment heat dissipation and room envelope loads shall be provided. The intent is to provide a lead/lag arrangement and locate the new indoor units in the same approximate location as the existing units. All building systems such as Architectural, Electrical, Fire Protection will be coordinated and modified to accommodate the mechanical renovation workThis project will provide for removal of two DX, nominal 26 ton air cooled split type Computer Room Air Conditioning (CRAC) systems. Each system consists of a Stulz model No. VFS–312–DAR-U indoor unit and SCS-312 remote air cooled condensing unit. The condensing units are located on the roof of B-250, which is a two story building. The associated refrigerant piping and ductwork shall also be removed. Two new non-ducted, air cooled, split type CRAC systems configured for upflow air discharge, each sized for the indicated IT equipment heat dissipation and room envelope loads shall be provided. The intent is to provide a lead/lag arrangement and locate the new indoor units in the same approximate location as the existing units. All building systems such as Architectural, Electrical, Fire Protection will be coordinated and modified to accommodate the mechanical renovation work. ONLY CONTRACTORS ON THIS MACC GROUP CAN SUBMIT A PROPOSAL.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"N4008524R2828","place_of_performance":{"zip":"23460","city":{"name":"Virginia Beach"},"state":{"code":"VA"},"country":{"code":"USA"}},"product_service_code":"Z2JZ"},{"dates":{"posted":"2024-09-25","response_deadline":{"raw":"2024-09-30T14:00:00-04:00","utc":"2024-09-30T18:00:00Z","date":"2024-09-30","time":"14:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/c131df90833f471da09a91cea02896e9/view"},"naics":{"codes":["236220"],"primary":"236220"},"title":"REPLACE CRAC UNITS IN SERVER ROOM, BLDG 250, DAM NECK ANNEX","agency":{"office":{"code":"N40085","name":"NAVFACSYSCOM MID-ATLANTIC"},"subtier":{"code":"1700","name":"DEPT OF THE NAVY"},"department":{"code":"017","name":"DEPT OF DEFENSE"},"office_address":{"zip":"23511-0395","city":"NORFOLK","state":"VA","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-10-15","archive_type":"auto15"},"contacts":[{"name":"Jessica Grosso","role":"primary","email":"jessica.m.grosso.civ@us.navy.mil","phone":"7574333623"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"c131df90833f471da09a91cea02896e9","provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"4044dc11e1753e1b669a8722ae7fcb3d9f8e8e206957066e8186a121abc28a3b","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"This project will provide for removal of two DX, nominal 26 ton air cooled split type Computer Room Air Conditioning (CRAC) systems. Each system consists of a Stulz model No. VFS–312–DAR-U indoor unit and SCS-312 remote air cooled condensing unit. The condensing units are located on the roof of B-250, which is a two story building. The associated refrigerant piping and ductwork shall also be removed. Two new non-ducted, air cooled, split type CRAC systems configured for upflow air discharge, each sized for the indicated IT equipment heat dissipation and room envelope loads shall be provided. The intent is to provide a lead/lag arrangement and locate the new indoor units in the same approximate location as the existing units. All building systems such as Architectural, Electrical, Fire Protection will be coordinated and modified to accommodate the mechanical renovation workThis project will provide for removal of two DX, nominal 26 ton air cooled split type Computer Room Air Conditioning (CRAC) systems. Each system consists of a Stulz model No. VFS–312–DAR-U indoor unit and SCS-312 remote air cooled condensing unit. The condensing units are located on the roof of B-250, which is a two story building. The associated refrigerant piping and ductwork shall also be removed. Two new non-ducted, air cooled, split type CRAC systems configured for upflow air discharge, each sized for the indicated IT equipment heat dissipation and room envelope loads shall be provided. The intent is to provide a lead/lag arrangement and locate the new indoor units in the same approximate location as the existing units. All building systems such as Architectural, Electrical, Fire Protection will be coordinated and modified to accommodate the mechanical renovation work. ONLY CONTRACTORS ON THIS MACC GROUP CAN SUBMIT A PROPOSAL.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"N4008524R2828","place_of_performance":{"zip":"23460","city":{"name":"Virginia Beach"},"state":{"code":"VA"},"country":{"code":"USA"}},"product_service_code":"Z2JZ"}],"due_at":"2024-09-30T18:00:00Z","due_date":"2024-09-30","closes_at":"2024-09-30T18:00:00Z","awardable":true,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N40085","office_name":"NAVFACSYSCOM MID-ATLANTIC","state":"VA","county":"51810","county_name":"City of Virginia Beach","city":"5182000","city_name":"Virginia Beach","country":"USA","winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z","principal_notice_id":"c131df90833f471da09a91cea02896e9","description":{"text":"This project will provide for removal of two DX, nominal 26 ton air cooled split type Computer Room Air Conditioning (CRAC) systems. Each system consists of a Stulz model No. VFS–312–DAR-U indoor unit and SCS-312 remote air cooled condensing unit. The condensing units are located on the roof of B-250, which is a two story building. The associated refrigerant piping and ductwork shall also be removed. Two new non-ducted, air cooled, split type CRAC systems configured for upflow air discharge, each sized for the indicated IT equipment heat dissipation and room envelope loads shall be provided. The intent is to provide a lead/lag arrangement and locate the new indoor units in the same approximate location as the existing units. All building systems such as Architectural, Electrical, Fire Protection will be coordinated and modified to accommodate the mechanical renovation workThis project will provide for removal of two DX, nominal 26 ton air cooled split type Computer Room Air Conditioning (CRAC) systems. Each system consists of a Stulz model No. VFS–312–DAR-U indoor unit and SCS-312 remote air cooled condensing unit. The condensing units are located on the roof of B-250, which is a two story building. The associated refrigerant piping and ductwork shall also be removed. Two new non-ducted, air cooled, split type CRAC systems configured for upflow air discharge, each sized for the indicated IT equipment heat dissipation and room envelope loads shall be provided. The intent is to provide a lead/lag arrangement and locate the new indoor units in the same approximate location as the existing units. All building systems such as Architectural, Electrical, Fire Protection will be coordinated and modified to accommodate the mechanical renovation work. ONLY CONTRACTORS ON THIS MACC GROUP CAN SUBMIT A PROPOSAL.","html":null,"origin":"extract"},"contacts":[{"name":"Jessica Grosso","role":"primary","email":"jessica.m.grosso.civ@us.navy.mil","phone":"7574333623"}],"place_of_performance":{"zip":"23460","city":{"name":"Virginia Beach"},"state":{"code":"VA"},"country":{"code":"USA"}},"office_address":{"zip":"23511-0395","city":"NORFOLK","state":"VA","country":"USA"},"naics_codes":["236220"],"award":null,"attachments":[],"awards":[],"related":[{"key":"N4008526R0245","latest_notice_id":"f272e42d73514de49f8ade7314006666","title":"Crane Lease/ Rental Services","solicitation_number":"N4008526R0245","notice_type":"o","first_type":"o","first_posted":"2026-08-08","last_posted":"2026-09-10","notices":7,"due_at":"2026-09-18T16:00:00Z","due_date":"2026-09-18","closes_at":"2026-09-18T16:00:00Z","awardable":true,"open":true,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N40085","office_name":"NAVFACSYSCOM MID-ATLANTIC","naics":"238990","psc":"W099","set_aside":null,"state":"CT","county":null,"county_name":null,"city":"0934180","city_name":"Groton","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"N400857606105","latest_notice_id":"45ec61c7ae59438f9e9b87d1edee9a6d","title":"Paint All Exterior and Common Area Doors, Buildings 4166, 4167, 4168, 4169 & 3673","solicitation_number":"N400857606105","notice_type":"o","first_type":"o","first_posted":"2026-09-03","last_posted":"2026-09-03","notices":1,"due_at":"2026-09-18T16:00:00Z","due_date":"2026-09-18","closes_at":"2026-09-18T16:00:00Z","awardable":true,"open":true,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N40085","office_name":"NAVFACSYSCOM MID-ATLANTIC","naics":"236220","psc":"Z2JZ","set_aside":null,"state":"NC","county":"37049","county_name":"Craven County","city":null,"city_name":null,"country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"N4008526R0224","latest_notice_id":"d81e56db40214ae99ef31b365ea7f6c3","title":"REPLACE TRANSFORMERS AND ELECTRICAL PANELS, NAS OCEANA-285, VIRGINIA BEACH, VA","solicitation_number":"N4008526R0224","notice_type":"o","first_type":"o","first_posted":"2026-08-21","last_posted":"2026-09-15","notices":8,"due_at":"2026-09-18T18:00:00Z","due_date":"2026-09-18","closes_at":"2026-09-18T18:00:00Z","awardable":true,"open":true,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N40085","office_name":"NAVFACSYSCOM MID-ATLANTIC","naics":"236220","psc":"Z2JZ","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"N4008526R0254","latest_notice_id":"c74d8f6a58804ce29cf7cbf009fbe14a","title":"NNSY DD4 DUCT INSULATION REPLACEMENT","solicitation_number":"N4008526R0254","notice_type":"o","first_type":"o","first_posted":"2026-08-26","last_posted":"2026-08-26","notices":1,"due_at":"2026-09-21T07:00:00Z","due_date":"2026-09-21","closes_at":"2026-09-21T07:00:00Z","awardable":true,"open":true,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N40085","office_name":"NAVFACSYSCOM MID-ATLANTIC","naics":"238220","psc":"Z2PZ","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"N400857190530","latest_notice_id":"db2eb126c0174fb9b751f9d90909bdf3","title":"N400857190530 Upgrade Life Health Safety Systems in Hangar 250","solicitation_number":"N400857190530","notice_type":"o","first_type":"o","first_posted":"2026-09-03","last_posted":"2026-09-04","notices":2,"due_at":"2026-09-21T19:00:00Z","due_date":"2026-09-21","closes_at":"2026-09-21T19:00:00Z","awardable":true,"open":true,"dept_key":"d-017","dept_name":"DEPT OF DEFENSE","sub_key":"s-1700","sub_name":"DEPT OF THE NAVY","office_key":"o-N40085","office_name":"NAVFACSYSCOM MID-ATLANTIC","naics":"236220","psc":"Z2JZ","set_aside":"SBA","state":"NC","county":null,"county_name":null,"city":null,"city_name":null,"country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"}]}