# HASKELL IHS - VESTIBULE DOORS, SIDELIGHTS, AND TRANSOMS REPLACEMENT

Canonical: https://abierto.us/opportunities/ihs1512570

- Solicitation number: IHS1512570
- Notice type: Solicitation (first published as presolicitation)
- Status: Closed. Deadline was July 7, 2025 at 6:00 PM EDT
- Department: Department of Health and Human Services
- Agency: Indian Health Service
- Contracting office: Indian Health Service (75H711)
- NAICS: 236220 Commercial and Institutional Building Construction
- Product or service code: Z2DA Repair Or Alteration Of Hospitals And Infirmaries
- Set-aside: Indian small business economic enterprise
- Place of performance: Lawrence, Kansas
- County: Douglas County (FIPS 20045). https://abierto.us/counties/douglas-county-ks-20045
- City: Lawrence. https://abierto.us/cities/lawrence-ks-2038900
- First posted: May 19, 2025
- Last posted: June 5, 2025
- SAM.gov: https://sam.gov/workspace/contract/opp/bed716b864a2457aa9335cdf4d7320ce/view

## Description

1. PURPOSE OF THE PROJECT The Haskell Indian Health Center (HIHC), Indian Health Services (IHS) has a requirement for the replacement of (4) existing exterior entryway doors, (4) interior entryway doors, and the sidelights and transoms for all (4) vestibules.

2. DETAILED DESCRIPTION OF THE TECHNICAL REQUIREMENTS • The interior and exterior doors shall be 42” wide to accommodate gurneys used by EMS and wide wheelchairs. • All exterior doors shall have a full window/daylight panel measuring approximately 34”x 69” and be UL 752 Level 5 bullet resistant glazing or equivalent. • All exterior glazing (door, transom, sidelights, exterior vestibule) shall be UL 752 Level 5 bullet resistant glazing or equivalent, except where noted in the scope of work.

Interior glazing (door, transom, sidelights) shall be ¼” tempered glass. • The northwest corner of the building has an existing metal and glass vestibule protruding from the building measuring approximately 36” out from the building and 64” wide. The (2) panes of glass on the exterior vestibule measure approximately 30”x 90”. These panes of glass shall be replaced with UL Level 5 bullet resistant glazing or equivalent. Within this vestibule there shall be a left hand reverse exterior door measuring 42”x 84”.

The transom window shall be 4”x 42” and shall be 1/4” tempered glass.

The interior door, leading from the vestibule to the Pediatric/Behavior Health (north) hallway, shall be a left hand reverse door measuring 42”x 84” with (2) sidelights measuring approximately 8” x 100” and a transom measuring approximately 16” x 42”. • The far west entryway leading to the Medical Staff hallway shall have a left hand reverse exterior door measuring 42”x 84” with (2) sidelights measuring approximately 14”x 100”and a transom measuring approximately 16”x 42”.

The interior door shall be a left hand reverse door measuring 42”x 84” with (2) sidelights measuring approximately 15”x 100” and a transom measuring approximately 16”x 42”. • The south/southwest entryway in the breezeway between the Main Building and Wellness Center shall have a right hand reverse exterior door measuring 42”x 84” with (1) sidelight measuring approximately 13”x 101” and a transom measuring approximately 17”x 42”.

The interior door shall be a right hand reverse door measuring 42”x 84” with (2) sidelights measuring approximately 5”x 100” and a transom measuring approximately 16”x 42”. • The south entryway near the kitchen shall have a left hand reverse exterior door measuring 42”x 84” with (2) sidelights measuring approximately 15”x 100” and a transom measuring approximately 17”x 42”.

The interior door shall be a left hand reverse door measuring 42”x 84” with (2) sidelights measuring approximately 15”x 100” and a transom measuring approximately 16”x 42”. • Contractor shall coordinate with the facility’s existing Secure Access Control provider (Cam-Dex Security Corp.) to remove and replace the wires, card readers, and electronically operated door strikes back to original locations or as close as possible for all replaced doors.

Card readers and strikes shall be in good working order before starting on the next exterior door for security purposes and to justify egress. • Door and window frames shall be black anodized aluminum and match the fit and finish of the current frames. • All doors, interior and exterior, shall be equipped with a commercial grade LCN door closer, panic bar, heavy-duty continuous hinge with threshold, and lock keyed to the facility master key. • All exterior doors, sidelights and transoms shall be tinted with a mirror tint that is reflective when viewed from the exterior.

In addition, the same tint shall be applied to the front (east), exterior, automatic sliding door entrance. Tinting shall be minimum of 35% shade. • All (4) exterior doors shall be equipped with awnings that span the width of the exterior frame to cover persons entering and exiting the building. The awnings shall be black anodized aluminum (or equivalent metal) to match the fit and finish of the exterior frames. The awnings shall not extend more than 36” away from the building. All awnings shall be equipped with gutters and downspouts to divert water away from the building.

## Publications

- May 19, 2025: Presolicitation, due June 3, 2025 at 3:00 PM EDT. Notice 5adff37bb098484b9538c795fd5fa7c5. https://sam.gov/workspace/contract/opp/5adff37bb098484b9538c795fd5fa7c5/view
- June 5, 2025: Solicitation, due July 7, 2025 at 6:00 PM EDT. Notice bed716b864a2457aa9335cdf4d7320ce. https://sam.gov/workspace/contract/opp/bed716b864a2457aa9335cdf4d7320ce/view

## Points of contact

- Mary Ann Yocham, MaryAnn.Yocham@ihs.gov, 4059516043

---
Source: SAM.gov Contract Opportunities bulk extract. Confirm deadlines on SAM.gov before responding. Cite https://abierto.us/opportunities/ihs1512570.