{"canonical":"https://abierto.us/opportunities/ht942524r0076","key":"HT942524R0076","url":"https://abierto.us/opportunities/ht942524r0076","title":"INTRAVENOUS SYRINGE PUMP (IVSP)","solicitation_number":"HT942524R0076","notice_type":"o","open":false,"response_deadline":"2024-06-28T15:00:00Z","first_posted":"2024-05-29","last_posted":"2024-06-13","department":"DEPT OF DEFENSE","subagency":"DEFENSE HEALTH AGENCY (DHA)","office":"ARMY MED RES ACQ ACTIVITY","naics":"339112","psc":"AN45","set_aside":null,"place_state":"TX","place_county":"48157","place_county_name":"Fort Bend County","place_city":"4869908","place_city_name":"Stafford","winner":"GOLDEN MAX LLC","award_amount":null,"publications":[{"notice_id":"0bd5cdb2b6764423b970670ff20b5f3c","title":"INTRAVENOUS SYRINGE PUMP (IVSP)","solicitation_number":"HT942524R0076","notice_type":"o","base_type":"o","posted":"2024-05-29","posted_at":null,"due_at":"2024-06-14T15:00:00Z","due_date":"2024-06-14","cancelled":null,"archived":null,"archive_date":"2025-05-29","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/0bd5cdb2b6764423b970670ff20b5f3c/view","enriched":false,"history":[]},{"notice_id":"702703261ec445ce939e21cff34150e5","title":"INTRAVENOUS SYRINGE PUMP (IVSP)","solicitation_number":"HT942524R0076","notice_type":"o","base_type":"o","posted":"2024-05-31","posted_at":null,"due_at":"2024-06-14T15:00:00Z","due_date":"2024-06-14","cancelled":null,"archived":null,"archive_date":"2025-05-31","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/702703261ec445ce939e21cff34150e5/view","enriched":false,"history":[]},{"notice_id":"d424c42a048a49a78c61dce115a4670c","title":"INTRAVENOUS SYRINGE PUMP (IVSP)","solicitation_number":"HT942524R0076","notice_type":"o","base_type":"o","posted":"2024-06-13","posted_at":null,"due_at":"2024-06-28T15:00:00Z","due_date":"2024-06-28","cancelled":null,"archived":null,"archive_date":"2025-06-13","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/d424c42a048a49a78c61dce115a4670c/view","enriched":false,"history":[]}],"latest_notice_id":"d424c42a048a49a78c61dce115a4670c","first_type":"o","notices":[{"dates":{"posted":"2024-05-29","response_deadline":{"raw":"2024-06-14T11:00:00-04:00","utc":"2024-06-14T15:00:00Z","date":"2024-06-14","time":"11:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/0bd5cdb2b6764423b970670ff20b5f3c/view"},"naics":{"codes":["339112"],"primary":"339112"},"title":"INTRAVENOUS SYRINGE PUMP (IVSP)","agency":{"office":{"code":"HT9425","name":"ARMY MED RES ACQ ACTIVITY"},"subtier":{"code":"97DH","name":"DEFENSE HEALTH AGENCY (DHA)"},"department":{"code":"097","name":"DEPT OF DEFENSE"},"office_address":{"zip":"21702","city":"FORT DETRICK","state":"MD","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2025-05-29","archive_type":"auto_custom"},"contacts":[{"name":"Peter Mitchell","role":"primary","email":"PETER.D.MITCHELL8.CIV@HEALTH.MIL","phone":"8139198214"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"0bd5cdb2b6764423b970670ff20b5f3c","provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"7c49f221e9761c5d0b15d4f5dd32bb593eb0a963ee8e3db336edf56718feae93","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"USAMMDA has a requirement to procure an Intravenous Syringe Pump (IVSP). The IVSP is a medical device used to administer a highly accurate and consistent volume for small amounts of intravenous (IV) fluids such as antibiotics, regional anesthetics, antiarrhythmic medications, and chemotherapeutic agents in hospitals (role of care 3), veterinary medicine, and medical units able to conduct advanced resuscitation procedures and lifesaving surgeries (role of care 2). IVSPs should be able to provide a flow of 0.1 to at least 99.9 mL/hr in 0.1 mL increments and maintain an accurate flow rate to within 5% of flow settings. Pumps should accommodate syringe sizes from 3 to 60 mL. Pumps that accept syringes smaller than 3 mL may be advantageous in some settings. The pump should be designed to revert to a KVO (keep vein open) rate between 1 and 5 mL/hr (but not greater than the programmed flow rate) once the programmed volume is delivered. Facilities should also look for pumps that have pump-based priming.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"HT942524R0076","product_service_code":"AN43"},{"dates":{"posted":"2024-05-31","response_deadline":{"raw":"2024-06-14T11:00:00-04:00","utc":"2024-06-14T15:00:00Z","date":"2024-06-14","time":"11:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/702703261ec445ce939e21cff34150e5/view"},"naics":{"codes":["339112"],"primary":"339112"},"title":"INTRAVENOUS SYRINGE PUMP (IVSP)","agency":{"office":{"code":"HT9425","name":"ARMY MED RES ACQ ACTIVITY"},"subtier":{"code":"97DH","name":"DEFENSE HEALTH AGENCY (DHA)"},"department":{"code":"097","name":"DEPT OF DEFENSE"},"office_address":{"zip":"21702","city":"FORT DETRICK","state":"MD","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2025-05-31","archive_type":"auto_custom"},"contacts":[{"name":"Peter Mitchell","role":"primary","email":"PETER.D.MITCHELL8.CIV@HEALTH.MIL","phone":"8139198214"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"702703261ec445ce939e21cff34150e5","provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"480479b58d2af2ac4311682a165f37830eefde76d033b0f6cc0d39b6332495a4","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"USAMMDA has a requirement to procure an Intravenous Syringe Pump (IVSP). The IVSP is a medical device used to administer a highly accurate and consistent volume for small amounts of intravenous (IV) fluids such as antibiotics, regional anesthetics, antiarrhythmic medications, and chemotherapeutic agents in hospitals (role of care 3), veterinary medicine, and medical units able to conduct advanced resuscitation procedures and lifesaving surgeries (role of care 2). IVSPs should be able to provide a flow of 0.1 to at least 99.9 mL/hr in 0.1 mL increments and maintain an accurate flow rate to within 5% of flow settings. Pumps should accommodate syringe sizes from 3 to 60 mL. Pumps that accept syringes smaller than 3 mL may be advantageous in some settings. The pump should be designed to revert to a KVO (keep vein open) rate between 1 and 5 mL/hr (but not greater than the programmed flow rate) once the programmed volume is delivered. Facilities should also look for pumps that have pump-based priming.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"HT942524R0076","product_service_code":"AN45"},{"dates":{"posted":"2024-06-13","response_deadline":{"raw":"2024-06-28T11:00:00-04:00","utc":"2024-06-28T15:00:00Z","date":"2024-06-28","time":"11:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/d424c42a048a49a78c61dce115a4670c/view"},"naics":{"codes":["339112"],"primary":"339112"},"title":"INTRAVENOUS SYRINGE PUMP (IVSP)","agency":{"office":{"code":"HT9425","name":"ARMY MED RES ACQ ACTIVITY"},"subtier":{"code":"97DH","name":"DEFENSE HEALTH AGENCY (DHA)"},"department":{"code":"097","name":"DEPT OF DEFENSE"},"office_address":{"zip":"21702","city":"FORT DETRICK","state":"MD","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2025-06-13","archive_type":"auto_custom"},"contacts":[{"name":"Peter Mitchell","role":"primary","email":"PETER.D.MITCHELL8.CIV@HEALTH.MIL","phone":"8139198214"},{"name":"Shannon Lertora","role":"secondary","email":"shannon.p.lertora.civ@health.mil","phone":"3016192555"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"d424c42a048a49a78c61dce115a4670c","provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"5df9999359fa45946769eb875d9935bbdd03c73d351cd98e086a01b687be8e7d","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"USAMMDA has a requirement to procure an Intravenous Syringe Pump (IVSP). The IVSP is a medical device used to administer a highly accurate and consistent volume for small amounts of intravenous (IV) fluids such as antibiotics, regional anesthetics, antiarrhythmic medications, and chemotherapeutic agents in hospitals (role of care 3), veterinary medicine, and medical units able to conduct advanced resuscitation procedures and lifesaving surgeries (role of care 2). IVSPs should be able to provide a flow of 0.1 to at least 99.9 mL/hr in 0.1 mL increments and maintain an accurate flow rate to within 5% of flow settings. Pumps should accommodate syringe sizes from 3 to 60 mL. Pumps that accept syringes smaller than 3 mL may be advantageous in some settings. The pump should be designed to revert to a KVO (keep vein open) rate between 1 and 5 mL/hr (but not greater than the programmed flow rate) once the programmed volume is delivered. Facilities should also look for pumps that have pump-based priming.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"HT942524R0076","product_service_code":"AN45"}],"due_at":"2024-06-28T15:00:00Z","due_date":"2024-06-28","closes_at":"2024-06-28T15:00:00Z","awardable":false,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97DH","sub_name":"DEFENSE HEALTH AGENCY (DHA)","office_key":"o-HT9425","office_name":"ARMY MED RES ACQ ACTIVITY","state":"TX","county":"48157","county_name":"Fort Bend County","city":"4869908","city_name":"Stafford","country":null,"winner_key":"ENFMGE9JQE55","amount":null,"linked_awards":6,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z","principal_notice_id":"d424c42a048a49a78c61dce115a4670c","description":{"text":"USAMMDA has a requirement to procure an Intravenous Syringe Pump (IVSP). The IVSP is a medical device used to administer a highly accurate and consistent volume for small amounts of intravenous (IV) fluids such as antibiotics, regional anesthetics, antiarrhythmic medications, and chemotherapeutic agents in hospitals (role of care 3), veterinary medicine, and medical units able to conduct advanced resuscitation procedures and lifesaving surgeries (role of care 2). IVSPs should be able to provide a flow of 0.1 to at least 99.9 mL/hr in 0.1 mL increments and maintain an accurate flow rate to within 5% of flow settings. Pumps should accommodate syringe sizes from 3 to 60 mL. Pumps that accept syringes smaller than 3 mL may be advantageous in some settings. The pump should be designed to revert to a KVO (keep vein open) rate between 1 and 5 mL/hr (but not greater than the programmed flow rate) once the programmed volume is delivered. Facilities should also look for pumps that have pump-based priming.","html":null,"origin":"extract"},"contacts":[{"name":"Peter Mitchell","role":"primary","email":"PETER.D.MITCHELL8.CIV@HEALTH.MIL","phone":"8139198214"},{"name":"Shannon Lertora","role":"secondary","email":"shannon.p.lertora.civ@health.mil","phone":"3016192555"}],"place_of_performance":null,"office_address":{"zip":"21702","city":"FORT DETRICK","state":"MD","country":"USA"},"naics_codes":["339112"],"award":null,"attachments":[],"awards":[{"award_key":"CONT_AWD_HT942524P0108_9700_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_HT942524P0108_9700_-NONE-_-NONE-/","piid":"HT942524P0108","parent_piid":null,"award_type":"PURCHASE ORDER","vendor_key":"ENFMGE9JQE55","recipient_name":"GOLDEN MAX LLC","recipient_uei":"ENFMGE9JQE55","recipient_cage":"85F06","recipient_city":"STAFFORD","recipient_state":"TX","sub_name":"Defense Health Agency","office_name":"ARMY MED RES ACQ ACTIVITY","office_key":"o-HT9425","first_action_date":"2024-09-05","last_action_date":"2024-09-05","actions":1,"obligated":"19200.00","current_total_value":"19200.00","potential_total_value":"19200.00","naics":"339112","psc":"AN45","extent_competed":"COMPETED UNDER SAP","set_aside":"NO SET ASIDE USED.","offers_received":3,"description":"INTRAVENOUS SYRINGE PUMP (IVSP) TEST ARTICLE","method":"solicitation","confidence":"high","evidence":["solicitation number HT942524R0076 equals the FPDS solicitation identifier","same awarding office HT9425"],"opportunity_key":null,"opportunity_title":null},{"award_key":"CONT_AWD_HT942524P0110_9700_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_HT942524P0110_9700_-NONE-_-NONE-/","piid":"HT942524P0110","parent_piid":null,"award_type":"PURCHASE ORDER","vendor_key":"VZ9ECP5M2VM7","recipient_name":"640 ACRES, LLC","recipient_uei":"VZ9ECP5M2VM7","recipient_cage":"7YAX4","recipient_city":"GIG HARBOR","recipient_state":"WA","sub_name":"Defense Health Agency","office_name":"ARMY MED RES ACQ ACTIVITY","office_key":"o-HT9425","first_action_date":"2024-09-05","last_action_date":"2024-09-05","actions":1,"obligated":"23810.22","current_total_value":"23810.22","potential_total_value":"23810.22","naics":"339112","psc":"AN45","extent_competed":"COMPETED UNDER SAP","set_aside":"NO SET ASIDE USED.","offers_received":3,"description":"INTRAVENOUS SYRINGE PUMP (IVSP) TEST ARTICLE","method":"solicitation","confidence":"high","evidence":["solicitation number HT942524R0076 equals the FPDS solicitation identifier","same awarding office HT9425"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"HT942526RE004","latest_notice_id":"d2b355b9ba3f4796b4639c7664f17bfa","title":"Women, Infant, Children Overseas Contract","solicitation_number":"HT9425-26-R-E004","notice_type":"o","first_type":"o","first_posted":"2026-08-18","last_posted":"2026-08-27","notices":3,"due_at":"2026-09-18T14:00:00Z","due_date":"2026-09-18","closes_at":"2026-09-18T14:00:00Z","awardable":true,"open":true,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97DH","sub_name":"DEFENSE HEALTH AGENCY (DHA)","office_key":"o-HT9425","office_name":"ARMY MED RES ACQ ACTIVITY","naics":"541611","psc":"R408","set_aside":"8A","state":"VA","county":"51610","county_name":"City of Falls Church","city":"5127200","city_name":"Falls Church","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"HT942626QE031","latest_notice_id":"2c4d09774d794c22961a3aaec353e88e","title":"Blanket Purchase Agreement for Medical Gases and Dry Ice","solicitation_number":"HT942626QE031","notice_type":"k","first_type":"k","first_posted":"2026-06-12","last_posted":"2026-08-26","notices":6,"due_at":"2026-10-01T15:00:00Z","due_date":"2026-10-01","closes_at":"2026-10-01T15:00:00Z","awardable":true,"open":true,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97DH","sub_name":"DEFENSE HEALTH AGENCY (DHA)","office_key":"o-HT9425","office_name":"ARMY MED RES ACQ ACTIVITY","naics":"325120","psc":"6830","set_aside":"SBA","state":"MD","county":"24031","county_name":"Montgomery County","city":"2472450","city_name":"Silver Spring","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"HT942726RE015","latest_notice_id":"3f41946e77904b6c9444a053683c4bfa","title":"COMBINED SYNOPSIS/SOLICITATION for Regulated Medical Waste services","solicitation_number":"HT942726RE015","notice_type":"k","first_type":"k","first_posted":"2026-08-27","last_posted":"2026-09-14","notices":3,"due_at":"2026-10-05T18:00:00Z","due_date":"2026-10-05","closes_at":"2026-10-05T18:00:00Z","awardable":true,"open":true,"dept_key":"d-097","dept_name":"DEPT OF DEFENSE","sub_key":"s-97DH","sub_name":"DEFENSE HEALTH AGENCY (DHA)","office_key":"o-HT9425","office_name":"ARMY MED RES ACQ ACTIVITY","naics":"562211","psc":"S222","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"}]}