{"canonical":"https://abierto.us/opportunities/fa940124q0035","key":"FA940124Q0035","url":"https://abierto.us/opportunities/fa940124q0035","title":"Battery Install and Replacement","solicitation_number":"FA940124Q0035","notice_type":"k","open":false,"response_deadline":"2024-09-19T20:00:00Z","first_posted":"2024-05-17","last_posted":"2024-09-17","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE AIR FORCE","office":"FA9401 377 MSG PK","naics":"335910","psc":"6140","set_aside":"SBA","place_state":"NM","place_county":"35001","place_county_name":"Bernalillo County","place_city":"3536300","place_city_name":"Kirtland AFB","winner":null,"award_amount":null,"publications":[{"notice_id":"25c79a366e3c4f0f85e78f9cd35a46b2","title":"58 AMXS Deicer Repair Parts","solicitation_number":"FA9401-24-Q-0035","notice_type":"r","base_type":"r","posted":"2024-05-17","posted_at":null,"due_at":"2024-05-28T18:00:00Z","due_date":"2024-05-28","cancelled":null,"archived":null,"archive_date":"2024-05-29","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/25c79a366e3c4f0f85e78f9cd35a46b2/view","enriched":false,"history":[]},{"notice_id":"40d3cf95c85f43c59f16984207523ba8","title":"Battery Install and Replacement","solicitation_number":"FA940124Q0035","notice_type":"k","base_type":"k","posted":"2024-09-12","posted_at":null,"due_at":"2024-09-19T20:00:00Z","due_date":"2024-09-19","cancelled":null,"archived":null,"archive_date":"2024-10-04","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/40d3cf95c85f43c59f16984207523ba8/view","enriched":false,"history":[]},{"notice_id":"47f6fc3eb55c42cc88ce24a547a91650","title":"Battery Install and Replacement","solicitation_number":"FA940124Q0035","notice_type":"k","base_type":"k","posted":"2024-09-17","posted_at":null,"due_at":"2024-09-19T20:00:00Z","due_date":"2024-09-19","cancelled":null,"archived":null,"archive_date":"2024-10-04","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/47f6fc3eb55c42cc88ce24a547a91650/view","enriched":false,"history":[]}],"latest_notice_id":"47f6fc3eb55c42cc88ce24a547a91650","first_type":"r","notices":[{"dates":{"posted":"2024-05-17","response_deadline":{"raw":"2024-05-28T12:00:00-06:00","utc":"2024-05-28T18:00:00Z","date":"2024-05-28","time":"12:00:00","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/25c79a366e3c4f0f85e78f9cd35a46b2/view"},"naics":{"codes":["336370"],"primary":"336370"},"title":"58 AMXS Deicer Repair Parts","agency":{"office":{"code":"FA9401","name":"FA9401 377 MSG PK"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"87117-0001","city":"KIRTLAND AFB","state":"NM","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-05-29","archive_type":"auto_custom"},"contacts":[{"name":"Austin Swain","role":"primary","email":"austin.swain@us.af.mil","phone":"5058469742"},{"name":"Kelly Scott","role":"secondary","email":"kelly.scott.8@us.af.mil"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"25c79a366e3c4f0f85e78f9cd35a46b2","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"e32f5de5ac08ec4b4e7e1c8484c406d5f31cf9bd461c06a272e8e1a6286b9b25","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"Item: 02 each hose, 01 heat exchanger Brief description: Parts to fix Global Ground deicer truck. The contractor shall provide the following items: 499-60002 Hose Assembly, 1 ¼”X108”-TII Supply/Boom 1 499-70021 Hose Assembly, 1 ½”X 385”-Deicing **Apache** 1 501-05028, Heat Exchanger(SSC-1248-211679) 1","origin":"extract"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"FA9401-24-Q-0035","place_of_performance":{"zip":"87117","city":{"name":"Kirtland AFB"},"state":{"code":"NM"},"country":{"code":"USA"}},"product_service_code":"2320"},{"dates":{"posted":"2024-09-12","response_deadline":{"raw":"2024-09-19T14:00:00-06:00","utc":"2024-09-19T20:00:00Z","date":"2024-09-19","time":"14:00:00","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/40d3cf95c85f43c59f16984207523ba8/view"},"naics":{"codes":["335910"],"primary":"335910"},"title":"Battery Install and Replacement","agency":{"office":{"code":"FA9401","name":"FA9401 377 MSG PK"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"87117-0001","city":"KIRTLAND AFB","state":"NM","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-10-04","archive_type":"auto15"},"contacts":[{"name":"Abigail Turner","role":"primary","email":"abigail.turner.2@us.af.mil"},{"name":"Rachel Copeland","role":"secondary","email":"rachel.copeland.3@us.af.mil"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"40d3cf95c85f43c59f16984207523ba8","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"1f14a47c586f60a0651ccf5a1f015471a6260be96169b79e51e705d5a271007d","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"The Air Force has a requirement for the purchase of 12 sodium nickel battery modules to replace the existing battery modules. In addition, one 200-amp power inverter and 27 additional electrical outlets are required for the building. Contractor must remove and dispose of existing lead-acid batteries, provide Ethernet remote monitoring capabilities, remove and dispose of existing power inverters and purchase and install replacement power inverters, and purchase and install overhead electrical outlets located in the areas of the batteries and inverters. Critical requirement to be met is that the battery system be 48 volts and provide 5 hours of power at the 120 amp maximum load. Batteries must meet the following requirements: • Cycling Capability: 4.500 cycles (80% DOD) • Battery energy density 100÷120Wh/kg, 150-190Wh/lt • Shelf life (> 20 years) • Temperature Immunity (-40 ÷ +60°C) • No gas emissions • No flammable materials • No fire/water flood reaction • 100% recyclable • NO pollution materials • NO gas emissions Power inverters must be one 200-amp and one 100-amp for the two required power inverters for the building. Electrical outlets are to be 115V, 60 Hertz power.","origin":"extract"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"FA940124Q0035","place_of_performance":{"city":{"name":"Kirtland AFB"},"state":{"code":"NM"},"country":{"code":"USA"}},"product_service_code":"6140"},{"dates":{"posted":"2024-09-17","response_deadline":{"raw":"2024-09-19T14:00:00-06:00","utc":"2024-09-19T20:00:00Z","date":"2024-09-19","time":"14:00:00","utc_offset_seconds":-21600}},"links":{"sam":"https://sam.gov/workspace/contract/opp/47f6fc3eb55c42cc88ce24a547a91650/view"},"naics":{"codes":["335910"],"primary":"335910"},"title":"Battery Install and Replacement","agency":{"office":{"code":"FA9401","name":"FA9401 377 MSG PK"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"87117-0001","city":"KIRTLAND AFB","state":"NM","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-10-04","archive_type":"auto15"},"contacts":[{"name":"Abigail Turner","role":"primary","email":"abigail.turner.2@us.af.mil"},{"name":"Rachel Copeland","role":"secondary","email":"rachel.copeland.3@us.af.mil"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"47f6fc3eb55c42cc88ce24a547a91650","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"20dea921fc96aa51d13efc519e94f215927e12a93aeeea287509752361d89618","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"The Air Force has a requirement for the purchase of 12 sodium nickel battery modules to replace the existing battery modules. In addition, one 200-amp power inverter and 27 additional electrical outlets are required for the building. Contractor must remove and dispose of existing lead-acid batteries, provide Ethernet remote monitoring capabilities, remove and dispose of existing power inverters and purchase and install replacement power inverters, and purchase and install overhead electrical outlets located in the areas of the batteries and inverters. Critical requirement to be met is that the battery system be 48 volts and provide 5 hours of power at the 120 amp maximum load. Batteries must meet the following requirements: • Cycling Capability: 4.500 cycles (80% DOD) • Battery energy density 100÷120Wh/kg, 150-190Wh/lt • Shelf life (> 20 years) • Temperature Immunity (-40 ÷ +60°C) • No gas emissions • No flammable materials • No fire/water flood reaction • 100% recyclable • NO pollution materials • NO gas emissions Power inverters must be one 200-amp and one 100-amp for the two required power inverters for the building. Electrical outlets are to be 115V, 60 Hertz power.","origin":"extract"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"FA940124Q0035","place_of_performance":{"city":{"name":"Kirtland AFB"},"state":{"code":"NM"},"country":{"code":"USA"}},"product_service_code":"6140"}],"due_at":"2024-09-19T20:00:00Z","due_date":"2024-09-19","closes_at":"2024-09-19T20:00:00Z","awardable":true,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA9401","office_name":"FA9401 377 MSG PK","state":"NM","county":"35001","county_name":"Bernalillo County","city":"3536300","city_name":"Kirtland AFB","country":"USA","winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z","principal_notice_id":"47f6fc3eb55c42cc88ce24a547a91650","description":{"text":"The Air Force has a requirement for the purchase of 12 sodium nickel battery modules to replace the existing battery modules. In addition, one 200-amp power inverter and 27 additional electrical outlets are required for the building. Contractor must remove and dispose of existing lead-acid batteries, provide Ethernet remote monitoring capabilities, remove and dispose of existing power inverters and purchase and install replacement power inverters, and purchase and install overhead electrical outlets located in the areas of the batteries and inverters. Critical requirement to be met is that the battery system be 48 volts and provide 5 hours of power at the 120 amp maximum load. Batteries must meet the following requirements: • Cycling Capability: 4.500 cycles (80% DOD) • Battery energy density 100÷120Wh/kg, 150-190Wh/lt • Shelf life (> 20 years) • Temperature Immunity (-40 ÷ +60°C) • No gas emissions • No flammable materials • No fire/water flood reaction • 100% recyclable • NO pollution materials • NO gas emissions Power inverters must be one 200-amp and one 100-amp for the two required power inverters for the building. Electrical outlets are to be 115V, 60 Hertz power.","html":null,"origin":"extract"},"contacts":[{"name":"Abigail Turner","role":"primary","email":"abigail.turner.2@us.af.mil"},{"name":"Rachel Copeland","role":"secondary","email":"rachel.copeland.3@us.af.mil"}],"place_of_performance":{"city":{"name":"Kirtland AFB"},"state":{"code":"NM"},"country":{"code":"USA"}},"office_address":{"zip":"87117-0001","city":"KIRTLAND AFB","state":"NM","country":"USA"},"naics_codes":["335910"],"award":null,"attachments":[],"awards":[],"related":[{"key":"FA940126Q0043","latest_notice_id":"2a3c41b3f4af4f6ab78be6fc0d175316","title":"Wash Rack Utility Connection","solicitation_number":"FA940126Q0043","notice_type":"k","first_type":"k","first_posted":"2026-09-10","last_posted":"2026-09-14","notices":2,"due_at":"2026-09-22T19:00:00Z","due_date":"2026-09-22","closes_at":"2026-09-22T19:00:00Z","awardable":true,"open":true,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA9401","office_name":"FA9401 377 MSG PK","naics":"238210","psc":"Z2AZ","set_aside":"SBA","state":"NM","county":"35001","county_name":"Bernalillo County","city":"3536300","city_name":"Kirtland AFB","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"FA940126Q0027","latest_notice_id":"150c1812711b4bef920e24808ccbe403","title":"Lifeguard Services Indoor Pool","solicitation_number":"FA940126Q0027","notice_type":"k","first_type":"k","first_posted":"2026-08-19","last_posted":"2026-09-15","notices":4,"due_at":"2026-09-23T20:00:00Z","due_date":"2026-09-23","closes_at":"2026-09-23T20:00:00Z","awardable":true,"open":true,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA9401","office_name":"FA9401 377 MSG PK","naics":"713940","psc":"M1FB","set_aside":"SBA","state":"NM","county":"35001","county_name":"Bernalillo County","city":"3536300","city_name":"Kirtland AFB","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"FA940126R0024","latest_notice_id":"c83dcbb56b754251a115be6e3c299c7a","title":"Renovate Secure Facility B1049","solicitation_number":"FA9401-26-R-0024","notice_type":"k","first_type":"k","first_posted":"2026-08-11","last_posted":"2026-09-16","notices":7,"due_at":"2026-09-23T21:00:00Z","due_date":"2026-09-23","closes_at":"2026-09-23T21:00:00Z","awardable":true,"open":true,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA9401","office_name":"FA9401 377 MSG PK","naics":"236220","psc":"Z2AA","set_aside":"SBA","state":"NM","county":"35001","county_name":"Bernalillo County","city":"3536300","city_name":"Kirtland AFB","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-17T06:28:38.602097Z"}]}