{"canonical":"https://abierto.us/opportunities/fa857126q0079","key":"FA857126Q0079","url":"https://abierto.us/opportunities/fa857126q0079","title":"LIFT STATION REDESIGN B20128","solicitation_number":"FA857126Q0079","notice_type":"k","open":false,"response_deadline":"2026-07-17T16:00:00Z","first_posted":"2026-06-15","last_posted":"2026-07-10","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE AIR FORCE","office":"FA8571 MAINT CONTRACTING AFSC PZIM","naics":"237110","psc":"4540","set_aside":"SBA","place_state":"GA","winner":null,"award_amount":null,"publications":[{"notice_id":"49b748fb4b874f41bb5442ed7cff1da0","title":"LIFT STATION REDESIGN B20128","solicitation_number":"FA857126Q0079","notice_type":"k","base_type":"k","posted":"2026-06-15","posted_at":null,"due_at":"2026-06-22T16:00:00Z","due_date":"2026-06-22","cancelled":null,"archived":null,"archive_date":"2026-07-07","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/49b748fb4b874f41bb5442ed7cff1da0/view","enriched":false,"history":[]},{"notice_id":"08c40a1be70b4c64964662733b686285","title":"LIFT STATION REDESIGN B20128","solicitation_number":"FA857126Q0079","notice_type":"k","base_type":"k","posted":"2026-07-10","posted_at":null,"due_at":"2026-07-17T16:00:00Z","due_date":"2026-07-17","cancelled":null,"archived":null,"archive_date":"2026-08-01","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/08c40a1be70b4c64964662733b686285/view","enriched":false,"history":[]}],"latest_notice_id":"08c40a1be70b4c64964662733b686285","first_type":"k","notices":[{"dates":{"posted":"2026-06-15","response_deadline":{"raw":"2026-06-22T12:00:00-04:00","utc":"2026-06-22T16:00:00Z","date":"2026-06-22","time":"12:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/49b748fb4b874f41bb5442ed7cff1da0/view"},"naics":{"codes":["237110"],"primary":"237110"},"title":"LIFT STATION REDESIGN B20128","agency":{"office":{"code":"FA8571","name":"FA8571 MAINT CONTRACTING AFSC PZIM"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"31098-1672","city":"ROBINS AFB","state":"GA","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2026-07-07","archive_type":"auto15"},"contacts":[{"name":"Phillip Braswell","role":"primary","email":"phillip.braswell.1@us.af.mil"},{"name":"Andrew Harth","role":"secondary","email":"andrew.harth@us.af.mil"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"49b748fb4b874f41bb5442ed7cff1da0","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T16:22:53.920682Z","row_sha256":"744bf058e7d0cfd4ecb5d27815fe702551cefcfcf400db5fae337b4e4b98a394","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-16T16:22:53.920682Z","first_seen_at":"2026-09-16T16:22:53.920682Z"},"description":{"text":"The Contractor shall provide all the tools, parts, materials, equipment, labor, transportation, startup, and training for a redesigned lift station to the Commodities Maintenance Group (CMXG) at Robins Air Force Base (AFB), Georgia. These lift stations will be used to transport liquid chemical waste that could present environmental danger (i.e. acid waste, chrome waste). Each Lift Station shall have the following features: • Two (2) electric pumps made of CPVC or 316 Stainless Steel. Pump fittings must be CPVC with a two (2) inch maximum nominal size. The pump flowrate should be 25 gallons per minute per pump. The pump must have a 30-foot total dynamic head. • The tank material shall be polypropylene, with a volume of 50 to 75 gallons and a single tank containment style. • The dimensions of the lift station shall be four (4) feet long, three (3) feet wide, and four (4) feet high. • The control panel enclosure shall be made of stainless steel. • The power supply shall be 120V or 208V. • Each pump shall have disconnect switches, hands-off-auto, and level sensors for automation on/off pump operation.","origin":"extract"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"FA857126Q0079","place_of_performance":{"zip":"31098","city":{"name":"Warner Robins"},"state":{"code":"GA"},"country":{"code":"USA"}},"product_service_code":"4540"},{"dates":{"posted":"2026-07-10","response_deadline":{"raw":"2026-07-17T12:00:00-04:00","utc":"2026-07-17T16:00:00Z","date":"2026-07-17","time":"12:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/08c40a1be70b4c64964662733b686285/view"},"naics":{"codes":["237110"],"primary":"237110"},"title":"LIFT STATION REDESIGN B20128","agency":{"office":{"code":"FA8571","name":"FA8571 MAINT CONTRACTING AFSC PZIM"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"31098-1672","city":"ROBINS AFB","state":"GA","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2026-08-01","archive_type":"auto15"},"contacts":[{"name":"Phillip Braswell","role":"primary","email":"phillip.braswell.1@us.af.mil"},{"name":"Andrew Harth","role":"secondary","email":"andrew.harth@us.af.mil"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"08c40a1be70b4c64964662733b686285","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"0a847a1a2b736d6bd39952fdda07bcf22e4a8da019cc8aee8944c2b8f00a92a8","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-16T00:55:27.040971Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"text":"The Contractor shall provide all the tools, parts, materials, equipment, labor, transportation, startup, and training for a redesigned lift station to the Commodities Maintenance Group (CMXG) at Robins Air Force Base (AFB), Georgia. These lift stations will be used to transport liquid chemical waste that could present environmental danger (i.e. acid waste, chrome waste). Each Lift Station shall have the following features: • Two (2) electric pumps made of CPVC or 316 Stainless Steel. Pump fittings must be CPVC with a two (2) inch maximum nominal size. The pump flowrate should be 25 gallons per minute per pump. The pump must have a 30-foot total dynamic head. • The tank material shall be polypropylene, with a volume of 50 to 75 gallons and a single tank containment style. • The dimensions of the lift station shall be four (4) feet long, three (3) feet wide, and four (4) feet high. • The control panel enclosure shall be made of stainless steel. • The power supply shall be 120V or 208V. • Each pump shall have disconnect switches, hands-off-auto, and level sensors for automation on/off pump operation.","origin":"extract"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"FA857126Q0079","place_of_performance":{"zip":"31098","city":{"name":"Warner Robins"},"state":{"code":"GA"},"country":{"code":"USA"}},"product_service_code":"4540"}],"due_at":"2026-07-17T16:00:00Z","due_date":"2026-07-17","closes_at":"2026-07-17T16:00:00Z","awardable":true,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8571","office_name":"FA8571 MAINT CONTRACTING AFSC PZIM","state":"GA","country":"USA","winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T17:40:17.704408Z","principal_notice_id":"08c40a1be70b4c64964662733b686285","description":{"text":"The Contractor shall provide all the tools, parts, materials, equipment, labor, transportation, startup, and training for a redesigned lift station to the Commodities Maintenance Group (CMXG) at Robins Air Force Base (AFB), Georgia. These lift stations will be used to transport liquid chemical waste that could present environmental danger (i.e. acid waste, chrome waste). Each Lift Station shall have the following features: • Two (2) electric pumps made of CPVC or 316 Stainless Steel. Pump fittings must be CPVC with a two (2) inch maximum nominal size. The pump flowrate should be 25 gallons per minute per pump. The pump must have a 30-foot total dynamic head. • The tank material shall be polypropylene, with a volume of 50 to 75 gallons and a single tank containment style. • The dimensions of the lift station shall be four (4) feet long, three (3) feet wide, and four (4) feet high. • The control panel enclosure shall be made of stainless steel. • The power supply shall be 120V or 208V. • Each pump shall have disconnect switches, hands-off-auto, and level sensors for automation on/off pump operation.","html":null,"origin":"extract"},"contacts":[{"name":"Phillip Braswell","role":"primary","email":"phillip.braswell.1@us.af.mil"},{"name":"Andrew Harth","role":"secondary","email":"andrew.harth@us.af.mil"}],"place_of_performance":{"zip":"31098","city":{"name":"Warner Robins"},"state":{"code":"GA"},"country":{"code":"USA"}},"office_address":{"zip":"31098-1672","city":"ROBINS AFB","state":"GA","country":"USA"},"naics_codes":["237110"],"award":null,"attachments":[],"awards":[],"related":[{"key":"FA857126Q0118","latest_notice_id":"31d60462f5b94576b2aa9a3d1859eb6f","title":"Surfcam Annual Maintenance","solicitation_number":"FA857126Q0118","notice_type":"o","first_type":"o","first_posted":"2026-09-10","last_posted":"2026-09-10","notices":1,"due_at":"2026-09-21T16:00:00Z","due_date":"2026-09-21","closes_at":"2026-09-21T16:00:00Z","awardable":true,"open":true,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8571","office_name":"FA8571 MAINT CONTRACTING AFSC PZIM","naics":"513210","psc":"7A21","set_aside":null,"state":"GA","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T07:31:38.954589Z"},{"key":"FDB80566","latest_notice_id":"86027374e2a8495699eb894fe7b64592","title":"Stratasys Fortus units Calibration and Maintenance","solicitation_number":"FDB80566","notice_type":"r","first_type":"r","first_posted":"2026-09-10","last_posted":"2026-09-10","notices":1,"due_at":"2026-09-24T15:00:00Z","due_date":"2026-09-24","closes_at":"2026-09-24T15:00:00Z","awardable":true,"open":true,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8571","office_name":"FA8571 MAINT CONTRACTING AFSC PZIM","naics":null,"psc":null,"set_aside":null,"state":"GA","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T07:31:38.954589Z"},{"key":"FA857126Q0109","latest_notice_id":"e55dfe1912d440bc941c6ccdfe9794c3","title":"COMBO - C-5 Main Landing Gear Stands","solicitation_number":"FA857126Q0109","notice_type":"k","first_type":"k","first_posted":"2026-08-13","last_posted":"2026-09-11","notices":3,"due_at":"2026-09-25T19:00:00Z","due_date":"2026-09-25","closes_at":"2026-09-25T19:00:00Z","awardable":true,"open":true,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA8571","office_name":"FA8571 MAINT CONTRACTING AFSC PZIM","naics":"333120","psc":"5450","set_aside":"SBA","state":"GA","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T07:31:38.954589Z"}]}