{"canonical":"https://abierto.us/opportunities/fa487724q0016","key":"FA487724Q0016","url":"https://abierto.us/opportunities/fa487724q0016","title":"Server Rack Replacement and Cable Management","solicitation_number":"FA487724Q0016","notice_type":"o","open":false,"response_deadline":"2024-08-16T21:00:00Z","first_posted":"2024-08-02","last_posted":"2024-08-13","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE AIR FORCE","office":"FA4877 355 CONS PK","naics":"541519","psc":"R499","set_aside":"SBA","place_state":"AZ","place_county":"04019","place_county_name":"Pima County","place_city":"0477000","place_city_name":"Tucson","winner":"LAVA VALLEY SOLUTIONS LLC","award_amount":null,"publications":[{"notice_id":"db4f9173e10c4557a4ba55f7bccd45cf","title":"Server Rack Replacement and Cable Management","solicitation_number":"FA487724Q0016","notice_type":"o","base_type":"r","posted":"2024-08-02","posted_at":null,"due_at":"2024-08-14T21:00:00Z","due_date":"2024-08-14","cancelled":null,"archived":null,"archive_date":"2024-08-29","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/db4f9173e10c4557a4ba55f7bccd45cf/view","enriched":false,"history":[]},{"notice_id":"152d650bc4a3467999f57c0df063d183","title":"Server Rack Replacement and Cable Management","solicitation_number":"FA487724Q0016","notice_type":"o","base_type":"o","posted":"2024-08-06","posted_at":null,"due_at":"2024-08-14T21:00:00Z","due_date":"2024-08-14","cancelled":null,"archived":null,"archive_date":"2024-08-29","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/152d650bc4a3467999f57c0df063d183/view","enriched":false,"history":[]},{"notice_id":"1fe407af2c9546d2b4c7b0d3afaeba4d","title":"Server Rack Replacement and Cable Management","solicitation_number":"FA487724Q0016","notice_type":"o","base_type":"o","posted":"2024-08-06","posted_at":null,"due_at":"2024-08-14T21:00:00Z","due_date":"2024-08-14","cancelled":null,"archived":null,"archive_date":"2024-08-29","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/1fe407af2c9546d2b4c7b0d3afaeba4d/view","enriched":false,"history":[]},{"notice_id":"2819c154cbea4b56892093fe41b30ad5","title":"Server Rack Replacement and Cable Management","solicitation_number":"FA487724Q0016","notice_type":"o","base_type":"o","posted":"2024-08-06","posted_at":null,"due_at":"2024-08-14T21:00:00Z","due_date":"2024-08-14","cancelled":null,"archived":null,"archive_date":"2024-08-29","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/2819c154cbea4b56892093fe41b30ad5/view","enriched":false,"history":[]},{"notice_id":"1ef9a87bd50040a4ac67efc038247591","title":"Server Rack Replacement and Cable Management","solicitation_number":"FA487724Q0016","notice_type":"o","base_type":"o","posted":"2024-08-13","posted_at":null,"due_at":"2024-08-16T21:00:00Z","due_date":"2024-08-16","cancelled":null,"archived":null,"archive_date":"2024-08-31","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/1ef9a87bd50040a4ac67efc038247591/view","enriched":false,"history":[]}],"latest_notice_id":"1ef9a87bd50040a4ac67efc038247591","first_type":"o","notices":[{"dates":{"posted":"2024-08-02","response_deadline":{"raw":"2024-08-14T14:00:00-07:00","utc":"2024-08-14T21:00:00Z","date":"2024-08-14","time":"14:00:00","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/db4f9173e10c4557a4ba55f7bccd45cf/view"},"naics":{"codes":["541519"],"primary":"541519"},"title":"Server Rack Replacement and Cable Management","agency":{"office":{"code":"FA4877","name":"FA4877 355 CONS PK"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"85707-3522","city":"DAVIS MONTHAN AFB","state":"AZ","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-08-29","archive_type":"auto15"},"contacts":[{"name":"Cody Daraban","role":"primary","email":"cody.daraban@us.af.mil","phone":"5202283704"},{"name":"Joshua Lewis","role":"secondary","email":"joshua.lewis.44@us.af.mil","phone":"5202284190"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"db4f9173e10c4557a4ba55f7bccd45cf","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"ec1d743d0af604c3584621921a7f8a46cf9b968c0fc2f14b4e76a11c034caee7","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"The 355th Communications Squadron is looking to replace several server racks and have cable management/clean-up services performed in the same racks that are being replaced. The Contractor shall provide all required transportation, personnel, equipment, tools, parts, labor, appropriate supervision, and management needed to accomplish the work requested. A site survey shall be conducted prior to final purchase of necessary equipment to ensure all racks and fiber optic cable for replacement are properly identified and any concerns with facility or overall install are to be addressed. The total count of racks that are to be replaced is 11, 7 in Row #1 Racks 7-14A (rack 11 does not exist) and 4 in Row #2 Racks 1-4: - The replacements must include the following: o 42U data center cabinet supporting 19” rack mounted equipment. o Nominal width should be at least 29” with a front opening of at least 25”. o Nominal depth should be at least 39” with rail depth up to 36”. o Must have adjustable rails. o Must have a single perforated front door and a double perforated rear door, both with lockable key latches. o The top panel must have 4 cable openings, one at each corner, with included grommets. o Must have 4 vertical cable managers with fingers aligning between each U that are also in-line with the top panel's cable openings but do not interfere with the installation or removal of rack mounted equipment. o Must come with enough cage nuts and screws to populate every slot on all 4 rails. o Must come with a vertical PDU, mounted securely, supporting 48 NEMA 5-20 outlets and a NEMA L6-30 input plug. - Remove equipment from old racks and reinstall in the replacements. - Dispose of the old server racks. The contractor will conduct the following regarding cable management and clean up: - Replace and organize all connections in Row #1 Racks 7-14A (rack 11 doesn't exist) and Row #2 Racks 1-4. - Utilize maintenance loops using existing cable trays to provide neatness, accessibility, and to allow freedom of movement for future serviceability. - Properly identify cables in accordance with ANSI/TIA-606-C to include identifying: o Pathways o Patch panels o Ports o Cabling o Telecommunications space o Work area outlets o Racks and cabinets o Grounding busbars o Firestop locations o Data center room grid - Update LIU/patch panel labels and legend inserts.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"FA487724Q0016","place_of_performance":{"zip":"85708","city":{"name":"Tucson"},"state":{"code":"AZ"},"country":{"code":"USA"}},"product_service_code":"R499"},{"dates":{"posted":"2024-08-06","response_deadline":{"raw":"2024-08-14T14:00:00-07:00","utc":"2024-08-14T21:00:00Z","date":"2024-08-14","time":"14:00:00","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/152d650bc4a3467999f57c0df063d183/view"},"naics":{"codes":["541519"],"primary":"541519"},"title":"Server Rack Replacement and Cable Management","agency":{"office":{"code":"FA4877","name":"FA4877 355 CONS PK"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"85707-3522","city":"DAVIS MONTHAN AFB","state":"AZ","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-08-29","archive_type":"auto15"},"contacts":[{"name":"Cody Daraban","role":"primary","email":"cody.daraban@us.af.mil","phone":"5202283704"},{"name":"Joshua Lewis","role":"secondary","email":"joshua.lewis.44@us.af.mil","phone":"5202284190"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"152d650bc4a3467999f57c0df063d183","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"1aa954f0d7f84e26365838804559d5dbce65501f931ae656079d4a8678d664ef","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"The 355th Communications Squadron is looking to replace several server racks and have cable management/clean-up services performed in the same racks that are being replaced. The Contractor shall provide all required transportation, personnel, equipment, tools, parts, labor, appropriate supervision, and management needed to accomplish the work requested. A site survey shall be conducted prior to final purchase of necessary equipment to ensure all racks and fiber optic cable for replacement are properly identified and any concerns with facility or overall install are to be addressed. The total count of racks that are to be replaced is 11, 7 in Row #1 Racks 7-14A (rack 11 does not exist) and 4 in Row #2 Racks 1-4: - The replacements must include the following: o 42U data center cabinet supporting 19” rack mounted equipment. o Nominal width should be at least 29” with a front opening of at least 25”. o Nominal depth should be at least 39” with rail depth up to 36”. o Must have adjustable rails. o Must have a single perforated front door and a double perforated rear door, both with lockable key latches. o The top panel must have 4 cable openings, one at each corner, with included grommets. o Must have 4 vertical cable managers with fingers aligning between each U that are also in-line with the top panel's cable openings but do not interfere with the installation or removal of rack mounted equipment. o Must come with enough cage nuts and screws to populate every slot on all 4 rails. o Must come with a vertical PDU, mounted securely, supporting 48 NEMA 5-20 outlets and a NEMA L6-30 input plug. - Remove equipment from old racks and reinstall in the replacements. - Dispose of the old server racks. The contractor will conduct the following regarding cable management and clean up: - Replace and organize all connections in Row #1 Racks 7-14A (rack 11 doesn't exist) and Row #2 Racks 1-4. - Utilize maintenance loops using existing cable trays to provide neatness, accessibility, and to allow freedom of movement for future serviceability. - Properly identify cables in accordance with ANSI/TIA-606-C to include identifying: o Pathways o Patch panels o Ports o Cabling o Telecommunications space o Work area outlets o Racks and cabinets o Grounding busbars o Firestop locations o Data center room grid - Update LIU/patch panel labels and legend inserts.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"FA487724Q0016","place_of_performance":{"zip":"85708","city":{"name":"Tucson"},"state":{"code":"AZ"},"country":{"code":"USA"}},"product_service_code":"R499"},{"dates":{"posted":"2024-08-06","response_deadline":{"raw":"2024-08-14T14:00:00-07:00","utc":"2024-08-14T21:00:00Z","date":"2024-08-14","time":"14:00:00","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/1fe407af2c9546d2b4c7b0d3afaeba4d/view"},"naics":{"codes":["541519"],"primary":"541519"},"title":"Server Rack Replacement and Cable Management","agency":{"office":{"code":"FA4877","name":"FA4877 355 CONS PK"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"85707-3522","city":"DAVIS MONTHAN AFB","state":"AZ","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-08-29","archive_type":"auto15"},"contacts":[{"name":"Cody Daraban","role":"primary","email":"cody.daraban@us.af.mil","phone":"5202283704"},{"name":"Joshua Lewis","role":"secondary","email":"joshua.lewis.44@us.af.mil","phone":"5202284190"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"1fe407af2c9546d2b4c7b0d3afaeba4d","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"a186fa18d2230e0b29a47904a041b07c483b98c7ad8e34a281ed2d01bd560201","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"The 355th Communications Squadron is looking to replace several server racks and have cable management/clean-up services performed in the same racks that are being replaced. The Contractor shall provide all required transportation, personnel, equipment, tools, parts, labor, appropriate supervision, and management needed to accomplish the work requested. A site survey shall be conducted prior to final purchase of necessary equipment to ensure all racks and fiber optic cable for replacement are properly identified and any concerns with facility or overall install are to be addressed. The total count of racks that are to be replaced is 11, 7 in Row #1 Racks 7-14A (rack 11 does not exist) and 4 in Row #2 Racks 1-4: - The replacements must include the following: o 42U data center cabinet supporting 19” rack mounted equipment. o Nominal width should be at least 29” with a front opening of at least 25”. o Nominal depth should be at least 39” with rail depth up to 36”. o Must have adjustable rails. o Must have a single perforated front door and a double perforated rear door, both with lockable key latches. o The top panel must have 4 cable openings, one at each corner, with included grommets. o Must have 4 vertical cable managers with fingers aligning between each U that are also in-line with the top panel's cable openings but do not interfere with the installation or removal of rack mounted equipment. o Must come with enough cage nuts and screws to populate every slot on all 4 rails. o Must come with a vertical PDU, mounted securely, supporting 48 NEMA 5-20 outlets and a NEMA L6-30 input plug. - Remove equipment from old racks and reinstall in the replacements. - Dispose of the old server racks. The contractor will conduct the following regarding cable management and clean up: - Replace and organize all connections in Row #1 Racks 7-14A (rack 11 doesn't exist) and Row #2 Racks 1-4. - Utilize maintenance loops using existing cable trays to provide neatness, accessibility, and to allow freedom of movement for future serviceability. - Properly identify cables in accordance with ANSI/TIA-606-C to include identifying: o Pathways o Patch panels o Ports o Cabling o Telecommunications space o Work area outlets o Racks and cabinets o Grounding busbars o Firestop locations o Data center room grid - Update LIU/patch panel labels and legend inserts.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"FA487724Q0016","place_of_performance":{"zip":"85708","city":{"name":"Tucson"},"state":{"code":"AZ"},"country":{"code":"USA"}},"product_service_code":"R499"},{"dates":{"posted":"2024-08-06","response_deadline":{"raw":"2024-08-14T14:00:00-07:00","utc":"2024-08-14T21:00:00Z","date":"2024-08-14","time":"14:00:00","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/2819c154cbea4b56892093fe41b30ad5/view"},"naics":{"codes":["541519"],"primary":"541519"},"title":"Server Rack Replacement and Cable Management","agency":{"office":{"code":"FA4877","name":"FA4877 355 CONS PK"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"85707-3522","city":"DAVIS MONTHAN AFB","state":"AZ","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-08-29","archive_type":"auto15"},"contacts":[{"name":"Cody Daraban","role":"primary","email":"cody.daraban@us.af.mil","phone":"5202283704"},{"name":"Joshua Lewis","role":"secondary","email":"joshua.lewis.44@us.af.mil","phone":"5202284190"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"2819c154cbea4b56892093fe41b30ad5","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"383424d83954367b1ef4c67b325c65ac0c6040d2382ae2d5b456146cbd275899","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"The 355th Communications Squadron is looking to replace several server racks and have cable management/clean-up services performed in the same racks that are being replaced. The Contractor shall provide all required transportation, personnel, equipment, tools, parts, labor, appropriate supervision, and management needed to accomplish the work requested. A site survey shall be conducted prior to final purchase of necessary equipment to ensure all racks and fiber optic cable for replacement are properly identified and any concerns with facility or overall install are to be addressed. The total count of racks that are to be replaced is 11, 7 in Row #1 Racks 7-14A (rack 11 does not exist) and 4 in Row #2 Racks 1-4: - The replacements must include the following: o 42U data center cabinet supporting 19” rack mounted equipment. o Nominal width should be at least 29” with a front opening of at least 25”. o Nominal depth should be at least 39” with rail depth up to 36”. o Must have adjustable rails. o Must have a single perforated front door and a double perforated rear door, both with lockable key latches. o The top panel must have 4 cable openings, one at each corner, with included grommets. o Must have 4 vertical cable managers with fingers aligning between each U that are also in-line with the top panel's cable openings but do not interfere with the installation or removal of rack mounted equipment. o Must come with enough cage nuts and screws to populate every slot on all 4 rails. o Must come with a vertical PDU, mounted securely, supporting 48 NEMA 5-20 outlets and a NEMA L6-30 input plug. - Remove equipment from old racks and reinstall in the replacements. - Dispose of the old server racks. The contractor will conduct the following regarding cable management and clean up: - Replace and organize all connections in Row #1 Racks 7-14A (rack 11 doesn't exist) and Row #2 Racks 1-4. - Utilize maintenance loops using existing cable trays to provide neatness, accessibility, and to allow freedom of movement for future serviceability. - Properly identify cables in accordance with ANSI/TIA-606-C to include identifying: o Pathways o Patch panels o Ports o Cabling o Telecommunications space o Work area outlets o Racks and cabinets o Grounding busbars o Firestop locations o Data center room grid - Update LIU/patch panel labels and legend inserts.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"FA487724Q0016","place_of_performance":{"zip":"85708","city":{"name":"Tucson"},"state":{"code":"AZ"},"country":{"code":"USA"}},"product_service_code":"R499"},{"dates":{"posted":"2024-08-13","response_deadline":{"raw":"2024-08-16T14:00:00-07:00","utc":"2024-08-16T21:00:00Z","date":"2024-08-16","time":"14:00:00","utc_offset_seconds":-25200}},"links":{"sam":"https://sam.gov/workspace/contract/opp/1ef9a87bd50040a4ac67efc038247591/view"},"naics":{"codes":["541519"],"primary":"541519"},"title":"Server Rack Replacement and Cable Management","agency":{"office":{"code":"FA4877","name":"FA4877 355 CONS PK"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"85707-3522","city":"DAVIS MONTHAN AFB","state":"AZ","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2024-08-31","archive_type":"auto15"},"contacts":[{"name":"Cody Daraban","role":"primary","email":"cody.daraban@us.af.mil","phone":"5202283704"},{"name":"Joshua Lewis","role":"secondary","email":"joshua.lewis.44@us.af.mil","phone":"5202284190"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"1ef9a87bd50040a4ac67efc038247591","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2024_archived_opportunities.csv","etag":"\"d582488fe153a9f11bf629913d176ffc-137\"","fetched_at":"2026-09-16T19:07:39.720164Z","row_sha256":"852663cc3c1026229050d0288d032e9ce175b8339c4183d03ddec52187bf9672","last_modified":"2026-09-13T14:47:40Z"},"updated_at":"2026-09-16T19:07:39.720164Z","first_seen_at":"2026-09-16T19:07:39.720164Z"},"description":{"text":"The 355th Communications Squadron (355 CS), Davis-Monthan AFB (DMAFB), requires the contractor to replace 4 server racks and perform cable management on 11 racks in 355 CS data center. The contractor will provide a proposed Performance Work Statement (PWS) as part of its quotation, proposed period of performance, personnel, equipment, tools, parts, labor, supervision, management, and transportation necessary to accomplish server rack replacement and cable management services. The total number of racks to be replaced is four, in Row #2, Racks 1-4. The contractor will remove the equipment from the existing racks, dispose of the existing racks, install new racks, and replace the equipment on the new racks. The replacement racks must include the following: 42U data center cabinet supporting 19” rack mounted equipment with the ability to accept rack cage nuts. Nominal width should be at least 29” with a front opening of at least 25”. Nominal depth should be at least 39” with rail depth up to 36”. Have adjustable rails. Have a single perforated front door and a double perforated rear door, both with lockable key latches. The top panel must have 4 cable openings, one at each corner, with included grommets. Must have 4 vertical cable managers with fingers aligning between each U that are also in-line with the top panel’s cable openings but do not interfere with the installation or removal of rack mounted equipment. Must come with enough cage nuts and screws to populate every slot on all 4 rails. Must come with 2 vertical mounted PDUs (zero U), mounted securely, supporting 24 NEMA 5-20 outputs at 120V and a NEMA L5-30P input at 120V with the ability to be actively monitored via SNMP. The contractor will perform the following regarding cable management. Replace and organize all connections in Row #1, Racks 7-14A (rack 11 doesn’t exist) and Row #2, Racks 1-4. Utilize maintenance loops using existing cable trays to provide neatness, accessibility, and to allow freedom of movement for future serviceability. Properly identify cables in accordance with ANSI/TIA-606-C to include identifying: Pathways Patch panels Ports Cabling Telecommunications space Work area outlets Racks and cabinets Grounding busbars Firestop locations Data center room grid Update LIU/patch panel labels and legend inserts.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"FA487724Q0016","place_of_performance":{"zip":"85708","city":{"name":"Tucson"},"state":{"code":"AZ"},"country":{"code":"USA"}},"product_service_code":"R499"}],"due_at":"2024-08-16T21:00:00Z","due_date":"2024-08-16","closes_at":"2024-08-16T21:00:00Z","awardable":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA4877","office_name":"FA4877 355 CONS PK","state":"AZ","county":"04019","county_name":"Pima County","city":"0477000","city_name":"Tucson","country":"USA","winner_key":"QFZ8VKT1MKD4","amount":null,"linked_awards":5,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z","principal_notice_id":"1ef9a87bd50040a4ac67efc038247591","description":{"text":"The 355th Communications Squadron (355 CS), Davis-Monthan AFB (DMAFB), requires the contractor to replace 4 server racks and perform cable management on 11 racks in 355 CS data center. The contractor will provide a proposed Performance Work Statement (PWS) as part of its quotation, proposed period of performance, personnel, equipment, tools, parts, labor, supervision, management, and transportation necessary to accomplish server rack replacement and cable management services. The total number of racks to be replaced is four, in Row #2, Racks 1-4. The contractor will remove the equipment from the existing racks, dispose of the existing racks, install new racks, and replace the equipment on the new racks. The replacement racks must include the following: 42U data center cabinet supporting 19” rack mounted equipment with the ability to accept rack cage nuts. Nominal width should be at least 29” with a front opening of at least 25”. Nominal depth should be at least 39” with rail depth up to 36”. Have adjustable rails. Have a single perforated front door and a double perforated rear door, both with lockable key latches. The top panel must have 4 cable openings, one at each corner, with included grommets. Must have 4 vertical cable managers with fingers aligning between each U that are also in-line with the top panel’s cable openings but do not interfere with the installation or removal of rack mounted equipment. Must come with enough cage nuts and screws to populate every slot on all 4 rails. Must come with 2 vertical mounted PDUs (zero U), mounted securely, supporting 24 NEMA 5-20 outputs at 120V and a NEMA L5-30P input at 120V with the ability to be actively monitored via SNMP. The contractor will perform the following regarding cable management. Replace and organize all connections in Row #1, Racks 7-14A (rack 11 doesn’t exist) and Row #2, Racks 1-4. Utilize maintenance loops using existing cable trays to provide neatness, accessibility, and to allow freedom of movement for future serviceability. Properly identify cables in accordance with ANSI/TIA-606-C to include identifying: Pathways Patch panels Ports Cabling Telecommunications space Work area outlets Racks and cabinets Grounding busbars Firestop locations Data center room grid Update LIU/patch panel labels and legend inserts.","html":null,"origin":"extract"},"contacts":[{"name":"Cody Daraban","role":"primary","email":"cody.daraban@us.af.mil","phone":"5202283704"},{"name":"Joshua Lewis","role":"secondary","email":"joshua.lewis.44@us.af.mil","phone":"5202284190"}],"place_of_performance":{"zip":"85708","city":{"name":"Tucson"},"state":{"code":"AZ"},"country":{"code":"USA"}},"office_address":{"zip":"85707-3522","city":"DAVIS MONTHAN AFB","state":"AZ","country":"USA"},"naics_codes":["541519"],"award":null,"attachments":[],"awards":[{"award_key":"CONT_AWD_FA487724P0130_9700_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_FA487724P0130_9700_-NONE-_-NONE-/","piid":"FA487724P0130","parent_piid":null,"award_type":"PURCHASE ORDER","vendor_key":"QFZ8VKT1MKD4","recipient_name":"LAVA VALLEY SOLUTIONS LLC","recipient_uei":"QFZ8VKT1MKD4","recipient_cage":"9XMU7","recipient_city":"BENSON","recipient_state":"AZ","sub_name":"Department of the Air Force","office_name":"FA4877 355 CONS PK","office_key":"o-FA4877","first_action_date":"2024-09-04","last_action_date":"2024-09-04","actions":1,"obligated":"116521.60","current_total_value":"116521.60","potential_total_value":"116521.60","naics":"541519","psc":"R499","extent_competed":"COMPETED UNDER SAP","set_aside":"SMALL BUSINESS SET ASIDE - TOTAL","offers_received":6,"description":"THE 355TH COMMUNICATIONS SQUADRON IS LOOKING TO REPLACE SEVERAL SERVER RACKS AND HAVE CABLE MANAGEMENT/CLEAN-UP SERVICES PERFORMED IN THE SAME RACKS THAT ARE BEING REPLACED.","method":"solicitation","confidence":"high","evidence":["solicitation number FA487724Q0016 equals the FPDS solicitation identifier","same awarding office FA4877"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"FA487726QA110","latest_notice_id":"6e22d637ee994ad8bd8821307f044f04","title":"79 RGS - Carpet Replacement/Installation B4851","solicitation_number":"FA487726QA110","notice_type":"o","first_type":"o","first_posted":"2026-09-09","last_posted":"2026-09-15","notices":2,"due_at":"2026-09-18T02:00:00Z","due_date":"2026-09-17","closes_at":"2026-09-18T02:00:00Z","awardable":true,"open":true,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA4877","office_name":"FA4877 355 CONS PK","naics":"314110","psc":"7220","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"}]}