{"canonical":"https://abierto.us/opportunities/fa452826qsp03","key":"FA452826QSP03","url":"https://abierto.us/opportunities/fa452826qsp03","title":"Bulk Oil/Coolant Storage & Dispenser System","solicitation_number":"FA452826QSP03","notice_type":"k","open":false,"response_deadline":"2026-07-30T16:00:00Z","first_posted":"2026-07-28","last_posted":"2026-07-28","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE AIR FORCE","office":"FA4528 5 CONS","naics":"332420","psc":"5430","set_aside":"SBA","place_state":"ND","place_county":"38101","place_county_name":"Ward County","place_city":"3853420","place_city_name":"Minot AFB","winner":null,"award_amount":null,"publications":[{"notice_id":"5155fb065b104a70887030f3f6843b8c","title":"Bulk Oil/Coolant Storage & Dispenser System","solicitation_number":"FA452826QSP03","notice_type":"k","base_type":"k","posted":"2026-07-28","posted_at":null,"due_at":"2026-07-30T21:00:00Z","due_date":"2026-07-30","cancelled":null,"archived":null,"archive_date":"2026-08-14","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/5155fb065b104a70887030f3f6843b8c/view","enriched":false,"history":[]},{"notice_id":"653e11fb4d3547b791989a132627a7b1","title":"Bulk Oil/Coolant Storage & Dispenser System","solicitation_number":"FA452826QSP03","notice_type":"k","base_type":"k","posted":"2026-07-28","posted_at":null,"due_at":"2026-07-30T16:00:00Z","due_date":"2026-07-30","cancelled":null,"archived":null,"archive_date":"2026-08-14","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/653e11fb4d3547b791989a132627a7b1/view","enriched":false,"history":[]}],"latest_notice_id":"653e11fb4d3547b791989a132627a7b1","first_type":"k","notices":[{"dates":{"posted":"2026-07-28","response_deadline":{"raw":"2026-07-30T16:00:00-05:00","utc":"2026-07-30T21:00:00Z","date":"2026-07-30","time":"16:00:00","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/5155fb065b104a70887030f3f6843b8c/view"},"naics":{"codes":["332420"],"primary":"332420"},"title":"Bulk Oil/Coolant Storage & Dispenser System","agency":{"office":{"code":"FA4528","name":"FA4528 5 CONS"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"58705","city":"MINOT AFB","state":"ND","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2026-08-14","archive_type":"auto15"},"contacts":[{"name":"Sherry L. Platt","role":"primary","email":"sherry.platt.1@us.af.mil","phone":"7017232139"},{"name":"Ted Arneson","role":"secondary","email":"theodore.arneson@us.af.mil","phone":"7017233949"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"5155fb065b104a70887030f3f6843b8c","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"4a8fafca683d871ab127d8bf8ec6dcc177c2d67947bb65b5b87fa7f57fbc59b6","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-16T00:55:27.040971Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"text":"The Government is soliciting quotes for a modular fluid storage and dispensing system (delivery only) that meets the essential characteristics outlined in the attachments. The required system must fit within a 12’W x 9’D x 10’H footprint, operate entirely on facility compressed air, and secure four (4) 120-gallon aluminized steel tanks (3 Black for oil, 1 Blue for coolant). The system must accommodate three different types of oil and one coolant. Key functional requirements include: Two (2) pneumatic pumps: One AODD pump dedicated to the coolant line, and one Gear/Piston pump for the oil line. An oil selector manifold: The oil pump must draw from a manifold connecting the three oil tanks, utilizing three 2-way isolation ball valves to select the desired fluid and prevent cross-contamination. Two (2) 50ft hose reels: One reel dedicated to coolant and one shared reel for the three oil types. A mandatory purge/flush line: The oil hose reel system must include a purge line or return valve, equal in diameter to the hose, to clear the line of residual fluid when switching between oil types. Independent 10-micron filtration: Dedicated, independent 10-micron inline filters with isolation valves must be installed on both the oil and coolant lines. Safety features must include color-change desiccant breathers, isolated sight gauges, drip pans, and a spill containment pallet capable of holding a minimum of 130 gallons. Quotes for \"or equal\" products will be evaluated provided they meet all specified characteristics.","origin":"extract"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"FA452826QSP03","place_of_performance":{"zip":"58704","city":{"name":"Minot AFB"},"state":{"code":"ND"},"country":{"code":"USA"}},"product_service_code":"5430"},{"dates":{"posted":"2026-07-28","response_deadline":{"raw":"2026-07-30T11:00:00-05:00","utc":"2026-07-30T16:00:00Z","date":"2026-07-30","time":"11:00:00","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/653e11fb4d3547b791989a132627a7b1/view"},"naics":{"codes":["332420"],"primary":"332420"},"title":"Bulk Oil/Coolant Storage & Dispenser System","agency":{"office":{"code":"FA4528","name":"FA4528 5 CONS"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"58705","city":"MINOT AFB","state":"ND","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2026-08-14","archive_type":"auto15"},"contacts":[{"name":"Sherry L. Platt","role":"primary","email":"sherry.platt.1@us.af.mil","phone":"7017232139"},{"name":"Ted Arneson","role":"secondary","email":"theodore.arneson@us.af.mil","phone":"7017233949"}],"base_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"notice_id":"653e11fb4d3547b791989a132627a7b1","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2026_archived_opportunities.csv","etag":"\"d9374b90a938e9923d910594731b7b57-106\"","fetched_at":"2026-09-16T00:55:27.040971Z","row_sha256":"1bef7c81aadda0d901d40d1a15001a5bc0ccfa94b298eff63de2e6456a64e668","last_modified":"2026-09-13T14:50:39Z"},"updated_at":"2026-09-16T00:55:27.040971Z","first_seen_at":"2026-09-16T00:55:27.040971Z"},"description":{"text":"The Government is soliciting quotes for a modular fluid storage and dispensing system (delivery only) that meets the essential characteristics outlined in the attachments. The required system must fit within a 12’W x 9’D x 10’H footprint, operate entirely on facility compressed air, and secure four (4) 120-gallon aluminized steel tanks (3 Black for oil, 1 Blue for coolant). The system must accommodate three different types of oil and one coolant. Key functional requirements include: Two (2) pneumatic pumps: One AODD pump dedicated to the coolant line, and one Gear/Piston pump for the oil line. An oil selector manifold: The oil pump must draw from a manifold connecting the three oil tanks, utilizing three 2-way isolation ball valves to select the desired fluid and prevent cross-contamination. Two (2) 50ft hose reels: One reel dedicated to coolant and one shared reel for the three oil types. A mandatory purge/flush line: The oil hose reel system must include a purge line or return valve, equal in diameter to the hose, to clear the line of residual fluid when switching between oil types. Independent 10-micron filtration: Dedicated, independent 10-micron inline filters with isolation valves must be installed on both the oil and coolant lines. Safety features must include color-change desiccant breathers, isolated sight gauges, drip pans, and a spill containment pallet capable of holding a minimum of 130 gallons. Quotes for \"or equal\" products will be evaluated provided they meet all specified characteristics.","origin":"extract"},"notice_type":{"code":"k","label":"Combined Synopsis/Solicitation"},"schema_version":1,"solicitation_number":"FA452826QSP03","place_of_performance":{"zip":"58704","city":{"name":"Minot AFB"},"state":{"code":"ND"},"country":{"code":"USA"}},"product_service_code":"5430"}],"due_at":"2026-07-30T16:00:00Z","due_date":"2026-07-30","closes_at":"2026-07-30T16:00:00Z","awardable":true,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA4528","office_name":"FA4528 5 CONS","state":"ND","county":"38101","county_name":"Ward County","city":"3853420","city_name":"Minot AFB","country":"USA","winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z","principal_notice_id":"653e11fb4d3547b791989a132627a7b1","description":{"text":"The Government is soliciting quotes for a modular fluid storage and dispensing system (delivery only) that meets the essential characteristics outlined in the attachments. The required system must fit within a 12’W x 9’D x 10’H footprint, operate entirely on facility compressed air, and secure four (4) 120-gallon aluminized steel tanks (3 Black for oil, 1 Blue for coolant). The system must accommodate three different types of oil and one coolant. Key functional requirements include: Two (2) pneumatic pumps: One AODD pump dedicated to the coolant line, and one Gear/Piston pump for the oil line. An oil selector manifold: The oil pump must draw from a manifold connecting the three oil tanks, utilizing three 2-way isolation ball valves to select the desired fluid and prevent cross-contamination. Two (2) 50ft hose reels: One reel dedicated to coolant and one shared reel for the three oil types. A mandatory purge/flush line: The oil hose reel system must include a purge line or return valve, equal in diameter to the hose, to clear the line of residual fluid when switching between oil types. Independent 10-micron filtration: Dedicated, independent 10-micron inline filters with isolation valves must be installed on both the oil and coolant lines. Safety features must include color-change desiccant breathers, isolated sight gauges, drip pans, and a spill containment pallet capable of holding a minimum of 130 gallons. Quotes for \"or equal\" products will be evaluated provided they meet all specified characteristics.","html":null,"origin":"extract"},"contacts":[{"name":"Sherry L. Platt","role":"primary","email":"sherry.platt.1@us.af.mil","phone":"7017232139"},{"name":"Ted Arneson","role":"secondary","email":"theodore.arneson@us.af.mil","phone":"7017233949"}],"place_of_performance":{"zip":"58704","city":{"name":"Minot AFB"},"state":{"code":"ND"},"country":{"code":"USA"}},"office_address":{"zip":"58705","city":"MINOT AFB","state":"ND","country":"USA"},"naics_codes":["332420"],"award":null,"attachments":[],"awards":[],"related":[{"key":"FA452826RB0003","latest_notice_id":"bd06c14105ca46ffa9de27109c209f52","title":"Building 445 Office Furniture Replacement","solicitation_number":"FA452826RB0003","notice_type":"k","first_type":"k","first_posted":"2026-09-11","last_posted":"2026-09-15","notices":2,"due_at":"2026-09-18T18:00:00Z","due_date":"2026-09-18","closes_at":"2026-09-18T18:00:00Z","awardable":true,"open":true,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA4528","office_name":"FA4528 5 CONS","naics":"337215","psc":"7110","set_aside":"SBA","state":"ND","county":"38101","county_name":"Ward County","city":"3853420","city_name":"Minot AFB","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"FA452826Q0010","latest_notice_id":"9f16080cbc2743ae9802b7dfdd321f76","title":"EOD Nuclear Response Trailer","solicitation_number":"FA452826Q0010","notice_type":"o","first_type":"o","first_posted":"2026-09-02","last_posted":"2026-09-02","notices":1,"due_at":"2026-09-22T18:00:00Z","due_date":"2026-09-22","closes_at":"2026-09-22T18:00:00Z","awardable":true,"open":true,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA4528","office_name":"FA4528 5 CONS","naics":"336214","psc":"2330","set_aside":"SBA","state":"ND","county":"38101","county_name":"Ward County","city":"3853420","city_name":"Minot AFB","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"FA452826R0002","latest_notice_id":"c392ada23e564e9d9d90c20f474b10cb","title":"Minot Air Force Base Multiple Award Construction Contract (MACC) IDIQ","solicitation_number":"FA452826R0002","notice_type":"o","first_type":"o","first_posted":"2026-08-19","last_posted":"2026-08-19","notices":1,"due_at":"2026-09-28T14:00:00Z","due_date":"2026-09-28","closes_at":"2026-09-28T14:00:00Z","awardable":true,"open":true,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA4528","office_name":"FA4528 5 CONS","naics":"236220","psc":"Y1JZ","set_aside":"SBA","state":"ND","county":"38101","county_name":"Ward County","city":"3853420","city_name":"Minot AFB","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"}]}