{"canonical":"https://abierto.us/opportunities/a070764ss","key":"A070764SS","url":"https://abierto.us/opportunities/a070764ss","title":"Brand Name or Equal - WaterFurnace Model: UBH015R for B3631 & B3635 - Turnkey Replacement","solicitation_number":"A070764SS","notice_type":"r","open":false,"removed":false,"removed_at":null,"response_deadline":"2026-10-26T17:00:00Z","first_posted":"2026-10-14","last_posted":"2026-10-14","department":"DEPT OF DEFENSE","subagency":"DEPT OF THE AIR FORCE","office":"FA3016 502 CONS CL","naics":"238220","psc":"4120","set_aside":null,"place_state":"TX","place_scope":"nationwide","site":null,"place_state_source":null,"place_evidence":null,"place_county":"48029","place_county_name":"Bexar County","place_city":null,"place_city_name":null,"winner":null,"award_amount":null,"publications":[{"notice_id":"0cf9b5fda9a54bd98114c40774127a2f","title":"Brand Name or Equal - WaterFurnace Model: UBH015R for B3631 & B3635 - Turnkey Replacement","solicitation_number":"A070764SS","notice_type":"r","base_type":"r","posted":"2026-10-14","posted_at":"2026-10-14T15:06:18.533Z","due_at":"2026-10-26T17:00:00Z","due_date":"2026-10-26","cancelled":false,"archived":false,"archive_date":"2026-11-10","removed_at":null,"award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/0cf9b5fda9a54bd98114c40774127a2f/view","enriched":true,"history":[{"index":1,"title":"Brand Name or Equal - WaterFurnace Model: UBH015R for B3631 & B3635 - Turnkey Replacement","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-14T15:06:18.533Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"0cf9b5fda9a54bd98114c40774127a2f","solicitation_number":"A070764SS"}]}],"latest_notice_id":"0cf9b5fda9a54bd98114c40774127a2f","first_type":"r","notices":[{"dates":{"posted":"2026-10-14","posted_at":"2026-10-14T15:06:18.533Z","created_at":"2026-10-14T14:37:31.824Z","modified_at":"2026-10-14T15:06:18.536Z","response_deadline":{"raw":"2026-10-26T12:00:00-05:00","utc":"2026-10-26T17:00:00Z","date":"2026-10-26","time":"12:00:00","timezone":"America/Chicago","utc_offset_seconds":-18000}},"links":{"sam":"https://sam.gov/workspace/contract/opp/0cf9b5fda9a54bd98114c40774127a2f/view"},"naics":{"codes":["238220"],"primary":"238220"},"title":"Brand Name or Equal - WaterFurnace Model: UBH015R for B3631 & B3635 - Turnkey Replacement","agency":{"office":{"code":"FA3016","name":"FA3016 502 CONS CL"},"subtier":{"code":"5700","name":"DEPT OF THE AIR FORCE"},"department":{"code":"057","name":"DEPT OF DEFENSE"},"office_address":{"zip":"78236-5286","city":"JBSA LACKLAND","state":"TX","country":"USA"},"organization_id":"500034248","organization_type":"OFFICE"},"status":{"active":true,"latest":true,"deleted":false,"archived":false,"cancelled":false,"publication":"published","archive_date":"2026-11-10","archive_type":"auto15"},"history":[{"index":1,"title":"Brand Name or Equal - WaterFurnace Model: UBH015R for B3631 & B3635 - Turnkey Replacement","action":"publish","latest":true,"deleted":false,"archived":false,"cancelled":false,"posted_at":"2026-10-14T15:06:18.533Z","notice_type":{"code":"r","label":"Sources Sought"},"request_type":"submit","opportunity_id":"0cf9b5fda9a54bd98114c40774127a2f","solicitation_number":"A070764SS"}],"contacts":[{"name":"Teresa Sullivan","role":"primary","email":"teresa.sullivan.4@us.af.mil"},{"name":"Lauren Macias","role":"secondary","email":"lauren.macias.1@us.af.mil"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"0cf9b5fda9a54bd98114c40774127a2f","lineage_id":"0cf9b5fda9a54bd98114c40774127a2f","provenance":{"detail":{"endpoints":["opportunity","resources","history"],"fetched_at":"2026-10-15T04:42:37.223666479Z"},"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/datagov/ContractOpportunitiesFullCSV.csv","etag":"\"613291efb3a44e314e8df73c3d1f2743-25\"","fetched_at":"2026-10-15T04:24:39.658629845Z","row_sha256":"c6e0235af0655f8ae2bf9e1d1d12a3e81bae3823e16b3faecb7f5fabbf937852","last_modified":"2026-10-15T03:30:31Z"},"updated_at":"2026-10-15T04:42:37.223666479Z","first_seen_at":"2026-10-15T04:24:39.658629845Z"},"description":{"html":"<p>The 502d Contracting Squadron (502CONS), on behalf of the 502d Civil Engineer Squadron (502CES), is conducting market research to determine:</p>\n\n<ul>\n\t<li>The availability and technical capability of industry sources (small and large businesses) to furnish and install 48 each 1.25-ton Dedicated Outside Air System (DOAS) Water-Source Heat Pumps (WSHP) which meet strict salient dimensions and environmental characteristics.</li>\n\t<li>The appropriate competitive acquisition strategy, including small business socio-economic set-aside determinations (RFO Part 19 <em>Small Business</em> - Rule of Two).</li>\n\t<li>Standard commercial practices, lead times, supply chain constraints, warranty terms, and pricing structures IAW RFO 10.002(b) <em>Market Research</em>.</li>\n</ul>\n\n<p>The contractor shall provide all personnel, management, equipment, tools, rigging, materials, and supervision necessary to execute the turnkey removal and replacement of 48 ceiling-suspended DOAS WSHP installed above exterior breezeway ceilings in B3631 and B3635 at JBSA Ft Sam Houston (FSH) San Antonio Military Medical Center (SAMMC) Dormitory Annex. This new requirement is projected to be a Firm-Fixed Priced (FFP) Purchase Order as a Commodity (Procurement) with incidental Services (Removal and Installation) buy.</p>\n\n<p>Key Salient Characteristics:</p>\n\n<ul>\n\t<li>Capacity: 1.25 Tons (15,000 BTUH nominal), airflow of 160 L/s (~340 CFM) at 50 Pa ESP.</li>\n\t<li>Configuration: Horizontal, ceiling-plenum suspended, right-hand return air arrangement.</li>\n\t<li>Access Dimension Constraint: Existing units are installed above metal panel breezeway ceilings accessible through structural door openings measuring approximately&nbsp; and replacement units must physically fit through these envelope openings without requiring structural building demolition.</li>\n\t<li>Refrigerant: Low-GWP refrigerant (e.g., R-454B or R-32). R-410A is strictly prohibited.</li>\n\t<li>Hydronic Pre-Heat Coil &amp; Reheat: Integral 3.75 kW water-source pre-heat coil (3-way, 2-position control valve) and factory hot gas reheat (HGRH) / hot gas bypass (HGBP) for 100% outside air continuous dehumidification.</li>\n\t<li>Controls Integration: Complete integration into the installation&#39;s central Building Automation System (BAS via BACnet IP/MSTP).</li>\n</ul>","text":"The 502d Contracting Squadron (502CONS), on behalf of the 502d Civil Engineer Squadron (502CES), is conducting market research to determine:\n\n• The availability and technical capability of industry sources (small and large businesses) to furnish and install 48 each 1.25-ton Dedicated Outside Air System (DOAS) Water-Source Heat Pumps (WSHP) which meet strict salient dimensions and environmental characteristics.\n\n• The appropriate competitive acquisition strategy, including small business socio-economic set-aside determinations (RFO Part 19 Small Business - Rule of Two).\n\n• Standard commercial practices, lead times, supply chain constraints, warranty terms, and pricing structures IAW RFO 10.002(b) Market Research.\n\nThe contractor shall provide all personnel, management, equipment, tools, rigging, materials, and supervision necessary to execute the turnkey removal and replacement of 48 ceiling-suspended DOAS WSHP installed above exterior breezeway ceilings in B3631 and B3635 at JBSA Ft Sam Houston (FSH) San Antonio Military Medical Center (SAMMC) Dormitory Annex. This new requirement is projected to be a Firm-Fixed Priced (FFP) Purchase Order as a Commodity (Procurement) with incidental Services (Removal and Installation) buy.\n\nKey Salient Characteristics:\n\n• Capacity: 1.25 Tons (15,000 BTUH nominal), airflow of 160 L/s (~340 CFM) at 50 Pa ESP.\n\n• Configuration: Horizontal, ceiling-plenum suspended, right-hand return air arrangement.\n\n• Access Dimension Constraint: Existing units are installed above metal panel breezeway ceilings accessible through structural door openings measuring approximately and replacement units must physically fit through these envelope openings without requiring structural building demolition.\n\n• Refrigerant: Low-GWP refrigerant (e.g., R-454B or R-32). R-410A is strictly prohibited.\n\n• Hydronic Pre-Heat Coil & Reheat: Integral 3.75 kW water-source pre-heat coil (3-way, 2-position control valve) and factory hot gas reheat (HGRH) / hot gas bypass (HGBP) for 100% outside air continuous dehumidification.\n\n• Controls Integration: Complete integration into the installation's central Building Automation System (BAS via BACnet IP/MSTP).","origin":"detail"},"notice_type":{"code":"r","label":"Sources Sought"},"schema_version":1,"solicitation_number":"A070764SS","place_of_performance":{"zip":"78234","city":{"code":"0","name":"JBSA Ft Sam Houston"},"state":{"code":"TX","name":"Texas"},"country":{"code":"USA","name":"UNITED STATES"}},"product_service_code":"4120"}],"due_at":"2026-10-26T17:00:00Z","due_date":"2026-10-26","closes_at":"2026-10-26T17:00:00Z","awardable":true,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA3016","office_name":"FA3016 502 CONS CL","state":"TX","county":"48029","county_name":"Bexar County","city":null,"city_name":null,"country":"USA","state_source":null,"state_evidence":null,"site_key":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-10-15T04:27:28.954735Z","principal_notice_id":"0cf9b5fda9a54bd98114c40774127a2f","description":{"text":"The 502d Contracting Squadron (502CONS), on behalf of the 502d Civil Engineer Squadron (502CES), is conducting market research to determine:\n\n• The availability and technical capability of industry sources (small and large businesses) to furnish and install 48 each 1.25-ton Dedicated Outside Air System (DOAS) Water-Source Heat Pumps (WSHP) which meet strict salient dimensions and environmental characteristics.\n\n• The appropriate competitive acquisition strategy, including small business socio-economic set-aside determinations (RFO Part 19 Small Business - Rule of Two).\n\n• Standard commercial practices, lead times, supply chain constraints, warranty terms, and pricing structures IAW RFO 10.002(b) Market Research.\n\nThe contractor shall provide all personnel, management, equipment, tools, rigging, materials, and supervision necessary to execute the turnkey removal and replacement of 48 ceiling-suspended DOAS WSHP installed above exterior breezeway ceilings in B3631 and B3635 at JBSA Ft Sam Houston (FSH) San Antonio Military Medical Center (SAMMC) Dormitory Annex. This new requirement is projected to be a Firm-Fixed Priced (FFP) Purchase Order as a Commodity (Procurement) with incidental Services (Removal and Installation) buy.\n\nKey Salient Characteristics:\n\n• Capacity: 1.25 Tons (15,000 BTUH nominal), airflow of 160 L/s (~340 CFM) at 50 Pa ESP.\n\n• Configuration: Horizontal, ceiling-plenum suspended, right-hand return air arrangement.\n\n• Access Dimension Constraint: Existing units are installed above metal panel breezeway ceilings accessible through structural door openings measuring approximately and replacement units must physically fit through these envelope openings without requiring structural building demolition.\n\n• Refrigerant: Low-GWP refrigerant (e.g., R-454B or R-32). R-410A is strictly prohibited.\n\n• Hydronic Pre-Heat Coil & Reheat: Integral 3.75 kW water-source pre-heat coil (3-way, 2-position control valve) and factory hot gas reheat (HGRH) / hot gas bypass (HGBP) for 100% outside air continuous dehumidification.\n\n• Controls Integration: Complete integration into the installation's central Building Automation System (BAS via BACnet IP/MSTP).","html":"<p>The 502d Contracting Squadron (502CONS), on behalf of the 502d Civil Engineer Squadron (502CES), is conducting market research to determine:</p>\n\n<ul>\n\t<li>The availability and technical capability of industry sources (small and large businesses) to furnish and install 48 each 1.25-ton Dedicated Outside Air System (DOAS) Water-Source Heat Pumps (WSHP) which meet strict salient dimensions and environmental characteristics.</li>\n\t<li>The appropriate competitive acquisition strategy, including small business socio-economic set-aside determinations (RFO Part 19 <em>Small Business</em> - Rule of Two).</li>\n\t<li>Standard commercial practices, lead times, supply chain constraints, warranty terms, and pricing structures IAW RFO 10.002(b) <em>Market Research</em>.</li>\n</ul>\n\n<p>The contractor shall provide all personnel, management, equipment, tools, rigging, materials, and supervision necessary to execute the turnkey removal and replacement of 48 ceiling-suspended DOAS WSHP installed above exterior breezeway ceilings in B3631 and B3635 at JBSA Ft Sam Houston (FSH) San Antonio Military Medical Center (SAMMC) Dormitory Annex. This new requirement is projected to be a Firm-Fixed Priced (FFP) Purchase Order as a Commodity (Procurement) with incidental Services (Removal and Installation) buy.</p>\n\n<p>Key Salient Characteristics:</p>\n\n<ul>\n\t<li>Capacity: 1.25 Tons (15,000 BTUH nominal), airflow of 160 L/s (~340 CFM) at 50 Pa ESP.</li>\n\t<li>Configuration: Horizontal, ceiling-plenum suspended, right-hand return air arrangement.</li>\n\t<li>Access Dimension Constraint: Existing units are installed above metal panel breezeway ceilings accessible through structural door openings measuring approximately&nbsp; and replacement units must physically fit through these envelope openings without requiring structural building demolition.</li>\n\t<li>Refrigerant: Low-GWP refrigerant (e.g., R-454B or R-32). R-410A is strictly prohibited.</li>\n\t<li>Hydronic Pre-Heat Coil &amp; Reheat: Integral 3.75 kW water-source pre-heat coil (3-way, 2-position control valve) and factory hot gas reheat (HGRH) / hot gas bypass (HGBP) for 100% outside air continuous dehumidification.</li>\n\t<li>Controls Integration: Complete integration into the installation&#39;s central Building Automation System (BAS via BACnet IP/MSTP).</li>\n</ul>","origin":"detail"},"contacts":[{"name":"Teresa Sullivan","role":"primary","email":"teresa.sullivan.4@us.af.mil"},{"name":"Lauren Macias","role":"secondary","email":"lauren.macias.1@us.af.mil"}],"place_of_performance":{"zip":"78234","city":{"code":"0","name":"JBSA Ft Sam Houston"},"state":{"code":"TX","name":"Texas"},"country":{"code":"USA","name":"UNITED STATES"}},"office_address":{"zip":"78236-5286","city":"JBSA LACKLAND","state":"TX","country":"USA"},"naics_codes":["238220"],"award":null,"attachments":[{"resource_id":"a4eb5181b01b42fba1bc41e34eabf3c0","name":"Sources Sought - JBSA FSH (B3631.B3635) Replacement DOAS WSHP.pdf","kind":"file","mime_type":".pdf","size_bytes":272447,"posted_at":"2026-10-14T15:06:18.533Z","export_controlled":false,"sha256":null,"url":"https://sam.gov/api/prod/opps/v3/opportunities/resources/files/a4eb5181b01b42fba1bc41e34eabf3c0/download","mirrored":false}],"awards":[],"related":[{"key":"FA301627Q0011","latest_notice_id":"4dcb2adf3ae1422185906f331f7d143e","title":"Cubicle Installation","solicitation_number":"FA301627Q0011","notice_type":"r","first_type":"r","first_posted":"2026-10-28","last_posted":"2026-10-28","notices":1,"due_at":"2026-11-03T16:00:00Z","due_date":"2026-11-03","closes_at":"2026-11-03T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA3016","office_name":"FA3016 502 CONS CL","naics":"337214","psc":"N071","set_aside":"SBA","state":"TX","county":"48029","county_name":"Bexar County","city":null,"city_name":null,"country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-29T04:15:54.363094Z"},{"key":"A070977","latest_notice_id":"f7980d46f11a424c869fdf6609890e8f","title":"DCF3 PROJECTION SYSTEM","solicitation_number":"A070977","notice_type":"r","first_type":"r","first_posted":"2026-10-19","last_posted":"2026-10-29","notices":5,"due_at":"2026-11-04T18:00:00Z","due_date":"2026-11-04","closes_at":"2026-11-04T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA3016","office_name":"FA3016 502 CONS CL","naics":null,"psc":null,"set_aside":null,"state":"TX","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"sam_street","state_evidence":"1209 LUKE AVE, BLDG. 9270JBSA-LACKLAND, TX 78236","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-30T03:41:17.879115Z"},{"key":"A070819","latest_notice_id":"a5830950367840568c031809073f5268","title":"Sources Sought - Methicillin-Resistant Staphylococcus Aureus (MRSA) Sanitation Services","solicitation_number":"A070819","notice_type":"r","first_type":"r","first_posted":"2026-10-26","last_posted":"2026-10-26","notices":1,"due_at":"2026-11-06T22:00:00Z","due_date":"2026-11-06","closes_at":"2026-11-06T22:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA3016","office_name":"FA3016 502 CONS CL","naics":"561720","psc":"S201","set_aside":"SBA","state":"TX","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"sam_street","state_evidence":"JBSA LACKLAND AND CHAPMAN TRAINING ANNEX, SAN ANTONIO, TX","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-27T03:50:29.852134Z"},{"key":"FA301627Q0010","latest_notice_id":"efa2f7421c97493c8c085fca727a9867","title":"50 - TON AC SMART RENTAL FOR BUILDING 1062 JOINT BASE SAN ANTONIO (JBSA) FORT SAM HOUSTON (FSH), TX","solicitation_number":"FA301627Q0010","notice_type":"o","first_type":"o","first_posted":"2026-10-29","last_posted":"2026-10-29","notices":2,"due_at":"2026-11-10T16:00:00Z","due_date":"2026-11-10","closes_at":"2026-11-10T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA3016","office_name":"FA3016 502 CONS CL","naics":"532490","psc":"4120","set_aside":"SBA","state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"nationwide","state_source":null,"state_evidence":"Product purchase (PSC 4120)","site":"Joint Base San Antonio","site_key":"joint-base-san-antonio-tx","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-30T03:41:17.879115Z"},{"key":"FA301627Q0008","latest_notice_id":"053d8d38987b4ae1947c31be77678744","title":"JBSA Lodging Revised Solicitation","solicitation_number":"FA301627Q0008","notice_type":"k","first_type":"k","first_posted":"2026-10-21","last_posted":"2026-10-21","notices":1,"due_at":"2026-11-10T18:00:00Z","due_date":"2026-11-10","closes_at":"2026-11-10T18:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-057","dept_name":"DEPT OF DEFENSE","sub_key":"s-5700","sub_name":"DEPT OF THE AIR FORCE","office_key":"o-FA3016","office_name":"FA3016 502 CONS CL","naics":"721110","psc":"V231","set_aside":"SBA","state":"TX","county":null,"county_name":null,"city":null,"city_name":null,"country":null,"place_scope":"site","state_source":"site","state_evidence":"SOLICITATION NOTICE: JOINT BASE SAN ANTONIO","site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-22T04:09:15.685315Z"}],"similar_open":[{"key":"36C25727Q0033","latest_notice_id":"b2aba5e286454e13b93d895038712a01","title":"CANCELLATION - NTX Steam Trap Monitoring - CANCELLATION","solicitation_number":"36C25727Q0033","notice_type":"o","first_type":"o","first_posted":"2026-10-05","last_posted":"2026-10-29","notices":2,"due_at":"2026-11-04T16:00:00Z","due_date":"2026-11-04","closes_at":"2026-11-04T16:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C257","office_name":"257-NETWORK CONTRACT OFFICE 17 (36C257)","naics":"238220","psc":"J045","set_aside":"SDVOSBC","state":"TX","county":"48113","county_name":"Dallas County","city":"4819000","city_name":"Dallas","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-30T03:41:17.879115Z"},{"key":"36C25727Q0078","latest_notice_id":"616b66e8af494e9ba365bdbb907a9176","title":"J048--NEW - Energy Center Steam Header& Boilers valves, gaskets, and vent replacement","solicitation_number":"36C25727Q0078","notice_type":"r","first_type":"r","first_posted":"2026-10-30","last_posted":"2026-10-30","notices":1,"due_at":"2026-11-09T20:00:00Z","due_date":"2026-11-09","closes_at":"2026-11-09T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C257","office_name":"257-NETWORK CONTRACT OFFICE 17 (36C257)","naics":"238220","psc":"J048","set_aside":"SDVOSBC","state":"TX","county":"48113","county_name":"Dallas County","city":"4819000","city_name":"Dallas","country":null,"place_scope":"site","state_source":"sam_state_name","state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-31T06:25:05.449281Z"},{"key":"36C25626R0130","latest_notice_id":"ae234db09f8948909d14474346f3dbb6","title":"CON | Z1DA | REPLACE OR CHILLERS | 580-23-105 | SOLICITATION","solicitation_number":"36C25626R0130","notice_type":"o","first_type":"p","first_posted":"2026-09-29","last_posted":"2026-10-29","notices":4,"due_at":"2026-12-02T20:00:00Z","due_date":"2026-12-02","closes_at":"2026-12-02T20:00:00Z","awardable":true,"open":true,"removed":false,"dept_key":"d-036","dept_name":"VETERANS AFFAIRS, DEPARTMENT OF","sub_key":"s-3600","sub_name":"VETERANS AFFAIRS, DEPARTMENT OF","office_key":"o-36C256","office_name":"256-NETWORK CONTRACT OFFICE 16 (36C256)","naics":"238220","psc":"Z1DA","set_aside":"SDVOSBC","state":"TX","county":"48201","county_name":"Harris County","city":"4835000","city_name":"Houston","country":"USA","place_scope":"site","state_source":null,"state_evidence":null,"site":null,"site_key":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"removed_at":null,"updated_at":"2026-10-30T03:41:17.879115Z"}],"similar_open_total":44}