{"canonical":"https://abierto.us/opportunities/80ksc025r0009","key":"80KSC025R0009","url":"https://abierto.us/opportunities/80ksc025r0009","title":"Vehicle Assembly Building (VAB) Power Phase I (Tower C), Project Control Number (PCN): 99300","solicitation_number":"80KSC025R0009","notice_type":"o","open":false,"response_deadline":"2025-09-08T18:00:00Z","first_posted":"2025-07-17","last_posted":"2025-09-04","department":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION","subagency":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION","office":"NASA KENNEDY SPACE CENTER","naics":"237130","psc":"Y1BG","set_aside":"SBA","place_state":"FL","place_county":"12009","place_county_name":"Brevard County","place_city":null,"place_city_name":null,"winner":"A. WEST ENTERPRISE, LLC","award_amount":null,"publications":[{"notice_id":"0d9fa8887ddf430b9d02237aab799cbb","title":"Vehicle Assembly Building (VAB) Power Phase I (Tower C), Project Control Number (PCN): 99300","solicitation_number":"80KSC025R0009","notice_type":"p","base_type":"r","posted":"2025-07-17","posted_at":null,"due_at":"2025-08-01T18:00:00Z","due_date":"2025-08-01","cancelled":null,"archived":null,"archive_date":"2025-08-16","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/0d9fa8887ddf430b9d02237aab799cbb/view","enriched":false,"history":[]},{"notice_id":"4040e0c0930e4fa8831028023f3dbd7b","title":"Vehicle Assembly Building (VAB) Power Phase I (Tower C), Project Control Number (PCN): 99300","solicitation_number":"80KSC025R0009","notice_type":"o","base_type":"p","posted":"2025-08-07","posted_at":null,"due_at":"2025-09-08T18:00:00Z","due_date":"2025-09-08","cancelled":null,"archived":null,"archive_date":"2025-09-23","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/4040e0c0930e4fa8831028023f3dbd7b/view","enriched":false,"history":[]},{"notice_id":"700766ba5a7f47a2a4a1caebaff44e75","title":"Vehicle Assembly Building (VAB) Power Phase I (Tower C), Project Control Number (PCN): 99300","solicitation_number":"80KSC025R0009","notice_type":"o","base_type":"o","posted":"2025-08-07","posted_at":null,"due_at":"2025-09-08T18:00:00Z","due_date":"2025-09-08","cancelled":null,"archived":null,"archive_date":"2025-09-23","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/700766ba5a7f47a2a4a1caebaff44e75/view","enriched":false,"history":[]},{"notice_id":"ba607206dd5d4b9092d409b4aa59ebd0","title":"Vehicle Assembly Building (VAB) Power Phase I (Tower C), Project Control Number (PCN): 99300","solicitation_number":"80KSC025R0009","notice_type":"o","base_type":"o","posted":"2025-08-15","posted_at":null,"due_at":"2025-09-08T18:00:00Z","due_date":"2025-09-08","cancelled":null,"archived":null,"archive_date":"2025-09-23","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/ba607206dd5d4b9092d409b4aa59ebd0/view","enriched":false,"history":[]},{"notice_id":"2af90899f2b54a13aa1e56e715cf4737","title":"Vehicle Assembly Building (VAB) Power Phase I (Tower C), Project Control Number (PCN): 99300","solicitation_number":"80KSC025R0009","notice_type":"o","base_type":"o","posted":"2025-08-20","posted_at":null,"due_at":"2025-09-08T18:00:00Z","due_date":"2025-09-08","cancelled":null,"archived":null,"archive_date":"2025-09-23","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/2af90899f2b54a13aa1e56e715cf4737/view","enriched":false,"history":[]},{"notice_id":"df8083f7423149d5852851ffa4cf17e0","title":"Vehicle Assembly Building (VAB) Power Phase I (Tower C), Project Control Number (PCN): 99300","solicitation_number":"80KSC025R0009","notice_type":"o","base_type":"o","posted":"2025-08-29","posted_at":null,"due_at":"2025-09-08T18:00:00Z","due_date":"2025-09-08","cancelled":null,"archived":null,"archive_date":"2025-09-23","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/df8083f7423149d5852851ffa4cf17e0/view","enriched":false,"history":[]},{"notice_id":"5598f8f7b87041e899a0821b4c6db445","title":"Vehicle Assembly Building (VAB) Power Phase I (Tower C), Project Control Number (PCN): 99300","solicitation_number":"80KSC025R0009","notice_type":"o","base_type":"o","posted":"2025-09-02","posted_at":null,"due_at":"2025-09-08T18:00:00Z","due_date":"2025-09-08","cancelled":null,"archived":null,"archive_date":"2025-09-23","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/5598f8f7b87041e899a0821b4c6db445/view","enriched":false,"history":[]},{"notice_id":"a71179a349274fc0af3001d699a2c886","title":"Vehicle Assembly Building (VAB) Power Phase I (Tower C), Project Control Number (PCN): 99300","solicitation_number":"80KSC025R0009","notice_type":"o","base_type":"o","posted":"2025-09-03","posted_at":null,"due_at":"2025-09-08T18:00:00Z","due_date":"2025-09-08","cancelled":null,"archived":null,"archive_date":"2025-09-23","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/a71179a349274fc0af3001d699a2c886/view","enriched":false,"history":[]},{"notice_id":"f2cd90ac28ca4b079ce81575a0dfdec5","title":"Vehicle Assembly Building (VAB) Power Phase I (Tower C), Project Control Number (PCN): 99300","solicitation_number":"80KSC025R0009","notice_type":"o","base_type":"o","posted":"2025-09-03","posted_at":null,"due_at":"2025-09-08T18:00:00Z","due_date":"2025-09-08","cancelled":null,"archived":null,"archive_date":"2025-09-23","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/f2cd90ac28ca4b079ce81575a0dfdec5/view","enriched":false,"history":[]},{"notice_id":"6a93abd024f5457c85e027145c20745b","title":"Vehicle Assembly Building (VAB) Power Phase I (Tower C), Project Control Number (PCN): 99300","solicitation_number":"80KSC025R0009","notice_type":"o","base_type":"o","posted":"2025-09-04","posted_at":null,"due_at":"2025-09-08T18:00:00Z","due_date":"2025-09-08","cancelled":null,"archived":null,"archive_date":"2025-09-23","award_number":null,"awardee_name":null,"amount":null,"link_sam":"https://sam.gov/workspace/contract/opp/6a93abd024f5457c85e027145c20745b/view","enriched":false,"history":[]}],"latest_notice_id":"6a93abd024f5457c85e027145c20745b","first_type":"p","notices":[{"dates":{"posted":"2025-07-17","response_deadline":{"raw":"2025-08-01T14:00:00-04:00","utc":"2025-08-01T18:00:00Z","date":"2025-08-01","time":"14:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/0d9fa8887ddf430b9d02237aab799cbb/view"},"naics":{"codes":["237130"],"primary":"237130"},"title":"Vehicle Assembly Building (VAB) Power Phase I (Tower C), Project Control Number (PCN): 99300","agency":{"office":{"code":"80KSC0","name":"NASA KENNEDY SPACE CENTER"},"subtier":{"code":"8000","name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION"},"department":{"code":"080","name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION"},"office_address":{"zip":"32899","city":"KENNEDY SPACE CENTER","state":"FL","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2025-08-16","archive_type":"auto15"},"contacts":[{"name":"LaCorsha Noel","role":"primary","email":"Lacorsha.d.noel@nasa.gov","phone":"3218673464"},{"name":"Stephen Crooks","role":"secondary","email":"Stephen.e.crooks@nasa.gov","phone":"3218671583"}],"base_type":{"code":"r","label":"Sources Sought"},"notice_id":"0d9fa8887ddf430b9d02237aab799cbb","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"2256a8c5296deee57aaf294ff4bd1e596711e73b4fa9734fa471f31f1e3ca672","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-09-16T17:45:50.850439Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"text":"NASA/John F. Kennedy Space Center plans to issue a Request for Proposal (RFP) for 80KSC025R009, Revitalize Power Systems at the VAB Tower C, John F. Kennedy Space Center, Florida. The North American Industry Classification System (NAICS) code for this procurement is 237130, Power and communication Line and Related Structures Construction with a size standard of $45,000,000. The objective of this project is to replace the obsolete substations and associated equipment which will significantly increase the safety of the facility and maintenance personnel. Additionally, the new substations will increase the availability and reliability of the VAB Tower C power system. This project consists of replacing existing VAB Tower C substations 804, 874 (10th floor) and 875 (32nd floor) and all associated 480V sub-fed panels located inside Tower C at the VAB with new reliable code compliant electrical substations and associated downstream equipment. Additionally, a new Arc Flash study will be performed as a part of this project. This is a 100% Small Business Set-Aside procurement. Estimated solicitation release date for this requirement is August 2025, with a project period of performance of approximately 800 calendar days. Estimated award amount is anticipated between $5,000,000 and $10,000,000.","origin":"extract"},"notice_type":{"code":"p","label":"Presolicitation"},"schema_version":1,"solicitation_number":"80KSC025R0009","place_of_performance":{"zip":"32899","state":{"code":"FL"},"country":{"code":"USA"}},"product_service_code":"Y1BG"},{"dates":{"posted":"2025-08-07","response_deadline":{"raw":"2025-09-08T14:00:00-04:00","utc":"2025-09-08T18:00:00Z","date":"2025-09-08","time":"14:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/4040e0c0930e4fa8831028023f3dbd7b/view"},"naics":{"codes":["237130"],"primary":"237130"},"title":"Vehicle Assembly Building (VAB) Power Phase I (Tower C), Project Control Number (PCN): 99300","agency":{"office":{"code":"80KSC0","name":"NASA KENNEDY SPACE CENTER"},"subtier":{"code":"8000","name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION"},"department":{"code":"080","name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION"},"office_address":{"zip":"32899","city":"KENNEDY SPACE CENTER","state":"FL","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2025-09-23","archive_type":"auto15"},"contacts":[{"name":"LaCorsha Noel","role":"primary","email":"Lacorsha.d.noel@nasa.gov","phone":"3218673464"},{"name":"Stephen Crooks","role":"secondary","email":"Stephen.e.crooks@nasa.gov","phone":"3218671583"}],"base_type":{"code":"p","label":"Presolicitation"},"notice_id":"4040e0c0930e4fa8831028023f3dbd7b","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"05bfdd302cb2a61df54db798ba03e43ffac9601c578ba7eefbc22510b017998e","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-09-16T17:45:50.850439Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"text":"NASA/John F. Kennedy Space Center is issuing a Request for Proposal (RFP) for 80KSC025R009, Revitalize Power Systems at the VAB Tower C, John F. Kennedy Space Center, Florida. The North American Industry Classification System (NAICS) code for this procurement is 237130, Power and communication Line and Related Structures Construction with a size standard of $45,000,000. The objective of this project is to replace the obsolete substations and associated equipment which will significantly increase the safety of the facility and maintenance personnel. Additionally, the new substations will increase the availability and reliability of the VAB Tower C power system. This project consists of replacing existing VAB Tower C substations 804, 874 (10th floor) and 875 (32nd floor) and all associated 480V sub-fed panels located inside Tower C at the VAB with new reliable code compliant electrical substations and associated downstream equipment. Additionally, a new Arc Flash study will be performed as a part of this project. This is a 100% Small Business Set-Aside procurement. The project period of performance is 800 calendar days. Estimated award amount is anticipated between $5,000,000 and $10,000,000.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"80KSC025R0009","place_of_performance":{"zip":"32899","state":{"code":"FL"},"country":{"code":"USA"}},"product_service_code":"Y1BG"},{"dates":{"posted":"2025-08-07","response_deadline":{"raw":"2025-09-08T14:00:00-04:00","utc":"2025-09-08T18:00:00Z","date":"2025-09-08","time":"14:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/700766ba5a7f47a2a4a1caebaff44e75/view"},"naics":{"codes":["237130"],"primary":"237130"},"title":"Vehicle Assembly Building (VAB) Power Phase I (Tower C), Project Control Number (PCN): 99300","agency":{"office":{"code":"80KSC0","name":"NASA KENNEDY SPACE CENTER"},"subtier":{"code":"8000","name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION"},"department":{"code":"080","name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION"},"office_address":{"zip":"32899","city":"KENNEDY SPACE CENTER","state":"FL","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2025-09-23","archive_type":"auto15"},"contacts":[{"name":"LaCorsha Noel","role":"primary","email":"Lacorsha.d.noel@nasa.gov","phone":"3218673464"},{"name":"Stephen Crooks","role":"secondary","email":"Stephen.e.crooks@nasa.gov","phone":"3218671583"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"700766ba5a7f47a2a4a1caebaff44e75","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"04e341dbc035b3e49598356e4435af17fdc80126c1965c7bbf8836f8a02f35bf","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-09-16T17:45:50.850439Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"text":"NASA/John F. Kennedy Space Center is issuing a Request for Proposal (RFP) for 80KSC025R009, Revitalize Power Systems at the VAB Tower C, John F. Kennedy Space Center, Florida. The North American Industry Classification System (NAICS) code for this procurement is 237130, Power and communication Line and Related Structures Construction with a size standard of $45,000,000. The objective of this project is to replace the obsolete substations and associated equipment which will significantly increase the safety of the facility and maintenance personnel. Additionally, the new substations will increase the availability and reliability of the VAB Tower C power system. This project consists of replacing existing VAB Tower C substations 804, 874 (10th floor) and 875 (32nd floor) and all associated 480V sub-fed panels located inside Tower C at the VAB with new reliable code compliant electrical substations and associated downstream equipment. Additionally, a new Arc Flash study will be performed as a part of this project. This is a 100% Small Business Set-Aside procurement. The project period of performance is 800 calendar days. Estimated award amount is anticipated between $5,000,000 and $10,000,000.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"80KSC025R0009","place_of_performance":{"zip":"32899","state":{"code":"FL"},"country":{"code":"USA"}},"product_service_code":"Y1BG"},{"dates":{"posted":"2025-08-15","response_deadline":{"raw":"2025-09-08T14:00:00-04:00","utc":"2025-09-08T18:00:00Z","date":"2025-09-08","time":"14:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/ba607206dd5d4b9092d409b4aa59ebd0/view"},"naics":{"codes":["237130"],"primary":"237130"},"title":"Vehicle Assembly Building (VAB) Power Phase I (Tower C), Project Control Number (PCN): 99300","agency":{"office":{"code":"80KSC0","name":"NASA KENNEDY SPACE CENTER"},"subtier":{"code":"8000","name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION"},"department":{"code":"080","name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION"},"office_address":{"zip":"32899","city":"KENNEDY SPACE CENTER","state":"FL","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2025-09-23","archive_type":"auto15"},"contacts":[{"name":"LaCorsha Noel","role":"primary","email":"Lacorsha.d.noel@nasa.gov","phone":"3218673464"},{"name":"Stephen Crooks","role":"secondary","email":"Stephen.e.crooks@nasa.gov","phone":"3218671583"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"ba607206dd5d4b9092d409b4aa59ebd0","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"af869ae9de7af605abcb7f0a5eb7df06db919c771bb465b9f6f5606bab5bd421","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-09-16T17:45:50.850439Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"text":"NASA/John F. Kennedy Space Center is issuing a Request for Proposal (RFP) for 80KSC025R009, Revitalize Power Systems at the VAB Tower C, John F. Kennedy Space Center, Florida. The North American Industry Classification System (NAICS) code for this procurement is 237130, Power and communication Line and Related Structures Construction with a size standard of $45,000,000. The objective of this project is to replace the obsolete substations and associated equipment which will significantly increase the safety of the facility and maintenance personnel. Additionally, the new substations will increase the availability and reliability of the VAB Tower C power system. This project consists of replacing existing VAB Tower C substations 804, 874 (10th floor) and 875 (32nd floor) and all associated 480V sub-fed panels located inside Tower C at the VAB with new reliable code compliant electrical substations and associated downstream equipment. Additionally, a new Arc Flash study will be performed as a part of this project. This is a 100% Small Business Set-Aside procurement. The project period of performance is 800 calendar days. Estimated award amount is anticipated between $5,000,000 and $10,000,000.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"80KSC025R0009","place_of_performance":{"zip":"32899","state":{"code":"FL"},"country":{"code":"USA"}},"product_service_code":"Y1BG"},{"dates":{"posted":"2025-08-20","response_deadline":{"raw":"2025-09-08T14:00:00-04:00","utc":"2025-09-08T18:00:00Z","date":"2025-09-08","time":"14:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/2af90899f2b54a13aa1e56e715cf4737/view"},"naics":{"codes":["237130"],"primary":"237130"},"title":"Vehicle Assembly Building (VAB) Power Phase I (Tower C), Project Control Number (PCN): 99300","agency":{"office":{"code":"80KSC0","name":"NASA KENNEDY SPACE CENTER"},"subtier":{"code":"8000","name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION"},"department":{"code":"080","name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION"},"office_address":{"zip":"32899","city":"KENNEDY SPACE CENTER","state":"FL","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2025-09-23","archive_type":"auto15"},"contacts":[{"name":"LaCorsha Noel","role":"primary","email":"Lacorsha.d.noel@nasa.gov","phone":"3218673464"},{"name":"Stephen Crooks","role":"secondary","email":"Stephen.e.crooks@nasa.gov","phone":"3218671583"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"2af90899f2b54a13aa1e56e715cf4737","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"d6f8a53a9a6523b4eae25226da735cd23d2e8b392a9713cd3267dce2a2903f87","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-09-16T17:45:50.850439Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"text":"NASA/John F. Kennedy Space Center is issuing a Request for Proposal (RFP) for 80KSC025R009, Revitalize Power Systems at the VAB Tower C, John F. Kennedy Space Center, Florida. The North American Industry Classification System (NAICS) code for this procurement is 237130, Power and communication Line and Related Structures Construction with a size standard of $45,000,000. The objective of this project is to replace the obsolete substations and associated equipment which will significantly increase the safety of the facility and maintenance personnel. Additionally, the new substations will increase the availability and reliability of the VAB Tower C power system. This project consists of replacing existing VAB Tower C substations 804, 874 (10th floor) and 875 (32nd floor) and all associated 480V sub-fed panels located inside Tower C at the VAB with new reliable code compliant electrical substations and associated downstream equipment. Additionally, a new Arc Flash study will be performed as a part of this project. This is a 100% Small Business Set-Aside procurement. The project period of performance is 800 calendar days. Estimated award amount is anticipated between $5,000,000 and $10,000,000.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"80KSC025R0009","place_of_performance":{"zip":"32899","state":{"code":"FL"},"country":{"code":"USA"}},"product_service_code":"Y1BG"},{"dates":{"posted":"2025-08-29","response_deadline":{"raw":"2025-09-08T14:00:00-04:00","utc":"2025-09-08T18:00:00Z","date":"2025-09-08","time":"14:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/df8083f7423149d5852851ffa4cf17e0/view"},"naics":{"codes":["237130"],"primary":"237130"},"title":"Vehicle Assembly Building (VAB) Power Phase I (Tower C), Project Control Number (PCN): 99300","agency":{"office":{"code":"80KSC0","name":"NASA KENNEDY SPACE CENTER"},"subtier":{"code":"8000","name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION"},"department":{"code":"080","name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION"},"office_address":{"zip":"32899","city":"KENNEDY SPACE CENTER","state":"FL","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2025-09-23","archive_type":"auto15"},"contacts":[{"name":"LaCorsha Noel","role":"primary","email":"Lacorsha.d.noel@nasa.gov","phone":"3218673464"},{"name":"Stephen Crooks","role":"secondary","email":"Stephen.e.crooks@nasa.gov","phone":"3218671583"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"df8083f7423149d5852851ffa4cf17e0","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"80ceed6b51151580a0df8018ff3d8a8ee82ae928889c8616e07fb3e4e7f13736","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-09-16T17:45:50.850439Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"text":"NASA/John F. Kennedy Space Center is issuing a Request for Proposal (RFP) for 80KSC025R009, Revitalize Power Systems at the VAB Tower C, John F. Kennedy Space Center, Florida. The North American Industry Classification System (NAICS) code for this procurement is 237130, Power and communication Line and Related Structures Construction with a size standard of $45,000,000. The objective of this project is to replace the obsolete substations and associated equipment which will significantly increase the safety of the facility and maintenance personnel. Additionally, the new substations will increase the availability and reliability of the VAB Tower C power system. This project consists of replacing existing VAB Tower C substations 804, 874 (10th floor) and 875 (32nd floor) and all associated 480V sub-fed panels located inside Tower C at the VAB with new reliable code compliant electrical substations and associated downstream equipment. Additionally, a new Arc Flash study will be performed as a part of this project. This is a 100% Small Business Set-Aside procurement. The project period of performance is 800 calendar days. Estimated award amount is anticipated between $5,000,000 and $10,000,000.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"80KSC025R0009","place_of_performance":{"zip":"32899","state":{"code":"FL"},"country":{"code":"USA"}},"product_service_code":"Y1BG"},{"dates":{"posted":"2025-09-02","response_deadline":{"raw":"2025-09-08T14:00:00-04:00","utc":"2025-09-08T18:00:00Z","date":"2025-09-08","time":"14:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/5598f8f7b87041e899a0821b4c6db445/view"},"naics":{"codes":["237130"],"primary":"237130"},"title":"Vehicle Assembly Building (VAB) Power Phase I (Tower C), Project Control Number (PCN): 99300","agency":{"office":{"code":"80KSC0","name":"NASA KENNEDY SPACE CENTER"},"subtier":{"code":"8000","name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION"},"department":{"code":"080","name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION"},"office_address":{"zip":"32899","city":"KENNEDY SPACE CENTER","state":"FL","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2025-09-23","archive_type":"auto15"},"contacts":[{"name":"LaCorsha Noel","role":"primary","email":"Lacorsha.d.noel@nasa.gov","phone":"3218673464"},{"name":"Stephen Crooks","role":"secondary","email":"Stephen.e.crooks@nasa.gov","phone":"3218671583"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"5598f8f7b87041e899a0821b4c6db445","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"8289932d1eb649d7d9582e8cd5d54fd411f7d67e689e56005d3d81ac36989716","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-09-16T17:45:50.850439Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"text":"NASA/John F. Kennedy Space Center is issuing a Request for Proposal (RFP) for 80KSC025R009, Revitalize Power Systems at the VAB Tower C, John F. Kennedy Space Center, Florida. The North American Industry Classification System (NAICS) code for this procurement is 237130, Power and communication Line and Related Structures Construction with a size standard of $45,000,000. The objective of this project is to replace the obsolete substations and associated equipment which will significantly increase the safety of the facility and maintenance personnel. Additionally, the new substations will increase the availability and reliability of the VAB Tower C power system. This project consists of replacing existing VAB Tower C substations 804, 874 (10th floor) and 875 (32nd floor) and all associated 480V sub-fed panels located inside Tower C at the VAB with new reliable code compliant electrical substations and associated downstream equipment. Additionally, a new Arc Flash study will be performed as a part of this project. This is a 100% Small Business Set-Aside procurement. The project period of performance is 800 calendar days. Estimated award amount is anticipated between $5,000,000 and $10,000,000.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"80KSC025R0009","place_of_performance":{"zip":"32899","state":{"code":"FL"},"country":{"code":"USA"}},"product_service_code":"Y1BG"},{"dates":{"posted":"2025-09-03","response_deadline":{"raw":"2025-09-08T14:00:00-04:00","utc":"2025-09-08T18:00:00Z","date":"2025-09-08","time":"14:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/a71179a349274fc0af3001d699a2c886/view"},"naics":{"codes":["237130"],"primary":"237130"},"title":"Vehicle Assembly Building (VAB) Power Phase I (Tower C), Project Control Number (PCN): 99300","agency":{"office":{"code":"80KSC0","name":"NASA KENNEDY SPACE CENTER"},"subtier":{"code":"8000","name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION"},"department":{"code":"080","name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION"},"office_address":{"zip":"32899","city":"KENNEDY SPACE CENTER","state":"FL","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2025-09-23","archive_type":"auto15"},"contacts":[{"name":"LaCorsha Noel","role":"primary","email":"Lacorsha.d.noel@nasa.gov","phone":"3218673464"},{"name":"Stephen Crooks","role":"secondary","email":"Stephen.e.crooks@nasa.gov","phone":"3218671583"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"a71179a349274fc0af3001d699a2c886","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"91e992a624c332ebe8fad9270544623b434e325153331415810500e319bc213d","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-09-16T17:45:50.850439Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"text":"NASA/John F. Kennedy Space Center is issuing a Request for Proposal (RFP) for 80KSC025R009, Revitalize Power Systems at the VAB Tower C, John F. Kennedy Space Center, Florida. The North American Industry Classification System (NAICS) code for this procurement is 237130, Power and communication Line and Related Structures Construction with a size standard of $45,000,000. The objective of this project is to replace the obsolete substations and associated equipment which will significantly increase the safety of the facility and maintenance personnel. Additionally, the new substations will increase the availability and reliability of the VAB Tower C power system. This project consists of replacing existing VAB Tower C substations 804, 874 (10th floor) and 875 (32nd floor) and all associated 480V sub-fed panels located inside Tower C at the VAB with new reliable code compliant electrical substations and associated downstream equipment. Additionally, a new Arc Flash study will be performed as a part of this project. This is a 100% Small Business Set-Aside procurement. The project period of performance is 800 calendar days. Estimated award amount is anticipated between $5,000,000 and $10,000,000.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"80KSC025R0009","place_of_performance":{"zip":"32899","state":{"code":"FL"},"country":{"code":"USA"}},"product_service_code":"Y1BG"},{"dates":{"posted":"2025-09-03","response_deadline":{"raw":"2025-09-08T14:00:00-04:00","utc":"2025-09-08T18:00:00Z","date":"2025-09-08","time":"14:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/f2cd90ac28ca4b079ce81575a0dfdec5/view"},"naics":{"codes":["237130"],"primary":"237130"},"title":"Vehicle Assembly Building (VAB) Power Phase I (Tower C), Project Control Number (PCN): 99300","agency":{"office":{"code":"80KSC0","name":"NASA KENNEDY SPACE CENTER"},"subtier":{"code":"8000","name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION"},"department":{"code":"080","name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION"},"office_address":{"zip":"32899","city":"KENNEDY SPACE CENTER","state":"FL","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2025-09-23","archive_type":"auto15"},"contacts":[{"name":"LaCorsha Noel","role":"primary","email":"Lacorsha.d.noel@nasa.gov","phone":"3218673464"},{"name":"Stephen Crooks","role":"secondary","email":"Stephen.e.crooks@nasa.gov","phone":"3218671583"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"f2cd90ac28ca4b079ce81575a0dfdec5","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"62c93d92d8cb06269e3339d2220404b65396dc4c66696a6f7f895ab4df1e4d33","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-09-16T17:45:50.850439Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"text":"NASA/John F. Kennedy Space Center is issuing a Request for Proposal (RFP) for 80KSC025R009, Revitalize Power Systems at the VAB Tower C, John F. Kennedy Space Center, Florida. The North American Industry Classification System (NAICS) code for this procurement is 237130, Power and communication Line and Related Structures Construction with a size standard of $45,000,000. The objective of this project is to replace the obsolete substations and associated equipment which will significantly increase the safety of the facility and maintenance personnel. Additionally, the new substations will increase the availability and reliability of the VAB Tower C power system. This project consists of replacing existing VAB Tower C substations 804, 874 (10th floor) and 875 (32nd floor) and all associated 480V sub-fed panels located inside Tower C at the VAB with new reliable code compliant electrical substations and associated downstream equipment. Additionally, a new Arc Flash study will be performed as a part of this project. This is a 100% Small Business Set-Aside procurement. The project period of performance is 800 calendar days. Estimated award amount is anticipated between $5,000,000 and $10,000,000.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"80KSC025R0009","place_of_performance":{"zip":"32899","state":{"code":"FL"},"country":{"code":"USA"}},"product_service_code":"Y1BG"},{"dates":{"posted":"2025-09-04","response_deadline":{"raw":"2025-09-08T14:00:00-04:00","utc":"2025-09-08T18:00:00Z","date":"2025-09-08","time":"14:00:00","utc_offset_seconds":-14400}},"links":{"sam":"https://sam.gov/workspace/contract/opp/6a93abd024f5457c85e027145c20745b/view"},"naics":{"codes":["237130"],"primary":"237130"},"title":"Vehicle Assembly Building (VAB) Power Phase I (Tower C), Project Control Number (PCN): 99300","agency":{"office":{"code":"80KSC0","name":"NASA KENNEDY SPACE CENTER"},"subtier":{"code":"8000","name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION"},"department":{"code":"080","name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION"},"office_address":{"zip":"32899","city":"KENNEDY SPACE CENTER","state":"FL","country":"USA"},"organization_type":"OFFICE"},"status":{"active":false,"archive_date":"2025-09-23","archive_type":"auto15"},"contacts":[{"name":"LaCorsha Noel","role":"primary","email":"Lacorsha.d.noel@nasa.gov","phone":"3218673464"},{"name":"Stephen Crooks","role":"secondary","email":"Stephen.e.crooks@nasa.gov","phone":"3218671583"}],"base_type":{"code":"o","label":"Solicitation"},"notice_id":"6a93abd024f5457c85e027145c20745b","set_aside":{"code":"SBA","label":"Total Small Business Set-Aside (FAR 19.5)"},"provenance":{"extract":{"url":"https://s3.amazonaws.com/falextracts/Contract%20Opportunities/Archived%20Data/FY2025_archived_opportunities.csv","etag":"\"d47226e3d2c6545974b252e103f82b34-139\"","fetched_at":"2026-09-16T17:45:50.850439Z","row_sha256":"ffcabb6ce98974c017807c8bf636625808e15983aa0c4961de27f592b33d3462","last_modified":"2026-09-13T14:49:20Z"},"updated_at":"2026-09-16T17:45:50.850439Z","first_seen_at":"2026-09-16T17:45:50.850439Z"},"description":{"text":"NASA/John F. Kennedy Space Center is issuing a Request for Proposal (RFP) for 80KSC025R009, Revitalize Power Systems at the VAB Tower C, John F. Kennedy Space Center, Florida. The North American Industry Classification System (NAICS) code for this procurement is 237130, Power and communication Line and Related Structures Construction with a size standard of $45,000,000. The objective of this project is to replace the obsolete substations and associated equipment which will significantly increase the safety of the facility and maintenance personnel. Additionally, the new substations will increase the availability and reliability of the VAB Tower C power system. This project consists of replacing existing VAB Tower C substations 804, 874 (10th floor) and 875 (32nd floor) and all associated 480V sub-fed panels located inside Tower C at the VAB with new reliable code compliant electrical substations and associated downstream equipment. Additionally, a new Arc Flash study will be performed as a part of this project. This is a 100% Small Business Set-Aside procurement. The project period of performance is 800 calendar days. Estimated award amount is anticipated between $5,000,000 and $10,000,000.","origin":"extract"},"notice_type":{"code":"o","label":"Solicitation"},"schema_version":1,"solicitation_number":"80KSC025R0009","place_of_performance":{"zip":"32899","state":{"code":"FL"},"country":{"code":"USA"}},"product_service_code":"Y1BG"}],"due_at":"2025-09-08T18:00:00Z","due_date":"2025-09-08","closes_at":"2025-09-08T18:00:00Z","awardable":false,"dept_key":"d-080","dept_name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION","sub_key":"s-8000","sub_name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION","office_key":"o-80KSC0","office_name":"NASA KENNEDY SPACE CENTER","state":"FL","county":"12009","county_name":"Brevard County","city":null,"city_name":null,"country":"USA","winner_key":"U747Y6MFX2A5","amount":null,"linked_awards":10,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z","principal_notice_id":"6a93abd024f5457c85e027145c20745b","description":{"text":"NASA/John F. Kennedy Space Center is issuing a Request for Proposal (RFP) for 80KSC025R009, Revitalize Power Systems at the VAB Tower C, John F. Kennedy Space Center, Florida. The North American Industry Classification System (NAICS) code for this procurement is 237130, Power and communication Line and Related Structures Construction with a size standard of $45,000,000. The objective of this project is to replace the obsolete substations and associated equipment which will significantly increase the safety of the facility and maintenance personnel. Additionally, the new substations will increase the availability and reliability of the VAB Tower C power system. This project consists of replacing existing VAB Tower C substations 804, 874 (10th floor) and 875 (32nd floor) and all associated 480V sub-fed panels located inside Tower C at the VAB with new reliable code compliant electrical substations and associated downstream equipment. Additionally, a new Arc Flash study will be performed as a part of this project. This is a 100% Small Business Set-Aside procurement. The project period of performance is 800 calendar days. Estimated award amount is anticipated between $5,000,000 and $10,000,000.","html":null,"origin":"extract"},"contacts":[{"name":"LaCorsha Noel","role":"primary","email":"Lacorsha.d.noel@nasa.gov","phone":"3218673464"},{"name":"Stephen Crooks","role":"secondary","email":"Stephen.e.crooks@nasa.gov","phone":"3218671583"}],"place_of_performance":{"zip":"32899","state":{"code":"FL"},"country":{"code":"USA"}},"office_address":{"zip":"32899","city":"KENNEDY SPACE CENTER","state":"FL","country":"USA"},"naics_codes":["237130"],"award":null,"attachments":[],"awards":[{"award_key":"CONT_AWD_80KSC025C0003_8000_-NONE-_-NONE-","permalink":"https://www.usaspending.gov/award/CONT_AWD_80KSC025C0003_8000_-NONE-_-NONE-/","piid":"80KSC025C0003","parent_piid":null,"award_type":"DEFINITIVE CONTRACT","vendor_key":"U747Y6MFX2A5","recipient_name":"A. WEST ENTERPRISE, LLC","recipient_uei":"U747Y6MFX2A5","recipient_cage":"5Q7B1","recipient_city":"ALBANY","recipient_state":"GA","sub_name":"National Aeronautics and Space Administration","office_name":"NASA KENNEDY SPACE CENTER","office_key":"o-80KSC0","first_action_date":"2025-09-19","last_action_date":"2026-06-25","actions":4,"obligated":"7041937.00","current_total_value":"7041937.00","potential_total_value":"7041937.00","naics":"237130","psc":"Y1BG","extent_competed":"FULL AND OPEN COMPETITION AFTER EXCLUSION OF SOURCES","set_aside":"SMALL BUSINESS SET ASIDE - TOTAL","offers_received":6,"description":"REVITALIZE POWER SYSTEMS AT THE VEHICLE ASSEMBLY BUILDING (VAB) TOWER C","method":"solicitation","confidence":"high","evidence":["solicitation number 80KSC025R0009 equals the FPDS solicitation identifier","same awarding office 80KSC0"],"opportunity_key":null,"opportunity_title":null}],"related":[{"key":"RFP10990021REVU","latest_notice_id":"d7eb5d70e9fe4bdc8a2c840a5bebff3f","title":"NASA Launch Services II (NLS-II) 2026 On-Ramp","solicitation_number":"RFP10-99-0021-Rev_U","notice_type":"r","first_type":"r","first_posted":"2026-09-04","last_posted":"2026-09-04","notices":1,"due_at":"2026-10-05T20:00:00Z","due_date":"2026-10-05","closes_at":"2026-10-05T20:00:00Z","awardable":true,"open":true,"dept_key":"d-080","dept_name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION","sub_key":"s-8000","sub_name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION","office_key":"o-80KSC0","office_name":"NASA KENNEDY SPACE CENTER","naics":"336414","psc":"V126","set_aside":null,"state":null,"county":null,"county_name":null,"city":null,"city_name":null,"country":null,"winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"},{"key":"AFPKSCEXPARKPARCELS3AND42026","latest_notice_id":"e17b7deb0d014416b0790199f6d507c6","title":"AFP - Lease of Vacant, Undeveloped Land in Exploration Park at Kennedy Space Center","solicitation_number":"AFP-KSC-ExParkParcels3and4-2026","notice_type":"o","first_type":"o","first_posted":"2026-09-04","last_posted":"2026-09-04","notices":1,"due_at":"2026-11-06T22:00:00Z","due_date":"2026-11-06","closes_at":"2026-11-06T22:00:00Z","awardable":true,"open":true,"dept_key":"d-080","dept_name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION","sub_key":"s-8000","sub_name":"NATIONAL AERONAUTICS AND SPACE ADMINISTRATION","office_key":"o-80KSC0","office_name":"NASA KENNEDY SPACE CENTER","naics":"53","psc":"X1PC","set_aside":null,"state":"FL","county":"12009","county_name":"Brevard County","city":"1244275","city_name":"Merritt Island","country":"USA","winner":null,"winner_key":null,"amount":null,"linked_awards":0,"cancelled":false,"archived":false,"updated_at":"2026-09-16T21:18:12.857524Z"}]}